The calibration and alignment of the LHCb RICH system Antonis Papanestis STFC - RAL for the LHCb Collaboration.

Slides:



Advertisements
Similar presentations
HARP Anselmo Cervera Villanueva University of Geneva (Switzerland) K2K Neutrino CH Meeting Neuchâtel, June 21-22, 2004.
Advertisements

USE OF GEANT4 FOR LHCB RICH SIMULATION S. Easo, RAL, LHCB AND ITS RICH DETECTORS. TESTBEAM DATA FOR LHCB-RICH. OVERVIEW OF GEANT4 SIMULATION.
Cherenkov Detectors. Index of Refraction When light passes through matter its velocity decreases. –Index of refraction n. The index depends on the medium.
14 Sept 2004 D.Dedovich Tau041 Measurement of Tau hadronic branching ratios in DELPHI experiment at LEP Dima Dedovich (Dubna) DELPHI Collaboration E.Phys.J.
27 th June 2008Johannes Albrecht, BEACH 2008 Johannes Albrecht Physikalisches Institut Universität Heidelberg on behalf of the LHCb Collaboration The LHCb.
Assisi – 23 June 2005 Tito Bellunato 1 Status of the LHCb RICH detector and the HPD Beauty 2005 Assisi – 23 June 2005 Tito Bellunato – Università degli.
30 March Global Mice Particle Identification Steve Kahn 30 March 2004 Mice Collaboration Meeting.
Study of two pion channel from photoproduction on the deuteron Lewis Graham Proposal Phys 745 Class May 6, 2009.
Beauty 2006 R. Muresan – Charm 1 Charm LHCb Raluca Mureşan Oxford University On behalf of LHCb collaboration.
Zhihong Ye Hampton University Feb. 16 th 2010, APS Meeting, Washington DC Data Analysis Strategy to Obtain High Precision Missing Mass Spectra For E
The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511 Shibata Lab 11R50047 Jennifer Newsham YSEP.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
Leroy Nicolas, HESS Calibration results, 28 th ICRC Tsukuba Japan, August Calibration results of the first two H·E·S·S· telescopes Nicolas Leroy.
Overview of LHCb RICH Detector Development On Behalf of LHCb-RICH Group RICH2004 Playa Del Carmen, Mexico December 4, 2004 S. Easo Rutherford-Appleton.
A Reconstruction Algorithm for a RICH detector for CLAS12 Ahmed El Alaoui RICH Workchop, Jefferson Lab, newport News, VA November th 2011.
Physics Performance of LHC-B Neville Harnew University of Oxford Beauty-97, Los Angeles October Outline Introduction The LHC-B Experiment New.
RICH detectors for LHCb Tito Bellunato INFN Milano-Bicocca On behalf of the LHCb RICH collaboration 10th International Conference on Instrumentation for.
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
Åsmund Skjæveland Magnetic Distortion of HPD Images.
HPD Performance in the RICH Detectors of the LHCb Young Min Kim University of Edinburgh IoP HEPP Conference – April
Development of the RICH Detectors in LHCb S. Easo Rutherford-Appleton Laboratory June 5, 2002 RICH2002 PYLOS, GREECE For the LHCb-RICH Group.
Ronald Bruijn – 10 th APP Symposium Antares results and status Ronald Bruijn.
RICH SIMULATION USING GEANT4 S.EASO, RAL OBJECTIVES OF THE SIMULATION. CURRENT STATUS AND PLANS. INTEGRATION WITH LHCb SOFTWARE. SUMMARY.
Performance of the LHCb RICH detectors On behalf of the LHCb-RICH Collaboration Sajan Easo Rutherford-Appleton Laboratory IEEE-NSS: Dresden, Germany,
E. De LuciaNeutral and Charged Kaon Meeting – 7 May 2007 Updates on BR(K +  π + π 0 ) E. De Lucia.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
An overview of the LHCb RICH detectors RICH 2007 Trieste Oct 2007 Neville Harnew University of Oxford On behalf of the LHCb RICH Collaboration.
1 Lead glass simulations Eliane Epple, TU Munich Kirill Lapidus, INR Moscow Collaboration Meeting XXI March 2010 GSI.
Detection of electromagnetic showers along muon tracks Salvatore Mangano (IFIC)
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
The Ring Imaging Cherenkov Detectors of the LHCb Experiment
Status Report particle identification with the RICH detector Claudia Höhne - GSI Darmstadt, Germany general overview focus on ring radius/ Cherenkov angle.
The RICH Detectors of the LHCb Experiment Carmelo D’Ambrosio (CERN) on behalf of the LHCb RICH Collaboration LHCb RICH1 and RICH2 The photon detector:
Status of the hadronic cross section (small angle) Federico Nguyen February 22 nd 2005  the 2002 data sample and available MC sets  trigger efficiency.
RICH Simulation in LHCb LHC Detector Simulation Workshop S.Easo, RAL, On behalf of LHCb–RICH group.
Particle Identification with the LHCb Experiment
 0 life time analysis updates, preliminary results from Primex experiment 08/13/2007 I.Larin, Hall-B meeting.
Tests of a proximity focusing RICH with aerogel as radiator and flat panel PMT (Hamamatsu H8500) as photon detector Rok Pestotnik Jožef Stefan Institute,
1 Limitations in the use of RICH counters to detect tau-neutrino appearance Tord Ekelöf /Uppsala University Roger Forty /CERN Christian Hansen This talk.
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
Paolo Massarotti Kaon meeting March 2007  ±  X    X  Time measurement use neutral vertex only in order to obtain a completely independent.
The RICH detectors of LHCb and the proposed upgrade Antonis Papanestis On behalf of the LHCb RICH collaboration 1.
23/02/07G. Vidal-Sitjes, VCI2007 Vienna Conference on Instrumentation1 The LHCb RICH detector G. Vidal-Sitjes on behalf of the LHCb RICH team Outline:
Alignment Challenge at LHCb Steven Blusk Syracuse University LHC Alignment Workshop, Aug 3-5, 2006.
RICH studies for CLAS12 L. Pappalardo1 Contalbrigo Marco Luciano Pappalardo INFN Ferrara CLAS12 RICH Meeting – JLab 21/6/2011.
LHCb Alignment Strategy 26 th September 2007 S. Viret 1. Introduction 2. The alignment challenge 3. Conclusions.
Open and Hidden Beauty Production in 920 GeV p-N interactions Presented by Mauro Villa for the Hera-B collaboration 2002/3 data taking:
The Ring Imaging Cherenkov Detectors for LHCb Antonis Papanestis CCLRC – RAL On behalf of the LHCb RICH group.
The magnetic calibration procedure is performed in dedicated LED scans with dipole field ON and OFF. Scans with field OFF are used to reconstruct the calibration.
Development of Forward Aerogel Cherenkov Detector for the H-dibaryon search experiment (E42) at J-PARC Japan-Korea PHENIX Collaboration Meeting Minho Kim.
Susanna Costanza - Pavia Group PANDA C.M., Stockholm – June 14, 2010
Status of GEANT4 in LHCb S. Easo, RAL, The LHCb experiment.
Particle Identification in LHCb
The Pixel Hybrid Photon Detectors of the LHCb RICH
TORCH – a Cherenkov based Time-of-Flight Detector
Multianode Photo Multipliers for Ring Imaging Cherenkov Detectors
RICH 2004 Characterization and compensation of magnetic distortions for the pixel Hybrid Photon Detectors of the LHCb RICH Gianluca Aglieri Rinella,
LHCb Particle Identification and Performance
Bs  μ+μ- in LHCb Diego Martínez Santos
T. Bowcock University of Liverpool For the LHCb Collaboration
Particle Identification with the LHCb Experiment
B Physics at the LHC Neville Harnew University of Oxford.
LHCb Alignment Strategy
Contents First section: pion and proton misidentification probabilities as Loose or Tight Muons. Measurements using Jet-triggered data (from run).
How can we study the magnetic distortion effect?
RICH 2004 Characterisation and compensation of magnetic distortions for the pixel Hybrid Photon Detectors of the LHCb RICH Gianluca Aglieri Rinella,
Reconstruction and calibration strategies for the LHCb RICH detector
Presentation transcript:

The calibration and alignment of the LHCb RICH system Antonis Papanestis STFC - RAL for the LHCb Collaboration

RICH / 21 Outline  Quick overview of the LHCb RICH system.  Calibration & Alignment with projected test patterns:  Magnetic field corrections.  HPD Quantum efficiency monitoring.  Alignment without tracks.  Calibration & Alignment with tracks (data):  Alignment with tracks.  Refractive index.  Cherenkov angle resolution.  Particle ID calibration.

RICH / 21 The LHCb Detector A forward single arm spectrometer RICH1 RICH2 VELO Magnet Tracker Calorimeter Muon

RICH / 21 RICH detector facts  Full acceptance (300 mrad horizontal, 250 mrad vertical) coverage.  Two radiators:  Aerogel, 540 nm.  C 4 F 400 nm.  4 composite spherical mirrors.  16 glass flat mirrors.  196 HPDs.  Acceptance 120 mrad horizontal and 100 mrad vertical.  CF 4 radiator:  400 nm.  56 glass spherical mirrors.  40 glass flat mirrors.  288 HPDs. Two mirror (spherical and flat) system. HPDs for photon detectors. Magnetic shielding. Gas radiators at atmospheric pressure. RICH1 & RICH2 RICH1RICH2 HPD array

RICH / 21 RICH system HPD plane: 7 columns, 14 tubes each Magnetic shield box Vertical X-section Spherical Mirror Flat Mirror Photon funnel+Shielding Central Tube Mirror Support Panel Z Y X RICH1 RICH2

RICH / 21 Calibration with projected patterns  HPDs operate in the fringe field of the LHCb magnet.  Magnetic shielding is used to minimise the magnetic field, however, image distortions are still possible.  Test pattern will be projected on detector planes with magnet off and on to test for distortions and obtain calibration parameters.  RICH2 will use an off the self projector. RICH1 will scan an array of LEDs in front of the HPDs.  There are 3 PMTs in each HPD panel in RICH2 to locate the pattern. HPD schematic and picture (G. Aglieri Rinella et al., NIMA 553 (2005) 120)

RICH / 21 Test pattern projection Finding clusters in the presence of non-uniform background. Highly attenuated light (2-3 hits/HPD/25 ns) Results from test setup with 1 HPD column. HPD 629 HPD 684

RICH / 21 Center of Gravity Analysis Immagine con fit lineari Rotated figure to fit vertical lines Horizontal lines Use the same technique for HPD to HPD alignment. Can extract mirror orientation parameters in RICH2 by projecting the pattern via the mirrors.

RICH / 21 HPD QE monitor (with LED projector in RICH2) PMT signal vs lightHPD photon count vs light Use LED projector and PMTs to monitor HPD quantum efficiency Light emitted (a.u.) Blue LED light Green LED light Amount of light varied using neutral density filters 3 different HPDs Green LED light

RICH / 21 Alignment with tracks Mirror misalignment histograms RICH misalignment Cherenkov ring

RICH / 21 Mirror alignment  Emission point of photons is not known.  Cannot correct mirror misalignment for photons that cannot identify the mirrors they were reflected on.  Mirror segments must form a uniform mirror. 2 mm Mirror movement during transport and installation Initial mirror alignment (50 rad)

RICH / 21 Test-beam Alignment (1)  C 4 F 10 runs with rings that cover multiple HPDs.  Preliminary investigations into two runs:  Run 27 (ring on 3 HPDs).  Run 28 (ring on 4 HPDs).  Two effects to distinguish:  Global misalignment caused by mirror position.  Effects of misalignment of individual HPDs. HPD 283 HPD 265 HPD 282 HPD 222 Run 27 at Mirror Position 29 Run 28 at Mirror Position 30

RICH / 21 Test-beam alignment (2) After 1 st mirror alignment After mirror alignment and alignment of Si sensors according to data from the test centres HPD 283 HPD 265HPD 222 HPD 283 HPD 222 HPD 265 HPD 282

RICH / 21 T/B 2 nd Mirror Alignment Sigma similar to N 2 test-beam runs on single HPD (work in progress) Cherenkov theta (rad)

RICH / 21 Cherenkov angle (RICH2, “Forward” tracks > 80 GeV) Cherenkov angle resolution using MC info for photon-track association and particle type No Monte-Carlo information. Peak mean value gives refractive index Sigma gives Ch angle resolution Correct photon-track association Wrong photon-track association Sigma 0.64 mradSigma 0.80 mrad

RICH / 21 RICH1 Cherenkov angle ( “Forward” tracks > 80 GeV )  Hardware monitoring for gas radiators:  Gas temperature (5 sensors in RICH1, 20 in RICH2, 0.2°C).  Pressure relative to atmospheric (0.1 mbar).  Speed of sound technique for gas purity (1%). Ch angle resolution (rad) Reconstructed Ch angle (rad) Sigma 1.4 mradSigma 2.3 mrad

RICH / 21 RICH particle ID calibration (with particle samples selected independently of the RICH) “Golden” kinematics easy to suppress the background in order to obtain a clean sample: Mass difference (M D* - M D0 )=145.4 MeV A dedicated D* trigger will provide about 10 7 D*+  D 0  +, D 0  K events per year. A kaon and two pions with different momenta from each event can be used for RICH calibration. A method to calibrate and study the performance of the RICH detector completely independent of the MC truth information using the D *+  D 0  +, D 0  K  decay chain (D*-D 0 ) mass (GeV)

RICH / 21 D* event selection cuts D0D0 p , K (GeV) p t , K (GeV) IP sig. , K   D 0 vertex D 0 mass (GeV) p t D 0 (GeV) >2 >0.3 >3 <16 (1.84,1.89) D*D* IP sig. slow  Dist PV - D0 DVsig.   D * vertex p t D * (GeV) D * mass (GeV) mass ( D*- D 0 ) (GeV) >1. >6 < (1.990, 2.030) (0.1445, ) SELECTION WITH KINEMATIC CUTS ONLY – NO RICH. Particles are attributed in turn K mass and  mass B d →D*X sample ; The cuts provide a very clean k and  sample (about 90% purity). Purity can be improved with reduced efficiency. Over 90% D 0 selected are true D 0

RICH / 21 Kaons and pions identified using MC truth Kaons and pions from the MC independent calibration sample Biases introduced by the method are negligible if the efficiency and the misidentification rates are considered both as a function of p and p t.  →K, p K→K, p  e   e  Comparison with MC truth

RICH / 21 Kaons (p t >1 Gev) and pions (p t >1 GeV) identified using MC truth kaons and pions from the MC independent calibration sample (p t >1GeV), with slow pion p t >1 GeV DC06 sample; recent developments show significant improvement in overall RICH pID. K→K, p  →K, p  e   e  With P t cuts

RICH / 21 Conclusions  The LHCb RICH system requires a number of calibration parameters to reach its full potential.  Alignment, refractive index, Cherenkov angle resolution.  These parameters can be extracted from data and the algorithms required have been implemented and tested.  Hardware monitoring will assist and confirm the calibration.  It is possible to evaluate the particle ID performance of the RICH system using particles of known type selected independently of the RICH.  An alignment challenge is expected in early 2008, where simulation data will be produced with the whole LHCb detector misaligned.