Lighting Lab Online Presented By: Omar Yehia Omar Elshrief By: Konstantinos Papamichael Web Address:

Slides:



Advertisements
Similar presentations
ADAPT A ssessment & D esign for A daptation: a P rototype T ool Ian Noble, World Bank & Fareeha Y. Iqbal (Consultant, World Bank)
Advertisements

Sustainable Lighting Strategies
Irwin/McGraw-Hill Copyright © 2000 The McGraw-Hill Companies. All Rights reserved Whitten Bentley DittmanSYSTEMS ANALYSIS AND DESIGN METHODS5th Edition.
DOE-2 Overview and Basic Concepts. Background  US public domain programs from 1970s Post Office program; NECAP (NASA energy- cost analysis program);
Multispectral Format from Perspective of Remote Sensing
Step Up Payback Proposal Program “How-To” 9/4/07.
Energy Tax Savers, Inc. Tax Aspects of Daylighting and Solar Shades Presentation.
Designing Projection Systems
Habitat For Humanity. HFH Members â Architectural Team ã Bill Cox ã Brian Vosberg ã Rosann Magnifico ã John Peugeot â Web Information Team ã Asli Kumcu.
Parametric Study of Daylighting Strategies with Consideration of Glare Problems Case Study: IGES Research Center in Zushi Santiago L. Torres Sakamoto Laboratory.
1 THE OFFICE 2 OFFICE PROJECT COLLABORATION SYSTEM.
VYKON Tenant Billing Service
Deriving Lights from Pixels Presented By: WAIL ALI EL EBEEDY By: By: Web Address: ArchitectureWeek - Tools - Deriving Lights from Pixels _0528.htm.
Energy Saving Climate Control System (ESCCS) Team: Sean Jacobs, Brad Nissenbaum, Colin Tracy Advisor: Professor Anderson.
Daylighting Prediction Tool Online Presented By: Eng.Reham Mostafa Mohamed Mohie El-Din By: Christoph Reinhart Web Address:
NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy operated by the Alliance for Sustainable.
Universe Design Concepts Business Intelligence Copyright © SUPINFO. All rights reserved.
80 years of excellence Commercial Buildings Tax Deduction Ed Gray Director, Energy Infrastructure National Electrical Manufacturers Association.
ENVIRONMENTAL DATA MANAGEMENT & SHALE GAS PROGRAMS INTERNATIONAL PETROLEUM ENVIRONMENTAL CONFERENCE NOVEMBER 14, 2013.
© 2006 ITT Educational Services Inc. CD230 Architectural Design & Drafting: Unit 1 Slide 1 The DesignCenter and VIZ Render in ADT.
RoboTutor In Perspective: What it does…. RoboTutor in Perspective… Need Training Employees & Students.
Web-Enabling the Warehouse Chapter 16. Benefits of Web-Enabling a Data Warehouse Better-informed decision making Lower costs of deployment and management.
NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy operated by the Alliance for Sustainable.
CPSC 203 Introduction to Computers T03 & T29 by Jie (Jeff) Gao.
EC-Net AX EnerVue™ Energy Management Dashboard. Presentation Overview  EC-Net AX EnerVue  Introduction to Energy Management Dashboards  EC-Net AX EnerVue.
Decision analysis and Risk Management course in Kuopio
RenderToolbox A MATLAB Toolkit for Hyperspectral Rendering with Radiance and PBRT Daniel P. Lichtman, Bei Xiao, David H. Brainard.
WHAT NEEDS TO BE COMMISSIONED IN ZERO ENERGY BUILDINGS 1 What needs to be Commissioned in Zero Energy Buildings? Jorge Torres Coto.
Ballenger East Building Final Presentation Design Development Architectural Engineering Senior Thesis Presentation 2009 Lighting / Electrical Option Student.
Ken YoussefiIntroduction to Engineering – E 10 1.
State of Connecticut Core-CT Project Query 4 hrs Updated 1/21/2011.
Benchmarking Energy Use in Commercial Buildings Satish Kumar, Ph.D. Lawrence Berkeley National Laboratory Public Sector Energy Management Workshop Mumbai,
Students: Nadia Goshmir, Yulia Koretsky Supervisor: Shai Rozenrauch Industrial Project Advanced Tool for Automatic Testing Final Presentation.
FIRST COURSE Excel Tutorial 1 Getting Started with Excel.
Cloud computing is the use of computing resources (hardware and software) that are delivered as a service over the Internet. Cloud is the metaphor for.
Microsoft Office Illustrated Fundamentals Unit L: Creating Database Reports.
1 Research Groups : KEEL: A Software Tool to Assess Evolutionary Algorithms for Data Mining Problems SCI 2 SMetrology and Models Intelligent.
Benjamin Welle Stanford University Grant Soremekun Phoenix Integration
Presented by: 15 Oct 2001 Neptec Laser Camera System Preliminary Post Flight Results Neptec Design Group.
ARCH-4372/6372 Technology in Architecture Spring, 2015.
WebVizOr: A Fault Detection Visualization Tool for Web Applications Goal: Illustrate and evaluate the uses of WebVizOr, a new tool to aid web application.
Microsoft Office 2007 Intermediate© 2008 Pearson Prentice Hall1 PowerPoint Presentation to Accompany GO! With Microsoft ® Office 2007 Intermediate Chapter.
CUAHSI HIS Survey at Berkeley Seongeun Jeong and Xu Liang Department of Civil & Environmental Engineering UC Berkeley.
Supporting further and higher education The Akenti Authorisation System Alan Robiette, JISC Development Group.
GSA Early Concept Design Project – Energy Analysis
Visualizing illuminance levels, generated in Radiance, in a Maya environment Richard Gillibrand & Patrick Ledda University of Bristol, UK Richard Gillibrand.
1 Research Question  Can a vision-based mobile robot  with limited computation and memory,  and rapidly varying camera positions,  operate autonomously.
Tools for rapid architectural lighting analysis Daniel Glaser 1, Osbert Feng 2, Jan Voung 2, Ling Xiao 2, John Canny 2, Ellen Yi-Luen Do Radiance.
Environmental Energy Technologies Contractorstalk.ppt Climate Contractors’ Showcase: A look at LBNL Jonathan Koomey, Ph.D. Lawrence Berkeley National Laboratory.
Building Dashboards SharePoint and Business Intelligence.
Chapter 3 Response Charts.
Advanced Lighting Control Systems (ALCS) Energy Estimation Tool Pacific Gas & Electric Company Dave Alexander.
Columbus Signature Academy New Tech Campus – Phase 1 Columbus, Indiana Lee J. Brockway Award Renovations High School CSO Architects 2009 Exhibition of.
Advanced Science and Technology Letters Vol.32 (Architecture and Civil Engineering 2013), pp A Preliminary.
Objectives Learn about daylighting Review lighting -terminology -technology -design.
The National Research and Training Institute for the Blind Allison Brown Lighting/ Electrical Option April 17 th, 2003.
16469 Low Energy Building Design Conflict and Interaction in Environmental Engineering Design.
Microsoft Office 2013 Try It! Chapter 4 Storing Data in Access.
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley.
A. Sim, CRD, L B N L 1 SRM Collaboration Meeting, Sep , 2005 SRM v3.0 LBNL Implementation Status Report Scientific Data Management Research Group.
RENDERING : Global Illumination
Prepare for the Possibility: Response and Recovery Steve Goddard Computer Science & Engineering University of Nebraska-Lincoln.
BIM EXECUTION PLANNING PROCESS
BEEP Integrated Design Process for Energy Efficient Buildings
BIM EXECUTION PLANNING PROCESS
Climate Based Daylight Modelling
Intermountain West Data Warehouse
Chapter 9 Architectural Design.
In Perspective: What it does…
Designing Goals Inventory Existing and Planned Conditions
Presentation transcript:

Lighting Lab Online Presented By: Omar Yehia Omar Elshrief By: Konstantinos Papamichael Web Address: : 120 Topic Number : 120 Date: 29 January 2003

Lighting Lab Online -To help architects, engineers, lighting designers, and consultants meet or exceed the increasingly stringent requirements of the California building energy efficiency standard known as Title 24, Southern California Edison and other utility companies have been developing tools for the Savings by Design program. These tools aim to help building designers, owners, and managers who often lack an easy way to assess daylighting and electric lighting performance.Southern California Edison Savings by Design -Informed lighting include window size and orientation decisions take into consideration key factors that affect energy use and the quality of the luminous environment. These factors, glazing type, luminaire types and layout, and reflectance of interior surfaces, among others.

-To consider daylighting and electric lighting performance properly, decision makers need to use lighting simulation tools, which compute work-plane illuminance and, in many cases, surface luminance values. However, such tools often have long learning curves and may be time consuming to use, which can increase design costs. -To provide an option for assessing lighting designs without running detailed simulations, we at the Building Technologies Department of the Environmental Energy Technologies Division (EETD) at Lawrence Berkeley National Laboratory (LBNL) are developing a Web-based tool that allows lighting and daylighting designers to quickly and easily assess the effects of key parameters on qualitative and quantitative aspects of daylighting and lighting performance. The Virtual Lighting Simulator displaying differences in daylight due to two glazing types in a small office. A simulation of changes in electric lighting system and wall/ceiling reflectance in two small offices.

Simulating Lighting Scenarios The tool uses a large database of images and statistical data, which were generated through many parametric lighting simulations in prototypical architectural spaces. The data were generated with the Radiance lighting simulation and rendering software.Radiance The new Web-based tool, known as the "Virtual Lighting Simulator," allows users to change the values of key design and context parameters and displays the corresponding images and data for qualitative and quantitative assessment of luminous performance. The current version includes two main modules, one for assessing daylighting in a small office space and the other for electric lighting in five space types: a classroom, a small office, a large open office with partitions, a large warehouse, and a small retail store.Virtual Lighting Simulator False-color" display of the lighting differences between two configurations of a classroom setting. Display of the difference between camera exposure (left) and human perception (right) in a warehouse space.

Presenting Results -The Web-based user interface allows quick and easy selection of values for the key parameters that were varied in the simulations, and the tool provides an instant response in the form of a display of previously calculated images and data. -The user interface is designed to allow side-by-side comparisons of alternative scenarios or of the same scenario in different display modes. The four display modes are a "camera exposure" display, which is the equivalent of what a camera would produce in an average exposure mode; a "human perception" display, which adjusts the image to reflect the sensitivity and adaptation of the human eye; and "iso-contour" and "false-color" displays, for quantitative assessment. -The output includes perspective views of the architectural spaces, showing luminance values, and plan views, showing work-plane illuminance values. Quantitative statistical information is also provided in the form of minimum, average, and maximum work-plane illuminance.