MCI Lab & Field Testing Andrea Hansen Jessi Meyer Matt Drew.

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

Civil Engineering Materials
Hazmat Industry Technician. Types of Equipment Monitoring equipment Detection devices Air sampling systems.
Ed McLean Central US Engineer and Sales Manager CTS Cement Manufacturing.
Distress, Evaluation, and Repair of Historic Concrete Jarkko Simonen, P.E. Wiss, Janney, Elstner Associates, Inc.
DRUG TESTING 17 February Vocab Review What is the difference between a presumptive test and a confirmatory test? Presumptive tests have high false.
Measurements in Fluid Mechanics 058:180 (ME:5180) Time & Location: 2:30P - 3:20P MWF 3315 SC Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor: Lichuan.
1 Remaining Life of Concrete Sleepers: A Multifaceted Approach A/Prof Alex Remennikov School of Civil, Mining and Environmental Engineering University.
Coating Failure Analysis  An overview © KTA-Tator, Inc.
Drug Analysis.
Lecture 18. Chemical: XPS.
Lecture 8. GC/MS.
Chromatography.
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
X-ray Photoelectron Spectroscopy —— Application in Phase-switching Device Study Xinyuan Wang A
Rohrback Cosasco Systems, Inc.
I-99 Corrosion Study (Pictures in this presentation were taken from Corvib, NDT James & Fisher Scientific Websites)
Corrosion/Erosion PROCESS OUT OF CONTROL.
Chromatography and Instrumentation. Invented by a Russian Botanist Mikhail Tswett in 1903 He used chromatography to separate the colour pigments in plants.
Verifying the Use of Specific Conductance as a Surrogate for Chloride in Seawater Matrices Rob Mooney Technical Marketing Manager In-Situ ® Inc.
Comparison of Surface Resistivity to Bulk Diffusion Testing of Concrete Christopher C. Ferraro Ph.D. Assistant In Engineering Department of Civil and Coastal.
AUSTEN K. SCRUGGS CALIFORNIA STATE UNIVERSITY, FRESNO RIMI FACILITY INSTRUMENTATION.
REPAIR MANUAL Dr. Mohammed Maslehuddin Research Institute
Introduction The service life of concrete elements in highway bridges is often limited by the corrosion deterioration of reinforcing bars. In cold regions,
Types of Chromatography Liquid chromatography versus gas chromatography? Applications? Volatile  GC Non-volatile  LC.
Corrosion and Condition Assessment of Galvanized Steel Reinforcement in Concrete Structures Dr. Jane Jieying Zhang Critical Concrete Infrastructure October.
Ashkan Hashemi, Kristen M. Donnell, and Reza Zoughi
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
Engineering NDT Advanced NDE Pressure Equipment Integrity Management Lab Analysis Development of NDT Inspection Techniques For Heavy Wall Stainless Steel.
5.4 Notes.
Chemical Analysis. Analytical Techniques When chemical evidence is collected at a crime scene, it must be run through an instrument. These instruments.
NACE Corpus Christi, TX – Nace Section Meeting May 20, 2014
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
MCI: GalvaPulse Training Jessi Meyer Andrea Hansen Matt Drew.
Silver Oak College Of Engineering & Technology.
Outdoor (ISO ) and indoor (ISO 11844) classification
Chapter 13 - Analytical Instrumentation 1 Chapter 14 Analytical Instrumentation.
Concrete Maturity Method Reliable Nondestructive Method to Determine in-Place Concrete Strength.
Seminar on Concrete Damage Assessments, Concrete Repair and Concrete Mix Technology Organiser: Hong Kong Concrete Institute Co-organisers: The Hong Kong.
Intensive General Chemistry Chemical separations II Isabelle Vu Trieu
5.2 Notes Organic Analysis Pg Three chromatographic processes are used 1. Gas 2. High-Performance Liquid Chromatography 3. Thin-layer chromatography.
COLUMN CHROMATOGRAPHY
Measurements in Fluid Mechanics 058:180:001 (ME:5180:0001) Time & Location: 2:30P - 3:20P MWF 218 MLH Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor:
Practical Applications of Raman Spectroscopy for Process Analysis
Methods of Chemical Analysis. Selecting an Analytical Technique  Organic vs. Inorganic materials  Organic:  Inorganic:  Quantitative vs. Qualitative.
New Organization for Instrumental Analysis Terry A. Ring Chemical Engineering.
ENERGY AND CHEMICAL CHANGE Chapter 15. ENERGY ENERGY: -the ability to do work or produce heat. 2 different forms: potential and kinetic -Measured in.
Atomic-absorption spectroscopy
Nanometers? Tiny sensors embedded in concrete will collect physical and chemical data Presented By: Ghada Mohamed Abd ElFattah By: Deborah Snoonian, P.E.
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
5.2 Notes Organic Analysis Pg Objectives List and describe the parts of a gas chromatography Explain the difference between thin- layer chromatography.
Control Tests for Concrete Ch. 16. Project Specifications Characteristics of the mixture Maximum size aggregate Minimum cement content Characteristics.
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
Tools of the Biologist Simple Microscope- Magnifying glass Light Microscope- Using light to produce an enlarged view of the object Magnification- The ratio.
Instrumental Analysis
How long will your concrete bridge last?
GAS CHROMATOGRAPH. GAS CHROMATOGRAPH Principle: Which type of compounds can analyse? Volatile Thermostable.
Chromatography- TLC & HPLC
REMEDIAL TREATMENT OF CORRODED REINFORCED CONCRETE STRUCTURES
Monitoring Steel Corrosion Challenges
Mariusz Jaśniok Tomasz Jaśniok
SMART TEST SOLUTIONS SMART Structural Materials Audit & Responsible Testing SMART Test Solutions.
How long will your concrete bridge last?
MCI: GalvaPulse Training
Embedded Corrosion Instrument
Andrea Hansen Jessi Meyer Matt Drew
Concrete for Box Culverts – Wet Cast Concrete
Measurements & Error Analysis
Presentation transcript:

MCI Lab & Field Testing Andrea Hansen Jessi Meyer Matt Drew

Agenda Lab Testing –ASTM G109 –Modified ASTM G109 (Cracked Beam Test) –GC –XPS Field Testing –Wet Mix Testing –Alkalinity –QAC –XPS –GalvaPulse (others) –Fugitive Dye Option

ASTM G109 Standard test method for determining the effects of chemical admixtures on the corrosion of embedded steel reinforcement in concrete exposed to chloride environments.

Cracked Beam Testing Modified ASTM G109 Includes crack as part of initial test set up More true to “real life” More aggressive/faster test method

Gas Chromatography (GC) A separation technique carried out in a packed column. Each peak on the recorder signifies a certain chemical.

Gas Chromatography (GC)

X-Ray Photoelectron Spectroscopy Performed on: –MCI 2020 –MCI 2020 M –MCI 2022 –MCI 2021 Shows MCI actually absorbed onto steel reinforcement Confirmed ability of MCI to displace chlorides.

MCI Slides

XPS analysis after 450 days, Mass Concentration % Sample Etch Time (seconds) Fe 2pO 1sC 1sN 1sCl 2pCa 2pSi 2p Untreated Untreated Untreated Inhibitor A Inhibitor A Inhibitor A Inhibitor B Inhibitor B Inhibitor B

Detection of NS Admixtures in Wet Concrete HACH Silica Test Kit –Model SI-5, Ranges and 0-800mg/L “Wet samples” of concrete –Control –MCI-2005 NS or MCI NS

Gecor 6 - James Instruments Measures RH, temp, HCP, and concrete resistivity Non-destructive polarization technique 100 readings can be stored at a time Weighs 9 pounds Photo from James Instruments Inc Website

GalvaPulse - Germann Instruments Linear Polarization Resistance Half Cell Potentials Smaller and faster than Gecor 6

Galva Pulse Photo from Galva Pulse Manual

Galva Pulse Corrosion Current, µA/cm2 Corrosion Rate, µm/year Corrosion Level Time to Visible Deterioration < 0.5< 5.8PassiveN/A 0.5 to 55.8 to 58Low> 10 years 5 to 1558 to 174Moderate3 to 10 years > 15>174High< 2 years Corrosion rates by Thomas Frolund, 2002 (with GalvaPulse instrument) Chart from GalvaPulse Manual

LPR Corrator Probes - Rohrback Cosasco Systems Photo from Corrator Website Linear Polarization Resistance Electrical Resisitivity Temperature sensor

Model 800 Monitoring Devices Photos from Corrator Website Monitor via small test instruments or remote data collection More Automated CorrData Instruments

Humidity Testing ASTM-F-1869 ASTM-F-2170 ASTM-D-4263 Photo from James Instruments Website

Depth of Carbonation Deep Purple Indicator, German Instruments, Inc. Rainbow Indicator, Germann Instruments, Inc Photos from German Instruments Website

Depth of Carbonation James Instruments, Inc. Carbo Detect ASR Detect Photo taken from German Instruments Website

Sample Preparation

Alkalinity HACH Alkalinity Test –Model AL-AP MG-L –5-400 mg/L –Catalog # Alkalinity Treated > Alkalinity Control

QAC Test EM Quant Test Strips –0-500 mg/l –Cat. #

Equipment & Test Firms Test Firms American Engineering & Testing, MN H.C. Nutting, OH CTL, IL, MD, NH WJE, 20 Offices NDT Equipment Germann Instruments James Instruments Durham Geo Slope Indicator Elcometer Instruments Humboldt Manufacturing