Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen,

Slides:



Advertisements
Similar presentations
Prosthetic Technology
Advertisements

Force Sensitive Resistor October 19th, 2009 Johnnie Chang.
TF SOCKET BIOMECHANICS
The Knee Joint.
Changing Seasons “The hardest thing about learning something new, is unlearning the way you know it now.”
Formal Design Review Team 4 Limb-itless Chris Bruce, Anna Chen, Grant Hofmeister.
Amanda Neves URI Biomedical Engineering.  Fit of the prosthesis is extremely important for the comfort of the limb and prevent skin irritation or pain.
This slide to be displayed before Webinar begins.
Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen,
Ankle-Foot Orthoses (AFOs)
Seating and Positioning. Let’s talk about Safe walking first.
SKIN INTEGRITY SHARON HARVEY 23/03/04. LEARNING OUTCOMES THE STUDENT SHOULD BE ABLE TO:- ILLUSTRATE THE STRUCTURE AND FUNCTION OF MAJOR COMPONENTS OF.
1 Embedded Stroke Evaluation System Amanda Sweeney, 4ECE Supervisor: Martin Glavin.
QUICK TIPS (--THIS SECTION DOES NOT PRINT--) This PowerPoint template requires basic PowerPoint (version 2007 or newer) skills. Below is a list of commonly.
Position Sensing Glove Barbara Tuday Nathan Schreppler Lauren McIlwain Michael Nolan Team 6:
SKIN INTEGRITY AND WOUND CARE
Current and Resistance
INTRODUCTION - REMOVABLE PARTIAL DENTURE
Shear Definitions, Relationships and Measurements Geoff Taylor – VP Research and Development, Vista Medical Inc. Winnipeg Canada.
Seminar/seminar /ming.ppt 1 Tacking the challenges to professional education arising from the pace of technological development and the need for.
MSD-I Project Review Modular Motion Tracking Sensors 1.
INTELLIGENT ROBOT WALKER. AVAILABLE DEVICES The PAM-AID Reactive device Basic obstacle avoidance Not supportive more an aid for the blind The SMARTCANE.
Support Surfaces Laura E. Edsberg, Ph.D.. Overview Effects of Pressure on Tissue Support Surfaces Testing Support Surfaces.
Dan Damon Kevin Hampton Christine Lee Shane Siwinski ADVISOR: Professer Lin SPONSER: General Motors.
Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen,
Chapter 22 Alternating-Current Circuits and Machines.
Chapter 27 Lecture 12: Circuits.
Intervensi Ortotik Prostetik Pada Diabetik Foot IOPI Konferense Solo 2010 Markku Ripatti.
ACTIVMOTION.
An Opening in the Abdomen An Opening in the Market: Hernia Tensiometer GROUP 2: Martha Ingram Megan Johnston Chelsea Samson.
Dr. Waseem Bahjat Mushtaha Specialized in prosthodontics
Embedded Stroke Evaluation System Amanda Sweeney, 4ECE Supervisor: Dr. Martin Glavin.
Field Measurement of Running Impacts Team: Chelsea Wanta, Amanda Feest, Matt Kudek, Nicole Daehn, Lindsey Carlson BME 201 March 9, 2007 Client: Dr. Bryan.
Multi-Chamber Programmable Air Cushion (MC-PAC) Joli-A Kabamba Masahiro Ohno Scott Paik Joe Suarez.
Track & Field: Warm-up, Stretching, & Flexibility
Wheelchair Seating and Positioning Sarah Crosbie, MS.Ed, OTR/L.
OBJECTIVE Without reference, identify at least four out of six principles pertaining to the application of transducers related to patient care.
Improved Lower Limb Prosthesis
Quantitative Detection of Parkinson's Disease Symptoms Advisor: Dr. Chris Kao Project Team: Kylen Bares Eddie Cao.
Chapter 27 Lecture 24: Circuits: II HW 8 (problems): 26.10, 26.22, 26.35, 26.49, 27.12, 27.30, 27.40, Due Friday, Nov.6.
Elevated Vacuum Suspension
Disposable Mattress Cover with Conductive Threads to Detect Wetness using Resistance Comparison ECE 4884 L03 Advisor: Dr. Koblasz Team Members: Ankit Hemani.
Unconstrained Sleep Measuring Device for Breathing Movement 非穿戴式睡眠呼吸運動量測裝置 Presenter: Kun-Han Jhan Advisor: Dr. Chun-Ju Hou Date:2013/12/25.
Arm as Good as New Ethan Leavell Sulamita Staroverova Jalen VanTrease Tolu Amudipe.
Biomechanical Tissue Stimulator Group 1: Matt Brady (BME/EE) Ankeet Choxi (BME) Misha Kotov (CS) Steven Manuel (ME) Adviser: Dr. V. Prasad Shastri.
Targeted Muscle Reinnervation for Control of Myoelectric Arm Prostheses By. Rory Makuch.
Part 1: Assessment for Prosthetic Use & Stump Management.
PROSTHETIC LEG PRESENTED BY:-AWAIS IJAZ HASNAT AHMED KHAN.
Project Update Limb-itless Chris Bruce, Anna Chen, Grant Hofmeister February 22, 2007.
BRACE & LIMB LABORATORY. Processes of making a Transtibial prosthesis.
Mass Flow Sensor Integration Team 5: Beau Rodgers Luis Mendez Brian Roberts Keenan Cheeks Sponsored by: Danfoss Turbocor Advised by: Dr. Shih.
BY Parmar Anjali Singh Sweta
Chapter 42 Lower Extremity Amputation
Assessment of Soft Artificial Skin with Pressure Sensibility Southeastern Louisiana University.
Assessment of Soft Artificial Skin with Pressure Sensibility Southeastern Louisiana University.
Hemostatic Compression Device Jill Doyle Reed Gioe Christopher Miller Aut Singhchinsuk.
Prosthesis in Transtibial Amputation
In and Out Line Monitoring System for Volleyball
Musculoskeletal Care SrA Heintzelman.
Knee.
Prosthetic limbs.
Date of download: 10/25/2017 Copyright © ASME. All rights reserved.
Christine Bronikowski, Amanda Chen, Jared Mulford, Amy Ostrowski
The Knee Joint.
Assessment of Soft Artificial Skin with Pressure Sensibility
Notes Ch. 8a Joints of the Skeletal System
How can we change the current in a circuit?
Assessment of Soft Artificial Skin with Pressure Sensibility
Presentation transcript:

Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen, Jared Mulford, Amy Ostrowski Advisor: Aaron Fitzsimmons, The Surgical Clinic

Problem Statement Lack of research in the socket interface between the artificial limb and the residual limb, specifically force profiles ▫ Majority of research based on models with historically proven success and qualitative assessments

Current Process for Constructing a Transtibial Socket 1.Transtibial Patient Evaluation a.Limb measurements b.Skin type and integrity c.Range of motion d.Hand dexterity e.Fine and gross motor skills f.Cognition 2.Gel Liner Interface Material Selection a.Most common: Urethane, thermoplastic elastomer, silicone 3.Fit Gel Liner to Patient

Current Process for Constructing a Transtibial Socket (cont.) 4.Cast and measure over gel liner 5.Modify negative model a.Computer modeling b.Hand modification 6.Fabricate positive check socket 7.Fit positive check socket – static and dynamic assessments 8.Fit final laminated socket

Current Socket Designs Designed on a case-by-case basis for individual patients

Problems with Current Models ▫Skin abrasion ▫Pain or discomfort ▫Tissue breakdown at the skin surface and within deep tissues ▫Pressure ulcerations and resultant infections at the socket interface Many of these problems arise from forces at prosthetic interfaces

Project Goals Acquire accurate measurements of perpendicular forces acting on the residual limb of transtibial amputee during various movements Pinpoint regions with highest forces Design a socket system in which forces are optimally distributed throughout the residual limb-socket interface Increase overall patient comfort

Forces Acting on the Limb Shear– resulting from frictional forces between skin and socket ▫Can be minimized using socket liners Perpendicular

Method of Force Analysis Force Sensing Resistor (FSR) placed between liner and socket Very thin– will not cause variation in force determination Decrease in resistance with increasing force, which leads to increasing output voltage

Circuit Design Circuit design: current to voltage converter Vout=Vref*(-RG/RFSR)

Circuit Design

Placement of FSRs Impractical to cover every area of the residual limb with sensors One FSR used in each area of clinical interest, 9 total Pressure Tolerant Patellar tendon Medial tibial flare Mid shaft of fibula Medial tibial shaft Pressure Sensitive Distal end of tibia Distal end of fibula Fibular head Anteromedial tibia Hamstring tendons

Design/Safety Considerations Wire thickness ▫Thin enough to prevent interference with force data ▫Thick enough to remain durable during movement FSR-wire connection ▫Must not break during testing Transportability ▫Must move from treadmill to ramp area quickly Power Supply

Preliminary Trial at The Surgical Clinic

Recent Work Alterations based on the preliminary test ▫FSRs reinforced with nonconductive epoxy ▫Circuit rebuilt ▫Transportable Encasement Prosthetic leg testing Voltage calibration Drift correction NI LabVIEW / RIO

Current Status Preparing to test with Cody on Friday, Feb. 11th Developing LabVIEW module to record data Attempting to get in contact with Dr. Robinson Calibrating Voltage – Force curve

Future Work Conduct trials with additional patients ▫Test on multiple surfaces (incline, flat, stairs) Analyze results, determine regions containing peak forces Test several different types of sockets with Cody Design and develop new socket: provide more cushioning in areas of greatest force Determine success from patient feedback and peak force reduction in critical regions

References