BNL - FNAL - LBNL - SLAC LQ Test and Future Plans Giorgio Ambrosio, Guram Chlachidize Fermilab LARP Collaboration Meeting 13 Port Jefferson Nov. 4-6, 2009.

Slides:



Advertisements
Similar presentations
Protection study options for HQ01e-3 Tiina Salmi QXF meeting, 27 Nov 2012.
Advertisements

Spectrometer Solenoid Update Steve Virostek - LBNL MICE VC 150 August 23, 2012.
SC Magnets at Fermilab New Collaring and Coil Pre-stress Limit for a Nb3Sn Magnet Alexander Zlobin Technical Division Fermilab.
1 Preparation for MQXF Short Model Tests G. Chlachidze Fermilab.
ASC 2012, 10/10/2012Test results and analysis of LQS03 – G. Ambrosio 1 BNL - FNAL - LBNL - SLAC Test Results and Analysis of LQS03 Third Long Nb 3 Sn Quadrupole.
Test Result overview: Timeline, highlights and challenges H. Bajas TE-MSC-TF.
BNL - FNAL - LBNL - SLAC Long Quadrupole Results & Status Giorgio Ambrosio Fermilab Task Leaders: Fred Nobrega (FNAL) – Coils Jesse Schmalzle (BNL) – Coils.
Coil parts & Instrumentation issues for LQ/HQ coils tested at Fermilab HQ/LHQ coil parts task force.
2 nd Joint HiLumi LHC – LARP Annual Meeting INFN Frascati – November 14 th to 16 th 2012 Helene Felice Paolo Ferracin LQ Mechanical Behavior Overview and.
LQ Goals and Design Study Summary – G. Ambrosio 1 LARP Collab Mtg – SLAC, Oct , 2007 BNL - FNAL - LBNL - SLAC LQ Goals & Design Summary Giorgio Ambrosio.
LQS01 Test Preparation and Test Plan LARP Collaboration Meeting 12 LBNL - April 8-10, 2009.
HL-LHC/LARP, QXF Test Facility Workshop– R. Carcagno QXF Test Requirements Ruben Carcagno BNL Workshop December 17, 2013.
AARD Sub-panel at Fermilab Feb , 2006 LARP Magnet R&D Program - S. Gourlay1 BNL -FNAL - LBNL - SLAC LARP Magnet R&D Program Steve Gourlay AARD Sub-Panel.
LQ status and plans – G. Ambrosio 1 LARP Collaboration Meeting - LBNL, April , 2006 BNL - FNAL - LBNL - SLAC OUTLINE: Goals, Input and Output Sub-tasks.
Brookhaven - fermilab - berkeley US LHC ACCELERATOR PROJECT LHC IR Quad Heaters.
11 T Nb3Sn Demonstrator Dipole R&D Strategy and Status
BNL - FNAL - LBNL - SLAC Design and Test of the 1 st Nb 3 Sn Long Quadrupole by LARP Giorgio Ambrosio Fermilab Acknowledgement: many people contributed.
LARP CM15 Magnet Testing Working Group SLAC, November 2 nd 2010.
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
Superconducting IR Magnets CHEN, Fusan May 11, 2007.
Lab Coordination Meeting 3/21/13LHC IR Quadrupole Plan – G. Sabbi 1 LARP Magnet Systems Plan GianLuca Sabbi Lab Coordination Meeting March 21, 2013.
BNL - FNAL - LBNL - SLAC Progress Report on LQ Program Giorgio Ambrosio Fermilab Task Leaders: Fred Nobrega (FNAL) – Coils Jesse Schmalzle (BNL) – Coils.
HL-LHC Annual Meeting, November 2013HQ Planning – G. Sabbi 1 HQ Status and Plans G. Sabbi High Luminosity LHC Annual Meeting Daresbury, UK, November 11-14,
S. Caspi, LBNL HQ Progress and Schedule Shlomo Caspi LBNL LARP Collaboration Meeting – CM13 Port Jefferson November 4-6, 2009.
LQ Quench Protection – G. Ambrosio 1 LQ DS video Mtg – May. 23, 2007 BNL - FNAL - LBNL - SLAC Long Quadrupole Quench Protection Giorgio Ambrosio LQ DS.
MQXF support structure An extension of LARP experience Helene Felice MQXF Design Review December 10 th to 12 th, 2014 CERN.
HQ01e3 test summary December 2012 M. Marchevsky, LBNL.
LARP Magnets FNAL contribution to LARP (LHC Accelerator Research Program) FNAL core-program support to LARP DOE Annual Program Review - May 16-18, 2006.
LARP Magnet Progress Michael Lamm For the LARP Collaboration bnl - fnal - lbnl - slac US LHC Accelerator Research Program All Experimenters’ Meeting Monday,
Subscale quadrupole (SQ) series Paolo Ferracin LARP DoE Review FNAL June 12-14, 2006.
Test Program and Results Guram Chlachidze for FNAL-CERN Collaboration September 26-27, 2012 Outline Test program Quench Performance Quench Protection Magnetic.
Long Quadrupole – G. Ambrosio 1 LARP Collaboration Meeting – FNAL, Oct , 2008 BNL - FNAL - LBNL - SLAC Long Quadrupole Giorgio Ambrosio LARP Collaboration.
Helene Felice HQ Test Results Review Thursday December 16 th Overview of HQ coils and Magnet.
HQM01 Test Summary Outline -Magnet Instrumentation and Shim System -SG Data -Short Sample Limits -Quench Training at 4.6 K and 2.2 K -Ramp rate and Temperature.
Cold powering test results of MBHSP102 Gerard Willering, TE-MSC-TF With thanks to Jerome and Vincent and all others from TF for their contribution.
S. Caspi, LBNL TQS – Progress and plans Shlomo Caspi LBNL Collaboration meeting FNAL April
1 BNL -FNAL - LBNL - SLAC P. Wanderer IR’07 - Frascati 7 November 2007 U.S. LARP Magnet Programme.
1 MQXF(S) Magnet Interface Document MQXF(S) magnet interface document will describe electrical connection between the magnet and the header assembly Scope.
Long Quad (LQ) & High Gradient (HQ) Series Alexander Zlobin bnl - fnal- lbnl - slac US LHC Accelerator Research Program DOE LARP review Fermilab, June.
Sept. 29, 2008Rodger Bossert1 Quench Positions in TQC Models Rodger Bossert Technical Division Technical Memo #TD September 29, 2008.
HQ02A2 TEST RESULTS November 7, 2013 FERMILAB. HQ02 test at Fermilab 2  First HQ quadrupole with coils (#15-17, #20) of the optimized design o Only coil.
BNL - FNAL - LBNL - SLAC Long Quadrupole Giorgio Ambrosio Fermilab Long Quadrupole Task Leaders: Fred Nobrega (FNAL) – Coils Jesse Schmalzle (BNL) – Coils.
LARP DOE Review, 7/9/2012Long Quadrupole – G. Ambrosio 1 Long Quadrupole Program Giorgio Ambrosio DOE Review of the LARP Program SLAC July 9-10, 2011 LQ.
BNL - FNAL - LBNL - SLAC Long Quadrupole Giorgio Ambrosio Fermilab Many people contributed to this work, most of all the Long Quadrupole Task Leaders:
MQXFS1 Test Results G. Chlachidze, J. DiMarco, S. Izquierdo-Bermudez, E. Ravaioli, S. Stoynev, T. Strauss et al. Joint LARP CM26/Hi-Lumi Meeting SLAC May.
Answers to the review committee G. Ambrosio, B.Bordini, P. Ferracin MQXF Conductor Review November 5-6, 2014 CERN.
LQM01 Test Summary Guram Chlachidze LARP CM16 Montauk, NY May 16-18, 2011.
MQXFSM1 results Guram Chlachidze Stoyan Stoynev 10 June 2015LARP meeting.
2 nd LARP / HiLumi Collaboration Mtg, May 9, 2012LHQ Goals and Status – G. Ambrosio 11 Quench Protection of Long Nb 3 Sn Quads Giorgio Ambrosio Fermilab.
LARP CM15, SLAC, 11/3/2010GianLuca SabbiSummary of MS Parallel Sessions Summary of Magnet Systems Parallel Sessions GianLuca Sabbi LARP Collaboration Meeting.
2 nd LARP / HiLumi Collaboration Mtg, May 9, 2012LHQ Goals and Status – G. Ambrosio 11 LHQ Goals and Status Giorgio Ambrosio Fermilab 2 nd LARP / HiLumi.
LQS01a Test Results LARP Collaboration Meeting 14 Fermilab - April 26-28, 2010 Guram Chlachidze.
HQ02 TEST STATUS April 4, 2013 FERMILAB. Test status  Magnet delivery to FermilabApr. 02  SG checkoutApr. 04  LE & RE interface plate mounting Apr.
Superconducting Cryogen Free Splittable Quadrupole for Linear Accelerators Progress Report V. Kashikhin for the FNAL Superconducting Magnet Team (presented.
MICE CC TEST, IN PROGRESS M. Tartaglia For the FNAL/LBNL Test Team 9/27/13.
DOE Review, 6/2/2011Answers to Committee Questions – Magnet Systems Answers to committee questions - magnets.
LQ Test Results and Next Steps 1 st HiLumi LHC/LARP Collaboration Meeting CERN, November 2011 Guram Chlachidze.
Jim Kerby Fermilab With many thanks to Vladimir Kashikhin, the FNAL, KEK, and Toshiba teams. SCRF BTR Split Quadrupole ILC ML & SCRF Baseline Technical.
S. Feher MICE Magnet Readiness Review RAL, June 28th, 2016
11T Magnet Test Plan Guram Chlachidze
Model magnet test results at FNAL
MQXF Goals & Plans G. Ambrosio MQXF Conductor Review
HO Corrector Magnets: decapole test and future plans
MBHSP02 test STATUS and first results
Quench Protection Measurements & Analysis
Guram Chlachidze Stoyan Stoynev
MQXFS1e – PH-to-Coil hipot tests
Long term behavior of MQXFS1
Long term behavior and high MIITs test in the LARP program
Hi-pot results summary
Presentation transcript:

BNL - FNAL - LBNL - SLAC LQ Test and Future Plans Giorgio Ambrosio, Guram Chlachidize Fermilab LARP Collaboration Meeting 13 Port Jefferson Nov. 4-6, 2009

G. Ambrosio - Long Quadrupole 2 Long Quadrupole Main Features: Aperture: 90 mm magnet length: 3.7 m Target: Gradient: 200+ T/m Goal: Demonstrate Nb 3 Sn magnet scale up: –Long shell-type coils –Long shell-based structure (bladder & keys) 1 st Long Quad test by the end of nd Long Quad test in Spring 2010 LQ Design Report available online at: LQS01 SSL4.3 K Current13.9 kA Gradient242 T/m Peak Field12.4 T Stored Energy473 kJ/m

G. Ambrosio - Long Quadrupole LARP CM13 – BNL – Nov. 4-6, 2009 Test Preparation Quench Detection System with Adaptive Thresholds –To allow using low threshold at high current avoiding trips due to voltage spikes at low current –Both DQD and AQD Symmetric Coil Grounding –To reduce peak coil-ground voltage LQ needs larger dump resistance than TQ magnets (60 vs 30 mOhm) Reconfiguration of the Magnet Protection System –Additional Heater-Firing-Units for all LQ heaters (16) Modified Strain Gauge Readout System –To reduce noise and sampling time  All new systems tested all together two weeks ago  Upgrades passed LQS01 Test Readiness Review J in copper = 2900 A/mm 2 at 13.9 kA (4.3 K SSL)

LQS01 Status LQS01 is connected to the VMTF top-head Electrical check-out is in progress Cool down start: this weekend or early next week LARP CM13 – BNL – Nov. 4-6, 2009

Test GOALS - I Achieve target gradient 200 T/m –Understand limiting coil/section  Cause? (repairs, stress, …) –Compare gradient at 4.5K plateau with target –Compare gradient at 4.5K plateau with TQS02-series Understand training –Are training quenches concentrated in a coil/section?  Coil design, fabrication; magnet pre-stress, assembly… –Compare training at 4.5K with TQS02a Understand if changing one coil could improve “significantly” performance –By looking at plateau q. + training q. + Ramp-Rate study LARP CM13 – BNL – Nov. 4-6, 2009 G. Ambrosio - Long Quadrupole

Test GOALS - II Understand if limitation is due to mechanics and/or coils –By temperature dependence study 3K should be enough, and may be even better based on TQS02a/c Memory after thermal cycle –Warm up, cool down and retraining at 4.5K Understand behavior at 1.9K –Erratic or plateau quenches? Max quench current? –Compare with TQS02 series –Effects of bubbles on IL quench heater insulation? Could cause coil-heater shorts! Could reduce the number of usable protection heaters LARP CM13 – BNL – Nov. 4-6, 2009 G. Ambrosio - Long Quadrupole

1.9K Test “Bubbles” are a possible cause for coil-heater shorts  Electric arc? Note: we never had heaters on inner layer

LQS01 Test Plan - I Room temperature preparation and cool down (10 days) Magnetic measurements (z-scan) at VMTF 1st Thermal Cycle (10 days) Test at 4.5 K Cold electrical checkout Magnetic measurements Quench training Ramp rate study Cool down to 3 K Quench Training Magnetic measurements Ramp rate study Temperature dependence study Warm up to 4.5 K Verify quench plateau at 4.5 K G. Ambrosio - Long Quadrupole

LQS01 Test Plan - II Warm up to 300 K (4 days) RRR measurements Cool down (4 days) 2nd Cold Test (10 days) Test at 4.5 K Quench training  Memory Cool down to 1.9 K Verify operation of protection heaters –To avoid possible damage after first few quenches we will do hi-pot (coil- heaters) and low current trips to verify proper operation of heaters Quench Training Magnetic measurements Ramp rate study Temperature dependence study G. Ambrosio - Long Quadrupole LARP CM13 – BNL – Nov. 4-6, 2009

LQS01 Test Plan - III Warm up to 4.5 K Verify quench plateau Protection heater study Spot heater study Warm up to room temperature (6 days) Magnetic measurements (z-scan, use warm-finger of full length) LARP CM13 – BNL – Nov. 4-6, 2009 G. Ambrosio - Long Quadrupole

Present LQ FY10 plan Notes: –Coils #14 & #15 start after LQS01 feedback –Coil #13 may have delays because of conflict with HQ coils fabrication Plan for success with budget = $1.4 M –Need contingency money in case of “problems” LARP CM13 – BNL – Nov. 4-6, 2009 G. Ambrosio - Long Quadrupole

LQS01 Test Scenarios 1.Successful (G >= 200 T/m) 2.Limited (G < 200 T/m) by one or two coils 3.There is a flaw in all LQ coils design and/or fabrication technology 4.All coils are damaged during cooldown or test mechanics or quench protection failure, excessive pre-load, … G. Ambrosio – Long Quadrupole 13  LQS02 (4 new coils) or LQS01b (1 or 2 new coils)  LQS01b (1 or 2 new coils), may need 3 rd test Need analysis to understand cause of limitation May need 4 new coils (2 out of contingency) Need LQS02 and 3 rd test LARP CM13 – BNL – Nov. 4-6, 2009

G. Ambrosio - Long Quadrupole LARP CM13 – BNL – Nov. 4-6, 2009 Conclusions The test of the first Nb 3 Sn Long Quadrupole (LQS01) is starting We planned the test in order to obtain as much information as possible The present LQ FY10 plan is based on success –May need to use contingency in case of limited performance

Addendum

G. Ambrosio - Long Quadrupole Appendix

Test Preparation: Subsystem upgrades Symmetric coil grounding Strain Gauge Readout System Reconfiguration of the Magnet Protection System Quench Detection System with Adaptive Thresholds

Symmetric Coil Grounding The VMTF power system bus is grounded at one point to constrain voltage to ground and to detect electrical fault to ground of the coil Old grounding was asymmetric - power system was grounded at the negative current bus via a 25 Ohm current limiting resistor Started this summer symmetric coil grounding was implemented with 100 Ohm current limiting resistor Peak coil to ground voltage for LQS01 test is reduced from ~900 V to ~450 V for 60 mΩ dump resistor PS Magnet 25 Ω 100 Ω

Symmetric Coil Grounding Maximum ground current through the fault also is reduced from ~40 A to ~ 6 A Now equally sensitive to ground faults at positive or negative leads We have more predictable voltage and current profiles after the quench Symmetric coil grounding was tested for TQC02a, TQC02b and TQM02 magnets, permanently implemented in May 2009 Special test performed with a 30 kA top plate to check symmetric grounding at higher currents (up to ~ 28.5 kA) Passed safety and technical reviews at FNAL

Test Preparation Symmetric coil grounding Strain Gauge Readout System Reconfiguration of the Magnet Protection System Quench Detection System with Adaptive Thresholds

LQSD test showed that FNAL SG system at the beginning had a much worse resolution wrt the LBL portable system All SG in LQS are connected into a full-bridge circuit: one half-bridge used for the active gauges and the other for the T-compensator gauges Dealing with very low voltage signals: FNAL SG system was able to provide max. 1.2 mA current against 5.0 mA in the LBL system Strain Gauge System

Minor modifications improved FNAL SG system resolution: One single SG slow scan replaced with 2 scans running in parallel - the maximum current increased to 1.5 A, at the same time scan period reduced Voltage range in DMM HP-3458A was reduced from 10 V to 1 V - resolution increased which is important when reading very low voltage signals Number of integration cycles in DMM increased Strain Gauge System

Strain Gauge System improvements Now running 4 SG scans in parallel - each equipped with an individual 8.5 digit DMM HP-3458A. We can read 64 SG in total. All DMM were recently calibrated New 4-channel current source was built for the SG system Magnet current signals from the Holec transductor are divided to allow the same 1 V readout range in DMM for both the SG and current signals Up to 2 mA is provided to each SG scan

Strain Gauge System improvements Sampling rate is increased. Scan period is ~ 2-3 s for the SG slow scans and ~ 5 s for the RTD slow scan, which combined gives ~ 6-7 s of time period for the fast scan scribe Modified SG system tested for TQM03 mirror magnet LQS01 SG readout will be performed using both LBL and FNAL systems: LBL system is used for measurements before and after the cold test, when magnet is in a horizontal or vertical position FNAL system will be used for measurements during the cold test Need consistent readings from these 2 systems

Reference bridge was built at Fermilab to verify if FNAL and LBL readings are consistent Vishay 350-Ohm precision resistors used Platinum RTD installed for follow temperature change Bridge first measured using a calibrated system Reference bridge already used for LQSD: good agreement found between the LBL and FNAL systems Strain Gauge System improvements

Test Preparation Symmetric coil grounding Strain Gauge Readout System Reconfiguration of the Magnet Protection System Quench Detection System with Adaptive Thresholds

Each coil of LQS01 magnet is equipped with 4 protection heaters and 1 spot heater Protection heaters are on both the outer and inner coil layers All heaters of the same coil layer and side (LE or RE) will be connected in parallel Magnet Protection System

Heaters on the outer layer RE for both coil 7 and 9 will not be connected Coils 7 and 9 are placed against each other in magnet Dummy loads will be connected or different capacitance will be set for HFU with less number of heaters Coil 7 heater on the outer layer LE will be connected only if cold hipot is successful Polarity of heaters on outer and inner layers will be opposite LE and RE heaters will be powered with opposite polarity Magnet Protection System + _ _ + coil 8 coil 7 coil 9 coil 6 Lead End View

New heater design, application to inner coil surface, operation at a high voltages and currents ( V, ~250 A) suggested to test heater and HFU performance LQ practice coil #5 heaters were tested at a liquid nitrogen temperature at Fermilab HFUs successfully survived currents above 250 A (up to 450 V) at a capacitance of 19.2 mF and time constant ~ 30 ms No difference was observed in performance of the heaters on the inner and outer coils. Magnet Protection System IB3 - Fermilab/TD

Existed magnet protection system was modified to accommodate large number of heaters in LQS01 Re-designed magnet protection system includes 4 heater firing units (HFU) for protection heaters and 2 HFUs for spot heaters Heater distribution box was re-designed to accommodate up to 8 strip heaters in total We need only 4 for LQS01 Magnet Protection System Summing module

Summing module was designed to switch the magnet protection system from operation with 4 HFUs to operation with 2 HFUs. Usually 2 HFUs are used when testing magnets with a smaller number of heaters Summing module consists of 3 channels: 2 for protection heaters and one for spot heaters. Each channel operates a pair of HFUs All logic signals for QLM are obtained by adding the corresponding signals from both HFUs in each pair Two HFUs in each pair also should have same bank capacitances Magnet Protection System

Currently all elements of re-designed magnet protection system are in place, spare HFUs are available New system was tested with dummy loads for both 4-HFU and 2-HFU operation. Operational logic for different failure modes also was tested Final test will be done for TQM03 magnet Magnet Protection System

Test Preparation Symmetric coil grounding Strain Gauge Readout System Reconfiguration of the Magnet Protection System Quench Detection System with Adaptive Thresholds

Goal is to apply current dependent quench detection thresholds for half-coil signals High threshold at low currents and low threshold at high currents will help to avoid low current trips due to voltage spikes observed in Nb 3 Sn magnets and keep MIITs low during quench training Adaptive thresholds will be set by FPGA based quench management (QM) system successfully used to test HINS solenoids at FNAL FPGA code developed to set thresholds for 10 different current ranges. Threshold at 0 current will apply if current reading fails

Currently FPGA system works in addition to the VME QLM FPGA signal is connected to VME AQD coils in “OR” mode PXI data Loggers are triggered back from the VME system FPGA system sends signal to the VME “change of status” module In future both VME and FPGA systems will work in parallel, and FPGA QLM will be fully functional Quench Detection System with Adaptive Thresholds

VME module for AQD half-coils also was modified to set a current dependent threshold. This module was tested for TQM02 magnet Most elements of the FPGA based QM system were tested for TQM03 magnet Final checkout with all FPGA components will be done in next 2 weeks for TQM03 magnet

Data analysis and storing Quench data analysis will be done at Fermlab Test summary will be released as a TD note SG data collected with the LBL system temporarily are placed at a public area: SG data from FNAL system will be processed on-line to get strains All necessary scripts are in place Cron-jobs will run to upload voltage and strain data to the data storage area hourly WebDat - new database for storing test data at Fermilab MTF Password protected area: FNAL SG data will be saved in WebDat area SG data from the LBL system also will be moved to WebDat

Cool Down Temperature gradient along the magnet to be limited during the cool down For LQSD the initial 50 K constraint on temperature gradient resulted in very slow cool down: after 15 hrs magnet top still was at ~300 K Estimated cool down time for ΔT=150 K is 48 hrs. Since cryo-operator is involved cool down will take ~ 4 calendar days LQS01 warm up also should take ~ 4 days to reach 300 K LQSD was warmed up with GN 2 in ~ 6 days LQSD cool down ΔT=150 KΔT=50 K Magnet top Magnet bottom