Timing and synchronisation to ISIS RF Edward Overton 1.

Slides:



Advertisements
Similar presentations
Sentricon: How To Guide. How to Enter a New Sentricon Job First create a new service setup on the customer’s account.
Advertisements

Muons going through MICE should –Have ISIS proton timing structure –Generate TOF signals –Satisfy ISIS and TOF trigger requirements MICE tracker DAQ will.
MICE Target Electronics, DAQ and BPS MICE/ISIS Target Meeting 17 th September 2010 P J Smith – University of Sheffield.
ICS Test Environment Alexander Söderqvist Dec 9, 2014.
Daresbury Aug 2005Jean-Sébastien Graulich Detector DAQ Overview and Needs Jean-Sebastien Graulich, Univ. Genève o Introduction o Detector Systems Overview.
DAQ WS03 Sept 2006Jean-Sébastien GraulichSlide 1 Wrap Up o Control and Monitoring o DDAQ o Interface between DDAQ and MCM o Infrastructure Jean-Sebastien.
Tracker DAQ Makoto Yoshida (Osaka Univ.) MICE Frascati 2005/6/27.
DAQ WS02 Feb 2006Jean-Sébastien GraulichSlide 1 DDAQ Hardware Architecture o General Architecture o Tracker Baseline o TOF Baseline & Options o EmCal Baseline.
1 VLPC system and Cosmic Ray test results M. Ellis Daresbury Tracker Meeting 30 th August 2005.
MICE CM15 June 2006Jean-Sébastien GraulichSlide 1 DAQ Status o Detector DAQ Test bench in Geneva o Preparing for Test Beam o FE electronics tests o Detector.
Luminosity Monitor Commissioning MICE Collaboration Meeting March 2010 Paul Soler, David Forrest Danielle MacLennan.
VME readout fro TOF MICE Tracker Meeting 30 March Paul Soler, Kenny Walaron University of Glasgow and Rutherford Appleton Laboratory.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
MICE CM17 Feb 07Jean-Sébastien GraulichSlide 1 Detector DAQ Status o Since CM16 o Detector DAQ software o Front End Electronics o Schedule Milestones o.
DAQ WS03 Sept 2006Jean-Sébastien GraulichSlide 1 DDAQ Trigger o Reminder: DAQ Trigger vs Particle Trigger o DAQ Trigger o Particle Trigger 1) Possible.
MOM - M.ApollonioAccel. R&D/Physics and IADR - RAL - 19/3/ Summary of MICE operations – 14/15 March 2008 AIMS - establish MICE beamline in ISIS synchrotron.
M. Bonesini DAQ Meeting1 M. Bonesini INFN Milano Some Considerations for MICE TOF Stations FE electronics (mainly TOF0)
1M. Ellis - MICE Video Conference - 15th March 2007 Software Report  New G4MICE Users  TOF Simulation and Digitisation  SciFi Reconstruction  Tracker.
Takashi Matsushita Imperial College T. Matsushita 1 Tracker Status.
LHC Beam Dump System Technical Audit Trigger Synchronisation Unit.
MICE CM18 June 07Jean-Sébastien GraulichSlide 1 Detector DAQ Status o Since CM17 o Detector DAQ software o Front End Electronics o Schedule Milestones.
K.C.RAVINDRAN,GRAPES-3 EXPERIMENT,OOTY 1 Development of fast electronics for the GRAPES-3 experiment at Ooty K.C. RAVINDRAN On Behalf of GRAPES-3 Collaboration.
DAQ MICO Report Online Monitoring: –Status All histograms are now implemented Still not fully online –Only monitoring from data file (slightly offline,
MICE CM25 Nov 2009Jean-Sebastien GraulichSlide 1 Detector DAQ Issues o Achievements Since CM24 o Trigger o Event Building o Online Software o Front End.
Some features of V1495 Shiuan-Hal,Shiu Everything in this document is not final decision!
September 7/04Cyclotron Development Meeting. Improvement TOF Possible TOF improvements.
Configuration Database Antony Wilson MICE CM February 2011 RAL 1.
1 MICE Tracker Readout Update, Preparation for Cosmic Ray Tests Cosmic Ray Tests at RAL AFE-IIt Firmware Development VLSB Firmware Development Summary.
DAQ WS03 Sept 2006Jean-Sébastien GraulichSlide 1 Control and Monitoring Summary of DAQ WS III o General Architecture o RF System C&M o D0 EPICS extensions.
‘Dude where's my muon?’ Trigger Efficiency of the Single Station. Edward Overton 1.
Luminosity Monitor UKNF Meeting 7 June 2010 Paul Soler, David Forrest Danielle MacLennan.
Timing Requirements for Spallation Neutron Sources Timing system clock synchronized to the storage ring’s revolution frequency. –LANSCE: MHz.
Tracker Timing and ISIS RF Edward Overton 1. At CM32… 2 Had done some preliminary checks on the ISIS RF. Was beginning to think about how to handle the.
January 31, MICE DAQ MICE and ISIS Introduction MICE Detector Front End Electronics Software and MICE DAQ Architecture MICE Triggers Status and Schedule.
Online Reconstruction 1M.Ellis - CM th October 2008.
DAQ Status for cosmic-ray test in RAL Hideyuki Sakamoto MICE Phone meeting 12 th July 2007 Contents Status Setup for cosmic-ray test bench Schedule.
1Malcolm Ellis - Tracker Meeting - 28th November 2006 Electronics - Station Acceptance  Hardware: u 1 MICE cryostat with 1 VLPC cassette. u VME crate,
1 A first look at the KEK tracker data with G4MICE Malcolm Ellis 2 nd December 2005.
Linda R. Coney – 5 November 2009 Online Reconstruction Linda R. Coney 5 November 2009.
M. Ellis - MICE Collaboration Meeting - Thursday 28th October Sci-Fi Tracker Performance Software Status –RF background simulation –Beam simulation.
MICE CM28 Oct 2010Jean-Sebastien GraulichSlide 1 Detector DAQ o Achievements Since CM27 o DAQ Upgrade o CAM/DAQ integration o Online Software o Trigger.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
Time and amplitude calibration of the Baikal-GVD neutrino telescope Vladimir Aynutdinov, Bair Shaybonov for Baikal collaboration S Vladimir Aynutdinov,
Tracker Cosmic Ray Test 2011 Linda R. Coney UC Riverside CM 29 - February 16, 2011.
Detector Summary Tracker. Well, as far as the tracker hardware is concerned, we are done. – Need to do the system test to make sure nothing has degraded.
January 17, MICE Tracker Firmware Dead Time and Muon Detection Studies for the MICE Tracker Tracker Data Readout Basics Progress in Increasing Fraction.
Status of MAPMT FEE Electronics Boards Connector board – have 5 boards, 1 assembled Readout board (“MUX” board) – layout completed 12/2, but unfortunately.
MICE CM February 08Jean-Sébastien GraulichSlide 1 Report on DAQ & CAM o Detector DAQ Status Hardware Trigger Software o Controls and Monitoring (CAM) o.
Tracker Readout Progress Terry Hart, MICE Tracker Meeting, July 29, 2008 Cosmic Ray Readout with 1 st Tracker at RAL 2 nd Tracker Preparation at FNAL Firmware.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
1 DATE-based DAQ Hideyuki Sakamoto CM22, RAL 19/10/08.
Evelyn Thomson Ohio State University Page 1 XFT Status CDF Trigger Workshop, 17 August 2000 l XFT Hardware status l XFT Integration tests at B0, including:
1 Timing of the calorimeter monitoring signals 1.Introduction 2.LED trigger signal timing * propagation delay of the broadcast calibration command * calibration.
VC98 March 07Jean-Sébastien GraulichSlide 1 DDAQ Status o DAQ Software o Front-End and Trigger o What will happen soon o Schedule Milestones Jean-Sebastien.
KM2A PMT testing platform FENG Cunfeng, LI Chaoju, SUN Yansheng Shandong University THE 2 nd WORKSHOP OF AIR SHOWER DETECTION AT HIGH ALTITUDES IHEP, Beijing,
S-2S meeting Toshiyuki Gogami 15 Oct Contents TOF detector Kyoto University.
Doubling the Target Insertion Rate P J Smith for MICE VC 163.
MADEIRA Valencia report V. Stankova, C. Lacasta, V. Linhart Ljubljana meeting February 2009.
L. Coney UC Riverside MICE CM32 – Glasgow – June 2012
DAQ Requirements M. Villa 21/02/2011.
Tracker readout, DAQ, C&M and calibration
Jean-Sebastien Graulich, Geneva
The procedure for noise rate measurement of BBC’s PMTs
MICE AFEIIt Timing and Triggering
Muon Recording Studies and Progress for the MICE Tracker
Sergey Abrahamyan Yerevan Physics Institute APEX collaboration
BESIII EMC electronics
ECE 554 HW Tutorial Spring Good afternoon everyone.
Particle ID Diagnostics in the MICE Beamline
Wavewin Sniffer 24 Configuration & Polling Software
Presentation transcript:

Timing and synchronisation to ISIS RF Edward Overton 1

Contents Handling of the ISIS RF The MICE trigger configuration for the Single Station test. Delay measurements Trigger rate Timing to MICE 2

Handling the RF The goal of processing the ISIS RF is to produce windows that can be moved around to meet the particles / triggers. The RF is handled by two delay boxes working together configurable over Ethernet. The second delay box triggers when the first is ‘busy’. 3

Handling the RF Timing diagram for single channel of the delay box. Can Adjust Delays and Width independently. Maximum Frequency = 2/( Delay + Width + Dead time(60ns) + Safety(10ns) ) Delay + Width = 575ns 4

Configuration of the delay boxes Used a simple CLI python script to configure the delay boxes for the Single Station Test. The script saved a record of every setting downloaded to the delay boxes with a hard coded filename (so it will be possible to read/reload them later). 5 [miceacq11] delayTest >./setTrackerTiming.py -h _____ _ _____ _ _ |_ _| | | |_ _(_) (_) | |_ __ __ _ ___| | _____ _ __ | | _ _ __ ___ _ _ __ __ _ | | '__/ _` |/ __| |/ / _ \ '__| | | | | '_ ` _ \| | '_ \ / _` | | | | | (_| | (__| < __/ | | | | | | | | | | | | | | (_| | \_/_| \__,_|\___|_|\_\___|_| \_/ |_|_| |_| |_|_|_| |_|\__, | ============================================================ __/ | Configuration and Download Script |___/ usage: setTrackerTiming.py [options] This script calculates and downloads settings to the T560 Delay boxes, in order to configure the alive window and integration windows for the tracker. options: -h, --help show this help message and exit -c CFGFILE, --config=CFGFILE read delay configuration from CFGFILE -v, --verbose Print out everything --logs=LOGDIR destination to place configuration logfiles --skipconfigure skip the configuration step --skipdownload skip the download step

Implementation 6

7 MICE Trigger Logic for the SST

Delay Measurements Have started combining the measurements taken during the single station test. Adding the signal delay though each piece of equipment into an spread sheet  Have found some missing measurements (guestimate for the moment, will check when at RAL). So far a summary: 8 Delay (ns) Integration window (RF->AFE)324 Alive window (RF->Veto)34 TOF Signal (PMT signal->Logic pulse in MICE trigger)306 LED Trigger (Voltage pulse in SS -> Logic pulse in MICE trigger)332 Logic pulse in MICE trigger -> VLSB Trigger619 Integration window delays DescriptionDelay(ns)Total Delay (ns) Patch Cable22 TTL->NIM Conversion?79 Patch Cable211 Logic Fan In/out718 Patch Cable220 NIM->TTL Conversion?727 Patch Cable431 Cable to Hall? Patch Cable2283 V976 Fan out9292 Cable to AFE32324

Trigger Rate 9 We measured the effect of the alive window on the trigger rate, while moving the alive window. There was no digitisation dead time included for this study for the tracker (normally 6us). We recorded the number of triggers on the scalars for 10+ spills. On average there were 150 Triggers / spill. Later I took a specific run where I varied the particle triggers from 120/spill to 9/spill using the target. I excluded the digitisation window so that one could be applied later and we can see how it effects the rate.. Would this be useful?

Timing to other Detectors 10 The tracker calculates time relative to the end of an integration window. The TOFs record the relative time of the particle trigger.. A possible plan to link the two Not sure how far back to go… Hopefully should visit Yordan while he is MOM so we can have a go at this… Integration Window Particle Trigger TOF PMT->TDC Trigger Integration Window TDC Particle Trigger TDC Integration window transmit time to hall.