SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA TIPS: STIS Report Paul Goudfrooij 1.Unusual Target ACQ Failures: Update & Resolution 2.Calibration.

Slides:



Advertisements
Similar presentations
A NEW CTE PHOTOMETRIC CORRECTION FORMULA FOR ACS Marco Chiaberge TIPS meeting 05/16/2012.
Advertisements

Spectroscopic Data ASTR 3010 Lecture 15 Textbook Ch.11.
Post-SM4 Sensitivity Calibration of the STIS Echelle Modes Azalee Bostroem With help from: Ralph Bohlin, Alessandra Aloisi, Charles Proffitt, Kenneth Hart,
Spectroscopy of Saturn
Echelle spectra reduction with IRAF*
STIS 1 ST Order Spectroscopic Point Source Flux Calibration Charles R. Proffitt STScI and CSC.
Naoyuki Tamura (University of Durham) Expected Performance of FMOS ~ Estimation with Spectrum Simulator ~ Introduction of simulators  Examples of calculations.
NICMOS IntraPixel Sensitivity Chun Xu and Bahram Mobasher Space Telescope Science Institute Abstract We present here the new measurements of the NICMOS.
S. Baggett, J. Anderson, K. S. Long, J. W. MacKenty, K. Noeske, J. Biretta, and the WFC3 team (STScI) WFC3 : Understanding and mitigating UVIS charge.
1 TIPS 2011 May Persistence in the WFC3 IR detector Knox S. Long.
Background information for users of STIS Charles R. Proffitt.
CCDs in space: the effects of radiation on Hubble’s Advanced Camera for Surveys (ACS) Max Mutchler, David Golimowski (Space Telescope Science Institute),
STIS Closeout Plan Paul Goudfrooij 2005 HST Calibration Workshop, 10/26/2005.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA TIPS / COS TV Update 21 December 2006 Agenda Agenda Testing Setup and Status Testing Setup.
Cosmic Origins Spectrograph Hubble Space Telescope James C. Green University of Colorado Cosmic Origins Spectrograph Instrument Design and Capabilities.
CCD Detectors CCD=“charge coupled device” Readout method:
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA COS Status FUV Detector “1-bounce design” NUV Detector HST aberration fully-corrected Calibration.
Figure 8.Color map of the geometric correction along the dispersion axis for segment A. Figure 4. Measured distortions for all PSA positions for segment.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA Hubble Mission Status Review Charles D. (Tony) Keyes Last Review: 10 June August 2003.
TIPS COS Overview - Keyes : 18 May 2000 COS Overview v CDR: April 2000 v FUV delivery: January 2001 v Environmental (Thermal-Vac): spring 2002 v Launch:
JWST Calibration Error Budget Jerry Kriss. 15 March 20072/14 JWST Flux & Wavelength Calibration Requirements SR-20: JWST shall be capable of achieving.
STIS CCD: Housing Temperature, Darks, and Charge Transfer Inefficiency Michael A. Wolfe June 17, 2010 Co-Investigators: W. V. Dixon, P. Goudfrooij, T.
Selection of the New COS/FUV Lifetime Position Cristina Oliveira Jan TIPS Meeting - COS/FUV Lifetime1.
WFPC2 UPDATE TIPS : August 15, 2002 L.M. Lubin New WFPC2 Documentation 1.Cycle 12 Instrument Handbook (V7.0, Biretta et al.)  Updated information on the.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA COS Pipeline Calibration Outline of CALCOS Processing Steps and Keywords Reference Files Associations.
Performance of the Space Telescope Imaging Spectrograph after SM4 Charles R. Proffitt, A. Aloisi, K. A. Bostroem, C. R. Cox, R. I. Diaz, W. V. Dixon, P.
1-D Flat Fields for COS G130M and G160M Tom Ake TIPS 17 June 2010.
ACS/WFC CTE correction for point source photometry Marco Chiaberge ACS Team STScI.
UPDATED CTE CORRECTION FORMULAE FOR ACS Marco Chiaberge Pey Lian Lim, Vera Kozhurina-Platais, Marco Sirianni Ron Gilliland, Jennifer Mack.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA COS Pipeline PDR File Structure Overview Charles D. (Tony) Keyes 7 December 2000.
TIPS COS Status: SMOV update III STScI/CU COS Team 17 September 2009.
A Detector Upgrade for LDSS3 Mike Gladders Jacob Bean (on the phone) with Andreas Seifart, Josh Frieman, John Carlstrom.
TIPS - Oct 13, 2005 M. Sirianni Temperature change for ACS CCDs: initial study on scientific performance M. Sirianni, T. Wheeler, C.Cox, M. Mutchler, A.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA SMOV4 Requirements Review Cosmic Origins Spectrograph Scott D. Friedman STScI 30 July 2003.
MOS Data Reduction Michael Balogh University of Durham.
Practical applications: CCD spectroscopy Tracing path of 2-d spectrum across detector –Measuring position of spectrum on detector –Fitting a polynomial.
STIS Closeout Plan Paul Goudfrooij Space Telescope Users Committee, 11/18/2004.
Improving the Rectification of Spectral Images Linda Dressel, Paul Barrett, Paul Goudfrooij, and Phil Hodge.
NIC3 FOM Dithered Observations of the Orion Nebula Eddie Bergeron, STScI.
The Status of HST/COS and HST/STIS Cristina Oliveira 8/12/14COS and STIS Cal Workshop1 SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA.
PACS NHSC Data Processing Workshop Aug 26-30, 2013 Page 1 SPIRE Spectrometer Data: Calibration Updates, User Data Reprocessing, and Other Issues Nanyao.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA STIS Status Report Paul Goudfrooij Group News / Reorganization Unusual Target ACQ Failure Items.
HST Quarterly Review Page 1 Space Telescope Science Institute 15 October 2003 SI Status: COS STScI COS Program Activity SubprojectSTScI Activity Instrument.
STScI Slitless Spectroscopy Workshop November 2010 aXe Advanced Topics – becoming more dextrous, using aXe with other instruments, making calibration.
STIS Status TIPS July 16, STIS Status STIS MIE anomaly –What is known STIS CCD status before the anomaly STIS MAMA SMOV status.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA COS TAGFLASH System Requirements Review CALCOS Requirements Philip E Hodge 14 December 2005.
STIS STATUS Charles Proffitt TIPs May 21, STIS Status - Status of Repair Results of FT Amp B Bias Anomaly Changes to SMOV Plan.
STIS Status TIPS, September 17, 2009 Charles Proffitt for the STIS team.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA Cosmic Origins Spectrograph HST Quarterly Review – Instrument Status Charles D. (Tony) Keyes.
The HST/STIS Next Generation Spectral Library Michael Gregg, U.C. Davis/IGPP-LLNL David Silva, ESO (NOAO) John Rayner, IfA Guy Worthey, Washington State.
The STIS NUV-MAMA objective prism … … and looking beyond for HST UV slitless spectroscopy Jes ú s Ma í z Apell á niz HST Calibration worskhop 26 October.
In conclusion the intensity level of the CCD is linear up to the saturation limit, but there is a spilling of charges well before the saturation if.
Application of a Charge Transfer Model to Space Telescope Data Paul Bristow Dec’03
A. Ealet Berkeley, december Spectrograph calibration Determination of specifications Calibration strategy Note in
From the NGSL to Absolute Flux Sara Heap, NASA/Goddard Space Flight Center Don Lindler, Sigma Space Corporation Phase 1: NGSL observations + in situ calibration.
Single Object Spectroscopy and Time Series Observations with NIRSpec
Single Object Slitless Spectroscopy Simulations
NIRSpec Time Series Observations
JWST Pipeline Overview
Single Object & Time Series Spectroscopy with JWST NIRCam
Charge Transfer Efficiency of Charge Coupled Device
Institute of Cosmos Sciences - University of Barcelona
JWST NIRCam Time Series Observations
COS FUV Flat Fields and Signal-to-Noise Characteristics
C.Baltay and S. Perlmutter December 15, 2014
ESAC 2017 JWST Workshop JWST User Documentation Hands on experience
Summary Single Object & Time Series Spectroscopy Jeff Valenti JWST Mission Scientist Space Telescope Science Institute.
STIS Status Report Kailash C. Sahu Apr 18, 2002 TIPS.
Time-Dependent Spectral Traces for the STIS First Order Modes
MIRI Low Resolution Spectroscopy
Presentation transcript:

SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA TIPS: STIS Report Paul Goudfrooij 1.Unusual Target ACQ Failures: Update & Resolution 2.Calibration of CTE loss in Spectroscopic Modes Full story available under Also STIS ISR New “Pseudo-Apertures” (if time available)

TIPS Presentation Paul Goudfrooij 2 May 15, 2003 Recent Target ACQ Failures (with L. Dressel, R. Pitts, T. Wheeler) No Flux in the Lamp Image Two recent ACQs failed (March 2, April 6) due to No Flux in the Lamp Image All mechanisms show nominal telemetry ACQ macro used 3.8 mA setting for HITM1 lamp, much below ‘default’ 10 mA – 3.8 mA setting originally put in place to allow wavecals for the most sensitive MAMA settings, and to save lamp life time Contacted manufacturer + their consultant – Sputtered material forms a ring inside glass envelope around cathode. If set at (too) low current, electrons may flow to sputtered ring rather than to cathode Conclusion: Lamp did not fire Since 5/12/03, ACQs use 10 mA setting. All ACQs taken so far are OK.  

TIPS Presentation Paul Goudfrooij 3 May 15, 2003 Correcting CCD Spectroscopy for CTE Loss (with R. Bohlin) 4 Readout Amps (1 / corner) Bi-directional Clocking yields CTI  1 – CTE: CTI =  (flux D / flux B )  Y 1212 STIS CCD: Measured using “Sparse Field Tests” Serial overscan Axis1 (X) Axis2 (Y) Parallel (virtual) overscan Serial overscan Amp A Amp C Amp D Amp B Nominal Clocking Direction Nominal Readout Direction Sensitive Region (1024x1024 pix)

TIPS Presentation Paul Goudfrooij 4 May 15, 2003 “Sparse Field” Tests Sparse fields to ensure that sources do not overlap, in which case (e.g.) PSF wings could fill traps for sources along the readout direction Two varieties: (i) “Internal” Sparse Field Test – Annual series of lamp images through narrow slits, projected at 5 positions along columns (or rows) should be – Designed to represent “worst–case” point source spectroscopy (should be no background to fill traps)

TIPS Presentation Paul Goudfrooij 5 May 15, 2003 “Sparse Field” Tests (ii) “External” sparse field test (annually) – A. Imaging:  Sparse outer field in NGC 6752  CVZ target (‘cheap’ observing time; yields range of backgrounds)  3 exposure times; 50CCD mode – B. Spectroscopy:  Young open cluster NGC 346, in nebulosity  CVZ target  Slitless; 3 exp. times; G430L  [O II ] 3727, H , [O III ] 5007 lines in nebulosity provide three convenient, ~constant “sky” levels per spectrum

TIPS Presentation Paul Goudfrooij 6 May 15, 2003 CTI Parametrization: Imaging vs. Spectroscopy Dependence on signal & background levels to be done separately for imaging and spectroscopy Spectroscopy Imaging CCD Row Number CCD Column Number

TIPS Presentation Paul Goudfrooij 7 May 15, 2003 External Sparse Field Test: Imaging CTI Analysis Slope systematically flatter with increasing flux “Sky” presumably fills traps in bottoms of potential wells, mostly affecting transfer of small charge packets. Suggests CTI Clear dependence on background level (“sky”) bck signal   exp –

TIPS Presentation Paul Goudfrooij 8 May 15, 2003 The Strong Effect of Background: Gain=1 vs. Gain=4 Background level in spectroscopy mode typically low, dominated by dark current – Also need to account for spurious charge of the STIS CCD flush CCD Readout CCD

TIPS Presentation Paul Goudfrooij 9 May 15, 2003 Functional Dependence on Signal and Background Levels Iterative Process for Spectroscopy – Parameter space covered by ESF test at a given epoch is limited – Sensitivity monitor: good coverage of signal levels, but not of sky  G230LB data allow suitable cross-comparison with MAMA G230L AGK+81D266, G230LB

TIPS Presentation Paul Goudfrooij 10 May 15, 2003 Time Constant of CTI Evolution Need several datasets, each with same signal & background level Need datasets covering long baseline in time  ISF data – Have to correct for signal & background dependence prior to fitting CTI = CTI 0 + { [± 0.016] (t – t 0 ) } (with t in yr) CTI data points from Tom Brown 60 e –

TIPS Presentation Paul Goudfrooij 11 May 15, 2003 Final CTI Correction Formula (For Point-Source Spectroscopy) Define background (sky) and epoch parameters: yr = (MJD – ) / (i.e., relative to ) bg = max(BACKGROUND,0) for CCD Gain = for CCD Gain = 4 Functional form producing best fit to the data: CTI = GROSS –  exp –3.85  ( yr) bg GROSS 0.17 ) ( Implementation into the pipeline:  Formula parameters into CCD table reference file (new columns)  1-D extraction step ( x1d ) will correct for CTI by default for CCD data (CTE correction step switchable) For Cycle 12 Phase II, provided downloadable IRAF script to calculate correction factor for a given net & background level.

TIPS Presentation Paul Goudfrooij 12 May 15, 2003 Quality of CTI fit CTI Correction good to  7%  Spectrophotometry good to  1%

TIPS Presentation Paul Goudfrooij 13 May 15, 2003 New “Pseudo-Apertures” FUV-MAMA first-order spectroscopy at detector location with low dark – ~ 2’’ above bottom of detector – Reduction of dark current by factor of 5 – 52x0.05D1, …, F25QTZD1 Improvement of Fringe Flats at E1 positions – Important to align fringes in flat with those in target spectrum – 52x0.1 slit (best for defringing) location is offset in dispersion direction from wider slits – New ‘E2’ positions will place target slightly off- center in slits  0.2 arcsec wide New WEDGEA0.6 position for 50CORON Provide POS TARGs to GOs in Phase-II Update; Apertures to be implemented in next APT build. nominal new