Typical Telecommunications Network

Slides:



Advertisements
Similar presentations
Mitigation of AC Induced Voltage On Buried Metallic Pipelines
Advertisements

Earthing of MV and LV Distribution Systems: A multi-faceted problem.
Chapter 12 Transformers. Chapter 12 Transformers.
 Early dialogue is vital (BEFORE buying land or doing detailed design) E.g. rural crossroads Often problems can be avoided at nil or minimal cost at a.
Stray Current Investigations A Method of Troubleshooting Stray Current on Underground Residential Distribution (URD) Loops Stacey Mighty Malcolm Distribution.
EE4503 Electrical Systems Design
M.PEGORARO Grounding Workshop 24th Jan 08 DT GROUNDING & SHIELDING Presented by A. BENVENUTI.
STRAY CURRENT CORROSION
1 Distributed Generation and Power Quality. 2 Relaying considerations DG infeed may reduce the reach of overcurrent relays –DG feeds fault, so utility.
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
AC Mitigation Overview
Problems and solutions in optical network plants in Hungary Torino, March 1998 Technological problems and solutions in optical network plants in.
Pulse Echo Tester works on principle.
1 Version 3.0 Module 3 Networking Media. 2 Version 3.0 Cable Specifications Cables have different specifications and expectations pertaining to performance:
Electrical Systems Electrical Engineering in Railways –Rolling Stock –Communications & Control –Signalling –LV Installations in Stations and Buildings.
Basic Electricity.
Chapter 3Transmission Lines Why use high-voltage transmission lines? The best answer to that question is that high-voltage transmission lines transport.
DET 310 UNDERGROUND CABLES
Substations. Substations Chapter 4 Substations Major types of equipment found in most transmission and distribution substations with their purpose,
PRESENTATION ON SUBSTATION DESIGN
Router. Switch Repeater Cable is the medium through which information usually moves from one network device to another. It used to connect one network.
Electrical Earthing D.K.Pathirana. Applications of earthing Protect human against lightning and earth fault condition Protect the premises against lightning.
Transmission Lines …….. Conductor Material
Network Cabling and Wireless Network
Chapter 2 Transformers.
Calculating Separation Distance and Surge Current
Transmission lines.
EPR ‘Fundamentals of Calculation of Earth Potential Rise in the Underground Power Distribution Cable Network’ by Ashok K. Parsotam (1997) available free.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Electrical Installation 2
IEEE Wind Farm Collector System Grounding for Personal Safety Summary of Topics.
Communication Markets Division © 3M All Rights Reserved. Telecom Visit for Noise Mitigation Improve Network Performance with 3M™ Solutions.
1 CCTV SYSTEMS CCTV cables. 2 CCTV SYSTEMS Cable selection is a very important consideration in the performance of a CCTV system, especially where long.
International Telecommunication Union ITU-T SG 5 Technical Session “Lightning protection” 12 December 2005, ITU Headquarters, Geneva Risk regarding safety.
Levels of high voltage: World over the levels are classified as: LOW MEDIUM HIGH EXTRA and ULTRA HIGH Voltages However, the exact magnitude of these levels.
SWER New Zealand & Australian Experience
Wiring and Grounding.
A PRACTICAL TRAINING SEMINAR ON PLCC
Frankfurt (Germany), 6-9 June 2011 Mark Davies Trevor Charlton Denis Baudin Mark Davies – UK – Session 2 – Paper 0376 New Design Methods to Achieve Greater.
Grounding Guidelines Developed for LBNE
© 2007 Ideal Industries 1 of 12 Basics Clamp-on Ground Resistance Tester.
Programmable Logic Controllers
General power system. objective Review general energy and power system Application of fundamental knowledge of principal machines, transformer and other.
Electric Current.  Electric current is the continuous flow of electric charges through a material.  Needed to power any electrical device.  Measured.
Grounding.
132KV GSS PIPAR CITY JODHPUR
Network Media. Copper, Optical, Fibre (Physical Layer Technologies) Introduction to Computer Networking.
POWER / TELECOMMUNICATIONS NETWORK CO-ORDINATION Workshop 20 June 2012 Presented by The New Zealand Committee for the Co-ordination of Power and Telecommunication.
A PRESENTATION On 400KV GSS SURPURA JODHPUR
1 Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors.
ELECTRICAL EARTHING.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
LOCATION OF CABLE FAULTS
Signal conditioning Noisy. Key Functions of Signal Conditioning: Amplification Filter  Attenuation  Isolation  Linearization.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Auto Transformer Current Flow. Principles of Auto Transformers H X H0/X0.
Radio Base Stations Sited on Power Line Towers
Dairy Farm Event Customer Observations/Complaints
Grounding.
Grounding And Safety Techniques Ms. Tahoora Qureshi, Asst. Professor
PRACTICAL METHOD FOR ANALYSIS OF GROUNDING SYSTEM OF HV/MV SUBSTATIONS LOCATED IN URBAN AND SUBURBAN AREAS.
WELCOME TO ALL.
GROUND-FAULT GROUND-CHECK MONITOR
Introduction to Computers
THUM Adapter Impact on Hazardous Area Classification
Mains Plug Wiring: Brown lead Live Blue Lead Neutral
Contactor A contactor is an electrically controlled switch (relay) used for switching an electrical power circuit. A contactor is typically controlled.
1. TURBOGENERATOR ROTOR WINDINGS
POWER SYSTEM COMMISSIONING AND MAINTENANCE PRACTICE
Presentation transcript:

Typical Telecommunications Network

Chorus’ increasingly common roadside electronic cabinets are all effectively small Telephone Exchanges

Telecommunications Circuits One earth reference on each working circuit – the Exchange earth Maximum voltages normally carried on each circuit 80 Vac ringing voltage (occasionally there) 48 Vdc always there

Key Mechanisms Earth Potential Rise (EPR) Via direct coupling to Exchange earth OR Insulation breakdown

Requires ‘out of balance’ power current (usually earth return current) Induced Voltage Requires ‘out of balance’ power current (usually earth return current)

Induced Voltage (cont.)

Induced Voltage (cont.) Earth currents return on average at the below depths: ρ = 10 Ω-m 300 m ρ = 100 Ω-m 900 m ρ = 1,000 Ω-m 3,000 m No insulation breakdown is required to impress voltages onto telecommunications conductors Mitigation options more limited, and generally more costly

Induced Voltage (cont.) E = C x L x I x K E = induced voltage (V) C = coupling factor (mutual impedance) (Ω/km) = fn (ρ,s) ρ = deep earth soil resistivity s = separation L = length of parallel (km) I = inducing current (A) K = shielding factor (≤ 1.0)

Key Impacts Human hazard Damage to telecommunications plant Noise interference

Key Impacts (cont.) Human hazard Damage to telecommunications plant Almost always result from HV phase – earth fault Maximum impressed voltage readily calculated prior to construction Consequences major (danger) Hence ‘predictive’ approach

Key Impacts (cont.) Noise interference Arises from ‘normal’ power network operation (not faults) Maximum impressed voltage very difficult to predict Causes mal-operation of signalling systems, degradation of call quality (unusable?), slowing down of available broadband speed

Consequences more minor (nuisance) Rarely a problem Hence ‘reactive’ approach

Key Power Co-ordination Aspects of Power Networks General The portion of the earth return current flowing through the soil is the key factor for both EPR and induced voltage hazards If no voltage is impressed onto telecommunications conductors, there is no problem

Size of Power Earthing System

Urban Extensive interbonded MEN systems in urban areas greatly limit EPR magnitude. They do not cause hazard problems. Can still have EPR hazard from conductive HV power poles and other power earthing systems, that are NOT bonded to extensive interbonded MEN systems. Induced voltage hazard rare in urban areas due to extensive ‘shielding’.

Rural Rural EPR levels are very high for HV earth faults

Rural (cont.) HV earth faults at rural distribution transformers are a particular concern. EPR typically > 3 kV is transferred onto LV MEN system. Mains-powered telecommunications equipment may suffer insulation breakdown (to remote earth on incoming telecommunications cable conductors).

Possible solutions: Separation of HV and LV earths at the distribution transformer. Petersen coil (or similar) at Zone Substation.

Key Power Co-ordination Aspects of Telecommunications Networks Insulated copper conductor multi twisted pair telecommunications cables All ‘working pairs’ have a (remote) earth reference provided by the Telephone Exchange earth. Mains-powered customer’s telecommunications equipment which bridges the power and telecommunication networks is increasingly common.

Typical copper conductor sizes are 0. 4 mm and 0. 63 mm diameter (0 Typical copper conductor sizes are 0.4 mm and 0.63 mm diameter (0.13 mm2 and 0.31 mm2). Individual plastic insulated copper conductors in telecommunications cables (since 1970) have been spark tested during manufacture to 1.4 kVrms.

Typical Insulation Levels Telecommunications Plant Insulation (kV) Installed Buried cables with paper insulated conductors (PCUT, PCUB, PCQL) 1.0 Before 1970 Buried cables with plastic insulated conductors - not grease filled or pressurised (PEUT) 1.5 1970 - 1975 Pillars, pedestals, OJs 1970 - Buried grease filled or pressurised cables with plastic insulated conductors (PEFUT, PEUB, CPUB) 2.5 1975 - As above, but installed in the ground in pipe 4.0

Telecommunications Industry Mitigation Options EPR Hazard Shift telecommunications plant to lower EPR area Replace network plant (e.g. cables) with plant with a higher insulation rating Shift locally earthed network plant Install isolation units at customer’s premises

Replace copper cable network plant with fibre optic cables Special safety practices for telecommunications staff

Induced Voltage Hazard Reroute parallel telecommunications cables to: Reduce length of parallel Increase separation Install fibre optic cable to roadside electronic cabinet Reduces parallel to 1/3 of former length

Fibre Optic Cable Networks Minimal or nil Power Co-ordination impacts UFB rollout in urban areas is due to be completed in 2020 However, retirement of urban copper telecommunication cable networks could easily be 10 or more years later

Metallic moisture barrier Minor Power Co-ordination issues still apply if the fibre optic cables contain any metallic parts e.g. Steel strength member Metallic moisture barrier Copper tracer wire (for future cable location) Metal catenary wire (aerial f/o cables) (Ref. PCOG 4.5, 12.2.3)