On the origin of Differential Crosstalk in segmented detectors B. Bruyneel for the AGATA week, Uppsala, Sweden July 2008.

Slides:



Advertisements
Similar presentations
Detector Characterisation Group
Advertisements

Advanced GAmma Tracking Array
Introduction This project used cosmic rays to test a prototype Minimum Bias Trigger Scintillator (MBTS) that will be used in the ATLAS experiment at CERN.
GRAPE(Gamma-Ray detector Array with Position and Energy sensitivity) Developed at CNS for in-beam  -ray spectroscopy with High Resolution M.
SmartPET: A Small Animal PET Demonstrator using HyperPure germanium Planar Detectors R. Cooper 1 st year PhD Student
Pulse Shape Analysis with Segmented Germanium Detector Xiang Liu, Max-Planck-Institut für Physik 1.Motivation 2.Pulse properties 3.Analysis procedure 4.Some.
AGATA Introduction John Simpson Nuclear Physics Group.
First complete test measurements of the AGATA Core _ Pulser Assembly. AGATA Core Pulser, Segments Bulk Capacitances (First measurements of the Pulser Core.
OVERVIEW NEDA Introduction to the Simulations – Geometry The Simulations Conclusions 3.7% This work summarizes the introduction to the simulations of.
EELE 461/561 – Digital System Design Module #5 Page 1 EELE 461/561 – Digital System Design Module #5 – Crosstalk Topics 1.Near-End and Far-End Crosstalk.
University of Milano Department of Physics and INFN HIGH DYNAMIC RANGE LOW-NOISE PREAMPLIFICATION OF NUCLEAR SIGNALS A. Pullia, F. Zocca, C. Boiano, R.
R&D on CsI(Tl) + APD Optimisation of the energy resolution M. Gascón I.Durán.
AGATA Core - upgraded front end electronics
RlRl A R fb C fb C ac +Bias A R fb C fb A R bf C fb v0v0 v1v1 v2v2 V 0,out V 1,out V 2,out A simple detector model to describe crosstalk in segmented detectors.
What Happened Yesterday Steve Holt *ADC speed does not necessarily depend on clock speed; GHz crystal not needed Mihir Ravel *Voltage tolerance of the.
TOF at 10ps with SiGe BJT Amplifiers
Depletion Region Dynamics of an AGATA Detector Steven Moon University of Liverpool UNTF 2010, University of Salford 14 th -16 nd April 2010.
TRACKING TEAM Introduction What has been done What still needs to be done.
AGATA 2 nd Prototype Detector Initial Measurements & Evaluation Andrew Boston, Matthew Dimmock, Laura Nelson, Sarah Rigby.
Characterisation & PSA Team Meeting Presentations –Liverpool Status, Andy Boston/Matt Dimmock (Liverpool) –Crosstalk properties of AGATA detectors, Bart.
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
Beta and particle decay spectroscopy at the Super FRS Zenon Janas Nuclear Spectroscopy Division Warsaw University.
AIDA design review Davide Braga Steve Thomas ASIC Design Group 9 June 2009.
Decay Data in View of Complex Applications Octavian Sima Physics Department, University of Bucharest Decay Data Evaluation Project Workshop May 12 – 14,
J.N. Wilson, EFNUDAT workshop, CERN, August 2010 Level Densities, Decay Probabilities and Cross sections in the Actinide Region J.N. Wilson Institut de.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Detectors and Preamplifiers Detector deliveries Customer Acceptance Tests Available detectors AGATA triple detectors Scanning program P. Reiter IKP University.
Teams: Simulation of key experiments Gamma-ray tracking Data analysis Databases Simulation and Data Analysis Working Group Department of Radiation Sciences.
Wolfram KORTEN, JRA-02 AGATAEURONS PCC-Meeting, Mainz (Germany), April 2006 Status of the AGATA project Recent developments Milestones and deliverables.
B.Satyanarayana. B.Satyanarayana INO Weekly meeting June 8, Rise time: 2 to 3ns Pulse height: mV.
July 10, 2001LArg Meeting1 Electronic Simulation Work at Victoria and TRIUMF Victoria: Erica Muzzerall, Dr. Richard Keeler TRIUMF: Dr. Chris Oram.
Analysis of S002 scan data Bart Bruyneel and Benedikt Birkenbach – IKP Cologne At the 7 th AGATA week, Uppsala July S003.
 -tracking uses segmented detectors which are characterized by xTalk  Traces are modified in shape and amplitude  Energy effects: peak shifts and resolution.
DESPEC A Algora IFIC (Valencia) for the Ge array working group.
Chromaticity dependence of the vertical effective impedance in the PS Chromaticity dependence of the vertical effective impedance in the PS S. Persichelli.
SIAM M. Despeisse / 29 th January Toward a Gigatracker Front-end - Performance of the NINO LCO and HCO Matthieu Despeisse F. Osmic, S. Tiuraniemi,
AHCAL Electronics. SPIROC2 and HBU measurement results Mathias Reinecke CALICE main meeting Univ. HASSAN II, Casablanca, Morocco Sept. 23rd, 2010.
BACKGROUND REJECTION AND SENSITIVITY FOR NEW GENERATION Ge DETECTORS EXPERIMENTS. Héctor Gómez Maluenda University of Zaragoza (SPAIN)
 Digitisation P.Medina  Pre-processing I.Lazarus GTSM.Bellato GTSM.Bellato  PSA P.Desesquelle R.Gernhäuser 7 th AGATA Week, Uppsala, July 8-11, 2008.
Front-End Electronics for G-APDs Stefan Ritt Paul Scherrer Institute, Switzerland.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
 Number of signals used  Type of signals  Tests with regular and irregular grids  Last results  New idea for minimization function Roberto Venturelli.
Detector Module Three 36-fold segmented detectors 111 preamplifiers Cryostat Jürgen Eberth University of Cologne Detector Team: Dirk Weißhaar Preampl.
Veljko Radeka: Notes on the origin of charge amplifiers July2,
PSA: ADAPTIVE GRID SEARCH The Method Experimental Results Optimization aspects Roberto Venturelli (INFN Padova - IPSIA “Giorgi” Verona) SACLAY, 05-may-06.
Steven Moon, A.J. Boston, H. Boston, J. Cresswell, L. Harkness, D. Judson, P.J. Nolan PSD9, Aberystwyth, Wales th September 2011 Compton imaging.
Simulating the position sensitivity of the iThemba LABS segmented clover detector S. P. Noncolela 1, 2, T. D. Bucher 1, E. A. Lawrie 1, O. Shirinda 1,
I.2. Radio-detection of extensive air showers Part II Olivier Martineau-Huynh TREND workshop, April 19, 2013.
CERN PH MIC group P. Jarron 07 November 06 GIGATRACKER Meeting Gigatracker Front end based on ultra fast NINO circuit P. Jarron, G. Anelli, F. Anghinolfi,
Recent progress in ultra-low noise, ultra-low background detectors V. Marian, M.O. Lampert, B. Pirard, P. Quirin CANBERRA France (Lingolsheim) Workshop.
Advanced Implantation Detector Array (AIDA): Update & Issues Tom Davinson School of Physics The University of Edinburgh presented by Tom Davinson on behalf.
DC bias circuit effects in CV measurements A.Chilingarov, D.Campbell Lancaster University, UK 9 th RD50 Workshop CERN,
SEP Pre-PDR Peer Review DFE and DAP Electronics May 11, 2010
AGATA Pulse Shape Analysis Implementation
Detector characterization overview of the AGATA scanning tables
CTA-LST meeting February 2015
Efficiency versus energy resolution
Detectors and Preamplifiers
HPD with external readout
AGATA Detector Work Performed at Saclay in lessons learned -
CAT of AGATA detectors &
K. Sedlak, A. Stoykov, R. Scheuermann
Lecture 2: Basic Operation of Gas-filled Detectors Unit II, Gas-filled Detectors "Enrico Fermi," Microsoft® Encarta® Online Encyclopedia
Status of n-XYTER read-out chain at GSI
On the origin of Differential Crosstalk in segmented detectors
AGATA week Uppsala, July 2008
Status report Detector team
Adapted from D. Bazzacco 2012 EGAN school lecture
Efficiency versus energy resolution
Werner Riegler, Christian Lippmann CERN Introduction
Presentation transcript:

On the origin of Differential Crosstalk in segmented detectors B. Bruyneel for the AGATA week, Uppsala, Sweden July 2008

Crosstalk is present in any segmented detector Influences energy: Creates strong energy shifts proportional to fold Influences PSA: Crosstalk mixes with transient signals Fast and accurate crosstalk detection and energy correction methods developed To Do : Crosstalk measurement and correction in PSA Sum of segment Energies vs fold Cross talk analysis: Motivation Xtalk signal:

Crosstalk in all its forms PA V 0,out V 1,out PA Z in Z 01 Xtalk ~ Z in / Z 01 Proportional Xtalk model : Z in = Miller = 1/sAC fb But: Miller does not explain risetime of preamplifier…! Proportional Xtalk (50  s decay)  Energy Differential Xtalk (only during risetime)  PSA Pure Xtalk signal:

Preamp model describing risetime V out /I in = Z fb Z in = V in /I in Z in = Z fb /A + R cold “ Cold Resistor ” : - E. Gatti and P. Manfredi – Il Nuovo Cimento vol. 9 serie 3 (1986) - “Analogue circuits techniques Part II ” F. Anghinolfi, CERN (2002) – (available online) PA V out V in I in

Xtalk extension PA V 0,out V 1,out PA Z in Z 01 With Z in = 1/sAC fb + R cold Xtalk ~ Z in / Z 01 = C 01 /AC fb + s. R cold C 01 Proportional + Differential Xtalk Example : R cold = 1k  ; C 01 = 10pF Differential Xtalk = 1000%ns Warning: Other ways possible to create Derivative Xtalk !

Realistic simulation (Multisim) PA V 0,out V 1,out PA 10pF Realistic Preamp model V 0,out V 1,out

Differential Xtalk from Proportional Xtalk? A2..A6 B1 F1 Core to seg capacity Segment labeling: Sectors: A...F Rings: X Seg to seg capacities? Differential Xtalk will show up in adjacent segments and within same sector

How to measure …? (1)B. Bruyneel et al. NIM A 569 (2006) / MGS workshop (April 2005) / AGATA week (Nov 2005)

How to measure…? (2) “Pulse Shape Characterization and Simulation for the TIGRESS Gamma-ray Detector “ Thesis Robin Prest TRIUMF “Differential Analysis” using mirror interaction points: “differences from transients of mirror interactions are pure”  (a,b) (b,a) Differential analysis. for simulation (green) and experiment (red) Simulated signal (green) compared to experimental signal (red) suffering from cross-talk