IHE NA Webinar Series 2008 What IHE Delivers 1 NM Image IHE North America Webinar Series 2008 Chris Lindop IHE Radiology GE Healthcare
IHE NA Webinar Series NM Image The Problem Product support is inconsistent DICOM NM object coding techniques very NM full-body display needs misunderstood NM cardiac display needs misunderstood Clinical Analysis Applications results distribution unsupported Poor communiction during product purchase NM Users are not adept at getting these requirements accurately included in RFPs Vendors (especially of general purpose systems) are not adept at accurately representing their support for such features
IHE NA Webinar Series General NM Viewing Suboptimal NMPACS
IHE NA Webinar Series General NM Viewing Suboptimal NMPACS
IHE NA Webinar Series General NM Viewing Suboptimal Click and move mouse down to adjust window level, right to adjust window center
IHE NA Webinar Series Cardiac Viewing Suboptimal If sent as Short axis Images not displayed in a useful format. If sent as screen snapshots (ie, static Secondary Capture) Can’t separately adjust stress and rest images Can’t view gated cine
IHE NA Webinar Series NM Image Value Proposition Use general Radiology Infrastructure to: Satisfy Basic NM Data Needs Access to NM Images Access to usable presentations of NM Images Access to Clinical Processing Results Satisfy NM Workflow Needs Map Cardiac and Multi-phase Studies to SWF Improved Query
IHE NA Webinar Series NM Image Abstract / Scope Content Profile for users to request For vendors to claim No New Actors or Transactions Additional requirements on existing actors and transactions Total of 4 options
IHE NA Webinar Series NM Image Standards Used DICOM NM Image Object DICOM Multiframe Secondary Capture Dynamic Results Static Results DICOM Secondary Capture Static Results ACC NM Cardiac Display format
IHE NA Webinar Series NM Image Transaction Diagram
IHE NA Webinar Series NM Image Actors Acquisition Modalities Create NM objects as specified (Series, attribute & vector handling) Include clinical coding in Cardiac studies Image Manager/Archives Store/Retrieve NM & Secondary Capture (SC & MFSC) Objects Support Query on Study Description Evidence Creators Create NM objects as specified (Series, attribute & vector handling) Include process-specific coding in Cardiac studies Use cardiac codes during processing Image Displays Display NM and Secondary Capture (SC & MFSC) Images Support specified display capabilities Handles specific NM DICOM attributes
IHE NA Webinar Series Result Screen Export Option
IHE NA Webinar Series Result Screen Export Option: Evidence Creators Render Dynamic Result Screens Capture Dynamic Results using the following DICOM Objects: Multi-Frame Secondary Capture –Grayscale Byte –True Color Render Static Result Screens Capture the Static Results using either single frame Multi-frame (preferred) Must generate appropriate Secondary Capture objects from any Result Screens rendered.
IHE NA Webinar Series Image Display Display NM and Result-Screen Images Support specified NM essential display capabilities Additional attribute handling e.g. Patient State, Image Orientation, Detector Sequence, View Code Sequence
IHE NA Webinar Series Options: Image Displays General NM Option Whole body display Cardiac NM Option ACC NM Cardiac display Displays must support at least one of these options!
IHE NA Webinar Series Handle multi-frame / multi-vector images Multiple simultaneous cines Grayscale and color result screens Dynamic and static result screens Original resolution and scaled Separate adjustment of upper and lower window levels Apply local color tables to grayscale screens Add new local color tables to system Change intensity of grayscale result screens Display Series Description tag Image Display
IHE NA Webinar Series Image Display Scale “intelligently” to avoid presenting postage-stamp size NM images Allow user to select different vectors/framesets of complex multi- frame images Allow user to separately adjust intensity for different framesets (eg, phases) in the same “image”
IHE NA Webinar Series Display Formats Grid display Frames from one image set A 32 … ………………… …………………… …………………A9A9 A8A8 A7A7 A6A6 A5A5 A4A4 A3A3 A2A2 A1A1 C1C1 C1C1 B2B2 B1B1 A2A2 A1A1 Fit display Frames from multiple image sets
IHE NA Webinar Series ACC NM Cardiac Display Generate long axis from short axis images Display of 2 image sets (Stress and Rest) Use patient state tags to set display order Follow ACC guidelines for display Controls for adjusting stress and rest Image alignment Window upper and lower levels.
IHE NA Webinar Series ACC NM Display Example Short axis Horizontal Long Vertical Long
IHE NA Webinar Series ACC NM Display Example Short Horizontal Vertical Stress Rest Stress Rest Stress Rest Stress Rest
IHE NA Webinar Series MPR Option: Image Displays Adds Image Display requirements to support Review of SPECT NM Images with Multi-planar reconstruction (MPR) Transaxial Sagittal Coronal
IHE NA Webinar Series