Detector design optimization for push-pull IR and for surface assembly and corresponding IR requirements Tom Markiewicz/SLAC SLAC BDS Kick-Off-Meeting.

Slides:



Advertisements
Similar presentations
SiD Surface assembly Marco Oriunno (SLAC) MDI-CFS Meeting Sep. 4-6, 2014, Ichinoseki (Japan)
Advertisements

Assembly Hall in Hybrid-A’ and ILD 2014/9/6 Yasuhiro Sugimoto 1.
Global Design Effort Goals and Introduction Andrei Seryi, SLAC, September 17, 2007.
SiD assembly Marco Oriunno (SLAC), May. 14, 2014 ALCW 2014, Fermilab Infrastructures & Timeline for Hybrid Access.
Global Design Effort Detector concept # Plenary introductory talk IRENG07 Name September 17, 2007.
NLC - The Next Linear Collider Project IR Layout Tom Markiewicz SLAC LCWS Cornell 15 July 2003.
DH in Hybrid-A and ILD 2014/9/5 Yasuhiro Sugimoto 1.
Experimental hall in Japanese mountain site Y. Sugimoto ILD MDI/Integration 1.
Philip Burrows ACFA Workshop, Sendai 3/03/081 SiD Philip Burrows John Adams Institute Oxford University Thanks to: Marco Oriunno,
Push Pull Considerations
Global Design Effort Detector concept Plenary introductory talk IRENG07 Kurt Krempetz September 17, 2007.
1 FD Support and Pacman for GLDc 27 Aug Yasuhiro Sugimoto KEK.
1 GLD Surface Assembly Y. Sugimoto KEK
1 ILD/CMS Engineering Meeting M. Joré – ILD integration philosophy Integration philosophy of ILD Matthieu Joré – January 21st Integration of the subdetectors.
SID Engineering Marco Oriunno (SLAC), Jan CLIC Workshop, CERN Toward the TDR.
1 Alternative assembly option of ILD Y.Sugimoto 2010/10/18 ILD Integration
Experimental hall in Japanese mountain site Y. Sugimoto 1.
Global Design Effort Push-pull studies How to proceed LCWS07 June 1, 2007 at DESY Andrei Seryi for BDS Area leaders Deepa Angal-Kalinin, A.S., Hitoshi.
October 13, 2006 Global Design Effort 1 International Linear Collider Machine Detector Interface Materials for discussion at Engineering Forum: experiences.
PD5: Detector Integration / Machine Detector Interface T. Markiewicz/SLAC 15 May 2014 SiD Meeting / AWLC Fermilab Summary.
Global Design Effort Beam Delivery System => EDR LCWS07 June 2, 2007 at DESY Andrei Seryi for BDS Area leaders Deepa Angal-Kalinin, A.S., Hitoshi Yamamoto.
Beam Commissioning Marco Oriunno (SLAC), May 14, 2014 ALCW 2014, Fermilab Engineering Issues.
Philip Burrows SiD Meeting, Paris 11/02/081 Machine Detector Interface Issues Philip Burrows John Adams Institute Oxford University Thanks to: Tom Markiewicz.
September 18, 2007H. J. Krebs1 SiD Collaboration One Piece End Door Design Concept plus Forward Equipment Interfaces H. James Krebs SLAC September 18,
MEA Machine and Experiment Assembly 1 Norbert Meyners, MEA Engineering Forum at CERN 12.Okt Thoughts about LDC Hall and Assembly (Work is not finished.
Si D in 14mrad/14mrad/z=0 ILC T. Markiewicz/SLAC SiD Advisory Group 14 August 2006.
1 GLD and GLDc Sep. 12, 2007 Y. Sugimoto KEK. 2 Compact GLD Option Motivation –GLD and LDC will write a common LoI –The detector design should have common.
SiD IR & MDI Engineering Progress Prelude to a Discussion of Integration with ILD and Based on Marco Oriunno’s Jan 2008 Talk at SiD CM Tom Markiewicz/SLAC.
SiD Engineering Design for the LOI Kurt Krempetz (Layer 5) (Layer 1) VXD.
Global Design Effort Critical Interaction Region Issues, Report from the IR engineering workshop Andrei Seryi, SLAC October 24, 2007.
MDI DBD Editors Report Tom Markiewicz/SLAC SiD Collaboration Meeting, SLAC 22 August 2012.
Cost Issues Y.Sugimoto, A.Maki Estimation Procedure Get unit cost from the cost estimation for GLD(DOD) Estimate (relative) amount of return-yoke.
A. Hervé - 17 Oct CLIC-Workshop CLIC Workshop: 17 Oct. 07 Interaction Region Engineering at ILC Push-Pull Option A. Hervé/CERN.
A. Hervé - 17 Sept ILC-IRENG IRENG07 Workshop: 17 Sept. 07 Various Possibilities for disposition of Experimental Area A. Hervé/CERN.
MEA Machine and Experiment Assembly Norbert Meyners, MEA 17. Sept. 2007ILC IRENG07; SLAC1 LDC Engineering Design (Status)
SiD IR & MDI Status & Comments Tom Markiewicz/SLAC ALCPG, Fermilab 26 October 2007.
SiD Engineering and Solenoid Kurt Krempetz (Layer 5) (Layer 1) VXD.
9/17/07IRENG071 Cryogenic System for the ILC IR Magnets QD0 and QF1 K. C. Wu - BNL.
GLD experimental hall and detector assembly Y.Sugimoto KEK 27 Sep
SiD Collaboration Meeting Highlights Tom Markiewicz/SLAC ILC BDS Meeting 08 May 2007.
Philip Burrows MDI Panel Meeting 15/08/06 Philip Burrows John Adams Institute Oxford University SiD and IR/MDI Issues.
September 20, 2007H. J. Krebs/B. Wands/B. Cooper1 SiD Collaboration Preliminary End Door Design Concept Support of Forward Systems H. James Krebs Bob Wands.
ILD and SiD in Japanese site (from discussions in SiD/ILD E/D Interface Working Meeting) Yasuhiro Sugimoto, Marco Oriunno 2011/12/15 SiD
SiD MDI Issues Tom Markiewicz/SLAC Beijing ACFA/GDE Meeting 05 February 2007.
Magnet Infrastructures and Cavern Layout CLIC Detector WG5, April 1st 2010 Andrea Gaddi Physics Dept. - CERN.
Experimental hall in Japanese mountain site 2011/11/30 Yasuhiro CFS Webex meeting 1.
8/29/07K. C. Wu - Brookhaven National Lab1 Major Components in ILC IR Hall Interchangeable Detectors.
MEA Machine and Experiment Assembly Norbert Meyners, MEA 12. July 2007ILC IRENG07 WG-A1 LDC Engineering Design (Status) Introduction General Design Detector.
Philip Burrows SiD Monthly Phone Meeting, 4/10/071 IR Issues from IRENG07 Philip Burrows John Adams Institute Oxford University.
12 July 2007IRENG07 WG-A M. Breidenbach1 SiD Concept SiD is relatively modest in scale compared to the LHC detectors, and comparable to SLD: Tracker Radius.
SiD MDI Update Topics for Discussion Tom Markiewicz/SLAC ILC BDS Meeting 15 May 2007.
Octobre LAL Orsay Report from the IRENG07 workshop at SLAC W. Lohmann, DESY from Septembre 17 – 21, ~ 100 participants - plenary and parallel sessions.
M.Oriunno, SLAC 1 SiD installation with horizontal access shafts Marco Oriunno, SLAC SiD/ILD Engineering Meeting SLAC, December 2011.
1 Update of detector hall in mountain regions Y.Sugimoto in Granada.
Miscellaneous MEC Topics Mainz, CM September 2016, MEC Session J
Experimental Hall in Mountain Regions
Machine Detector Interface Design Updates
2016/9/30 Yasuhiro Infra/CFS mini-ws
Experimental hall design in Japanese site
Present status of the flux return yoke design
BDS Cryogenic System RDR Status and EDR Plans
Update of experimental hall in Japanese mountain site
SiD LoI Costs M. Breidenbach 29 July 2010 M. Breidenbach.
Detector hall in mountain regions
Changes to SiD since the DBD
ILD-0 overall dimensions C.Clerc ILD meeting, Seoul 17/02/09
Radiation Physics requirements for the IR
SiD IR Layout M. Breidenbach, P. Burrows, T. Markiewicz
Detector hall in mountain regions
A 12-min Introduction to The ILC Machine Detector Interface and SiD
Presentation transcript:

Detector design optimization for push-pull IR and for surface assembly and corresponding IR requirements Tom Markiewicz/SLAC SLAC BDS Kick-Off-Meeting 12 October 2007

SLAC BDS KOM T. Markiewicz/SLAC 2 of 35 Charge: System integration and optimization Quantify the worth/cost value, discuss cost drivers, evaluate performance/cost derivatives, review design decisions in terms of cost impact and discuss possibilities of further refinement. Aim to identify the performance driven specifications for accelerator components and especially CFS and discuss how engineering cost-performance trade-offs will be performed. Should include discussion of machine-detector connection and optimization, and specifically include discussion of the integrated engineering of push-pull IR, based on IRENG07 workshop, aimed to reduce the risk of performance and cost of this solution.IRENG07 workshop

SLAC BDS KOM T. Markiewicz/SLAC 3 of 35 Detector Truths (IMHO) There are no detectors yet, only concepts –Letters of intent are forthcoming –Detector Engineering lags Machine Engineering GLDc, LDC, & SiD are seriously treating Push-Pull (P-P) & Surface Assembly (S-A) Most discussions at IRENG’07 regarding detectors concepts and P-P / S-A touched –Civil: Cavern & surface layout, cranes, services –Cryo: 2K/4K Refrigerators for QD0 & plumbing –These will be discussed by Osborne/Parker Will review IRENG’07 detector presentations for comments independent of civil & cryo

SLAC BDS KOM T. Markiewicz/SLAC 4 of 35 3 Major Developments Since LCWS’07 (DESY) GLDc design introduced which incorporates a self-consistent model for push-pull and surface assembly Major contribution of CERN civil group to layout/cavern/assembly/platform/access discussion via fabulous layout schematics Formation of ~10 member Si D Engineering team

SLAC BDS KOM T. Markiewicz/SLAC 5 of 35 Compact GLD = GLDc

SLAC BDS KOM T. Markiewicz/SLAC 6 of 35 GLDc Assembly: 7 major pieces Barrel part (Yoke+ECAL+HCAL) – T = 6210 T –Pure CMS style assembly can be done by splitting the barrel part into 3 rings Each Door (Yoke + ECAL+HCAL) –3050 T + 270T = 3320 T –and splitting each end cap part into two halves Cranes: –50~100 T underground depending on Pacman design –2,000 T crane for the shaft –80 T crane in the surface assembly hall set by 24 Fe yoke octants Shaft sizes, crane access and underground vault sized by CFS for GLDc as discussed by J. Osborne

SLAC BDS KOM T. Markiewicz/SLAC 7 of 35 GLDc QD0 Support Based on Cantilevered Support Tube with Base on 2 x 10.5m wide Platform

SLAC BDS KOM T. Markiewicz/SLAC 8 of 35 Disassembly of PACMAN for Push-Pull

SLAC BDS KOM T. Markiewicz/SLAC 9 of 35 On-beamline & Off-beamline Access “A” Pacman split back and unsplit door rolls to tube support pillar “A” & “B” Pacmen and Endcap Door split back

SLAC BDS KOM T. Markiewicz/SLAC 10 of 35 LDC Assembly & Access Model Similar to GLDc 2*982,5t 1059t 1666t 1059t 2*982,5t If not split the end cap pieces would be the heaviest part to be lowered!

SLAC BDS KOM T. Markiewicz/SLAC 11 of 35 Split Endcaps not Fundamental to Design Under Study! The structure of the detector should allow both. Factor 2 more bending if split! At the moment we prefer end cap halves bolted together with the possibility to open in an major operation if necessary!

SLAC BDS KOM T. Markiewicz/SLAC 12 of 35 QD0/FCAL Held in Support Tube Support Tube Pillar Sets Max Door Opening Tube Guided in EndCap and Held by Spoke Arrangement at TPC/ECAL Juncture >2.5m First Idea Pillar Spokes Guideance

SLAC BDS KOM T. Markiewicz/SLAC 13 of 35 LDC Opens On-Beamline Via Split PacMan Need 2.5-3m to access the detector (Top view) –Support Structure Support –Service Cryostat –Supply Line close to QF1

SLAC BDS KOM T. Markiewicz/SLAC 14 of 35 TPC Exchange Off Beamline  If not split, the end cap yoke has to be moved 8,5m longitudinal (or aside) for TPC exchange!  QD0 and service cryostat have to go with the end cap yoke while the Helium supply line is not cut!

SLAC BDS KOM T. Markiewicz/SLAC 15 of 35 Similar Width “Platform” to GLDc The supply lines from the service cryostat to the QD0s go from the bottom through the shielding. The cryostats are connected via flexible lines to Helium supply. To allow a further opening the service cryostat and the QD0 can be attached to the yoke end cap.

SLAC BDS KOM T. Markiewicz/SLAC 16 of 35 Relative Merits of Platform Under Discussion Detector should be as ridged as a platform It has to carry the QDO support and the service cryostat!  20m wide (Instead of 15.5m) Charming! It disentangles the transverse and longitudinal movement Good solution for cables and supply lines

SLAC BDS KOM T. Markiewicz/SLAC 17 of 35 SiD: Doors & Barrel Are Not Split Minimum of 3 pieces to lower “Pure CMS” concept gantry requirements: 4000T Barrel Arch supports, Yoke, H/E-cals, coil 2500 T Doors Yoke, H/E-cals

SLAC BDS KOM T. Markiewicz/SLAC 18 of 35 Sequence of Operations for Surface Assembly/Test & Underground Reassembly Detector subassembly construction & surface tests –Octants of muon chamber instrumented barrel yoke, barrel Hcal, barrel Ecal –Four sub-modules of EC return flux instrumented with muon chambers, donut Hcal, Ecal –Tracker, vertex and FCAL packages Surface Magnet test –Assemble barrel support and the bottom 5/8 flux return octants –Drop in coil & cover with remaining 3/8 octants –Assemble two door legs and 4 360° (180 °?) plates of flux return –Test magnet and disassemble Lower detector –Reassemble lower barrel with supports below ground –Load barrel HCAL and ECAL modules into coil cryostat via threaded beam –Lower loaded coil package and capture with upper barrel yoke segments –Depending on crane capacity Lower fully assembled door Lower door pieces, the last plate with the Endcap Ecal & Hcal, and reassemble Tracker, VXD and FCAL installed below ground at last minute

SLAC BDS KOM T. Markiewicz/SLAC 19 of 35 A Surface Assembly/ Underground Reassembly Scenario for SiD 600T Surface crane & No Gantry M-TonsStainless HCAL RadiatorTunsgten HCAL Radiator BarrelEndcap x2BarrelEndcap x2 EM Cal HCAL Coil Iron2966/8= /4= /8= Support x 2 (each ~5%Fe) Total to Lower Loaded Coil=573 Assembled Door=2402 Loaded Coil=542 Assembled Door=1479 Shaft Diameter(m) 8.3m m

SLAC BDS KOM T. Markiewicz/SLAC 20 of 35 SiD r<50cm, L*=3.664m, 14mrad, Push-Pull, Door Closed 3339mm 190mm Ø Liquid He Line 264mm 2207mm PACMANIMMOBILE FLOORYOKETUNNEL 3005mm

SLAC BDS KOM T. Markiewicz/SLAC 21 of 35 SiD r<50cm, L*=3.664, 14mrad Crossing Angle, Push-Pull, Door Open 2m 190mm Ø Liquid He Line

SLAC BDS KOM T. Markiewicz/SLAC 22 of 35 Door Closed, Permanent QD0 Liquid He Line Liquid He Line “PACMAN” Shielding CLOSED Door Earthquake “Foot” He2 HXHe Interface Box 3005mm 3m

SLAC BDS KOM T. Markiewicz/SLAC 23 of 35 Door Open, Permanent QD0 Liquid He Line “PACMAN” Shielding 2000mm 91cm

SLAC BDS KOM T. Markiewicz/SLAC 24 of 35 FCAL/QD0 Supported with Door Closed Door QD0 FCAL 2cm x 4cm x 5m Support Bar 19cm 3cm Connector Bolts(?)

SLAC BDS KOM T. Markiewicz/SLAC 25 of 35 FCAL/QD0 Supported with Door Open QD0 FCAL 2.0m Whether Spider or tube used for Support, SiD has assumed it will be completely supported by door (not cantilevered off a post to the ground) but has not proposed a way to fix it in z when door opens

SLAC BDS KOM T. Markiewicz/SLAC 26 of 35 SiD IR Hall Assumptions 1.Push-Pull and doors opening with Hilman Rollers 2.Racks and ancillaries on SiD or on a side platforms (location driven by the the fringe field) 3.Cold Box off detector (in the hall) 4.Flexible cryogenic transfer line (100mm OD) Solenoid-Cold box 5.He compressors remote

SLAC BDS KOM T. Markiewicz/SLAC 27 of 35 SiD closed on the beam Cold box He II Power Supply Dump Resistor Cryostats (QD0s) Cryo line QD0 Cryo line Solenoid Platform with LV, HV, etc Cold box Solenoid

SLAC BDS KOM T. Markiewicz/SLAC 28 of 35 SiD push-pull (30 meters stroke )

SLAC BDS KOM T. Markiewicz/SLAC 29 of 35 6 meters SiD 6 m off the beam

SLAC BDS KOM T. Markiewicz/SLAC 30 of 35 4 th Detector Concept

SLAC BDS KOM T. Markiewicz/SLAC 31 of 35 Gross Dimensions 4 th Does not respect BDS Requirement that QDF Unmoved

SLAC BDS KOM T. Markiewicz/SLAC 32 of 35 4th Underground Assembly “CMS” Surface Assembly not addressed

SLAC BDS KOM T. Markiewicz/SLAC 33 of 35 To Open 4 th On-Beamline on beamline –move Lumi/Beam-Cals out –move wall-of-coils out 2m –lift muon spectrometer chambers out vertically –move calorimeter modules out axially At this point, the interior and the tracker ends are accessible. The FF support has not been moved. –the tracking chamber can be ‘push-pulled’ to the other end –vertex chamber is moderately accessible in this position I do not understand “move Lumi/Beam cals out”

SLAC BDS KOM T. Markiewicz/SLAC 34 of 35 Summary of Push Pull & Surface Assembly Aspects of MDI GLDc and LDC have similar designs with similar crane/shaft requirements wherein FCAL/mask/QDO package supported in a tube off cantilevered off a pillar to ground (or platform) GLDc shows a moving platform while LFC says either platform or rollers would work SiD requires 2x gantry capacity for “CMS” surface assembly –not convinced that non-CMS-like underground assembly is better –Feels (MIB at least) that platform is expensive solution germaine to CERN geology & LHC detector complexity SiD FCAL/mask/QDO package supported in a spider or tube directly from doors –Needs to address how z motion of support tube is controlled 4 th does not consider surface assembly and wants to translate the QF1-QD0-Detector-QD0-QF1 package in push/pull

SLAC BDS KOM T. Markiewicz/SLAC 35 of 35 Interface Issues 1 st order self-consistent PACMAN shielding invoked by GLDc, LDC, SiD. However, engineering required –To see underground crane capacity required GLDc shows 0.5m Fe / 2.0m concrete from r=0.5m SiD shows 1.0m Fe/ 2.0m concrete from f=0.25m Rad Phys calculation done for 0.5 m Fe / 2.0m Con from r=1.25m –To understand where detector A to detector B PACMAN interface occurs –To understand how to remove detector A specific PACMAN shielding “trapped” on detector B side of the beamline Hinged to the doors of detector A? Platform A, platform B, Floor, detector A, detector B interfaces –If “A” needs/desires moving platform solution, must “B” adopt as well

SLAC BDS KOM T. Markiewicz/SLAC 36 of 35 QD0 Package Adjustment Mechanism Likely to Require Significant Radial Space Knut Skarpaas 2000 Design of Integrated Coarse/Fine Cam/Piezo Mover System for a stiffened PM QD0

Hall Parameters - Length around 90 m Space reserved for shielding wall 8 m working corridor, could be from 0 to 100% on any one side of experiment in 2-m increments, using ‘working platforms’ to fill the gaps Space for ancillaries recovered from curved end-wall Maximum stroke 28m