BCWC Water-cooled water chillers with centrifugal compressor/s

Slides:



Advertisements
Similar presentations
Daikin Altherma™ Troubling Shooting
Advertisements

1 Optimal Control of Chiller Condenser Sub-cooling, Compressor Speed, Tower Fan and Pump Speeds, and IGV Omer Qureshi, Hassan Javed & Peter Armstrong,
CO2 CascadeComp_Studi Galileo  1 Semi-Hermetic Compressors for CO 2 Cascade Systems Hermann Renz Bitzer Kuehlmaschinenbau GmbH  Germany.
ENERGY SAVING Product Offering COMPRESSOR MARKETING OPPORTUNITIES.
HVAC System Design PES Institute of Technology. Objective Goal: To develop an automotive air-conditioning system that is smaller and lighter than with.
Partnership Gwinnett + Southeast Green Series- Debunking Energy Efficiency Myths: Why your bottom line depends on Energy Efficiency Property of VIS VIVA.
Air Conditioning Compressors.
Refrigeration Cycles Chapter 11.
NH 3 BASED SCREW COMPRESSOR CHILLER. We use Alfa-Laval (Sweden) make WPHEs in the evaporator as well as the condenser(optional) in the chilling system.
Next… How SolarCool saves so much energy. Next… Evaporator Compressor SolarCool Condenser Expansion Valve Staged compression system, full load – no sun.
COMMERCIAL REFRIGERATION
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
Next…. Why solar thermal saves so much energy… Next… Evaporator Compressor Condenser Staged Compression System in normal run process Assuming full load.
Aqualean Product Presentation 1 By Laurent Domenget Product Manager, Rooftop & Packaged Air Units.
RLC-CMS002-E4© American Standard Companies, inc All Rights Reserved Concentration of intelligence, High reliability. Series R TM.
Air Compressors.
Motors and Compressed Air MAE 406 Energy Conservation in Industry Stephen Terry.
M. Battistin – 1 st September 2009 EN/CV/DC 1 M. Battistin (EN/CV/DC) 1 st October 2009 ATLAS cooling Group - Thermosiphon solution for ATLAS ID cooling.
Next…. Evaporator Compressor Condenser Staged Compression System in normal run process Assuming full load requirement, all compressors will run. Expansion.
0/11TU Dresden – CERN FCC – Sept 2014 Nelium as Refrigerant for the Beam Screen and Current Lead Cooling of the FCC Fakultaet Maschinenwesen, Institut.
REFRIGERATION, COMPRESSED AIR SYSTEMS & EFFICIENT USE OF ENERGY
The new Super Multi from TCUK
Refrigeration Terms Cooling Load, Cooling Capacity – Q in Compressor Load – W in Condenser Load – Q out Tons of Refrigeration – Rate of Heat Input Refrigerant.
Water piping design.
Perfect solution for large building
Air conditioning – Refreshes your life Mini-Chiller Applied Systems Sales1 EWA(Y)Q-AAV3P Residential Mini-Chiller Heating EWAQ - AA3VP EWYQ - AAV3P Cooling.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
AIR-COOLED SCREW CHILLER FAS Air-Cooled Screw Chiller – FAS-E (Low Noise)
Flooded Screw Chiller FWSF Electronic Expansion Valve Condenser Evaporator Control box compressor Flooded Screw Chiller - FWSF.
1. Footer Date SpiralAIR Product Introduction People. Passion. Performance.
Centrifugal Compressor LEI ZHOU MMAE UCF. Spec. of top cycle compressor Pr=2.42 Working fluid: Neon Mass flow rate: 0.51 kg/s Inlet pressure: 2 atm Inlet.
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
Pressure-Enthalpy and the Variable Refrigerant Cycle
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
Large Tonnage Chiller AC Screw. Content Mechanical System Key Components Control Logic Application 2.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Large Tonnage Chiller WC Centrifugal. Content Mechanical System Key Components Motor Starters Application 2.
Large Tonnage Chiller WC Screw.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Objectives Cooling Cycles –Examples Cooling system components Refrigerants.
Evolution Daikin Chiller Range
HW2 AHU problems: Book: 8.5, 8.25, 8.27, 8.28, 8.22 Cooling Cycles Problems: - Book: 3.1 (page 69), - Book: 3.5 ((page 70), - Out of book: Same like 3.5.
Status of the Marco chiller and Marco capacity analyses Bart Verlaat, Lukas Zwalinski, Maciej Osterga, Jan Godlewski MPI Munich,1 March.
B26 The AsyMatrix Condenser for Heat Pumps Powerful, just smaller.
2016 Chiller New Products Presentation.
Enhancing The Efficiency Of New And Existing Cooling Systems Dr Robert Lamb CEng FInstR Group Sales & Marketing Director Star Refrigeration Ltd.
Air Cooled Chillers with High Speed Centrifugal Compressors.
I-RACH range I-RACH range I-RACH range I-RACH range High efficiency air/water heat pump with INVERTER scroll compressor Range Modularity Components Highlights.
James McIntyre VRF Training Manager V5 Key Components.
Compact line ‘EW*D~J-’ water-cooled chiller range
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Chillers for Tomorrow… Today
Cooling technology Main components and equipments
Desuperheater Heat Transfer Device Manufactured by Maniks
DC Inverter Air-cooled Chiller Aqua Tempo Super II Series
New Air Cooled Scroll Chiller
High Pressure screw compressor
Trane Care Energy RTHD Adaptive Frequency Drive retrofit.
FCI and FCX Range FCI and FCX Range.
FCI and FCX Range FCI and FCX Range.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Title RTWD Water-Cooled Chillers subtitle START
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRK Sales Training Program
BSE Magnetic Levitation Oil Free Centrifugal Chiller Traditional Chiller.
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

BCWC Water-cooled water chillers with centrifugal compressor/s 300 – 1250kW

Water-cooled water chillers with centrifugal compressor/s Technical cooling: efficiency & reliability … and extreme solutions Extreme solutions in terms of: Energy savings Noise levels Limited available power supply Weight Technical Cooling Technological High Perf C.C. Process cooling

Attracting perfection. BCWC units use "oil-free" revolutionary technology. Optimum efficiency at all load conditions Maximum reliability Minimum maintenance Reduced dimensions and weights Ultra silent operation

Water cooled units with centrifugal compressors Water cooled range Water cooled units with centrifugal compressors Water cooled units with screw compressors 300 500 700 900 1100 1300 [kW] BRWC BCWC

Main Features Between 1 and 4 “oil-free” centrifugal compressors Single refrigerant circuit Flooded evaporator Shell & tube condenser Electronic expansion valve R134a refrigerant

BWCW0320A cooling capacity: 320kW compressor/s: 1 circuit:1 300 500 700 900 1100 1300 [kW]

BWCW0630A cooling capacity: 630kW compressor/s: 2 circuit:1 300 500 700 900 1100 1300 [kW]

BWCW0950A cooling capacity: 950kW compressor/s: 3 circuit:1 300 500 700 900 1100 1300 [kW]

BWCW1250A cooling capacity: 1250kW compressor/s: 4 circuit:1 300 500 700 900 1100 1300 [kW]

Magnetic force. BCWC units use "oil-free" revolutionary technology. The impellers operate within a magnetic toroidal field, avoiding mechanical friction. BCWC units are the ideal choice for: Optimum efficiency at all load conditions Maximum reliability Minimum maintenance Reduced dimensions and weights Ultra silent operation

Oli-free centrifugal compressor 2 stages of centrifugal compression Speed Control with inverter Temperature and pressure sensors DC/DC brushless synchronised motor IGV Control of the motor and magnetic bearings

Refrigerant flow

Gas compression

Top level performance. An “Oil-free centrifugal compressor is an inverter-driven compressor which only uses the IGV in extreme conditions. BCWC units are able to adapt the cooling capacity to the load with extreme precision. The T at the set-point is ±0,2°C(*) (*)with load higher that min load Time Delta T BCWC BRWC Traditional

Top level performance. 2 4 6 8 10 12 25% 50% 75% 100% Load [%] EER BCWC - 630kW BRWC - 630kW BCWC units are able to adapt the cooling capacity of the compressor to the load extremely efficiently. The IPLV and ESEER show that the BCWC efficiency is optimized in all operating conditions.

Top level performance. -39% -38% -48% 0,0 10.000,0 20.000,0 30.000,0 40.000,0 50.000,0 60.000,0 70.000,0 80.000,0 90.000,0 100.000,0 320 650 950 1250 Cooling capacity [kW] Running cost [€/year] -100% -90% -80% -70% -60% -50% -40% -30% -20% -10% 0% ''oil-free'' compressor chillers Screw compressor chillers % Energy saving

Top level performance. BCWC units have an integrated soft start. Current [A] Top level performance. BCWC units have an integrated soft start. This means a very low starting current: 320 kW  < 2A 650 kW  < 75A 950 kW  <140A 1250 kW  < 205A Current [A] Time SCR Switch-on Time

“Oil-free”. "Oil-free" means less cost! Reduced energy losses in the heat exchangers Compressors in parallel: optimum performance at partial loads Flooded evaporator: higher energy efficiency No oil changes or filter replacements: low maintenance costs No maintenance of the bearings: low maintenance costs

Flooded Evaporator. "Oil-free" means using flooded evaporator technology without limits. • Increased energy efficiency:  exchange coefficient  ΔT (water/refrigerant) • Reduced energy losses NO superheating  decreased pressure drops • Precise water temperature control “accumulation” effect of refrigerant inside the evaporator

Cooling with style. Lack of “physical” contact means high reliability increased energy savings. Wear and energy losses due to friction are eradicated.

Reduced dimensions. 1000 2000 3000 4000 5000 6000 330 630 950 1250 Models [kW] Weight [Kg] BCWC BRWC The BCWC unit is lighter and more compact than any other compressor with the same capacity featuring traditional technology.

Low noise. Extremely low noise levels Extremely flat spectrum Absence of vibrations 40 50 60 70 80 90 100 330 630 950 1250 Frequency [Hz] Noise power level BCWC BRWC BRWC - LN

Low noise. 40 50 60 70 80 90 100 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz Frequency [Hz] Noise power level BCWC - 630kW BRWC - 630kW BRWC - LN - 630kW Low noise. Screw compressor “oil-free” centrifugal

Competitive comparison BCWC Compressor/s “oil-free” centrifugal compressor Evaporator flooded evaporator with external separator Condenser Shell & tube Expansion Valve EEV as standard TECS-HF “oil-free” centrifugal compressor flooded evaporator with internal separator Shell & tube EEV as standard

Competitive comparison BCWC Compressor/s “oil-free” centrifugal compressor Evaporator flooded evaporator with external separator Condenser Shell & tube Expansion Valve EEV as standard QUANTUM “oil-free” centrifugal compressor flooded evaporator with internal separator Shell & tube EEV as standard

Competitive comparison Efficiency at full load

Competitive comparison Efficiency at partial load: ESEER

Competitive comparison Noise levels

BCWC Water-cooled water chillers with centrifugal compressor/s 300 – 1250kW