Appendix H: Chapter 40: Fluoroscopy

Slides:



Advertisements
Similar presentations
DIGITAL RADIOGRAPHY.
Advertisements

Digital Radiography.
Fluoroscopy Equipment Operation
X-RAYS IN MOTION “Viewing dynamic studies of the human body”
Digital Radiographic Imaging 101
X-ray radiography Seminar The "geometrical" unsharpness of X-ray images is limited by finite dimension of the source, i.e. the window on.
Digital FLUORO Summer 2008.
Day 19: Electrostatic Potential Energy & CRT Applications
Digital Technology 14.2 Data capture; Digital imaging using charge-coupled devices (CCDs)
Digital Radiography Chapter 22. History of Digital Radiography Slower process of conversion because no pressing need to convert to digital radiography.
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
X-Ray Production & Emission
Fluoroscopy: Viewing Systems
QUALITY ASSURANCE ADVANCED IMAGING EQUIPMENT CHAPTER 10.
Fluoroscopy Equipment
FLUOROSCOPY.
Quality Control Rad T 110.
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
DIGITAL FLUOROSCOPY.
Special Imaging Systems
F luoroscopy. 2 Fluoroscopy system 3 Different fluoroscopy systems  Remote control systems Not requiring the presence of medical specialists inside.
Fluoroscopy Intro to EQUIPMENT
ECE 5th SEMESTER Subject Consumer Electronics (CE)
FLUOROSCOPY EQUIPMENT
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
Image Quality Radiographic Resolution.
Fluoroscopy Equipment. Introduction Fluoro: is dynamic radiographic examination Fluoroscopy is primarily domain of the radiologist The role of radiographer.
Control room High resolution flat screen monitors CCD image intensifiers are easily identified by their shape A modern fluoroscopic suite.
Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.
Fluoroscopy Q&A Robert L. Metzger, Ph.D..
Angiographic facilities Tortorici Chapter 11. Designed around exam table 500 sq feet min. (25 x 20) 60 sq feet in control room Wide doors, (multiple)
Pulse-Height Analyzers Basic Functions Single Channel Analyzers Time Methods Multi-channel Analyzers.
What is being tested? (kVp, mA, mAs, mR?) What is the purpose of the HVL test? If an x-ray tube does not pass the HVL test what is done to correct the.
Chapter 3: Factors of Image Quality 1. Interlaced vs. progressive scanning 2. Matrix size 5. Field of view (FOV) 3. Vertical resolution 4. Horizontal resolution.
TELEVISION CAMERA TUBES
RAD 254 Chapter 27 Digital Fluoroscopy
 Display Devices Display Devices  Display Hardware  Components of CRT Components of CRT  Refresh CRT Refresh CRT  Electron Gun  Focussing system.
Fluoro Equipment Review RHB Fluoro Syllabus & Rad Prot
RAD 150 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic (motion)
RAD 354 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Doses in Fluoroscopy factors influencing patient doses Colin Martin and David Sutton.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
FLUOROSCOPY & IMAGE INTENSIFICATION Sergeo Guilbaud, RT School of Radiologic Sciences.
History of digital radiology 1980 Kinos L.T. ET all developed a portable radiographic X-ray camera made of tantalum and aluminum. Digital radiography.
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
Resident Physics Lectures
IMAGE ORTHICON.
Imaging System Components
Fluoroscopic Unit Thomas Edison 1896.
Equipment Operation and Maintenance
Fluoroscopy: Dynamic Imaging Systems
Resident Physics Lectures
Fluoroscopic Brightness Control Systems
Fluoroscopic Image Intensifier Image production
Fluoroscopy Dynamic Image Recording Systems
Fluoroscopy: Viewing Systems
Fluoroscopy Static Image Recording Systems
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy – Viewing Systems Optical Mirrors TV Camera & TV Camera Tubes Charge Coupled Devices (CCD) Based on: Principles of Radiographic Imaging, 3rd.
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy Static Image Recording Systems
Flouroscopic imaging.
Fluoroscopic Image Quality Considerations
Fluoroscopic Image Intensifier Image Production
Fluoroscopy: Static Image Recording Systems
Fluoroscopic Image Quality Considerations
Chapter 2 Overview of Graphics Systems
Brightness Control Systems
Presentation transcript:

Appendix H: Chapter 40: Fluoroscopy

Spot film camera (Photospot) (105 mm in this case) Cine (35 mm) camera Video camera Spot film device Image intensifier

A C-arm fluoroscope X-ray tube Patient table Image intensifier Video camera or CCD Image intensifier Cine camera Cine film. Rolls of 35mm film, hundreds of feet long, typically contained multiple projections of the coronary arteries and often the left ventricle. Though most institutions have gone digital, many will still have cans of film and a cine projector stashed in an archive. X-ray tube Patient table

The transfer of energy through the fluoroscopic imaging chain The three major pieces of equipment in the fluoroscopic imaging chain are the: 1. image intensifier, 2. the video camera, and 3. the CRT monitor

How a Fluoroscopic Image Gets Intensified and Digitized 6. Video camera (old) or CCD (microchip, like in home camcorders) translates image into electrical (video) signal 7. Computer assigns pulses from video signal values in binary code (0s and 1s) and stores them as image data 8. Displayed on monitor Video signal Video signal 5. Optical lens focuses light Image Intensification tube 4. Electrons are accelerated toward a tiny fluorescent screen at other end of image intensifier. Concentration of electrons and added kinetic energy make image tens of thousands of times brighter. 3. Light stimulates a photoemissive material to liberate electrons. Image pattern is maintained 2. X-rays excite atoms of a fluorescent screen, light is given off. This is fluoroscopy in its simplest form but the image is very dim. 1. X-rays pass through the body or are attenuated, thus forming a pattern (aerial image) of the anatomy they pass through. Photons from the X-ray tube

Image Intensifier (II) Output Phosphor Zinc Cadmium Sulfide Anode 25,000 V Electrostatic focusing lens Glass envelope Photocathode Cesium & Antimony Concave surface so all electrons arrive at the output screen at the same time, but causes vignetting. Input Phosphor CsI

The transfer of energy through the fluoroscopic imaging chain 3000 light photons at the output phosphor Focal Point 50 Photoelectrons at the photocathode 1000 light photons at the input phosphor For every one incident X-ray photon

(zinc-cadmium sulfide) Anode 25kV + potential Flux Gain Output Phosphor (zinc-cadmium sulfide) Electrostatic focusing lens Photocathode Electrons accelerated across the tube gain kinetic energy from the attractive force of the anode (conversion efficiency). The collision at the output screen liberates that energy in the form of more light photons

(zinc-cadmium sulfide) Minification Gain 1” diameter Output Phosphor (zinc-cadmium sulfide) The ratio of the areas of the input and output screens is expressed as the minification gain. 92 12 = 81 times Input Phosphor (CsI) 9” diameter

Total Brightness Gain The product of the flux gain and the minification gain is the total brightness gain. If the flux gain were 70, and the brightness gain 81 70 x 81 = 5670 total brightness gain 5000-30,000 is the range

Quantum Mottle Conversion factor Because the image intensifier makes the image on the output screen thousands of times brighter than the image on the input screen, much less radiation is needed. If too few photons are used, the image becomes grainy and unacceptable for diagnostic purposes. Generally speaking a better image is always obtained by using more photons, but the price is paid in patient dose. Conversion factor The intensity of illumination at the output phosphor (candela per meter squared) to the radiation intensity that produced it (mR/s) Typical conversion factors of 50 to 300 relate to the 5000-30,000 BG

Veiling Glare Scatter radiation from x-ray, electrons, and light

(As opposed to increased OID magnification) Multifield (Duel focus) Electronic Magnification (As opposed to increased OID magnification) By increasing the positive charge on the electrostatic focusing lens, the convergence (focal) point is changed (further from out put screen). } 7” } 9” } 7” mode 11” mode 11”

} } } Duel focus or Electronic Magnification When the convergence point is further from the output screen, (blue) the photoelectrons have further to diverge, and the image arriving at the output screen is larger. Electronic magnification creates better resolution But patient dose is increased. } 7” } 9” } 7” mode 11” mode 11”

Automatic Brightness Control (ABC) While doing fluoroscopy the .5 to 5 mA, and the kVp will be automatically adjusted to compensate for changes in part thickness, composition of the part as the fluoro tube is being moved. ABC adjusts the mA. Lag is evident, especially if the tube is moving fast. ABC also increases patient dose when using electronic magnification

Resolution Measured in line pairs. Measuring the resolving power of imaging equipment using a line pair test tool Measured in line pairs. One line and one space is a line pair 1 mm = 1 line pair per millimeter of spatial resolution

A Line Pair Test Tool (for Testing Spatial Resolution) The Test Tool provides line pairs of various sizes to measure spatial resolution 1 mm 1 mm 1 mm 1 mm 1 mm

Vidicon and Plumbicon camera tubes

Vidicon Camera Window Signal Plate Tube Target Anode Electron gun (cathode) Globules Video Signal (from signal plate) Control grid Steering and deflecting coils

The transfer of energy through the fluoroscopic imaging chain Optical lens to focus light from II

Coupling of the II to the camera * Fiber optics * Lens coupling * Beam splitting mirror allows photospot and camera filming

The transfer of energy through the fluoroscopic imaging chain Optical lens to focus light from II No signal High intensity Low intensity Modulation

Interlaced Scanning 262 1/2 Odd Lines scanned first = Field 1 262 1/2 Even Lines scanned first = Field 2 2 Fields = 1 Frame

Radiography (Film or digtal) On Fluoro Why are densities reversed on the fluoro monitor * Low atomic densities = * Low attenuation = * Input phosphor glows brightly * Camera target highly excited. * Video signal is strong * Light area on monitor * Low atomic densities = * Low attenuation = * Many photons interact with IR = * Dark area on image Comparison of the low density (air filled) maxillary sinus as seen on film or digital monitor, and in standard fluoroscopic mode. Radiography (Film or digtal) On Fluoro

The transfer of energy through the fluoroscopic imaging chain Optical lens to focus light from II No signal High intensity Low intensity

Question: How is a conventional fluoroscopic, analog imaging chain converted to digital? ADC 1 ALU CU Primary Memory Secondary (RAM) DAC

Spot films recorded on a spot film device * Both are taken during fluoroscopy 4 on 1 * Both are radiographic exposures * Both are 9 x 9 inch films made especially for this purpose, (though some fluoroscopes use standard size cassettes) 1 on * Both were filmed using the same device, but in different formats.

Spot film camera (Photospot) (105 mm in this case) Cine (35 mm) camera Video camera Spot film device Image intensifier 35 mm cine film. Real time motion, projected on a projector.

Spot films (Photospots) recorded on a spot film (photospot) camera 105 mm identifiable by sprockets that drives the roll of film that is unique for this size * Both were taken during fluoroscopy * Both are fluoroscopic exposures (i.e. taken off the output phosphor of the II.) * Both are serial films (not designed to be projected as a moving image, but taken in rapid sequence such as 1, 2, or 4 a second 105 mm * Both are filmed by the same camera but are different sizes. 90 mm (cut film)

Flat Screen Monitors