Femtosecond-Pulse Splitter for Two-Photon Microscopy WILLIAM BLANCHARD | PATRICK FORD | CINDY JUAREZ | KURTIS KOLNOWSKI | DAVID TSE Department of Mechanical.

Slides:



Advertisements
Similar presentations
POWERPOINT PRESENTATION ON POLARISED MICROSCOPE
Advertisements

AP Physics Mr. Jean March 30 th, The plan: Review of slit patterns & interference of light particles. Quest Assignment #2 Polarizer More interference.
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
Laser Needle Guide for the Sonic Flashlight David Wang 1,3,4, Bing Wu 2,3, George Stetten 1,2,3,4,5 1 Department of Biomedical Engineering, Carnegie Mellon.
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
COMPUTER MODELING OF LASER SYSTEMS
Confocal & Two-photon Microscopy. Contents 1.Two-Photon Microscopy : Basic principles and Architectures 2. Resolution and Contrast in Confocal and Two-Photon.
The Speed of Light How to hold a hallway hostage for fun and intellectual profit. (starring: the equipment)
Development of a thermal cooling system for a PMT (Photo Multiplier Tube) Summer Researcher Yasmine Salas Colorado State University Advisor: Dr. Julia.
Amplitude Control: Closing the Loop in a Zero Path Length Difference Michelson Interferometer Michael G. Littman, Michael Carr , Laurent Pueyo, Jeremy.
Robert: Motivation Principles of Optics Applications Optimization Andy: Materials Loss vs. amplification Theoretical problems Overview = 4WM.
G D Calibration of the LIGO Interferometer Using the Recoil of Photons Justice Bruursema Mentor: Daniel Sigg.
Physics 52 - Heat and Optics Dr. Joseph F. Becker Physics Department San Jose State University © 2005 J. F. Becker.
POSTER TEMPLATE BY: Optical Coherence Tomography Assembly of the System and Analysis of Sciatic Rat Nerve Daniel deLahunta.
Newton’s Rings Another method for observing interference in light waves is to place a planoconvex lens on top of a flat glass surface, as in Figure 24.8a.
Mfd Sir Isaac Newton ( ) believed that light consisted of particles or corpuscles. The Dutch scientist, Christian Huygens ( ), agreed.
Applications of Diffraction Outline - Interference - Diffraction - Examples:. Diffraction Gratings. Photonic Crystals. Interference Lithography - Holography.
What is OCT? Ultrahigh resolution optical coherence tomography (UHR OCT) is an upcoming new technology that allows non-invasive, optical medical diagnostic.
Interference Diffraction and Lasers
Introduction to Microscopy: The Light Microscope The TEM The SEM.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Artificial Intelligence Lecture No. 28 Dr. Asad Ali Safi ​ Assistant Professor, Department of Computer Science, COMSATS Institute of Information Technology.
Advanced Optics Lab at San Jose State University Ramen Bahuguna Department of Physics.
Dense Wavelength Division Multiplexing (DWDM) Technology
Miriam Israelowitz 1 and Dr. David L. Wilson 2 1 Department of Physics, Case Western Reserve University, Cleveland OH, 2 Deparment of Biomedical Engineering,
Abstract: A laser based ultrasonic technique for the inspection of thin plates and membranes is presented, in which Lamb waves are excited using a pulsed.
Reflection Regular reflection occurs when parallel light rays strike a smooth surface and reflect in the same direction. Diffuse reflection occurs when.
Intra-cavity Pulse Shaping of Mode-locked Oscillators Shai Yefet, Naaman Amer and Avi Pe’er Department of physics and BINA Center of nano-technology, Bar-Ilan.
FEMTOSECOND LASER FABRICATION OF MICRO/NANO-STRUCTURES FOR CHEMICAL SENSING AND DETECTION Student: Yukun Han MAE Department Faculty Advisors: Dr. Hai-Lung.
Femto-second Measurements of Semiconductor Laser Diodes David Baxter
Advanced Biology Visualizing Cells. The Human Eye  Resolution – The minimum distance two points can be apart and still be distinguished as two separate.
Digital two photon microscopy for multiple fast signals acquisition Laboratory of Advanced Biological Spectroscopy (L.A.B.S.) University of Milan - Bicocca.
Sensitive gas absorption coefficient measurements based on Q reduction in an optical cavity. 1) Pulsed laser ring-down time measurements 2) Chopped CW.
1/10 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 10, 2006) Phase.
Femtosecond lasers for sub-surface tissue cutting Chris B. Schaffer.
Advancement in photo-injector laser: Second Amplifier & Harmonic Generation M. Petrarca CERN M. Martyanov, G. Luchinin, V. Lozhkarev Institute of Applied.
Longitudinal Motion Characteristics between a Non- Matched Piezoelectric Sensor and Actuator Pair Young-Sup Lee Department of Embedded Systems Engineering,
We have experimentally observed a similar qualitative behavior by measuring the ratio between the CW and ML intra-cavity powers as a function of Z for.
Effect of Mirror Defect and Damage On Beam Quality T.K. Mau and Mark Tillack University of California, San Diego ARIES Project Meeting March 8-9, 2001.
A Multi-Moded RF Delay Line Distribution System for the Next Linear Collider S. G. Tantawi, G. Bowden, Z.D. Farkas, J. Irwin, K. Ko, N. Kroll, T. Lavine,
Date of download: 5/27/2016 Copyright © 2016 SPIE. All rights reserved. (a) Schematic of the light path. The galvo scanners are mounted above periscopes.
1 Fatima Hussain. Introduction The unprecedented demand for optical network Capacity has fueled the development of long-haul optical network systems which.
Light microscope.
Compton Gamma-ray Generation Experiment by Using an Optical Cavity in ATF POSIPOL 2007 Workshop at LAL Hirotaka Shimizu Hiroshima University.
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
DESIGN STUDY November 28 th - 30 th 2005First EURISOL Design Study TOWN MEETING High Power RF Amplifiers Development at LNL Fabio Scarpa - INFN LNL.
Interference and Diffraction
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
UNIT-3 ADVANCES IN METROLOGY
Starter: Microscopes Which image is from the light microsope? How do you know?
Interference and the Wave Nature of Light
Laser Components.
Contents Abstract Introduction VRD (Virtual Retinal Display) Basics
AUTOMATED LIQUID DELIVERY SYSTEM
Point Detector Aperture
High-Density 3D Single Molecular Analysis Based on Compressed Sensing
Volume 104, Issue 4, Pages (February 2013)
PARAMETRIC SUB-BOTTOM PROFILER: A NEW APPROACH FOR AN OLD PROBLEM
Helmut J. Koester, Dagmar Baur, Rainer Uhl, Stefan W. Hell 
Λ-Repressor Oligomerization Kinetics at High Concentrations Using Fluorescence Correlation Spectroscopy in Zero-Mode Waveguides  K.T. Samiee, M. Foquet,
The Mobility of Phytochrome within Protonemal Tip Cells of the Moss Ceratodon purpureus, Monitored by Fluorescence Correlation Spectroscopy  Guido Böse,
Vital imaging: Two photons are better than one
Light microscope.
Scalar theory of diffraction
Supraresolution Imaging in Brain Slices using Stimulated-Emission Depletion Two- Photon Laser Scanning Microscopy  Jun B. Ding, Kevin T. Takasaki, Bernardo.
Mechanical Distortion of Single Actin Filaments Induced by External Force: Detection by Fluorescence Imaging  Togo Shimozawa, Shin'ichi Ishiwata  Biophysical.
Extracellular Space Volume Measured by Two-Color Pulsed Dye Infusion with Microfiberoptic Fluorescence Photodetection  Mazin Magzoub, Hua Zhang, James.
CLIC Feasibility Demonstration at CTF3
Polarized Fluorescence Resonance Energy Transfer Microscopy
The Mobility of Phytochrome within Protonemal Tip Cells of the Moss Ceratodon purpureus, Monitored by Fluorescence Correlation Spectroscopy  Guido Böse,
Presentation transcript:

Femtosecond-Pulse Splitter for Two-Photon Microscopy WILLIAM BLANCHARD | PATRICK FORD | CINDY JUAREZ | KURTIS KOLNOWSKI | DAVID TSE Department of Mechanical and Aerospace Engineering and School of Medicine at University of California San Diego Sponsored by Dr. Anna Devor Overview A two-photon laser scanning microscope (TPLSM) is used for high resolution imaging and functional analyses. More specifically, it studies the activity of single neurons in the brains of rats and mice with the aid of fluorescent indicators. Problem: Only ten percent of the laser’s available power can be used before photo induced damage occurs. Solution: We have designed a mechanism to split 1 pulse of the laser beam into 8 pulses. Components: This mechanism is assembled on a 38.1 cm x cm x cm aluminum breadboard and includes a pulse splitter, two beam splitters, seven mirrors, and a half wave plate. Results: This pulse splitter module is used to reduce the peak excitation intensity while maintaining the average power at the specimen. As a result, the signal-to-noise ratio of the produced images is enhanced while not inflicting tissue damage upon the specimen. Clearer images produced by the TPLSM and pulse splitter module, allows further investigation into the brain and the function and behavior of the neurons. Acknowledgements We would like to thank the following people for making this project possible: Dr. Anna Devor Dr. Tustaniwskyj, Morgan Cope, Tom Chalfant, David Lischer Impact on Society This project has a positive impact on society because the full potential of medical research equipment can be realized. A Two-Photon microscope, in general, is beneficial in contributing to discoveries in neuroscience. However, it is limited in its application by photodamage. A pulse splitter has the capability to enable deep tissue imaging with reduced photodamage. The compact size, the ease of installation to existing microscopes and the obvious imaging advantages of the pulse splitter make it a beneficial addition to a Two-Photon microscope and enables advancements in neurobiology. References 1.“High-speed, low-photodamage nonlinear imaging using passive pulse splitters”, N. Ji, J. Magee, E. Betzig, Nature Methods (2008), vol. 5, no. 2, p “Highly nonlinear photodamage in two-photon fluorescence microscopy”, A. Hopt, E. Neher, Biophysical Journal (2001), vol. 80, p “Principles of two-photon excitation microscopy and its application to neuroscience”, K. Svoboda, R. Yasuda, Neuron (2006), vol.50, p Summary of Design The module works by using two beam splitters, two flipper mirrors, four mirrors and a pulse splitter, as shown in Figure 1. The path goes as follows. 1)The laser beam strikes the first flipper mirror when it is down and is reflected into the first beam splitter. 2)The first beam splitter splits the incoming beam into two pulses. 3)One beam enters the pulse splitter while the other pulse is reflected off of two mirrors to achieve a delay time. 4) Once a beam enters the pulse splitter housing it is separated into four different pulses, as shown in Figure 2. Figure 1 : CAD model of final design Pulse Splitter Design To determine the size of the glass used in the pulse splitter, a mathematical model was constructed which related the time of the delay desired to the thickness and diameter needed to achieve the delay. Table 1 shows that at the desired delay of 450 picosecond (ps), the required thickness is 7.62 cm and cm in diameter. However, it was not feasible to attain this glass size. Eventually, a 1.25 cm thick and 2.82 cm diameter glass which produced a 74 ps delay was used. Delay (ps) Thickness (cm)Diameter (cm) Table 1: Size of Glass Needed for Specified Delay Figure 2 : Pulse enters window and is split four times. Pulses in parenthesis pass through silica side first. Delay Time Analysis The pulse spacing and output power was calculated for each pulse. The results can be seen in Figure 4. Each pair of pulses was delayed exactly picoseconds relative to each other. This time spacing is constant due to the thickness of the fused silica substrate. The pre-pulse splitter delay affects the spacing between the first two and final two pulse pairs. The post-pulse splitter delay affects the distance between the first and third pair of pulses. Figure 4 : Output power and pulse spacing of input laser power of 100%. The theoretical output power with zero losses is shown to be 12.50% Flipper Mount The flipper mirrors are used to bypass the pulse splitter module. This design feature was implemented because our sponsor wanted to bypass the module without taking it out of the microscope and misaligning it. Bypassing the pulse splitter is essential for scanning deeper tissue where the full intensity of the laser is needed. The flipper mounts, shown in Figure 3, enable the laser beam to bypass the module. Future Improvements RecommendationsJustification Multiple Pulse Splitters and Beam splitters Used for increasing the number of pulses. Can possibly increase up to 128x Pulse Splitter module. Use a delay line instead of relying on passive delay Reduce the size of the module and spread the pulses more evenly. Larger Pulse Splitter windowIncrease the inter-pulse delay produced within pulse splitter to evenly space all pulses. 5)Both beams enter the pulse splitter and eventually create 8 pulses. 6) Pulses are reflected onto a wave plate which changes the polarization of the waves of the beam. 7) Next, the eight separate pulses are recombined in the final beam splitter. 8) Finally, the eight separate pulses are reflected onto the last flipper mirror which reflects the pulses out of the module. Figure 5 : Finished Assembly of the Pulse Splitter Figure 3 : CAD model of Flipper Mount Figure 6 : Finished Assembly of the Pulse Splitter Module