We report the result of a beam test on a prototype of Astronomical hard X-ray/soft gamma-ray Polarimeter, PoGO (Polarized Gamma-ray Observer). PoGO is.

Slides:



Advertisements
Similar presentations
RHESSI Studies of Solar Flare Hard X-Ray Polarization Mark L. McConnell 1, David M. Smith 2, A. Gordon Emslie 4, Martin Fivian 3, Gordon J. Hurford 3,
Advertisements

GEANT4 Simulations of TIGRESS
Geant4 Low Energy Polarized Compton Processes Gerardo Depaola * Francesco Longo + Francesco Longo + * National University of Córdoba (Argentina) + University.
Evolving X-ray Polarimetry towards high energy and solar science Sergio Fabiani Università degli Studi di Roma “Tor Vergata” INAF / IAPS I A P S Istituto.
1 T. Mizuno et al. August 23, 2014 HEAPA Symposium on Future T. Mizuno (Hiroshima Univ.) on behalf of the SGD team and Polarization team.
GLAST The GLAST Balloon Flight experiment was performed with the collaboration of NASA Goddard Space Flight Center, Stanford Linear Accelerator Center,
The PHENEX Experiment Results in 2006 and Future Plan S. Gunji* a, Y. Kishimoto a,H. Sakurai a, F. Tokanai a, M. Kanno a, Y. Ishikawa a, Hayashida b, N.
IEEE_2007Nov.ppt Tsunefumi Mizuno 1 High Sensitivity Balloon-Borne Hard X-Ray/Soft Gamma-Ray Polarimeter PoGOLite November 2 nd, 2007 IEEE Nuclear Science.
Space Applications of Geant4 Polarized Processes F.Longo + G.Depaola * + University of Ferrara and INFN (Italia) * National University of Córdoba (Argentina)
Compton Polarimetry In Gamma-ray Astronomy Jeng-Lwen, Chiu Institute of Physics, NTHU 2006/01/12.
An accelerator beam of muon neutrinos is manufactured at the Fermi Laboratory in Illinois, USA. The neutrino beam spectrum is sampled by two detectors:
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
RHESSI Studies of Solar Flare Hard X-Ray Polarization Mark L. McConnell 1, David M. Smith 2, A. Gordon Emslie 4, Martin Fivian 3, Gordon J. Hurford 3,
1 July 8, 2008SLAC Annual Program ReviewPage Detector R&D at KIPAC Hiro Tajima Kavli Institute for Particle Astrophysics and Cosmology 1.
DOE Review (June 3, 2004) PoGO by T.Kamae 1 Large-Area Balloon-Borne Polarized Gamma Ray Observer (PoGO) DOE Review (June 3, 2004) Tune Kamae for the PoGO.
Main detector types Multi Pixel Photon Counter (MPPC) and Charge Coupled Devices (CCDs) How does it work? 1. Photon hits a pixel producing electron hole.
S. Zuberi, University of Rochester Digital Signal Processing of Scintillator Pulses Saba Zuberi, Wojtek Skulski, Frank Wolfs University of Rochester.
Seminar Author: Bojan Hiti Mentor: doc. dr. Matjaž Kavčič Determination of trace impurities on Si wafers with x-ray fluorescence.
PoGOandGlast_ ppt 1 Hard X-ray Polarimeter PoGO and GLAST mission ( 硬 X 線偏光観測 PoGO 計画と GLAST との連携 ) November 25, 2005, GLAST Science Workshop.
X-ray Polarimetry with gas proportional counters through rise-time K. Hayashida, T. Horikawa, Y. Nakashima, H. Tsunemi (Osaka University, Japan)
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
ON THE EFFICIENCY OF A LIDAR-TYPE SINGLE-SIDED GAMMA-RAY TOMOGRAPHY APPROACH Tanja Dreischuh, Ljuan Gurdev, Dimitar Stoyanov, Christo Protochristov*, Orlin.
The Hard X-ray Modulation Telescope Mission
Data Acquisition System of the PoGOLite Balloon Experiment Hiromitsu TAKAHASHI (Hiroshima University) M. Matsuoka,
ArgonneBeamTest_ ppt1 Argonne Beam Test preparation Tsunefumi Mizuno Tuneyoshi Kamae
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003.
Hard X and Gamma-ray Polarization: the ultimate dimension (ESA Cosmic Vision ) or the Compton Scattering polarimetery challenges Ezio Caroli,
2000/11/101 X-ray polarimetry experiment with balloon borne gas proportional counters K.Hayashida, H. Tsunemi, T. Koike, T. Horikawa (Osaka University),
PoGO_G4_ ppt1 Study on Key Properties of PoGO by Geant4 Simulator January 28, 2004 Tsunefumi Mizuno History of changes:
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised August 1, 2003 updated.
Hard X-ray Polarimeter for Small Satellite Design, Feasibility Study, and Ground Experiments K. Hayashida (Osaka University), T. Mihara (RIKEN), S. Gunji,
X-ray Polarimetry with gas proportional counters through rise-time
Aa GLAST Particle Astrophysics Collaboration Instrument Managed and Integrated at SLAC/Stanford University The Gamma-ray Large Area Space Telescope (GLAST)
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Monte Carlo Simulation Study of In-orbit Background for the Soft Gamma-ray Detector onboard ASTRO-H Mizuno T., Hiragi K., Fukazawa Y., Umeki Y. (Hiroshima.
GLAST The GLAST Balloon Flight experiment was performed with the collaboration of NASA Goddard Space Flight Center, Stanford Linear Accelerator Center,
STATUS OF PREPARATION OF dp-ELASTIC SCATTERING STUDY AT THE EXTRACTED BEAM OF NUCLOTRON. Yu.V.Gurchin LHE JINR September 2009.
K. Jahoda, 6 Aug 2007 X-ray School, GWU Proportional Counters Some of what you should know in order to use proportional counters for Spectroscopy, Timing,
Polarization Characteristic of Multi-layer Mirror for Hard X-ray Observation of Astrophysical Objects T. Mizuno 1, J. Katsuta 2, H. Yoshida 1, H. Takahashi.
Muon flux at Y2L and reconstruction of muon tracks
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Electron tracking Compton camera NASA/WMAP Science Team  -PIC We report on an improvement on data acquisition for a Time Projection Chamber (TPC) based.
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
1. 2 Contents The “Tsubame” Project Description of Hard X-ray Polarimeter (HXCP) Results of X-ray Beam Test Summary.
In high energy astrophysics observations, it is crucial to reduce the background effectively to achieve a high sensitivity, for the source intensity is.
PoGO_collimator_ ppt1 Study of PoGO background dependence on the collimator material/slow scintillator threshold April 21, 2004 Tsunefumi Mizuno.
PoGO_G4_ ppt1 Study of optimized fast scintillator length for the astronomical hard X- ray/soft gamma-ray polarimeter PoGO November 1, 2004 Tsunefumi.
PoGO_G4_ ppt1 Study of BGO/Collimator Optimization for PoGO August 8th, 2005 Tsunefumi Mizuno, Hiroshima University/SLAC
1 Study of Data from the GLAST Balloon Prototype Based on a Geant4 Simulator Tsunefumi Mizuno February 22, Geant4 Work Shop The GLAST Satellite.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
PoGOLiteMC_ ppt 1 Updated MC Study of PoGOLite Trigger Rate/BG January 30, 2007 Tsunefumi Mizuno (Hiroshima Univ.)
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
2001/9/111 X-ray polarimetry with balloon borne gas proportional counters K.Hayashida, H. Tsunemi, T. Horikawa, Y. Nakashima (Osaka University, Japan),
ArgonneResult_ ppt1 Results of PoGO Argonne Beam Test PoGO Collaboration meeting at SLAC, February 7, 2004 Tsunefumi Mizuno
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised.
O Tsunefumi Mizuno, Tuneyoshi Kamae, Jonny Ng, Hiroyasu Tajima (SLAC), John W. Mitchell, Robert Streitmatter (NASA GSFC), Richard C. Fernholz, Edward Groth.
Geant4 Simulation for KM3 Georgios Stavropoulos NESTOR Institute WP2 meeting, Paris December 2008.
Report of GLAST Balloon Flight October Annual meeting of Astronomical Society of Japan T. Mizuno and other GLAST Balloon Team
Solar gamma-ray and neutron registration capabilities of the GRIS instrument onboard the International Space Station Yu. A. Trofimov, Yu. D. Kotov, V.
MoNA detector physics How to detect neutrons. Thomas Baumann NSCL.
June 1, 2004 Tsunefumi Mizuno Expected Modulation Factor of PoGO calculated with Geant4 Simulator with PoGO-fix June 1, 2004 Tsunefumi.
Gamma-ray Large Area Space Telescope
AQUA-ADVANCED QUALITY ASSURANCE FOR CNAO
Sr-84 0n EC/b+ decay search with SrCl2 crystal
R. Bucˇık , K. Kudela and S. N. Kuznetsov
Application of Nuclear Physics
Detector R&D in KAPAC Outline Compton Camera SOI detector
Background Reduction for Quantitative Gamma-ray Imaging with the Electron-Tracking Compton Camera in High Dose Areas May 26th, PS10A-10 T. Mizumoto,
First demonstration of portable Compton camera to visualize 223-Ra concentration for radionuclide therapy Kazuya Fujieda (Waseda University) J. Kataoka,
Presentation transcript:

We report the result of a beam test on a prototype of Astronomical hard X-ray/soft gamma-ray Polarimeter, PoGO (Polarized Gamma-ray Observer). PoGO is a new balloon-borne instrument to measure the polarization from astrophysical objects in keV range with unprecedented sensitivity, and under development by an international collaboration including United States, Japan, Sweden and France. It consists of plastic scintillators and utilizes the design of well-type phoswich counter, providing us with a large effective area and an extremely low background. To examine the performance of PoGO to measure the polarization, we conducted a beam test on the prototype at the Advanced Photon Source Facility at Argonne National Laboratory. The detector consists of seven plastic scintillators and was irradiated by polarized synchrotron beam of 60, 73, and 83 keV. We succeeded in obtaining a clear modulation and reproducing data with Geant4 simulation within ~10%. Beam Test on Astronomical Hard X-ray Polarimeter PoGO Concept of PoGO: Abstract: (b) Beam Test at Argonne: (a) PoGO, Polarized Gamma-ray Observer, is a new balloon-borne instrument to measure the polarization from astrophysical objects in hard X-ray/soft gamma-ray band ( keV). It employs the concept of a well-type phoswich counter (Kamae et al. 1992, SPIE, 1734, 2; Kamae et al. 1996, SPIE, 2806, 314) and will achieve the unprecedented low background and high sensitivity. PoGO consists of units of plastic scintillators and determines the polarization by measuring the azimuthal angle distribution from Compton scattering. Each units is composed of a hexagonal fast plastic scintillator (detection part), collimators consisting of a slow plastic scintillator and high-Z metal, and a bottom BGO (Fig. a). Dimensions of the slow-scintillator collimator are ~2.68 cm wide and ~60 cm long, giving a narrow field of view of ~5 deg 2. Signals from scintillators are read-out by single photo multiplier tube and interactions in the fast scintillator are distinguished from interactions of others by examining the time development of the signal. These active shields and side anti BGOs reduce the background effectively (Fig b). Expected background level due to atmospheric gamma-rays is ~10mCrab in keV, where the effective area is the highest (Fig. c and d). Here, flux models developed through the GLAST Balloon Experiment (e.g., D. J. Thompson et al. 2002, IEEE Trans. Nucl. Sci. 49, 1898) are utilized. For more detail, please refer to the talk by T. Kamae and J. Mitchell. To examine the performance of PoGO and validate the Geant4-based Monte-Carlo simulator, we conducted the beam test at the Advanced Photon Source (APS) Facility of Argonne National Laboratory on November 12-18, A prototype consisting of 7 fast plastic scintillators and PMTs was used for the test (note that there is no slow scintillators nor BGOs). We irradiated polarized mono- energetic synchrotron beam of 60 keV, 73 keV and 83 keV at the center of the central scintillator (Fig. a). Polarization vector of the beam is along the horizontal axis (x-axis in the photo). beam direction x y 10us ch4 (central scintillator), compton scattering ch5 (one of ring scintillators), photo absorption (a) (b) (c) We measured the polarization by measuring the azimuth- angle asymmetry of the Compton scattering: incident beam is scattered by the central scintillator and photo- aboserbed by one of ring scinrillators. In most of the run, data acquisition was triggered by the coincidence of hits in the central scintillator (Compton scattering threshold level) and any one of ring scintillators (photo-absorption threshold level) to obtain the Compton events efficiently. While processing data, subsequent triggers were inhibited (Fig. b). Shaper outputs of 7 scintillators were digitized and recorded by a waveform analyzer. Fig. c shows a sample of obtained data for 73 keV run. (c) (d) 100mCrab (incident) 100mCrab (detected) air attenuation (4g/cm 2 ) and detector response are taken into account Background due to atmospheric gamma downward gamma upward gamma energy Flux (c/s/cm 2 /keV) 20 keV 100 keV