What is being tested? (kVp, mA, mAs, mR?) What is the purpose of the HVL test? If an x-ray tube does not pass the HVL test what is done to correct the.

Slides:



Advertisements
Similar presentations
Chapter 11 Prime Factors.
Advertisements

Quality Control in Diagnostic Radiology
Chapter 18 Radiographic Exposure
Digital Radiography.
Analyzing the Image Density. Density Overall blackening of the image.
Fluoroscopy Equipment Operation
Oscilloscope. 1.Electron guns 2.Electron beams 3.Focusing coils 4.Deflection coils 5.Anode connection 6.Mask for separating beams for red, green, and.
X-RAYS IN MOTION “Viewing dynamic studies of the human body”
Photomultipliers. Measuring Light Radiant Measurement Flux (W) Energy (J) Irradiance (W/m 2 ) Emittance (W/m 2 ) Intensity (W/sr) Radiance (W/sr m 2 )
Basic Concepts of Other Imaging Modalities
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
Factors affecting the X-Ray output
X-Ray Production & Emission
X-Ray Production & Emission
Fluoroscopy Equipment
Most of the images recorded during conventional radiography are obtained with film/screen combination image receptors. Which in lessens the patient dose.
FLUOROSCOPY.
5.4.1 X-Rays. (a) describe the nature of X-rays Stowmarket Physics X-rays - nature Forms of electromagnetic radiation Short wavelength High frequency.
Quality Control Rad T 110.
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
Special Imaging Systems
Fluoroscopy Intro to EQUIPMENT
Name each component of the x-ray circuit and
FLUOROSCOPY EQUIPMENT
Quality Control.
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
Fluoroscopy Equipment. Introduction Fluoro: is dynamic radiographic examination Fluoroscopy is primarily domain of the radiologist The role of radiographer.
Control room High resolution flat screen monitors CCD image intensifiers are easily identified by their shape A modern fluoroscopic suite.
Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.
Chapter 2 The X-ray Beam.
Fluoroscopy Q&A Robert L. Metzger, Ph.D..
Angiographic facilities Tortorici Chapter 11. Designed around exam table 500 sq feet min. (25 x 20) 60 sq feet in control room Wide doors, (multiple)
Exposure Factors or Prime Factors
Appendix H: Chapter 40: Fluoroscopy
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Fluoro Equipment Review RHB Fluoro Syllabus & Rad Prot
RAD 150 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic (motion)
RAD 354 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Medical Equipment Technology Department 1 Introduction to Biomed. Imaging Systems Lecture No.5-6 Dr. Yousif Mohamed Y. Abdallah.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.04: Optimization of protection in Mammography.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Resident Physics Lectures Christensen, Chapter 2C Production of X-Rays George David Associate Professor Department of Radiology Medical College of Georgia.
RTT 425 Radiation Therapy Physics Radiation Quality, Chapter 4 From Stanton and Stinson: Applied physics for Radiation Oncology.
Tube Exposure Factors Math Technique Contrast and Density
Introduction By Dr. Nimer Khraim DVMS,BVMS,MVSc.
Sergeo Guilbaud School of Radiologic Sciences
FLUOROSCOPY & IMAGE INTENSIFICATION Sergeo Guilbaud, RT School of Radiologic Sciences.
IAEA International Atomic Energy Agency Fluoroscopy Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(2)
3 July July July Conventional X-rays Generator Basic components of an X-ray machine:  Electron source.  Vacuum where electrons were.
Exposure Factors or Prime Factors
Patient is placed between X-ray tube and silver halide film.
Resident Physics Lectures
Oscilloscope.
IMAGE ORTHICON.
X-Radiation.
Stacy Kopso, M.Ed., RT(R)(M)
Fluoroscopic Unit Thomas Edison 1896.
Equipment Operation and Maintenance
Resident Physics Lectures (Year 1)
Resident Physics Lectures
Fluoroscopic Brightness Control Systems
Fluoroscopic Image Intensifier Image production
Resident Physics Lectures (Year 1)
Flouroscopic imaging.
Fluoroscopic Image Quality Considerations
Fluoroscopic Image Intensifier Image Production
Fluoroscopic Image Quality Considerations
Brightness Control Systems
Presentation transcript:

What is being tested? (kVp, mA, mAs, mR?) What is the purpose of the HVL test? If an x-ray tube does not pass the HVL test what is done to correct the deficiency? Can the results of this test be applied to all values up to 118? These 12 slides highlight the material from chapters 10, 12, and 40, of test #3. Along with the PowerPoint reviews for Tests 1 and 2 this completes the reviews by illustrations for the comprehensive final.

* What is the name of each of these interactions? * What energy level do each of these interactions occur at? * Of what significance (positive or negative) are each of these interactions? * What characteristics do each possess? - what part of the atom is involved? - is there ionization?

* What is the name of each of these interactions? * What energy level do each of these interactions occur at? * Of what significance (positive or negative) are each of these interactions? * What characteristics do each possess? - what part of the atom is involved? - is there ionization?

4. How is this graph different than the one above? #1. What effect is this? #2. What effect is this? 3. What does this graph tell us about these effects?

* Fluoro mA is 5 or less * Due to the length of exams patient dose is high * kVp is dependant on part thickness * Automatic Brightness Control (ABC) maintains the density when the fluoroscope is moved across varying thicknesses by adjusting the mA

Image Intensifier (II) Input Phosphor CsI Photocathode Cesium & Antimony Glass envelope Electrostatic focusing lens Output Phosphor Zinc Cadmium Sulfide Anode 25,000 V Concave surface so all electrons arrive at the output screen at the same time, but causes vignetting.

The transfer of energy through the fluoroscopic imaging chain Focal Point

Flux Gain Photocathode Electrostatic focusing lens Output Phosphor (zinc-cadmium sulfide) Anode 25kV + potential Electrons accelerated across the tube gain kinetic energy from the attractive force of the anode (conversion efficiency). The collision at the output screen liberates that energy in the form of more light photons

Minification Gain Input Phosphor (CsI) Output Phosphor (zinc-cadmium sulfide) The ratio of the areas of the input and output screens is expressed as the minification gain. 1” diameter 9” diameter = 81 times

Total Brightness Gain The product of the flux gain and the minification gain is the total brightness gain. If the flux gain were 70, and the brightness gain x 81 = 5670 total brightness gain ,000 is the range

Quantum Mottle Because the image intensifier makes the image on the output screen thousands of times brighter than the image on the input screen, much less radiation is needed. If too few photons are used, the image becomes grainy and unacceptable for diagnostic purposes. Generally speaking a better image is always obtained by using more photons, but the price is paid in patient dose. Conversion factor The intensity of illumination at the output phosphor (candela per meter squared) to the radiation intensity that produced it (mR/s) Typical conversion factors of 50 to 300 relate to the ,000 BG

A B H D C G E F K J I L Test Image