Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways G. Bonnier, 1974
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways Main faults: -Sensitive to pressure change (atmospheric + hydrostatic) - Immersion condition changing with time Main advantages: - Simple to use - No electronic devices
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways Sensitive to atmospheric and hydrostatic pressure changes ? Solution ? Sensitive to atmospheric and hydrostatic pressure changes ? Solution ?
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways Sensitive to atmospheric pressure changes ? Solution ?
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways 1990 : The argon triple point by an adiabatic method –INM internal report
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways 1990 : The argon triple point by an adiabatic method – F. Roussel – INM internal report
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways Main faults: - Not so easy to use - Immersion condition changing with time Main advantages: - non sensitive to pressures changes
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways How to improve the immersion condition Not useful ? N 2 heat pipes Argon gas Liquid argon 1985
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways How to improve the immersion condition 1985 : the argon triple point: Study of the thermal conditions –INM – internal report
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways How to improve the immersion condition 1990 : An adiabatic calorimeter for calibration at the argon triple point – INM- Tempmeko90
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways How to improve the immersion condition Maintaining the guard cell
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways How to improve the immersion condition 2002 – “Argon Triple Point Device to Calibrate Long Stem Thermometers in Quasi Adiabatic Conditions” “Temperature” chicago
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways How to improve the immersion condition
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways How to improve the immersion condition
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways Future ways ? Main faults on the “actual” system -Sensitive to pressure change (atmospheric + hydrostatic) - Immersion condition changing with time Pressure regulation : Reference: vacuum or temperature?
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways Future ways ? Our choice Pressure regulator thermometer
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways Future ways ? Main faults on the “actual” system -Sensitive to pressure change (atmospheric + hydrostatic) - Immersion condition changing with time Level of liquid nitrogen ?
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways Future ways ? Our choices Pressure regulator Insulations thermometer Liquid nitrogen
Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, Past Improvements of the INM type Argon Device and Future Ways Future ways ? Our choices Pressure regulator Liquid nitrogen Filling tube Guard cell Experimental space (vacuum) Thermal shield Main cell