PIMS IN INSTITUTE FOR NUCLEAR STUDIES Brazing Andrzej Soltan Institute for Nuclear Studies.

Slides:



Advertisements
Similar presentations
Pressure 1 atmosphere ~ 1 bar ~ 760 mm Hg ~ 760 torr ~ 100,000 Pa Ion gauges read in mbar i.e. 1x mbar = 1x atm. Sometimes ion gauges read.
Advertisements

26/2704 Vacuum Feature What is vacuum Vacuum in industry
CONTENTS Our Customer Partners Us Our Products Quality Policy & Standards.
KOREA KIYON COMPANY PROFILE. COMPANY PROFILE Korea Kiyon Company, established in 1985, with the highest quality and most technology advanced inert atmosphere.
31/03/11FV 1 CEDAR from flammable gas safety point of view.
Overview of Vacuum Systems Tejas Deshpande 24 July, 2014.
Vacuum & Cooling Systems Updates F. Makahleh On behave of Vacuum & Cooling Group TAC 2013, F. Makahleh, Vacuum & Cooling 1.
Heinz Grote1 Presentation to NSCX WENDELSTEIN 7-X Assembly Max-Planck- Institut für Plasmaphysik KKS-Nr.: 1-AD Dok-Kennz.: -Txxxx.0 Heinz Grote October.
Vacuum Technology Part II of the “What exactly do we have down there?” series.
Stewart Shen October 27, LCLS-XTOD Gas Attenuator LCLS FAC Meeting October 27, 2005 Stewart Shen, Keith Kishiyama and Marty Roeben.
Vacuum systems Electron beam – mean free path: Gun – column - sample Signal detection – electron and X- ray collection: Scattering of emitted electrons.
Matthew Hills Hydrogen System – Piping and Instrumentation Diagram.
PWF 3/01 Plasma Fueling Program1 Pumping Systems for ITER, FIRE and ARIES P. W. Fisher Oak Ridge National Laboratory C. A. Foster Cryogenic Applications.
Vacuum, Surfaces & Coatings Group Technology Department Vacuum tests for CLIC module prototypes 6 November 2013 C. Garion2 Outline: Reminder: specification.
ISOLDE Vacuum Controls (CERN-GSI WS), S. Blanchard TE-VSC-ICM UNICOS Vacuum Objects Specifications Review Sebastien Blanchard TE/VSC Interlocks,
The MICE vacuum system Presented by Mark Tucker at CM-39, 26 June 2014.
Pressure 1 atmosphere ~ 1 bar ~ 760 mm Hg ~ 760 torr ~ 100,000 Pa Ion gauges read in mbar i.e. 1x mbar = 1x atm. Sometimes ion gauges read.
The ESS vacuum team has overall responsibility for all technical vacuum systems used on the: Accelerator, Target and Neutron Scattering Instruments and.
Solar Cell conductive grid and back contact
Status of vacuum & interconnections of the CLIC main linac modules C. Garion TE/VSC TBMWG, 9 th November 2009.
Erhard Huttel ISS/ANKA 1 CLIC damping wiggler CERN Vacuum Requirements etc. for ANKA General Requirements for UHV Vacuum: Pressure without.
Vacuum tests of the accelerating structure mock-up The main outputs of the tests would be the following: Feasibility of the assembly of the vacuum manifold.
Mass spectrometry and the PITZ Sven Lederer Technisches Seminar
PHENIX UPGRADE Stony Brook Project Hadron Blind Detector Glove Box 31Aug05.
Techniques of Vacuum and Basics of High Voltage (2/3) Pauli Heikkinen Jyväskylä University.
PETS EuCARD. Present status and precision assembly L. Sánchez, F. Aragón, J. Calero, J.L. Gutiérrez, E. Rodríguez, F. Toral, CIEMAT 26/10/2011.
DILBERT. Did research and learned about several communication devices – cellular phones, Bluetooth/Wi-Fi, and RFID Did research and learned.
05 Novembre 2003Chamonix XIV Workshop, January How to deal with leaks in the QRL and magnet insulation vacuum Paul Cruikshank for AT/VAC Germana.
Pump design Raimonds Nikoluskins CERN – LIEBE project coordination meeting.
Vacuum issues concerning the Proton Source and LEBT Salvo Marletta, Luigi Celona, Lorenzo Neri, Franco Chines, David Mascali.
Fabrication and measurement of RF components for CLIC study
OLAV III Experience with the LHC Insulation Vacuum System S. Blanchard, P. Cruikshank, B. Jenninger, N. Kos, W. Maan, L. Mourier, N. Provot, J. Wallner.
L. Serio COPING WITH TRANSIENTS L. SERIO CERN, Geneva (Switzerland)
Solar Cells need a top side conductor to collect the current generated They also need a conductive film on the backside.
ESS-Bilbao: MEBT vacuum standarization
CM28 - Vacuum System Update Matt Hills Mike Courthold 1.
National Ignition Facility Vacuum Systems Presentation to OLAV Workshop, ORNL July 11-14, 2011 NIF Vacuum Subsystems Managers Igor Maslennikov* John Hitchcock.
PACS IBDR MPE 27/28 Feb 2002 AIV 1 PACS IBDR Test Cryostat and OGSE Gerd Jakob MPE.
NA62 RICH Gas System V2.0 S. Haider PH/DT/DI LHC-Gas-Project.
Plan for test station Marta Bajko For the Technical Review of FReSCa2 June 2015 Saclay Paris.
TD26CC PLANS FROM CIEMAT Laura Sánchez on behalf Electrical Engineering Group of CIEMAT.
MAGNET#1MAGNET#2MAGNET#3 SATELLITE VB#1 SATELLITE VB#2 SATELLITE VB#3 PRECOOLER#1PRECOOLER#2 DISTRIBUTION VALVE BOX DVB CP#1CP#3CP#2 BUFFER DEWAR LHe 5m.
Vacuum Technology and Components for Cryogenics
CMS Double Chooz HESS Edelweiss Herschel ALICE Detecting radiations from the Universe. EXPERIENCE WITH VACUUM SYSTEM FROM DESY AND CEA SOLUTIONS TTC topical.
Hao Guo LINAC Department Institute of Modern Physics.
Outgassing of Outer Tracker Glue Maarten Buffing (VU) June
DESIGN AND PERFORMANCE OF VACUUM SYSTEM FOR HIGH HEAT FLUX TEST FACILITY Rajamannar Swamy*, Prakash Mokaria, Samir Khirwadkar, Sunil Belsare, M S Khan,
Thin Film Technology - Student Talk Sophie Chauvin 02/02/16 Leak Detection method for Vacuum Systems 1.
Overview of elliptical cryomodules vacuum system Vacuum Equipment Standardization meeting February 2014 P. Bosland – C. Darve – N. Elias.
The PSI protium gas filling system (status report by Claude Petitjean to the Gatchina collaboration meeting June 14-17) Main components of the PSI gas.
Jari Koskinen 1 Thin Film Technology Lecture 2 Vacuum Surface Engineering Jari Koskinen 2014.
Solar Cells need a top side conductor to collect the current generated They also need a conductive film on the backside.
Final Design Cryogenic and mechanical configurations
DILBERT.
Sub-system integration for the VBOX
1.3-GHz Cavity Vacuum Furnace at IB4
HFM Test Station Main Cryostat
Leak Detection Tutorial Work
Cryostat design Mechanical design: Thermal screens: Specifications:
1 Connect pumping equipment (group) with leak detector to insulation vacuum 1 or 2 pumping groups? connected to SB or CM or both? Which pumping group?
Martin Dommach TDR ART Review, Hamburg, September 14, 2012
N infusion study at DESY
Cryostat design Mechanical design: Thermal screens: Specifications:
MINI 1A iAquaMax™ Kidney / water removal system
1A iAquaMax™ Kidney / water removal system
BASIC VACUUM PRACTICE.
Cryogenic behavior of the magnet
Vacuum System Design for the Target Monolith System
News from the GSI test facility SALERNO
Presentation transcript:

PIMS IN INSTITUTE FOR NUCLEAR STUDIES Brazing Andrzej Soltan Institute for Nuclear Studies

Furnace Diameter: 650mm Length: 2000mm Max. temperature: 1150°C Temperature flatness: ±5°C Vacuum level: better then 1x10 -6 mbar in 850°C Max weight of brazing elements: 250 kg Leak rate: 3x10 -3 mbar*l/s Ventilation: pressured nitrogen Temperature growth speed: 0÷850°C – 1h 850÷1150°C – 1h

Furnace… Control system: based on Siemens PLC controller steering with touch screen cell phone alarm system Pumping system: Based on dry pumps Low Vacuum : Root’s pump with rotary pump High Vacuum: CoolVac – cryogenic pump Pumping system manufacturer: Leybold Pumping speed Mechanical pumps: 1250m 3 /h Cryogenic pump: l/s

Leak rate detection  By Helium detector  By mass spectrometry Equipment: Varian PD03 Helium detector mobile and stationary version Parameters: Leak rate: 5x Pa*m 3 /sec Maximum test port pressure: 13 mbar Pumping speed: Combo pump (scroll and diaphragm): 3m 3 /h Turbomolecular pump: 1.8 l/s (helium) Equipment: Pfeiffer PrismaPlus Type: quadrupole Mass range: AMU Special function: leak detector for all masses of Helium Maximum test port pressure: 1x10 -4 mbar

Pumping system  Stationary  Mobile Manufacturer: Varian Type: Mobile pumping station Pumping system: dry pumps Turbomolecular pump: Turbo V-301 Scroll pump: SH110 Vacuum gauge full range: FRG-700 Manufacturer: Varian Type: TPS-compact Pumping system: dry pumps Turbomolecular pump: Turbo V-81 Scroll pump: IDP-3 Vacuum gauge full range: FRG-700

Questions  Water pressure test: for a clean level would it be better to use a pressured gas (helium)?  Cleaning before brazing: cleaning, maybe electropolishing (especially before nickel-plating)?