Results Conclusion Methods Samples Peak current limiting properties of SFCL with parallel connected coils using two magnetic paths Objectives Background.

Slides:



Advertisements
Similar presentations
AP Physics C Montwood High School R. Casao
Advertisements

Induction motor Course no: EE 3107 Md. Nur Kutubul Alam Lecturer
ENERGY CONVERSION ONE (Course 25741)
Chapter 11 Inductors.
CURRENT TRANSFORMERS AND VOLTAGE TRANSFORMERS
Magnetism Alternating-Current Circuits
ENERGY CONVERSION ONE (Course 25741)
Review 29:008 Exam 3. Ch. 12 Electrostatic Phenomena.
T. YOSHIDA, J. OYAMA, T. HIGUCHI, T. ABE and T. HIRAYAMA Department of Electrical and Electronic Engineering, Nagasaki University, Japan ON THE CHARACTERISTICS.
Power System Fundamentals
The current through the inductor can be considered a sum of the current in the circuit and the induced current. The current in the circuit will be constant,
Magnetic Circuits and Transformers
Alternating Current Circuits
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 15 Magnetic Circuits and.
Magnetics Design Primary Constraints:
Transformer.
Transformers.
22/12/2014.
AP Physics C Montwood High School R. Casao
Main article: Leakage inductance
DC GENERATOR CHAPTER-9.
Department of Electrical and Computer Engineering
Transformers Mechanical and Electrical Systems SKAA 2032
Basic Electronics Ninth Edition Basic Electronics Ninth Edition ©2002 The McGraw-Hill Companies Grob Schultz.
BENE 1113 PRINCIPLES OF ELECTRICAL AND ELECTRONICS
Electrical principles. The aim of today is to understand the average and RMS values in an AC circuit. Objectives: To know how alternating current is produced.
Electrical principles. Session 1 a.c circuits Objectives: To know how alternating current is produced To understand what average and RMS values are, in.
Passive components and circuits
Single Phase Transformer
Electricity and Magnetism 29 Alternating Currents and Power Transmission Chapter 29 Alternating Currents and Power Transmission.
ELECTROMAGNETICS PREPARED BY: Patel Bhavik V Patel Nirav A. BE First Semester Electrical Engineering ACTIVE LEARNING ASSIGNMENTS.
Elec467 Power Machines & Transformers
Inductance and AC Circuits. Mutual Inductance Self-Inductance Energy Stored in a Magnetic Field LR Circuits LC Circuits and Electromagnetic Oscillations.
EET 103 Transformer Chapter 5 1. A transformer is a device that changes ac electric energy at one voltage level to ac electric energy at another voltage.
EET 221 Synchronous Machines Rafiqi.
BASIC ELECTRICAL TECHNOLOGY Chapter 6: Single Phase Transformer
Chapter 2 Transformers Edit by Chi-Shan Yu Electric Machinery.
3/17/2014 PHYS , Dr. Andrew Brandt 1 PHYS 1442 – Section 004 Lecture #15 Monday March 17, 2014 Dr. Andrew Brandt Chapter 21 Generator Transformer.
Monday, April 23, PHYS , Spring 2007 Dr. Andrew Brandt PHYS 1444 – Section 004 Lecture #19 Monday, April 23, 2007 Dr. Andrew Brandt Inductance.
1 ELECTRICAL TECHNOLOGY EET 103/4 Define and analyze the principle of transformer, its parameters and structure. Describe and analyze Ideal transformer,
1 ELECTRICAL TECHNOLOGY EET 103/4 Define and analyze the principle of transformer, its parameters and structure. Describe and analyze Ideal transformer,
BASIC ELECTRICAL TECHNOLOGY DET 211/3
POWER CIRCUIT & ELECTROMAGNETICS EET 221 Transformer.
Soumen Kar 1,2, Xiao-Fen Li 1, Venkat Selvamanickam 1, V. V. Rao 2 1 Department of Mechanical Engineering and Texas Center for Superconductivity University.
SMJE 2103 Synchronous Generator. Scope of discussion 1)Construction 2)Rotation speed 3)Generated voltage 4)Equivalent circuit 5)Power and Torque 6)Testing.
1 :. Introduction These are special type of transformers used for the measurement of voltage, current, power and energy. As the name suggests, these transformers.
Parul Institute Of Technology Name Of Subject:-Electrical Machines Name Of Faculty:-(1) Suresh Sahoo (2) Yogendra Tiwari E&C 3 rd Sem. Prepaid By :- Sr.No.NameEnrolment.
True-False Questions. A magnetic core material may exhibit hysteresis or saturation but not both.
Lesson 25: Magnetism and Transformers
DCMT PRESENTATION DEVANSH KHARE ( )
Mutual Inductance Mutual inductance: a changing current in one coil will induce a current in a second coil: And vice versa; note that the constant M, known.
TRANSFORMER A transformer is a static device.
Lesson 8: Ideal Transformer Theory and Operation
True-False Questions.
Alternating Current Module
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
Quench estimations of the CBM magnet
MMI^2T limits for magnets, what are they and how where they developed
Principles & Applications
Transformer -Types & Applications
Transformers. Transformer An A.C. device used to change high voltage low current A.C. into low voltage high current A.C. and vice-versa without changing.
Electromechanical Systems
Energy Conversion and Transport George G. Karady & Keith Holbert
Energy Conversion and Transport George G. Karady & Keith Holbert
Energy Conversion and Transport George G. Karady & Keith Holbert
19 Inductance Chapter Topics Covered in Chapter 19
TRANSFORMER.
Chapter 1 Introduction to Machinery Principles
Quench calculations of the CBM magnet
Unit-1 Transformer.
Presentation transcript:

Results Conclusion Methods Samples Peak current limiting properties of SFCL with parallel connected coils using two magnetic paths Objectives Background Seok-Cheol Ko 1 and Sung-Hun Lim 2 * 1 Industry-University Cooperation Foundation, Kongju National University, Chungnam, , Republic of Korea 2* Department of Electrical Engineering, Soongsil University, Seoul , Republic of Korea Presented at the Cryogenic Engineering Conference and International Cryogenic Materials Conference, 2015 June 28 –July 2, Tucson, Arizona; Session: Cryogenics for Power Applications, Energy, Fuels and Transportation I; Program I.D. number:C1PoA-04 [C4] a superconducting fault current limiter (SFCL) has been considered as a very effective way to reduce the fault current with its nature of zero electric resistance in the normal condition, which neither incur loss nor influence the system. Most of the existing relative researches have been on either the load to handle the fault current during the period of limiting operation or the operating characteristics and its effectiveness after improving the adjustment of impendence, because sensing the fault current and limiting operating of fault current occur simultaneously. DimensionsExperimental Preparation Structure and principle In the case of a great fault current, it can decrease the load of the fault current by enabling two times of current limit resections occur from two superconducting elements. Its structure consists of three coils and two superconducting elements around the three-leg E-I iron core. E-I iron core is the combined form of E and I. It enhances the inductance value and prevents the sudden magnetic flux saturation. It also prevents the magnetic field from escaping to another place when the iron core forms a magnetic circuit. Equivalent circuit L1, L2, and L3 show the inductance of each coil. Rsc1 and Rsc2 show the resistance of each superconducting element. In order to simplify the description of the equivalent circuit, the mutual inductance between coils is omitted. The size of the fault current, which initiates the current limit action of SFCL having two magnetic paths in parallel, can be induced from the electric equivalent model. Like Formula (1), the equation of the first operating current, the value of SFCL about the first fault current limit action, can be set up with controlling L1, and L2, and IC. The Eq.(2) of the second operating current for the second fault current limit action can be set up with controlling the critical current value of the second superconducting element connected to the third coil in series. In SFCL, the first and the second coils have two magnetic paths and they are connected in parallel. Including the third coil, the two coils are twined in the same direction with E-I iron core. The YBCO thin film, whose critical temperature is 87 K, is used as the superconducting element. It is connected to the second and the third coils as well. In order to protect it from the heat released in the case of quench, the Au layer is additionally coated to a thickness of 200 nm. The critical current value is measured with 27 A. In order to plot a failure occurrence, Figure 3 shows the block diagram of the experimental circuit. It consists of 60 Hz AC voltage (Ein=160 V), line impedance (Li=1.82 mH, Ri=0.097 Ω), load resistance (RLoad=41.2 Ω), and SFCL. We put SW1 first, and during the period of failure, we operated SW2 to cause the circuit fault for 5 cycles. In so doing, we measured the induced voltage from the current flowing in three coils including lines, and the superconducting elements 1, and 2 through CT and PT, and analyzed them. Fault current limiting characteristics of SFCL with two magnetic paths due to the winding direction in the case that the fault occurred at 0°. (a) Subtractive polarity winding. (b) Additive polarity winding. Current limiting characteristics and voltage waveforms of parallel connected SFCL with two magnetic paths; its two coils are designed to have additive polarity winding (N1, N2). (a) Current waveforms of line (iSFCL and without iSFCL), and (b) each coil (i1, i2, i3). (c) Voltage waveforms of each coil (v1, v2, v3), and (d) Joule heat curve of each HTSC element  Through a short circuit simulation, we analyzed the operation of two superconducting elements and the fault current limiting characteristics according to the peak amplitude of the fault current and the coil directions before and after failure occurrence.  The peak current limiting operations were confirmed to be occurred contemporaneously with the moment that the current induced in the third coil exceeded the critical current of the second superconducting element.  On the other hand, in the case of the additive polarity winding connection, right after failure, only the first superconducting element caused quench. Furthermore, the current induced into the third coil did not exceed the critical current of the second superconducting element, which did not perform the peak current limiting operation of this SFCL.  We articulated that the additive polarity winding connection, from the viewpoint of the peak fault current limiting operation, was less effective than the subtractive polarity winding connection.  We made it freely control the high peak fault current, and, by increasing the inner magnetic flux of the iron core, prevent the iron core saturation.  The structure of the proposed SFCL has the two magnetic paths with the first coil, the second coil, and the third coil around one single E-I iron core. Fault Current Limiting Characteristics Current limiting characteristics and voltage waveforms of parallel connected SFCL with two magnetic paths; its two coils are designed to have subtractive polarity winding (N1, N2). (a) Current waveforms of line (iSFCL and without iSFCL), and (b) each coil (i1, i2, i3). (c) Voltage waveforms of each coil (v1, v2, v3), and (d) Joule heat curve of each HTSC element. Kongju National University Iron core & coilsValueUnit Total Mean Length (l 2 +l 3 )1,160mm Second Leg Length (l 1 )310mm Cross Sectional Area (S core )2,500mm 2 Turn Number of Coil 1 (N 1 )45Turns Turn Number of Coil 2 (N 2 )15Turns Turn Number of Coil 3 (N 3 )30Turns MaterialYBCO- Critical Temperature87K Critical Current27A Figure 4 shows the fault current limit characteristics of SFCL after the circuit fault occurs from the fault angle 0°. As seen in Figure 4(a), we could ascertain that when the first and second coils are tied in the subtractive polarity winding connection a resistance occurrence due to the quench of the first superconducting element immediately after a failure happens. This makes the induced voltage to the third coil not exceed the critical current value of the second superconducting element, and thus the operation of the peak current limit does not occur as depicted in Figure 4(b). Figure 5 shows the current limit characteristic of SFCL and the voltage shape of each coil. After the failure, a resistance occurs due to the creation of the quench from the first superconducting element. Then we found the operation of the peak current limit in the case that the induced voltage in the third coil exceeds the critical current of the second superconducting element after the resistance occurs. Like this, when the operation of the peak current limit is made, we found, the fault current limit is also in operation although it is less than that from the additive polarity winding connection. In considering Joule's heats of the superconducting elements, the first element shows higher than the second, and it is gradually increasing. Figure 6 shows the peak current limiting characteristics of SFCL having two magnetic paths with E-I iron core and the voltage shape induced in each coil, in case that the turns ratio between the first coil and the second coil is 0.33 and they are tied with the additive polarity winding connection. When a failure occurs at the fault angle, 0° the peak current limiting operation in the additive polarity winding connection was taken less effectively than that in the subtractive polarity winding connection. However the fault current limiting operation was improved.