Active Pixel Sensors in Nuclear Medicine Imaging RJ Ott, N Evans, P Evans, J Osmond, A Clark, R Turchetta Physics Department Institute of Cancer Research.

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

Radiation damage in silicon sensors
Area Detectors Like film can detect position Like scintillation detector can measure intensity With modern computers can assign hkl from unaligned crystal.
HgCdTe Avalanche Photodiode Arrays for Wavefront Sensing and Interferometry Applications Ian Baker* and Gert Finger** *SELEX Sensors and Airborne Systems.
Advanced GAmma Tracking Array
Chapter 8 Planar Scintigaraphy
CHARGE COUPLING TRUE CDS PIXEL PROCESSING True CDS CMOS pixel noise data 2.8 e- CMOS photon transfer.
Astronomical Detectors
Microelectronics Design Group RAL - Microelectronics Open Day 28 th June 2005 Intelligent Digital Sensors Jamie Crooks.
Mid-IR photon counting array using HgCdTe APDs and the Medipix2 ROIC
Photon Counting Sensors for Future Missions
9th IWoRiD: Erlangen,July 2007, John Vallerga High resolution UV, Alpha and Neutron Imaging with the Timepix CMOS readout J. Vallerga, J. McPhate, A. Tremsin.
Charge-Coupled Device (CCD)
Overview of Scientific Imaging using CCD Arrays Jaal Ghandhi Mechanical Engineering Univ. of Wisconsin-Madison.
8/18/2015G.A. Fornaro Characterization of diffractive optical elements for improving the performance of an endoscopic TOF- PET detector head Student: G.
NA62 Gigatracker Working Group Meeting 2 February 2010 Massimiliano Fiorini CERN.
SPiDeR  First beam test results of the FORTIS sensor FORTIS 4T MAPS Deep PWell Testbeam results CHERWELL Summary J.J. Velthuis.
CMOS and Microfluidic Hybrid System on Chip for Molecule Detection Bowei Zhang, Qiuchen Yuan, Zhenyu Li, Mona E. Zaghloul, IEEE Fellow Dept. of Electrical.
CMOS Image Sensor Design. M. Wäny Nov EMVA Standard 1288 Standard for Measurement and Presentation of Specifications for Machine Vision Sensors and.
Measurement and Simulation of the Variation in Proton-Induced Energy Deposition in Large Silicon Diode Arrays Christina L. Howe 1, Robert A. Weller 1,
CCD Detectors CCD=“charge coupled device” Readout method:
Fundamental Limits of Positron Emission Tomography
Salvatore Tudisco The new generation of SPAD Single Photon Avalanche Diodes arrays I Workshop on Photon Detection - Perugia 2007 LNS LNS.
Active Pixel Sensors for Direct Detection of Soft X-rays Andrew Blue* a, R. Bates a, A. Clark c, S. Dhesi b, D. Maneuski a, J. Marchal b, P. Steadman b,
“Fingerprint Recognition based on Silicon Chips”.
12/09/2011Position Sensitive Detectors 91 &. 12/09/2011Position Sensitive Detectors 92 Tracking of Moving Fiducial Markers during Radiotherapy using a.
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
The Multidimensional Integrated Intelligent Imaging Project (M-I 3 ) Phil Evans on Behalf of M-I 3 consortium.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
MACHINE VISION Machine Vision System Components ENT 273 Ms. HEMA C.R. Lecture 1.
DynAMITe: a Wafer Scale Sensor for Biomedical Applications M. Esposito 1, T. Anaxagoras 2, A. Fant 2, K. Wells 1, A. Kostantinidis 3, J. Osmond 4, P. Evans.
Astronomical Institute University of Bern 31th IADC Meeting, April , 2013, ESOC, Darmstadt, Germany Improved Space Object Observation Techniques.
Characterisation of Active Pixel Sensors
Development of CCDs for the SXI We have developed 2 different types of CCDs for the SXI in parallel.. *Advantage =>They are successfully employed for current.
Development of a Gamma-Ray Beam Profile Monitor for the High-Intensity Gamma-Ray Source Thomas Regier, Department of Physics and Engineering Physics University.
Pixellated CZT high-energy X-ray instrument
1 Miniradmeter: a miniature detector for gamma rays (and neutrons?) G.Alimonti, P.Finocchiaro A miniature detector for gamma rays (and neutrons?) G.Alimonti,
1 Wojciech Dulinski Pixel 2000, Genova, Italy Pixel Sensors for Single Photon Detection Contents - Idea and basic architecture.
Snowmass, August, 2005P. Colas - InGrid1 M. Chefdeville a, P. Colas b, Y. Giomataris b, H. van der Graaf a, E.H.M.Heijne c, S.van der Putten a, C. Salm.
Radiation hardness of Monolithic Active Pixel Sensors (MAPS)
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Gossip/GridPix – guidelines, facts, and questions for review Version 1: Norbert Version 2: Tatsuo Version 3: Werner.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
W. Kucewicz a, A. A.Bulgheroni b, M. Caccia b, P. Grabiec c, J. Marczewski c, H.Niemiec a a AGH-Univ. of Science and Technology, Al. Mickiewicza 30,
Digitization in EMC simulation Dmytro Melnychuk, Soltan Institute for Nuclear Studies, Warsaw, Poland.
Active Pixel Sensors in Medical and Biologi The application of Large Area Active Pixel Sensor (LAS) to high resolution Nuclear Medicine imaging Bob Ott.
Neutron Imaging for the Hydrogen Economy Neutrons see material differently than x-rays The fine details of the water in this Asiatic Lily are clear to.
3D-ASICS for X-ray Science
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
Monolithic and Vertically Integrated Pixel Detectors, CERN, 25 th November 2008 CMOS Monolithic Active Pixel Sensors R. Turchetta CMOS Sensor Design Group.
18 Sep 2008Paul Dauncey 1 DECAL: Motivation Hence, number of charged particles is an intrinsically better measure than the energy deposited Clearest with.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Analysis of denoising filters for photo response non uniformity noise extraction in source camera identification Irene Amerini, Roberto Caldelli, Vito.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Digital Imaging Instead of Radiography.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
LSST CCD Chip Calibration Tiarra Stout. LSST Large Synoptic Survey Telescope Camera – 1.6 m by 3 m. 3.2 billion pixels kg (~6173 lbs) 10 square.
Comparison of a CCD and the Vanilla CMOS APS for Soft X-ray Diffraction Graeme Stewart a, R. Bates a, A. Blue a, A. Clark c, S. Dhesi b, D. Maneuski a,
Date of download: 6/23/2016 Copyright © 2016 SPIE. All rights reserved. Pixel layouts for (a) a standard 3-T APS containing reset (R), row select (RS)
Hybrid Detector(s) for Complete Gamma Ray Spectroscopy S. S. Bhattacharjee, R Raut, S S Ghugre, A K Sinha UGC-DAE Consortium For Scientific Research, Kolkata.
CMOS APS for X-ray, Photon and Astronomy based applications Andy Blue.
Electronics Lecture 5 By Dr. Mona Elneklawi.
Fully Depleted Low Power CMOS Detectors
Image quality and Performance Characteristics
Charge Transfer Efficiency of Charge Coupled Device
Image quality and Performance Characteristics
X-ray detectors and diagnostics for HED instrument
Application of Nuclear Physics
Yasuhiro Sugimoto KEK 17 R&D status of FPCCD VTX Yasuhiro Sugimoto KEK 17
Active Pixel Sensors for Electron Microscopy
Presentation transcript:

Active Pixel Sensors in Nuclear Medicine Imaging RJ Ott, N Evans, P Evans, J Osmond, A Clark, R Turchetta Physics Department Institute of Cancer Research and Royal Marsden Hospital, Brunel University and Rutherford Appleton Laboratories

What is Nuclear Medicine The use of radioactive tracers to imaging the function of living tissues Whole body imaging performed using gamma cameras and PET cameras with spatial resolutions of >5mm High resolution (<1mm) imaging desirable for studying the detail of tracer uptake

What is an active pixel sensor (APS) A silicon wafer based sensor similar to a CCD but with the potential for intelligent processing in each pixel APSs are based on mainstream CMOS technology with low-power, high-speed, cost-effectiveness, flexibility and high levels of on-chip integration. The sensors used here were developed and funded under the MI-3 research consortium

The MI-3 research consortium MI-3 stands for Multidimensional Integrated Intelligent Imaging MI-3 is a four-year £4.5m Basic Technology project funded by RCUK to advance the capabilities and application of APSs for a raft of scientific and technological endeavours

Parameters of APS used here 1-100~2525 x 25520Vanilla >3700>10040 x 4064 x 72OPIC x 25525Startracker Frame rates (fps) System noise (e) Pixel size (μm) Number of pixels per side

High-resolution gamma camera wish-list Pixel sizes of 100 microns or more Coupled to thin inorganic phosphor such as CsI(Tl) to allow detection of 140keV photons Low noise (few electrons) needed >100 cm 2 sensitive area Kcps photon counting capacity On-chip pulse and cluster analysis for signal selection and noise reduction

High-resolution gamma camera (what we have so far) Pixel sizes of microns Coupled to 2mm thick CsI(Tl) phosphor segmented into 400 micron elements electrons noise ~2 cm 2 sensitive area A few 10s of cps photon counting capacity Off chip data analysis

The Startracker imaging setup APS coupled to pixelated CsI(Tl) phosphor via optical fibre stud

Intrinsic spatial resolution measured with Startracker Spatial resolution ~80 microns FWHM

Startracker system resolution measurements 5mm wide slot System resolution is about 450 microns

Conclusions from Startracker studies Pixel sizes are smaller than needed reducing signal to noise by splitting signal Overall background is too high requiring noise removal Background is dominated by ‘fixed pattern noise’ which can be ‘subtracted. Thermal noise reduction makes only a small contribution for this sensor

Noise studies with OPIC Single frame illumination with laser pointer Template produced from pixel variance analysis of multiple frames Fixed pattern noise Statistical noise

Conclusions from noise studies with OPIC Pixel noise is dominated by 'fixed pattern noise' By studying the variance of pixel noise in multiple frames it is possible to differentiate between statistical noise and fixed pattern noise. A simple method of noise 'subtraction' can be used to remove fixed pattern noise from pixels

Noise images taken with Vanilla Total noise fixed pattern statistical noise noise Data from dark frame images

Images taken with Vanilla 2mm wide illuminated hole horizontal profile Multi-frame acquisitions after fixed pattern noise removal

Images taken with Vanilla 5mm wide slot 1mm holes on 2mm centres Multi-frame acquisitions after fixed pattern noise removal

Images taken with Vanilla using thin non-segmented CsI(Tl) 6mm wide hole3mm holes 2mm wide hole Multi-frame acquisitions after fixed pattern noise removal

So where are we at? Tc-99m gamma rays produce ~7000 optical photons in CsI(Tl) Number of optical photons reaching sensor is probably ~ Area of sensor sensing each event ~400 μm (size of phosphor element) With 40 μm pixels the signal is spread over 100 pixels (25 micron pixels are worse) Hence even for 100% QE the signal per pixel will often be less than the noise Use of thin, non segmented phosphor might help but the detection efficiency is much lower Larger area sensor with larger pixels (>100 μm) and lower noise would work

Conclusions 1.APS Devices with the right parameters could make a contribution to high resolution Nuclear Medicine Imaging 2. Noise levels are still a problem for this application 3.Fixed pattern noise dominates over thermal noise making noise removal easier 4. On-chip intelligence to filter out noise would be useful 5. Larger area devices with larger pixels essential.

Future Large area sensor is now being released by RAL Sensitive area of 56mm x 56mm in area with 1400 x 1400 pixels Pixel sizes 40μm Pixel noise levels ~**e

Acknowledgements We would like to thank the electronics group at RAL for the design and testing of these sensors and support of the project. the MI-3 consortium for scientific discussion and input RCUK for funding the work through the Basic Technology research grant GR/S85733/01