Intravascular Foreign Body Retrieval System Nathan Luibrand, Nicholas Luibrand, Lukas Richards, and Elise Adcock-Hinojosa Advised by Dr. Michael Barnett.

Slides:



Advertisements
Similar presentations
Venous Cannulation Learning Resource
Advertisements

ARTreat Vision. Atherosclerosis The problem Definition: “Atherosclerosis is a vascular disease associated with the accumulation of lipids leading to the.
Indicated for Arterial and Venous Embolizations in the Peripheral Vasculature April, 2004.
Long lost rubber ball found in dog’s stomach. Background… A 13 year old dog had a rubber ball in his stomach for 11 years! The dog drank a barium solution.
EDGE™ Centering Magnet Device P08028 By: Aaron Burger.
EDGE™ A P D C Copyright © 2004 Dr. Edward Hensel P.E. and P.H. Stiebitz. All rights reserved. Technical Data Package & Team Notebook …what is it anyway?
Robotic Needle End Effector for Integration with CT Scan Team Members: David Sun Xuan Truong Chris Willingham Advisor: Dr. Bradford Wood.
 The vectorcardiograph (VCG) examines the ECG potentials generated along the three-dimensional axes of the body; that is, the x, y, and z planes.  The.
Develop tracheoesophageal voice prosthesis insertion kit: To be used prior to insertion of Blom-Singer voice prosthesis Create kit specific to tracheoesophageal.
SDC PUBLICATIONS © 2012 Chapter 16 Assembly Modeling Learning Objectives:  Understand the Assembly Modeling Methodology  Create Parts in the Assembly.
EF 101 Analysis & Skills Module 1.2 Engineering Graphics - Introduction and Sketching Basics.
Digital Teaching and Learning Michael Constantino.
Project Definition The aim of this project was to design a steerable catheter, which would enable easier access to specific blood vessels. The design would.
CATCH : Mechanical Thrombus Retriever
Literature Review and Parts of Proposal
MIND DYNAMICS 1. 2 INTRODUCTION / BACKGROUND BRAIN FLOWER is a unique organization which helps their participants to realize their mental potential,
An Opening in the Abdomen An Opening in the Market: Hernia Tensiometer GROUP 2: Martha Ingram Megan Johnston Chelsea Samson.
Intravascular Foreign Body Retrieval System Nathan Luibrand, Nicholas Luibrand, Lukas Richards, and Elise Adcock-Hinojosa Advised by Dr. Michael Barnett.
Angiography and Interventional Radiography Chapter 20.
Product Recall 1 What: Cook CloverSnare 4-Loop Vascular Retrieval Snare Recall Date: July 17, 2014 [1] Why: The snare tip may break during use and separate.
Intravascular Foreign Body Retrieval System Nathan Luibrand, Nicholas Luibrand, Lukas Richards, and Elise Adcock-Hinojosa Advised by Dr. Michael Barnett.
Angiography and Interventional Radiography Chapter 17.
Product Development.
Design of a Steerable Catheter Steeratheter
Pulmonary Embolism Extraction Catheter Development Trip Cothren Lauren Nichols Dustin Temple Advised by: Dr. Michael Barnett, VUMC Cardiology.
GNET BRAINSTORMING. GNET INTRODUCTION.
Patent Ductus and Vascular Occlusion Devices Michelle Carlsen Elaine Isom Brad Klosterman Ornob Roy Advisor: Dr. Thomas Doyle.
Pulmonary Embolism Extraction Catheter Development
Renal Intervention by the Radial Approach Josef Ludwig, Erlangen Angiosoft.NET.
Minimally Invasive Delivery System for Bone Graft Materials Lauren Burdock (BME) Jon Witten (BME) Frank Zhao (BME) Sponsor: Michael Voor Ph.D. University.
Minimally Invasive Delivery System for Bone Graft Materials Lauren Burdock (BME) Jon Witten (BME) Frank Zhao (BME)
Presents the new 3-Dimensional Open Loop Designed AndraSnare& AndraSnare Micro.
Date of download: 6/2/2016 Copyright © The American College of Cardiology. All rights reserved. From: Retrograde Techniques and the Impact of Operator.
Occlusion Device for Patent Ductus Arteriosus Christina Mathieson & Trung Nguyen Advisor: Dr. Tom Doyle BME 273 – Senior Design Project.
The Robotic ENT Microsurgery System (REMS): Calibration and IRB Study, and Tool Holder Design Checkpoint Presentation CIS II Spring 2015: Brian Gu, Barbara.
Determine method of rapid prototyping or plastic extrusion to create prototype of true-to-scale catheter Determine optimal slot size without affecting.
Open cervical approach for carotid artery stenting
Welcome to the IHCSScience Fair Parent Night December 1, 2016.
Wire Externalization, Snaring and Removal
Successful Removal of Entrapped and Kinked Catheter during Right Transradial Cardiac Catheterization by Snaring and Unwinding the Catheter via Femoral.
Self-Contained Endoscopic Video Camera
Chapter 2 Design Tools.
Ravi K. Ghanta, MD, John A. Kern, MD 
Minimally Invasive Delivery System for Bone Graft Materials
CRT 2012 Primer for Endovascular Interventions
Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones  Toshio Takayama, MD, PhD, Patrick J. Phelan,
Pupil Expanders – Is a Hexagon better than Square?
Patent Ductus Arteriosus Occlusion Device
Robert J. Lederman et al. JIMG 2014;7:
Endovascular management of juxtarenal aneurysms with fenestrated endovascular grafting  Roy K Greenberg, MD, Stephan Haulon, MD, Sean P Lyden, MD, Sunita.
Robotic Needle End Arm Effector for Integration With CT Scan
Robotic Needle End Arm Effector for Integration With CT Scan
Ravi K. Ghanta, MD, John A. Kern, MD 
Intraprocedural imaging: Thoracic aortography techniques, intravascular ultrasound, and special equipment  Rodney A. White, MD, Carlos E. Donayre, MD,
Three new techniques for creation of a steerable sheath, a 4F snare, and bidirectional sheath inversion using existing endovascular materials  Alexandros.
Mark R. Nehler, MD, W. Andrew Lawrence, MD, Thomas A
Celia V. Riga, MRCS, Nicholas J. W. Cheshire, MD, Mohamad S
Endovascular Retrieval of Fragmented Central Venous Access Device Catheters: A Management Protocol Based on Catheter Location  S.-F. Ko, C.-K. Sun, C.-T.
Endovascular repair of thoracoabdominal aortic aneurysm using the off-the-shelf multibranched t-Branch stent graft  Bernardo C. Mendes, MD, Gustavo S.
What is Interventional Radiology?
Failure modes of thoracic endografts: Prevention and management
Minimally Invasive Delivery System for Bone Graft Materials
Fracture of the phaco tip during Micro Incision Cataract Surgery
Technical aspects of repair of juxtarenal abdominal aortic aneurysms using the Zenith fenestrated endovascular stent graft  Gustavo S. Oderich, MD, Mateus.
Mark R. Nehler, MD, W. Andrew Lawrence, MD, Thomas A
Journal of Vascular Surgery
Transbrachial branch cannulation during Zenith fenestrated endovascular aortic aneurysm repair using a robotically guided body-floss technique  Sukgu.
Paul J. Foley, MD, Derek P. Nathan, MD, Grace J. Wang, MD, Edward Y
Transbrachial branch cannulation during Zenith fenestrated endovascular aortic aneurysm repair using a robotically guided body-floss technique  Sukgu.
TURNING IDEAS INTO REALITY: ENGINEERING A BETTER WORLD
Presentation transcript:

Intravascular Foreign Body Retrieval System Nathan Luibrand, Nicholas Luibrand, Lukas Richards, and Elise Adcock-Hinojosa Advised by Dr. Michael Barnett

Problem Statement There is only one tool commonly used today, the En Snare. There is only one tool commonly used today, the En Snare. Very limited maneuverability. Very limited maneuverability.

Background Over 70,000 foreign body retrieval procedures are performed per year. Over 70,000 foreign body retrieval procedures are performed per year. Items retrieved from the vascular system include wire and catheter fragments and stents. Items retrieved from the vascular system include wire and catheter fragments and stents. The En Snare Device A system of 3 interlocked loops of wire which when pulled into the catheter cause the loops to close and catch the targeted foreign body. A system of 3 interlocked loops of wire which when pulled into the catheter cause the loops to close and catch the targeted foreign body. Using a wire snare, like the En Snare, is only successful when there is a free floating end to the foreign body Using a wire snare, like the En Snare, is only successful when there is a free floating end to the foreign body Some foreign bodies are caught at awkward angles and require a better orientation in order to be pulled inside the catheter to reduce damage to the vessels during retrieval. Some foreign bodies are caught at awkward angles and require a better orientation in order to be pulled inside the catheter to reduce damage to the vessels during retrieval.

Advantages There are some advantages to using a forcep-like device over using wire snares for foreign object retrieval: Greater maneuverability (rotational and “grasping” area) Greater maneuverability (rotational and “grasping” area) The ability to dislodge a foreign body trapped with no free end: the ability to grab the foreign body in the middle of the object The ability to dislodge a foreign body trapped with no free end: the ability to grab the foreign body in the middle of the object Less damage to the endothelium or vascular wall when removing sharp dislodged objects Less damage to the endothelium or vascular wall when removing sharp dislodged objects

How can this tool be used? The En Snare, as well as any future devices foreign body removal devices can be used in: Indwelling Venous Catheter Repositioning Indwelling Venous Catheter Repositioning An indwelling venous catheter allows for venous access for long periods of time (months to years), and it is more easily repositioned with a retrieval device. An indwelling venous catheter allows for venous access for long periods of time (months to years), and it is more easily repositioned with a retrieval device. Snare Assisted Guide Wire Capture Snare Assisted Guide Wire Capture When introducing a wire into the body, the use of a snare entered through a different incision can aid in guiding the wire where it needs to go (i.e. capturing a wire over the aortic bifurcation). When introducing a wire into the body, the use of a snare entered through a different incision can aid in guiding the wire where it needs to go (i.e. capturing a wire over the aortic bifurcation).

How can this tool be used?  Foreign Body Removal  Stents, wires, thrombi, etc.

Primary Objective The current tool being used for foreign body retrieval has limited maneuverability The current tool being used for foreign body retrieval has limited maneuverability To design a device which can not only “grab” foreign bodies, but which can also manipulate them in such a way as for easier removal. To design a device which can not only “grab” foreign bodies, but which can also manipulate them in such a way as for easier removal.

Performance Criteria This tool will be used to perform intravascular retrieval from peripheral arterial or venous access sites. This tool will be used to perform intravascular retrieval from peripheral arterial or venous access sites. Its size could range from 1-8 mm in diameter and cm long. Its size could range from 1-8 mm in diameter and cm long. The goal is to be able to use the tool to reorient and remove debris –both natural and synthetic- from vasculature of small to large radii through a catheter. The goal is to be able to use the tool to reorient and remove debris –both natural and synthetic- from vasculature of small to large radii through a catheter. Current techniques do not allow for effective reorientation and subsequent alignment with a catheter for retrieval. Current techniques do not allow for effective reorientation and subsequent alignment with a catheter for retrieval.

Work Completed Met with Michael Barnett about project specifics, discussing most common current methods. Met with Michael Barnett about project specifics, discussing most common current methods. Established project goals and timeline (proposal) Established project goals and timeline (proposal) Establish project specifics pertaining to constraints for tool Establish project specifics pertaining to constraints for tool Created basic concept drawings, and performed literature searches to compare with existing designs. Created basic concept drawings, and performed literature searches to compare with existing designs.

Current Work Researching information on En Snare, mainly looking for ways to improve the design. Brainstorming and drawing rough sketches of different ways to allow reorientation of foreign bodies and threading them into the device. Researching information on En Snare, mainly looking for ways to improve the design. Brainstorming and drawing rough sketches of different ways to allow reorientation of foreign bodies and threading them into the device. Meet with Dr. Barnett and to watch related surgery. Meet with Dr. Barnett and to watch related surgery. Catheter Lab Catheter Lab

Future Work Determine what budget is necessary by discussing with advisor Determine what budget is necessary by discussing with advisor Determination of the best design sketched Determination of the best design sketched Designing the best determined model using an autoCAD tool. Designing the best determined model using an autoCAD tool. In a week or two, our goal is to have one or more feasible foreign body retrieval tools completely designed. In a week or two, our goal is to have one or more feasible foreign body retrieval tools completely designed. We consider success in the overall academic year to be the completion of an acceptable prototype. We wish to be at a stage where the prototype appears promising enough for someone else to be willing to take the design to completion should we choose to conclude our work at graduation. We consider success in the overall academic year to be the completion of an acceptable prototype. We wish to be at a stage where the prototype appears promising enough for someone else to be willing to take the design to completion should we choose to conclude our work at graduation.