New Features on the FONIX FP35 Hearing Aid Analyzer

Slides:



Advertisements
Similar presentations
Viewer’s notes ... to help you …
Advertisements

S o f t w a r e D e f i n e d R a d i o
Improving audibility as a foundation for better speech understanding Pamela Souza, PhD Northwestern University Evanston, IL.
Figures for Chapter 9 Prescription
Audio Compression ADPCM ATRAC (Minidisk) MPEG Audio –3 layers referred to as layers I, II, and III –The third layer is mp3.
Real-ear Measurements with the A-35
6500-CX Calibration. Warning Signs a.k.a. Your 6500-CX might be out of calibration if... n The analyzer doesn’t level. n Distortion measurements seem.
Viewer’s notes... to help you …  At the bottom left of each page there is a page number, when the slide has finished an automated sequence a small star.
ACHIZITIA IN TIMP REAL A SEMNALELOR. Three frames of a sampled time domain signal. The Fast Fourier Transform (FFT) is the heart of the real-time spectrum.
An Update on Hearing Aid Testing
Probe Tube Microphone Measurements (Basics and Definitions) Greg Nassar MCHAS Team University of Manchester.
Verifying Open-Ear Fittings With Speech-Mapping
Hearing and Deafness 2. Ear as a frequency analyzer Chris Darwin.
MCHAS Modernising Children’s Hearing Aid Services Acoustic Feedback Reduction.
Feedback Cancellation in Public Address systems using notch filters Shailesh Kulkarni Vaibhav Mathur Digital Signal Processing-Advanced Topics.
FP35 Hearing Aid Analyzer
Cox data: Average ratings for both sets of instruments for each category (percent preference for each condition)
Electroacoustic Testing of DSP Hearing Aids Christine Cameron & Mary Hostler MCHAS Team University of Manchester.
Spectrum Analyzer. Another Oscilloscope??? Like an oscilloscope Oscilloscope in time domain Spectrum analyzer in frequency domain (selectable)
Digital Signal Processing A Merger of Mathematics and Machines 2002 Summer Youth Program Electrical and Computer Engineering Michigan Technological University.
Fitting Formulas Estimate amplification requirements of individual patients Maximize intelligibility of speech Provide good overall sound quality Keep.
CSD 3000 DEAFNESS IN SOCIETY Topic 8 HEARING AIDS AND ASSISTIVE TECHNOLOGY.
ANSI Overview Hearing Aid Testing and Verification What is ANSI?
EE 198 B Senior Design Project. Spectrum Analyzer.
Advanced Lecture.  dynamic range The ratio of the loudest (undistorted) signal to that of the quietest (discernible) signal in a unit or system as expressed.
1 Live Sound Reinforcement Audio measurements. 2 Live Sound Reinforcement One of the most common terms you will come across when handling any type of.
Introduction to the FONIX 7000 Hearing Aid Test System Software version 1.60.
The effect of frequency compression and high- frequency directionality on horizontal localisation and speech in noise recognition Ingrid Yeend, Anna O’Brien,
Modernising Children’s Hearing Aid Services Sound Field Testing MCHAS TEAM Wave 4 SFR 17/05/04.
Self-Calibrating Audio Signal Equalization Greg Burns Wade Lindsey Kevin McLanahan Jack Samet.
Figures for Chapter 4 Electroacoustic Performance
Amplification systems: Hearing aids May be analog or digital May be analog or digital Consists of a microphone, amplifier, and loudspeaker. Consists of.
Ni.com Data Analysis: Time and Frequency Domain. ni.com Typical Data Acquisition System.
Sampling Terminology f 0 is the fundamental frequency (Hz) of the signal –Speech: f 0 = vocal cord vibration frequency (>=80Hz) –Speech signals contain.
DIGITAL VOICE NETWORKS ECE 421E Tuesday, October 02, 2012.
Hearing aids in noisy environments: Do hearing aids affect risk for NIHL? Fligor and Chasin.
EE Audio Signals and Systems Effects Kevin D. Donohue Electrical and Computer Engineering University of Kentucky.
Features: Easy to use data collector 2 channels simultaneous sampling & display On-site 400-lines FFT spectrum and waveform display; Transfer function.
Intensity, Intensity Level, and Intensity Spectrum Level
Dual-Channel FFT Analysis: A Presentation Prepared for Syn-Aud-Con: Test and Measurement Seminars Louisville, KY Aug , 2002.
Introduction to the 8000 Hearing Aid Test System By: Kristina Frye Frye Electronics, Inc.
Super Power BTE A great new Trimmer Family. The new & complete, fully digital Trimmer family ReSound is proud to introduce the complete new trimmer family,
Audiograms How to read them and what they are.. Terms to know: Audiogram An audiogram is a means of recording the results of a hearing test. It will include.
Environmentally Aware Feature-packed DSP Hearing Aid Amplifier Updated Feb 23, 2010.
Dynamic Range and Dynamic Range Processors
Non contact acquisition of sonic emissions of bearings Assoc. Prof.: Kiril M. Alexiev, Petia D. Koprinkova-Hristova; Dr.: Vladislav V. Ivanov, Volodymyr.
DEVELOPMENT OF NAL-NL2 Harvey Dillon, Gitte Keidser, Teresa Ching,
New Developments in Hearing Technology Dave Gordey, M. Sc. AUD (c)
Figures for Chapter 10 Hearing Aid Selection Dillon (2001) Hearing Aids.
SPECTRUM ANALYZER 9 kHz GHz
Noise Reduction Two Stage Mel-Warped Weiner Filter Approach.
Fitting and Evaluation of FM Systems for HA Users.
EE 495 Modern Navigation Systems Noise & Random Processes Mon, March 02 EE 495 Modern Navigation Systems Slide 1 of 19.
Copyrights Beijing RSTech Co., Ltd. All Rights Reserved Trust System Acoustic Expert Trust System Application Beijing Rui Sen Technology Co., Ltd. Feb/2010.
FP35 Hearing Aid Analyzer
Detection of Signals in Noise and Clutters
Chapter 20 Speech Encoding by Parameters 20.1 Linear Predictive Coding (LPC) 20.2 Linear Predictive Vocoder 20.3 Code Excited Linear Prediction (CELP)
© 2015, Cornell Bioacoustics Research Program Are Raven’s dB measurements SPL? By default, Raven’s dB measurements are relative to an arbitrary reference.
Lifecycle from Sound to Digital to Sound. Characteristics of Sound Amplitude Wavelength (w) Frequency ( ) Timbre Hearing: [20Hz – 20KHz] Speech: [200Hz.
Hz A A A A A A LDL for speech Aided Speech output Functional Gain: The way.
Chapter 10 Digital Signal and Image Processing
ACOUSTIC CAMERA Copyright © PechoM Tüm hakları saklıdır.
Equipment for Measuring Hearing and Calibration
CS 591 S1 – Computational Audio
Self-Adjusted Amplification by Experienced Hearing Aid Users
Introduction to the 7000 Hearing Aid Test System
Duy dang, Robert kern, esteban kleckner
General Engineering Polytechnic University
MAAC 2018 Real-ear Hands on Lab
Voice source characterisation
Presentation transcript:

New Features on the FONIX FP35 Hearing Aid Analyzer Version 6.00

Hardware Features Battery Current Drain External Input (v5) Line In

Software Features Improved Digital Speech Test for Frequency-Shifting Hearing Aids Modified NAL-NL1 Fitting Rule for low to moderate gain hearing aids 1/3 Octave Analysis

Improved Digital Speech Digital Speech signal sometimes interfered with feedback management and other advanced features on some hearing aids Modifications have been made to improve test results New feature automatic with DIG SPCH is the selected input source

A little theory… Noise Reduction Old Method Sample from Microphone Averaging to remove noise Frequency Analysis Great for eliminating momentary noise, but a problem when testing new, complex hearing aids with feedback management and other advanced features.

New Noise Reduction with Digital Speech and Spectrum Analysis New Method Sample from Microphone Averaging to remove noise Frequency Analysis Should produce a smoother frequency response without interfering with feedback management software. Also: Smoothing has been added to Digital Speech measurements in Coupler Multicurve.

Comparison of test results using Digital Speech Version 5.01 software Version 6.00 software

New Test for Freq-Shift Hearing Aids Graph entire response of hearing aid to a pure-tone signal (default: 4000 Hz) Peak response Input signal Choose DIG FS with F4 in Coupler Multicurve Screen to perform test

DIG FS showing no frequency shift

Modified NAL-NL1 Targets Some customers have reported that NAL-NL1 targets are hard to fit with some moderate gain hearing aids Competing analyzers have version of NAL-NL1 with less gain prescription We have created a “MOD NAL” target that prescribes 3 dB per octave less gain than standard NAL-NL1 Both NAL-NL1 and MOD NAL are available in v6.00 software

Comparison of NAL-NL1 and MOD NAL NAL-NL1 standard target MOD NAL reduced target Modified formula affects both Real-ear SPL and Real-ear Insertion Gain targets Note: Audiogram used to create these targets is flat 30 dB HL

100 Hz FFT vs Third Octave Analysis 100 Hz FFT analysis

First: Thought Experiment: 100 Hz vs 50 Hz Analysis Think of the output of a frequency response as energy. Each point on the response is a “bin.” More bins = better resolution, less output per bin

100 Hz FFT Analysis vs Third Octave In Third Octave analysis, frequency response is divided into 17 different points: 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500, 3150, 4000, 5000, 6300, and 8000 Third Octave analysis has been resolution in the low frequencies and less resolution in the high frequencies due to logarithmic scaling All FONIX analyzers perform “100 Hz FFT” analysis Frequency response is divided into 79 different points that are 100 Hz equidistant (200, 300, 400… 7900, 8000 Hz) Difference between 100 Hz FFT and Third Octave analysis is 3 dB per octave

Important Notes This 3 dB per octave difference only occurs when viewing results in terms of dB SPL (coupler or real-ear). Gain measurements are not affected. This difference only occurs when using broadband signals. During a pure-tone sweep, only one “bin” is filled at a time, so the energy is not distributed.

Third Octave analysis on the FP35 analyzer Available in Real-ear SPL and Coupler Multicurve test screens.

Visible Speech Updates Speech signal input RMS Output Diamonds = Peak Pulsed Average Decay Use a connected CD player or iPod for the input signal!