1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:

Slides:



Advertisements
Similar presentations
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
Advertisements

1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:
Heating and Air Conditioning I
Innovative Air Distribution for Healthcare Facilities.
Model predictive control for energy efficient cooling and dehumidification Tea Zakula Leslie Norford Peter Armstrong.
Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering PSU, Univ. Park, PA Web: Chilled Surfaces:
1 Condensation Control Experiences in an “historic” Building with Movable Sash ASHRAE Anaheim Seminar 53, 1/28/04 Stanley A. Mumma, Ph.D., P.E. Professor,
Objectives Finish with ducts and fans Define project topics.
Ceiling Radiant Cooling Panels as a Viable Distributed Parallel Sensible Cooling Technology Christopher L. Conroy, E.I.T. L. D. Astorino Companies, Pittsburgh.
Ventilation Effectiveness & Indoor Air Quality Douglas Spratt February 2001.
1 Meeting ASHRAE Fundamentals, Standard 55 & 62.1 with Chilled Beams Displacement Ventilation.
1 Decoupling the Building Latent and Sensible Loads Using 100% Outside Air Systems ASHRAE Chicago Seminar 39 January 24, 2006 Stanley A. Mumma, Ph.D.,
Industrial Ventilation - A major control measure Dr. AA, UTM.
Energy Recovery System Hadi Fattah Chris Korkuch Scott Lacey Ryan Neary Colin O’Neill.
Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015.
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
WESTINGHOUSE ELECTRIC NUCLEAR ENGINEERING HEADQUARTERS DANIEL AUGHENBAUGH - MECHANICAL OPTION Westinghouse Nuclear Engineering Headquarters Daniel Aughenbaugh.
AIR CONDITIONING SYSTEMS 1. All Air Systems An all-Air System is defined as a system providing complete sensible and latent cooling capacity in the cold.
Field Experience Controlling a Dedicated Outdoor Air System (DOAS)
NAFA Guide to Air Filtration. Chapter 13 Owning and Operating Cost By Dirk ter Horst April 19 th, 2012 Another Approach…. Air Filter Comparison.
Web Based BACnet Compatible Controls Applied to Emerging HVAC Technologies Stanley A. Mumma, Ph.D., P.E. Prof. Architectural Engineering Penn State University.
PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Kurt M. Shank, M.S. & Stanley A. Mumma, Ph.D., P.E. College of Engineering Department.
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
Objectives Discuss Project Topics Learn to design VAV and DOAS System.
© American Standard Inc Fan Pressure Optimization The Trane Company.
1 Stanley A. Mumma, Ph.D., P.E. Professor Emeritus Penn State Univ. Park, PA Web: Active and Passive.
Implementing Demand Controlled Ventilation to Meet ASHRAE Standard By Klas C. Haglid, P.E., R.A., CEM 1.
Conditioning of Moist Air
1 So far… We’ve developed a general energy balance We’ve developed a general material balance We’ve only actually looked at systems that are under steady.
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
Direct Digital DBT, %RH, and Condensate Control for a DOAS-CRCP system ASHRAE Winter Meeting Symp. 3, Orlando-Feb. 6, 2005 Stanley A. Mumma, Ph.D., P.E.
NRUCFC Headquarters Building Sterling, VA Architectural Engineering Senior Thesis Margaret McNamara | Mechanical Option Advisor | Dr. Stephen Treado.
Application and Design for The Charles E. and Mary Parente Life Sciences Building Kings College Wilkes-Barre PA Ryan James Wanko Building Mechanical and.
2003 ASHRAE Annual Meeting Kansas City Energy Conservation Benefits of a DOAS with Parallel Sensible Cooling by Ceiling Radiant Panels Jae-Weon Jeong Stanley.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA 2014 Conference Presentation.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:
Achieving Dry Outside Air in an Energy-Efficient Manner PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Stanley A. Mumma, Ph.D.,
Final Projects Grading criteria is posted on the course website Preliminary results are due Next Tuesday Final Project delivery on Monday Dec. 7 th –Final.
Announcement Course Exam November 3rd In class: 90 minutes long Examples will be posted on the course website.
Jesse A. Fisher Mechanical Option Spring 2005 Riverpark Corporate Center, Phase 1 Salt Lake City, Utah.
Hamot Women’s Hospital Erie, PA Michael Galleher Mechanical Option l AE-Senior Thesis l April 12, 2011 l Advisor Dr. Jelena Srebric.
Objectives Discuss Project Topics Learn to design VAV and DOAS System.
ASHRAE Tech. Paper, Long Beach, CA. June 26,2007 Poster Session Presentation: Poster contents. Jae-Weon Jeong, PhD Assistant Professor. Texas A&M University-Kingsville.
Application of Ceiling Radiant Cooling in a University Environment ASHRAE Chicago Seminar 7, 1/26/03 Stanley A. Mumma, Ph.D., P.E. Professor, Architectural.
Objectives Propose residential system related final project –Compare VAV systems with DOAS systems.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
Objectives Finish heat exchangers Air Distribution Systems
HCB 3-Chap 19B: All-Air_Multizone_Reddy1 Chapter 19B: ALL-AIR SYSTEMS FOR MULTIPLE SPACES Agami Reddy (July 2016) 1)CAV terminal reheat 2)CAV multizone.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
Technology in Architecture
Lesson 24 Appendix F Outside Air Calculation
Pros and Cons of operating a DOAS EW continuously
By: John D. Villani, P.E., LEED AP, QCxP, CEM, GBE
Sustainability and Life Cycle Costing of Air Filtration
Placement Considerations
Munters DOAS, Chilled Beams and VRV
Feasibility of Ice Storage
HCB 3-Chap 19A: All-Air Systems_Single Zone
Variable Refrigerant Volume
Chapter 19B: ALL-AIR SYSTEMS FOR MULTIPLE SPACES
Professor of Architectural Engineering College of Engineering
Follow-ups from Classes 8 and 9
Objectives Finish with Heat exchangers
Minimizing Heating & Cooling Costs
Objectives Review exam problems Further discuss final projects
Objective Revie the Cooling Cycle Learn about air distribution systems
Lesson 24 Appendix F Outside Air Calculation
Objectives Discuss Rotary Heat Exchangers
Presentation transcript:

1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web: Contaminant Transport and Filtration Issues with DOAS ASHRAE Louisville Meeting June 23, 2009

2 Objective  Dispel the common perception that DOAS is inferior to all air system when contaminant flushing rates from occupied spaces are considered.  Shift the DOAS filter selection paradigm.

3 DOAS Defined OA DOAS Unit w/ TER, CC, & Filtration Cool/Dry Supply Parallel Sensible Cooling System High Induction Diffuser Building with Sensible and Latent Cooling Decoupled RA

4 Facility floor area and zoning for case study 10,000 ft 2 Interior Zone 3 1,000 ft 2 Exterior Zone 1 9,000 ft 2 Exterior Zone 2 10 ft high ceilings--all zones

5  VAV system: –Supply air (SA) flow rate, 16,000 cfm, of which 4,000 cfm is OA. – Perimeter zones 1 and 2, each receives 1 cfm/ft 2 of supply air via a shut off box VAV system. Since the SA is 25% OA, then each perimeter zone is receiving 0.25 cfm/ft 2. – Interior zone 3 receives 0.6 cfm/ft 2 of supply air via a VAV system, i.e cfm/ft 2 OA  DOAS: –OA flow for the facility, 4,000 cfm uniformly distributed in each zone, or 0.20 cfm/ft 2. Case Study Conditions

6 Transient analysis is based upon the following simplifying assumptions:  Well mixed zones.  No interzonal transfer.  Contaminants stay suspended.  VAV system is analyzed while operating in the minimum OA mode (4,000 cfm OA), and a supply airflow rate of 16,000 cfm. Releases during full economizer mode (resulting in very high peak space concentrations when releases occur near the OA inlet) will not be presented.  The capacitance of the duct system, and its associated influence on the transient response, is neglected.

Filter,  f VAV System Schematic

Filter,  f DOAS Schematic

9 Transient dimensionless concent’n from release near OA inlet w/  f = 0% VAV Zone 3 DOAS VAV Zone 1 & 2

10 Transient concent’n from release near OA inlet w/ VAV  f = 80% & DOAS  f = 98% NOTE: Exposure w/ DOAS is 1/425 that of VAV. VAV Zone 3 DOAS VAV Zone 1 & 2

11 DOAS filter  necessary to match the space concent’n/exposure after 60 min. for a given VAV filter . Ref: OA intake occurances. Paradigm shift!! =  = exp = conc.

12 Filter Optimization Assumptions  Same SA flows as in transient analysis: VAV 16,000 cfm; and DOAS 4,000 cfm.  Assume that the filter loading profile is exponential, causing the average pressure drop over the life of the filter to be: [(Dploaded opt - Dpclean opt)/2]*Fill-ratio Fill-ratio used.  Reference replacement frequency is 3 months for VAV and 6 months for DOAS  fan/motor combined efficiency, 60%.  Electrical cost, $0.10/kWh.  Term of analysis, 5 years.  Fan operating hours per year, 4160 hours.  Neglect the time value of money and inflation.

13 Merv 11 Filter 75%  Merv 13 & 14 Filter 94 & 98%  Merv 16 Filter 99.7%  Filters used in the Optimization

14 Optimal Sol. For VAV & DOAS Filters w/ Equal 1hr Conc’n System Filter eff. Optimal Face area, ft 2 Months between filter change Filter 5 yr. 1 st cost, $ Fan 5 yr. Op cost based on filter avg DP, $ Total 5 year Cost, $ VAV $753$3,246$3,999 DOAS $519$870$1,389 VAV $3,959$3,611$7,570 DOAS $717$1,350$2,067 VAV $5,368$5,650$11,018 DOAS $1,052$1,392$2,444

15 DOAS filter Optimization based on Monthly Replacement System Filter eff. Optimal Face area, ft 2 Months between filter change Filter 5 yr. 1 st cost, $ Fan 5 yr. Op cost based on filter avg DP, $ Total 5 year Cost, $ VAV $753$3,246$3,999 DOAS944.5/9.31/6.5$1,635/ $519 $1,401/ $870 $3,036/ 1,389 VAV $3,959$3,611$7,570 DOAS983.5/8.81/6.4$1,823$2,130$3,953 VAV $5,368$5,650$11,018 DOAS /8.91/6.5$2,981$2,137$5,118 $

16 Conclusions 1.A common attitude that contaminant flushing is a problem with DOASs is not warranted when the proper DOAS filter is selected, i.e. one better than the filter used in a comparably performing VAV system. 2.The old “equivalence” paradigm needs to change. 3.Guidance is offered, at least for one set of conditions, on DOAS filter efficiencies. And a method is provided for use on other sets of conditions. 4.Finally, contrary to conventional wisdom, the selection of better and more expensive DOAS filters resulted in optimized performance costing less— far less —than VAV systems.

17

18 VAV Governing Equations

19 DOAS Governing Equations