WP 5: Diagnostics Coordinator: Grahame Blair CFBPMConfocal Resonator BPM. LBPMLaser-based Beam Profile Monitor PBPMPrecision Beam Position Monitor ESPEC.

Slides:



Advertisements
Similar presentations
BPM Energy Spectrometry for ILC Bino Maiheu University College London for LC-ABD WP 4.2 LC-ABD Meeting IPPP Durham, 26 September 2006 LC-ABD Meeting, 26.
Advertisements

Energy spectrometer cavity BPM Royal Holloway, University of London S. Boogert, G. Boorman University of Cambridge M. Slater, M. Thomson & D. Ward University.
BPM Energy spectrometry, status & future plans at ESA in SLAC Bino Maiheu University College London Yerevan Collaboration Meeting October 2006 Yerevan.
LCABD WP 4.2 Review, 12 th April Mark Slater  Motivation  BPM and Electronics Development  BPM Simulation  Update on NanoBPM Progress  Update.
Fast and Precise Beam Energy Measurement at the International Linear Collider Michele Viti.
Cavity BPM for Spectromety: progress and plans A. Lyapin.
Latest laser-wire results ● How does a Laser-Wire work? ● Latest ATF results ● Focusing optics ● Latest PETRA results University of Oxford: Nicolas Delerue,
Beam position monitors LCABD Plenary meeting Bristol, 24th March 2009 A. Aryshev, S. T. Boogert, G. Boorman, S. Molloy, N. Joshi JAI at Royal Holloway.
WP 4.2 review meeting Status of the ESA work... Wednesday, 13 September 2006, UCL,
Beam Loss Analysis Tool for the CTF3 PETS Tank M. Velasco, T. Lefevre, R. Scheidegger, M. Wood, J. Hebden, G. Simpson Northwestern University, Evanston,
European Design Study Towards a TeV Linear Collider WP 2 : Beam Delivery System Co-ordinator: Deepa Angal-Kalinin CCLRC, Daresbury Laboratory.
-brief report of October runs and some inputs for the Nov/Dec planning – Nobuhiro Terunuma, KEK, ATF ATF session on LCWS13, Tokyo Univ., Nov. 13, 2013.
Progress towards nanometre-level beam stabilisation at ATF2 N. Blaskovic, D. R. Bett, P. N. Burrows, G. B. Christian, C. Perry John Adams Institute, University.
M. Woods (SLAC) Beam Diagnostics for test facilities of i)  ii) polarized e+ source January 9 –11, 2002.
High Resolution Cavity BPM for ILC final focal system (IP-BPM) ILC2007/LCWS 2007 BDS, 2007/6/1 The University of Tokyo, KEK, Tohoku Gakuin University,
Beamdiagnostics by Beamstrahlung Analysis C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
1 Fabry-Perot cavity & pulsed laser J. Bonis, V. Brisson, J.N. Cayla, R. Chiche, R. Cizeron, J. Colin, Y. Fedala, G. Guilhem, M. Jacquet-Lemire, D. Jehanno,
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
12/12/04 1 Stewart Boogert (UCL) Second Mini-workshop Nano project at ATF UK plans for Energy spectrometer studies University College London Stewart Boogert.
___________________ Jürgen Schreiber, ECFA/DESY LC workshop, Amsterdam, April 1-4, 2003 BEAM ENERGY SPECTROMETER DESY – Dubna – TU Berlin Machine physicists,
UK/EU Plans for ATF2 G.A. Blair ATF2-IN2P3-KEK kick-0ff meeting, Annecy, 8 th October 2006 Overview EUROTeV UK.
WP9 : Cavity BPM spectrometry Royal Holloway S. Boogert & G. Boorman University College London D. Attree, A. Lyapin, B. Maiheu & M. Wing Cambridge University.
BPM-Based Energy Spectrometer Contributors: A. Lyapin, B. Maiheu, F. Gournaris, D. Attree, M. Wing, D. Miller University College London (UCL) M. Slater,
Luminosity Monitoring and Beam Diagnostics FCAL Collaboration Workshop TAU, September 18-19, 2005 Christian Grah.
Laser Wire: :LBPM G A Blair EUROTeV Scientific Workshop, Uppsala 27 th August 2008 Introduction Emittance extraction Experimental programme Laser R&D Summary.
Analysis of Beamstrahlung Pairs ECFA Workshop Vienna, November 14-17, 2005 Christian Grah.
ATF1/2 laser-wires Stewart T. Boogert on behalf of UK Extraction line laserwire collaboration A. Aryshev, G. Blair, S. Boogert, A. Bosco, L. Corner, L.
TBL as a 12 GHz power source, overview and first results from commissioning IWLC 2010 workshopSteffen Döbert, BE-RF  Current status of TBL  Status of.
1 C. Simon CLIC Instrumentation workshop BPM C. Simon on behalf of the Saclay’s group CLIC Instrumentation workshop 2 nd - 3 rd June.
Energy Spectrometer for the ILC Alexey Lyapin University College London.
Feedback On Nanosecond Timescales (FONT): Robert Apsimon, Philip Burrows, Neven Blaskovic, Douglas Bett, Glenn Christian, Michael Davis, Davide Gamba,
Development of a Low-latency, High-precision, Intra-train Beam Feedback System Based on Cavity Beam Position Monitors N. Blaskovic Kraljevic, D. R. Bett,
The beam-based alignment and feedback systems, essential operations of the future colliders, use high resolution Beam Position Monitors (BPM). In the framework.
Results on recent technology developments at ATF - Beam extraction study by a Fast Kicker - N. Terunuma, KEK LER11, Heraklion, Crete, Greece, 2011/Oct/5.
CLIC meeting 09/ Lars Søby, CERN AB/BDI1 PBPM: Precision Beam Position Monitor. WBCM: Wide Band Current Monitor. EUROTeV Diagnostics WP5
Fast Beam Diagnostics at the ILC Using the Beam Calorimeter Christian Grah, Desy FCAL Workshop February Cracow.
Production and Installation Policy of IP-BPM ATF2 Project Meeting, 2006/12/18 Y. Honda, Y. Inoue, T. Hino, T. Nakamura.
CLIC09 Workshop October 2009Drive beam BPM’sLars Søby 1 Drive Beam BPM’s CLIC 09 work shop, CERN, of October 2009, Lars Søby.
1 EuroTeV High Bandwidth Wall Current Monitor Alessandro D’Elia CERN- Geneve.
1 EuroTeV High Bandwidth Wall Current Monitor Alessandro D’Elia AB-BI-PI.
CERN, 27-Mar EuCARD NCLinac Task /3/2009.
BPM for FF test (ATF2) Vladimir Vogel KEK 2nd Nano Workshop, KEK, December 12, 2004.
SLAC ESA T-474 ILC BPM energy spectrometer prototype Bino Maiheu University College London on behalf of T-474 Vancouver Linear Collider.
Plans for Laser-wire System Grahame Blair 21 st June 2005 Brief overview of UK LW programme ATF Extraction line LW Plans for this year ATF2.
ATF2 beam operation status Toshiyuki OKUGI, KEK The 9 th TB&SGC meeting KEK, 3-gokan Seminar Hall 2009/ 12/ 16.
ATF2: Laser-wire Scheduling Strategy Grahame Blair Current Status Funding application Possible Scheduling Strategy Second ATF2 Project Meeting, KEK, 31.
Summary of Tuning, Corrections, and Commissioning ( Short summary of ATF2 meeting at SLAC in March 2007 ) and Hardware Issues for beam Tuning Toshiyuki.
Diagnostics Workpackage G A Blair EUROTeV Final Meeting, DESY, Hamburg 30 th January 2009 Tasks Summary.
1 Feedback On Nanosecond Timescales (FONT): Philip Burrows Neven Blaskovic, Douglas Bett, Glenn Christian, Michael Davis, Young Im Kim, Colin Perry John.
September 2007SLAC IR WS Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY Talks by M. Morse, W. Wierba, myself.
Development of a High Resolution Cavity BPM for the CLIC Main Beam
FP7: EuCARD after a year of preparation… A.Jeremie.
High precision phase monitoring Alexandra Andersson, CERN Jonathan Sladen, CERN This work is supported by the Commission of the European Communities under.
Instrumentation at ATF / TTF Accelerator Test Facility (KEK) Tesla Test Facility – FLASH (DESY) ESA / LCLS (SLAC) Marc Ross, SLAC.
Very Forward Instrumentation: BeamCal Ch. Grah FCAL Collaboration ILD Workshop, Zeuthen Tuesday 15/01/2008.
Task 9.4 Beam Delivery System CERN, 27-Mar /3/2009
EUROTeV Diagnostics WP5
Phase Feed-Forward Piotr Skowroński (CERN)
LCABD WP 4.2 – Spectrometer and BPM Studies
CLIC Workshop 2016: Main Beam Cavity BPM
Plans for Laser-wire System Grahame Blair 30th May 2005
CLIC-ILC BDS & MDI work.
Diagnostics Summary G. Blair RHUL 23rd June 2005
ATF nanoBPM system - nanoGrid ATF2 Movers TTF HOM – dipole / monopole
    BEAM POSITION MONITORS USING A RE-ENTRANT CAVITY C. Simon1, S. Chel1, M. Luong1, P. Contrepois1, P. Girardot1, N. Baboi2 and N. Rouvière3.
Intra-Pulse Beam-Beam Scans at the NLC IP
Beamdiagnostics by Beamstrahlung Pair Analysis
Feed forward orbit corrections for the CLIC RTML
Detecting phase Alexandra Andersson Jonathan Sladen
Presentation transcript:

WP 5: Diagnostics Coordinator: Grahame Blair CFBPMConfocal Resonator BPM. LBPMLaser-based Beam Profile Monitor PBPMPrecision Beam Position Monitor ESPEC Precision Energy spectrometry HEPOLPrecision High Energy Polarimetry. TPMONTime and Phase Monitor WBCMWide Band Current Monitor FLUM Fast Luminosity Monitoring EUROTeV Annual meeting, Cockcroft Institute / Daresbury, 9 th January 2007

CFBPM: Nearly Confocal Resonator

High Power LASER 2D LW scanner at PETRA Free space Beam Transport (~ 30m) Laser rep rate = 20 Hz pulse width 6 ns Laser spot-size ~ 12 um e- spot size 50 – 200  m Scanning device: Piezo-mirror max speed 100 Hz Post IP Imaging System aligned for both dimensions for real time laser size monitoring Automatic beam finding Translation stages 2D scan through automatic path selection Lens f=250mm LBPM: Laser-wire contact: G. Blair (RHUL)

Seeded (100 steps, 1 point per step) 100/20Hz = 5 sec Seeded (100 steps, 10 points per step) 1,000/20Hz = 50sec Sigma ~ 49um Seeded (100 steps, 100 points per step) 10,000/20Hz = 500sec Sigma ~ 46um

ATF Laser-wire

PBPM: Precision BPM L. Soby, I. Podadera Aliseda, CERN On Schedule Final Design Complete Electronics design Electromagnetic simulation Resolution:100 nm. Aperture: 4-6 mm. Absolute precision: 10 mm. Rise time: 15 ns.

Daresbury- European LC workshop PBPM- deliverables Prototype PBPM (100nm resolution): Design and build prototype. (end December 2006) Report on bench tests: Design and build a mechanical stable test bench. Develop front end electronics. Measure PBPM prototype. (middle 2007) Report on beam tests: Build 3 PBPM’s for beam tests at CTF3 or ATF-2 beam. (end 2007) EUROTeV report prepared and to be published DONE!

WCM: wideband current monitor L. Soby, Alessandro D’Elia - CERN The 3 rd generation of CLIC Test Facility (CTF3) foresees a beam formed by bunches separated by  b = 67 ps WCM h. f. cut-off = 20 GHz for a total pulse duration of  r = 1.54 µs WCM l. f. cut-off = 100 kHz  9 GHz

WCM Conclusions The test bench has been improved The new proposed geometry at the cost of few changing in the old one shows a quite good response for our aims: apart of the TM01 mode at about 5.5 GHz a quite good flat response it is foreseen up to 25 GHz with the possibility of extending the bandwidth up to 30 GHz for future applications More accurate studies on the real feedthrough are needed Development of a new testbench only for feedthrough Feedthrough vacuum leakage Reliable ferrite and SiC models in CST MicroWave and/or HFSS We are confident, on February, of producing a preliminary mechanical design

ESPEC: Energy Spectrometer D. Ward, M. Thomson, M. Slater (Cambridge) S. Boogert, G. Boorman (RHUL) F. Gournaris, A. Liapine, B. Maiheu, D. Miller, M. Wing (UCL) and International Collaborators T474/T491 at ESA January 2006 test run (4 days): commissioning BPMs 31,32 and 1,2 upstream April 2006 run (2 weeks): o Commissioning new ILC prototype linac BPMs (3,4,5) where 4 is on a (x,y) mover system o Commissioning old SLAC BPMs (9,10,11) o Digitisation/signal processing optimisation July 2006 run (2 weeks): o Commisioning Zygo interferometer system (3,4,5) + BPM24 upstream o Further optimisation of hardware o Stability data taking with 10 BPMs, frequent calibrations 20 m SPEAR girder Dipole magnets BPMs 3,4,5 BPMs 9,10,11

ESA results: resolution and stability ~30 mins. prototype, BPM3-5 ~700 nm old cavities, BPM9-11 ~350 nm

Spectrometer-specific BPM Existing BPM designs are not optimal for an energy spectrometer aperture (machine protection) resolution, stability monopole rejection coupling → decay time Take know-how gained from collaboration work and design a BPM suitable for an energy spectrometer. Al model and Cu vacuum prototype 30 mm aperture, GHz theoretical resolution ~ 11.2 nm Mover system Horizontal stage: 2” travel range, 15  m Vertical stage: 5 mm travel range, 10  m accuracy Electronics box almost complete

100 fs Pulsed laser 500 MHz or 5 MHz 10 nJ/pulse Fabry-Perot cavity with Super mirrors Energy gain 10 4 Electron beam Laser amplification cavity for ILC polarimeter 1.Resonance of a high gain Fabry-Perot Cavity with a fs laser 2.Realization of a specific confocal cavity Orsay HEPOL: Contact: Fabian Zomer J. Bonis, V. Brisson, J.N. Cayla, R. Chiche, R. Cizeron, J. Colin, Y. Fedala, G. Guilhem, M. Jacquet-Lemire, D. Jehanno, L. Losev, R. Marie, K. Moenig, V. Soskov, C. Sylvia, A. Variola and F. Zomer LAL-Orsay & Lebedev Inst.-Moscow

All optical elements/lasers are mounted and operational Feedback electronics Tests of hardware & programming tools : Completed Feedback system inserted in the optical bench  test of the locking on a low finesse cavity almost completed

Four mirror ‘bow tie’ cavity Cheap laser= laser diode 1st Prototype for studying mode structures and beam waist Built in the LAL workshop

Schedule for 2007 Step 1: manpower problem solved –1.5 FTE more for analog electronics (starts Jan.-Feb. 2007). –First results for high finesse (Gain=10 4 ) expected mid- 2007, very high finesse (Gain=10 5 ) at the end of 2007 Step 2: progressing –End of the mode structure studies for non-planar bow-tie cavity expected in spring 2007 –Study of the length control of such cavity will start in Feb Step1+Step 2 would require one more year… –Possible experimental implementation at ATF

TPMON Aim The aim of the task is to investigate the feasibility of a precision bunch train timing measurement at 30 GHz, with an accuracy of 10 fs, and a bandwidth of at least 50MHz. Tests of the electronics have begun at CERN’s CTF3. Requirements Phase accuracy: 0.1º Amplitude range: ~6dB Bandwidth: 50MHz, system investigated up to 250MHz Precision beam phase measurement Contact: Jonathan Sladen Alexandra Andersson (CERN) CTF3 Results: noise for two systems promising at both 250MHz and 50MHz

Work to be completed: ● Complete static correction algorithm to correct amplitude dependent phase offset ● Develop a dynamic correction algorithm to correct step response of the system ● Characterise temperature drift ● Improve calibration routine ● Hardware modifications of down converters ● Further beam tests

Geometry for the new ILC baseline of 14mrad changed LumiCal and BeamCal acceptance moved LumiCal to smaller z-position centered BeamCal and LumiCal around the outgoing beam need uninstrumented area for the incoming beam FLUM: Fast Luminosity Monitor C. Grah (DESY)

Beam Parameter Reconstruction Beamparameters vs Observables slopes (significance) normalized to sigmas 14mrad antiDID Sensor prototype sector Readout Scheme for BeamCal

Summary and Outlook  The geometry of the forward region was adjusted to the case of a large crossing angle.  We investigated the impact of a change in the segmentation on the electron veto efficiency. 0.8 R M is still good and reduces the total channel number.  Tested the fast beam parameter reconstruction for 2, 14 and 20 mrad configurations with DID/AntiDID field.  A Geant4 simulation of BeamCal (BeCaS) is ready for use. It is fast enough, so that we do not need a shower parametrization.  First tests show that a subset (some layers) of the detector information seems sufficient for beam parameter reconstruction.  Complete/optimize observable definition and include digitization.  Complete 14mrad study  Use the Real Beam simulation data.  GamCal could provide valuable information about the collision –partly complementary to BeamCal information –E pair /E γ is a signal proportional to the luminosity for several beam parameters

DIAG work package includes a range of systems important to the ILC. All tasks are now in “full steam” and are highly productive Lots of interplay with the other WPs Lots of activity – groups and hardware are in place/being delivered and tested with beam. WP5 Summary