Oscilloscope Fundamentals For Electrical Engineering and Physics Undergraduate Students.

Slides:



Advertisements
Similar presentations
Oscilloscope Fundamentals
Advertisements

Introduction to the Oscilloscope Professor Ahmadi ECE 002.
1 Cathode Ray Oscilloscope Introduction Look and play Read instructions Break into smaller parts Decide on a simple measurement Increase your level of.
Introduction 1st semester King Saud University
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
BASICS OF LAB SCOPES. Scope Essentials Digital Storage Oscilliscope (DSO) Voltmeter that captures voltage samples & displays them on a screen Voltage.
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
© 2009 Pearson Education, Upper Saddle River, NJ All Rights ReservedFloyd, Digital Fundamentals, 10 th ed Digital Fundamentals Tenth Edition Floyd.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
Introduction What is an oscilloscope?.
Fluke Oscilloscope 4 Isolated Channels 200 Mhz Bandwidth CAT III 1000 CAT IV 600 Rated 2.5 GS/s sample rate Connect-and-View™ IP-51 Rated.
The Oscilloscope: Basic Features & Functions  Source –Determines which signal is compared to the trigger settings.  Level –Determines where on the edge.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Electric Curcuits and Measurements Basic Electrical components and their functions Measurements of electrical circuits characteristics - Multimeter - Oscilloscope.
Oscilloscope Tutorial
 Popular instrument to show time, voltage both DC and AC. Shows Volts / Time.  Display waveforms. Spectrum scope shows volts to Frequency  Cathode (-ve.
The Oscilloscope shows voltage, Waveforms, & Phase shifts
Introduction to the Oscilloscope Professor Ahmadi ECE002 George Washington University.
Institute Of Applied Technology ATE 1012 Grade 10 Eng. Rose Hasan.
OBJECTIVES After studying Chapter 9, the reader will be able to:
CHAPTER 9 Oscilloscopes and Graphing Multimeters
Waveform 2.1 Basic Digital Waveforms 2 Measurement Paul Godin Updated October 2009.
Digital Fundamentals Floyd Chapter 1 Tenth Edition
General Engineering Polytechnic University Laboratory 9: Electrical Filters.
1 Cathode Ray Oscilloscope Introduction Look and play Look and play Read instructions Read instructions Break into smaller parts Break into smaller parts.
Oscilloscopes: 2 TYPES, ANALOG,DIGITIAL SEE APPENDIX i ANALOG: DIRECTLY APPLIES THE VOLTAGE BEING MEASURED TO AN ELECTRON BEAM WHICH MOVES UP, DOWN AND.
TDS 210 BASIC INSTRUCTIONS. Measure 1. Push the MEASURE button to access the automated measurement. 2. capabilities. There are five measurements available.
Laboratory Equipment 1 st semester King Saud University College of Applied studies and Community Service 1302CT By: Nour Alhariqi.
Project Work 1Lecture LECTURE 4 Repetitive signals Time varying signals e.g. RS-232 signals Oscilloscope.
WaveSurfer 3000 Oscilloscopes Public Release – July 1 st, 2014.
Oscilloscope Muhajir Ab. Rahim School of Mechatronic Engineering
© 2009 Pearson Education, Upper Saddle River, NJ All Rights ReservedFloyd, Digital Fundamentals, 10 th ed Digital Fundamentals with PLD Programming.
Scopes  An oscilloscope is a visual voltmeter.  An oscilloscope converts electrical signals into a visual image representing voltage changes over a.
LAB SCOPES. HIGH SPEED VOLTMETER n Replaces: Test LightTest Light Digital Voltmeter/Ammeter/OhmmeterDigital Voltmeter/Ammeter/Ohmmeter Frequency MeterFrequency.
Introduction to the Oscilloscope
Automotive Fuel and Emissions Control Systems, 2/e By James D. Halderman and Jim Linder © 2009 Pearson Higher Education, Inc. Pearson Prentice Hall -
Laboratory 9: Electronic Filters. Overview Objectives Background Materials Procedure Report / Presentation Closing.
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
Advanced Engine Performance Diagnosis, 4/e By James D. Halderman © 2009 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ.
The Probe: Measurement Accuracy Begins at the Tip  Attenuation –The ratio of the probe’s input signal amplitude to the output signal amplitude..  Bandwidth.
Laboratory 10: Electronic Filters. Overview  Objectives  Background  Materials  Procedure  Report / Presentation  Closing.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
Floyd, Digital Fundamentals, 10 th ed Digital Fundamentals Tenth Edition Floyd © 2008 Pearson Education Chapter 1.
The University of Texas at Arlington Electrical Engineering Department
Lecture 5: DMM & Oscilloscope 1. DMM can be used to measure: DC & AC voltages – current - resistance - BJT (β test) - diode test - short circuit test,
1 Logic State Analyzers A tool for observing logic states of multiple signals at once, in time A logic probe can show only one bit at a time. Extremely.
Scope TEKTRONIX TDS. Frontal View Menu and Control Buttons Multipurpose knob.
BASIC INSTRUMENTS - oscilloscopes
Advanced Engine Performance Diagnosis, Fourth Edition James D. Halderman Copyright ©2009 by Pearson Higher Education, Inc. Upper Saddle River, New Jersey.
Automotive Electricity and Electronics, 2/e By James D Halderman © 2009 Pearson Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ OBJECTIVES.
Common Stages of Digital Debug Discover Your probes will affect your ability to accurately visualize your signal. You need the right probes to maintain.
By. Jadhav Avinash J Roll no - 2K13E11. Reference: Hewlett Packard Agilent Technology Wikipedia GwINSTEK.
Residential Cabling Technologies Copyright © 2005 Heathkit Company, Inc. All Rights Reserved Electrical Measurements.
Cathode Ray Oscilloscope Introduction
Cathode Ray Oscilloscope Introduction
EKT124 Digital Electronics 1 Introduction to Digital Electronics
(5) DMM & Oscilloscope.
Oscilloscopes and Graphing Multimeters
Introduction What is an oscilloscope?.
Oscilloscope and its applications
Cathode Ray Oscilloscope Introduction
Oscilloscopes Fundamentals
Electronic Measurements 2 (COM 9214) Lecture 8: Oscilloscope Presented by: Ahmed Elnakib*, PhD Assistant Professor, Mansoura University, Egypt 1 Courtesy:
FIGURE 9-1 (a) On an analog scope, the voltage measured at the throttle position signal wire is displayed on a horizontal line at about 0.5 volt. (b) As.
Oscilloscopes HP 54600B Digital Oscilloscope Alex Jones COE 0501.
Digital Fundamentals Floyd Chapter 1 Tenth Edition
FIGURE 9-1a On an analog scope, the voltage measured at the throttle position signal wire is displayed on a horizontal line at about 0.5 volt.
Oscilloscopes and Graphing Multimeters
Automotive Technology Principles, Diagnosis, and Service
Introduction to the Oscilloscope Engr. Annalyn soria Lecturer.
Presentation transcript:

Oscilloscope Fundamentals For Electrical Engineering and Physics Undergraduate Students

Agenda  What is an oscilloscope?  Probing basics (low-frequency model)  Making voltage and timing measurements  Properly scaling waveforms on-screen  Understanding oscilloscope triggering  Oscilloscope theory of operation and performance specifications  Probing revisited (dynamic/AC model and affects of loading)  Using the DSOXEDK Lab Guide and Tutorial  Additional technical resources

What is an oscilloscope?  Oscilloscopes convert electrical input signals into a visible trace on a screen - i.e. they convert electricity into light.  Oscilloscopes dynamically graph time-varying electrical signals in two dimensions (typically voltage vs. time).  Oscilloscopes are used by engineers and technicians to test, verify, and debug electronic designs.  Oscilloscopes will be the primary instrument that you will use in your EE/Physics labs to test assigned experiments. os·cil·lo·scope (ə-sĭl'ə-skōp')

Terms of Endearment (what they are called) Scope – Most commonly used terminology DSO – Digital Storage Oscilloscope Digital Scope Digitizing Scope Analog Scope – Older technology oscilloscope, but still around today. CRO – Cathode Ray Oscilloscope (pronounced “crow”). Even though most scopes no longer utilize cathode ray tubes to display waveforms, Aussies and Kiwis still affectionately refer to them as their CROs. O-Scope MSO – Mixed Signal Oscilloscope (includes logic analyzer channels of acquisition)

Probing Basics  Probes are used to transfer the signal from the device-under- test to the oscilloscope’s BNC inputs.  There are many different kinds of probes used for different and special purposes (high frequency applications, high voltage applications, current, etc.).  The most common type of probe used is called a “Passive 10:1 Voltage Divider Probe”.

Passive 10:1 Voltage Divider Probe Passive: Includes no active elements such as transistors or amplifiers. 10-to-1: Reduces the amplitude of the signal delivered to the scope’s BNC input by a factor of 10. Also increases input impedance by 10X. Note: All measurements must be performed relative to ground! Passive 10:1 Probe Model

Low-frequency/DC Model Low-frequency/DC Model: Simplifies to a 9-MΩ resistor in series with the scope’s 1-MΩ input termination. Probe Attenuation Factor: Some scopes such as Agilent’s 3000 X-Series automatically detect 10:1 probes and adjust all vertical settings and voltage measurements relative to the probe tip. Some scopes such as Agilent’s 2000 X-Series require manual entry of a 10:1 probe attenuation factor. Dynamic/AC Model: Covered later and during Lab #5. Passive 10:1 Probe Model

Understanding the Scope’s Display  Waveform display area shown with grid lines (or divisions).  Vertical spacing of grid lines relative to Volts/division setting.  Horizontal spacing of grid lines relative to sec/division setting. Volts Time Vertical = 1 V/divHorizontal = 1 µs/div 1 Div

Making Measurements – by visual estimation  Period (T) = 4 divisions x 1 µs/div = 4 µs, Freq = 1/T = 250 kHz.  V p-p = 6 divisions x 1 V/div = 6 V p-p  V max = +4 divisions x 1 V/div = +4 V, V min = ? V p-p Period Vertical = 1 V/divHorizontal = 1 µs/div V max Ground level (0.0 V) indicator The most common measurement technique

Making Measurements – using cursors  Manually position X & Y cursors to desired measurement points.  Scope automatically multiplies by the vertical and horizontal scaling factors to provide absolute and delta measurements. X1 Cursor X2 Cursor Y1 Cursor Y2 Cursor Δ Readout Absolute V & T Readout Cursor Controls

Making Measurements – using the scope’s automatic parametric measurements  Select up to 4 automatic parametric measurements with a continuously updated readout. Readout

Primary Oscilloscope Setup Controls Horizontal Scaling (s/div) Horizontal Position Vertical Position Vertical Scaling (V/div) Input BNCs Trigger Level Agilent’s InfiniiVision 2000 & 3000 X-Series Oscilloscope

Properly Scaling the Waveform  Adjust V/div knob until waveform fills most of the screen vertically.  Adjust vertical Position knob until waveform is centered vertically.  Adjust s/div knob until just a few cycles are displayed horizontally.  Adjust Trigger Level knob until level set near middle of waveform vertically. - Too many cycles displayed. - Amplitude scaled too low. Initial Setup Condition (example) Optimum Setup Condition Trigger Level Setting up the scope’s waveform scaling is an iterative process of making front panel adjustments until the desired “picture” is displayed on-screen.

Understanding Oscilloscope Triggering  Think of oscilloscope “triggering” as “synchronized picture taking”.  One waveform “picture” consists of many consecutive digitized samples.  “Picture Taking” must be synchronized to a unique point on the waveform that repeats.  Most common oscilloscope triggering is based on synchronizing acquisitions (picture taking) on a rising or falling edge of a signal at a specific voltage level. Triggering is often the least understood function of a scope, but is one of the most important capabilities that you should understand. A photo finish horse race is analogous to oscilloscope triggering

Triggering Examples  Default trigger location (time zero) on DSOs = center-screen (horizontally)  Only trigger location on older analog scopes = left side of screen Trigger Point Untriggered (unsynchronized picture taking) Trigger = Rising 0.0 V Trigger = Falling +2.0 V Trigger level set above waveform Positive TimeNegative Time

Advanced Oscilloscope Triggering  Most of your undergraduate lab experiments will be based on using standard “edge” triggering  Triggering on more complex signals requires advanced triggering options. . Example: Triggering on an I 2 C serial bus

Oscilloscope Theory of Operation DSO Block Diagram Yellow = Channel-specific blocks Blue = System blocks (supports all channels)

Oscilloscope Performance Specifications  All oscilloscopes exhibit a low-pass frequency response.  The frequency where an input sine wave is attenuated by 3 dB defines the scope’s bandwidth.  -3 dB equates to ~ -30% amplitude error (-3 dB = 20 Log ). Oscilloscope “Gaussian” Frequency Response “Bandwidth” is the most important oscilloscope specification

Selecting the Right Bandwidth  Required BW for analog applications: ≥ 3X highest sine wave frequency.  Required BW for digital applications: ≥ 5X highest digital clock rate.  More accurate BW determination based on signal edge speeds (refer to “Bandwidth” application note listed at end of presentation) Response using a 100-MHz BW scope Input = 100-MHz Digital Clock Response using a 500-MHz BW scope

Other Important Oscilloscope Specifications  Sample Rate (in samples/sec) – Should be ≥ 4X BW  Memory Depth – Determines the longest waveforms that can be captured while still sampling at the scope’s maximum sample rate.  Number of Channels – Typically 2 or 4 channels. MSO models add 8 to 32 channels of digital acquisition with 1-bit resolution (high or low).  Waveform Update Rate – Faster update rates enhance probability of capturing infrequently occurring circuit problems.  Display Quality – Size, resolution, number of levels of intensity gradation.  Advanced Triggering Modes – Time-qualified pulse widths, Pattern, Video, Serial, Pulse Violation (edge speed, Setup/Hold time, Runt), etc.

Probing Revisited - Dynamic/AC Probe Model  C scope and C cable are inherent/parasitic capacitances (not intentionally designed-in)  C tip and C comp are intentionally designed-in to compensate for C scope and C cable.  With properly adjusted probe compensation, the dynamic/AC attenuation due to frequency- dependant capacitive reactances should match the designed-in resistive voltage-divider attenuation (10:1). Passive 10:1 Probe Model Where C parallel is the parallel combination of C comp + C cable + C scope

Compensating the Probes  Connect Channel-1 and Channel-2 probes to the “Probe Comp” terminal (same as Demo2).  Adjust V/div and s/div knobs to display both waveforms on-screen.  Using a small flat-blade screw driver, adjust the variable probe compensation capacitor (C comp ) on both probes for a flat (square) response. Proper CompensationChannel-1 (yellow) = Over compensated Channel-2 (green) = Under compensated

Probe Loading  The probe and scope input model can be simplified down to a single resistor and capacitor.  Any instrument (not just scopes) connected to a circuit becomes a part of the circuit under test and will affect measured results… especially at higher frequencies.  “Loading” implies the negative affects that the scope/probe may have on the circuit’s performance. C Load Probe + Scope Loading Model R Load

Assignment 1.Assuming C scope = 15pF, C cable = 100pF and C tip = 15pF, compute C comp if properly adjusted. C comp = ______ 2.Using the computed value of C comp, compute C Load. C Load = ______ 3.Using the computed value of C Load, compute the capacitive reactance of C Load at 500 MHz. X C-Load = ______ C Load = ?

Using the Oscilloscope Lab Guide and Tutorial Homework – Read the following sections before your 1 st oscilloscope lab session: Section 1 – Getting Started Oscilloscope Probing Getting Acquainted with the Front Panel Appendix A – Oscilloscope Block Diagram and Theory of Operation Appendix B – Oscilloscope Bandwidth Tutorial Hands-on Oscilloscope Labs Section 2 – Basic Oscilloscope and WaveGen Measurement Labs (6 individual labs) Section 3 – Advanced Oscilloscope Measurement Labs (9 optional labs that your professor may assign) Oscilloscope Lab Guide and Tutorial

Hints on how to follow lab guide instructions Bold words in brackets, such as [Help], refers to a front panel key. “Softkeys” refer to the 6 keys/buttons below the scope’s display. The function of these keys change depending upon the selected menu. A softkey labeled with the curled green arrow ( ) indicates that the general-purpose “Entry” knob controls that selection or variable. Softkeys Softkey Labels Entry Knob

Accessing the Built-in Training Signals 1.Connect one probe between the scope’s channel-1 input BNC and the terminal labeled “Demo1”. 2.Connect another probe between the scope’s channel-2 input BNC and the terminal labeled “Demo2”. 3.Connect both probe’s ground clips to the center ground terminal. 4.Press [Help]; then press the Training Signals softkey. Connecting to the training signals test terminals using 10:1 passive probes Most of the oscilloscope labs are built around using a variety of training signals that are built into the Agilent 2000 or 3000 X-Series scopes if licensed with the DSOXEDK Educator’s Training Kit option.

Additional Technical Resources Available from Agilent Technologies Page 28 Insert pub # in place of “xxxx-xxxx”

Page 29 Questions and Answers