Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Double Wall Integrity with Single Minded Purpose!
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Introduction Design Considerations Installation Summary
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Simultaneously Extruded Double Containment Piping System The Poly-Flo System Includes a Complete Line of Molded Fittings
Poly Flo Piping System “The Double Wall Advantage” PolyFloo Double Containment Poly-Flo – The ONLY simultaneously extruded double-wall pipe system available Available in 1x2, 2x3, & 4x6 sizes Rated at F – equal to SDR17 rating Currently available in Black Polypropylene (BPP) and polyethylene (HDPE) Fittings are molded
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment MATERIALS BPP = Homopolymer Polypropylene BLACK -- UV RESISTANT HDPE = High Density Polyethylene BLACK -- UV RESISTANT
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Introduction Design Considerations Installation Summary
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Corrosion Resistance Pressure Ratings Thermal Expansion Burial Requirement Termination Assemblies Leak Detection DESIGN PARAMETERS
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment CORROSION RESISTANCE Offers Identical Chemical Resistance for Both Carrier and Containment Exceeds the 30 Day Retention Time Required by EPA Regulations
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment PRESSURE RATINGS Pipe and Molded Fittings Rated at 100 psi Drainage and Pressure Rated Flange Connections available O-Ring Flange Connections Rated at 50 psi Higher Pressure Ratings Can Be Determined Per Application
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment THERMAL EXPANSION Continuous Ribs Restrain Pipe Analysis Same as Single Wall. Continuous Construction Avoids Expansion Difficulties
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment BURIAL CONSIDERATIONS Live Loads Below 5’ Not a Factor No Limitations With Proper Burial Excellent Impact Strength
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment LEAK DETECTION Low Point Sensor (e.g. Float Switch) Zoned System (e.g. Visual Ports) External Detection (e.g. Ultrasonic)
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Introduction Design Considerations Installation Summary
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment LABOR No Spider Clips No Discs Minimal Planing
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Installations
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Double Contained Valve Box
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment TESTING RECOMMENDATIONS Test Carrier Pipe to 1-1/2 Times the Operating Pressure With H2O Test Containment Pipe With 5 psi Air to Prevent Contamination of Annular Space No Compressed Gas Above 10 psi Allowed
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment ADVANTAGES SUMMARY Quality Availability Material Cost Labor Cost Corrosion / Chemical Resistance Pressure Ratings
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Any Questions