21 April 2004LCWS 2004 Paris1 Readout of a TPC using the Medipix2 CMOS pixel sensor (detection of single electrons on a direct pixel segmented anode) NIKHEF:

Slides:



Advertisements
Similar presentations
General Characteristics of Gas Detectors
Advertisements

Detector R&D Jan Timmermans Programme: ≥ 2003
Amsterdam, March 31, 2003 P. Colas - European R&D for gaseous trackers 1 European gaseous tracking hardware HistoryHistory GEM and MicromegasGEM and Micromegas.
M. Chefdeville NIKHEF, Amsterdam MPGD, Hawaii 07
Amsterdam, April 2,2003P. Colas - Micromegas TPC1 Micromegas TPC: New Results and Prospects New tests in magnetic fieldNew tests in magnetic field FeedbackFeedback.
Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
3-D simulation of Si-Prot Charge distribution, signal development D. Attié, P. Colas, E. Delagnes, S. Turnbull - Introduction - Orders of magnitude - Simulation.
GEM Detector Shoji Uno KEK. 2 Wire Chamber Detector for charged tracks Popular detector in the particle physics, like a Belle-CDC Simple structure using.
1 Pixel Readout of GEMs Motivation The Setup Results Next Steps A. Bamberger, K. Desch, J. Ludwig, M. Titov, U. Renz, N. Vlasov, P. Wienemann, A. Zwerger.
D. Peterson, “The Cornell/Purdue TPC”, LCWS05, Stanford, 21-March The Cornell/Purdue TPC Information available at the web site:
UTA, Jan. 9-11, 2003M. Ronan LC-TPC R&D1 LC-TPC R&D GEM, MicroMEGAS and MWPC techniquesGEM, MicroMEGAS and MWPC techniques Preliminary studiesPreliminary.
Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.
Readout of a TPC with the MEDIPIX2 CMOS chip as direct anode Saclay/DapniaP. Colas Y. Giomataris NIKHEFA. Fornaini H. van der Graaf J. Timmermans J. Visschers.
Kolympari, Crete, June 16, Study of avalanche fluctuations and energy resolution with an InGrid-TimePix detector P. Colas Progress report, based.
New Developments in Gaseous Tracking and Imaging Detectors Harry van der Graaf Nikhef, Amsterdam on behalf of the GridPix/Gossip group IWORID 2008 Helsinki.
Carleton University A. Bellerive, K. Boudjemline, R. Carnegie, A. Kochermin, J. Miyamoto, E. Neuheimer, E. Rollin & K. Sachs University of Montreal J.-P.
ECFA Meeting, Valencia – November 8, First TimePix tests at CERN David Attié ECFA Meeting – Valencia – 8 November 2006.
1 Pixel readout for a TPC LCWS 2010 – Tracking TPC R&D session 27 March 2010 Jan Timmermans On behalf of the Bonn/CERN/Freiburg/Nikhef/Saclay groups.
Timepix-3 test All-ceramic InGrid The focusing TPC
GOSSIP : Gas On Slimmed SIlicon Pixels NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay.
Detector Research & Development RECFA, NIKHEF, Amsterdam. Sept 23, 2005 Harry van der Graaf, NIKHEF, Amsterdam.
Annual Meeting 2008 – October 6 th 1 David Attié P. Colas, X. Coppolani, E. Delagnes, A. Giganon, I. Giomataris Status of Saclay.
Stanford, Mar 21, 2005P. Colas - Micromegas TPC1 Results from a Micromegas TPC Cosmic Ray Test Berkeley-Orsay-Saclay Progress Report Reminder: the Berkeley-Orsay-
Orsay, January 12, 2005P. Colas - Resistive anode Micromegas1 Dan Burke 1, P. Colas 2, M. Dixit 1, I. Giomataris 2, V. Lepeltier 3, A. Rankin 1, K. Sachs.
GOSSIP a new vertex detector for ATLAS Harry van der Graaf NIKHEF, Amsterdam Univ. of Bonn, Nov 23, 2006.
An Integrated Single Electron Readout System for the TESLA TPC Ton Boerkamp Alessandro Fornaini Wim Gotink Harry van der Graaf Dimitri John Joop Rovekamp.
Micropattern on CMOS pixels NIKHEFMaximilien Chefdeville Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers.
The detection of single electrons using the MediPix2/Micromegas assembly as direct pixel segmented anode NIKHEF: A. Fornaini, H. van der Graaf, P. Kluit,
Beijing, Feb.6, 2007 P. Colas - Micromegas TPC 1 Micromegas TPC studies in a 5 Tesla magnetic field with a resistive readout D. Attié, A. Bellerive, K.
Micromegas TPC Beam Test Result H.Kuroiwa (Hiroshima Univ.) Collaboration with Saclay, Orsay, Carlton, MPI, DESY, MSU, KEK, Tsukuba U, TUAT, Kogakuin U,
Timepix at NIKHEFMedipix meeting, CERN – Some recents results at NIKHEF M. Chefdeville, E. Bilevych, H. van de Graaf, J. Timmermans D. Attié,
The Gossip gaseous detector for the ATLAS Upgraded ‘SC’T Harry van der Graaf Nikhef, Amsterdam on behalf of the GridPix/Gossip group ATLAS Tracker Upgrade.
LC TPC R&D Results May Selected LC TPC R&D Results for the DESY RPC Meeting 2003 May 07 The LC TPC R&D Groups of the PRC R&D-01/03 Proposal Carleton,
1 Readout of a TPC by Means of the MediPix CMOS Pixel Sensor NIKHEFAuke-Pieter Colijn Arno Aarts Alessandro Fornaini Maximilien Chefdeville Harry van der.
23 March 2005International TPC R&D Meeting Berkeley 1 Readout of a TPC using the Medipix2 CMOS pixel sensor (detection of single electrons on a direct.
GEM basic test and R&D plan Takuya Yamamoto ( Saga Univ. )
GOSSIP & the ATLAS SCT Upgrade Max Chefdeville NIKHEF, Amsterdam ATLAS Upgrade Workshop CERN, Oct 1, 2006.
1 InGrid: the integration of a grid onto a pixel anode by means of Wafer Post Processing technology 16 April 2008 Victor M. Blanco Carballo.
GOSSIP : a vertex detector combining a thin gas layer as signal generator with a CMOS readout pixel array Gas On Slimmed SIlicon Pixels.
you me  when it all started to work  progress made  outlook.
1 Update on Silicon Pixel Readout for a TPC at NIKHEF LCWS08 - Chicago 19 Nov 2008 Jan Timmermans NIKHEF.
Snowmass, August, 2005P. Colas - InGrid1 M. Chefdeville a, P. Colas b, Y. Giomataris b, H. van der Graaf a, E.H.M.Heijne c, S.van der Putten a, C. Salm.
1 Status ‘Si readout’ TPC at NIKHEF NIKHEFMaximilien Chefdeville Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans.
1 The pixel readout of TPCs Max Chefdeville, NIKHEF, Amsterdam.
Vienna, Feb. 17, 2004P. Colas - Micromegas TPC1 First test of a Micromegas TPC in a magnetic field Advantages of a Micromegas TPC for the Linear ColliderAdvantages.
LCTPC meeting, Feb. 11, 2004P. Colas - Micromegas TPC1 Status report of Berkeley- Orsay-Saclay Since Montpellier, we took data with magnetic field, with.
New gaseous detectors: the application of pixel sensors as direct anode NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan.
Micromegas (Ingrid)+TimePix 8-chip modules
EUDET Meeting, Munich – October 18, Ongoing activities at Saclay David Attié D. Burke; P. Colas; E. Delagnes; A. Giganon; Y. Giomataris;
November 8, 2006ECFA ILC Workshop1 Recent developments for digital TPC readout Jan Timmermans - NIKHEF Micro Pattern Gas Detector: GridPix Integration.
GEM+Timepix2 in the framework of project Gabriele Croci, Matteo Alfonsi on behalf of CERN-GDD Group RD51 Miniweek, February 2010.
1 The Silicon TPC System EUDET Extended SC meeting 27 August 2007 Jan Timmermans NIKHEF.
LCWS Bangalore, March 13, 2006 P. Colas, Digital TPC R&D1 R&D for a digital TPC The SiTPC project The digital TPC concept and advantages VLSI electronics:
IEEE/NSS Oct 22, Electron Counting and Energy Resolution Study from X-ray conversion in Argon Mixtures with an InGrid-TimePix detector. D. ATTIÉ.
Status report NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA DAPNIAMaximilien.
The digital TPC: the ultimate resolution P. Colas GridPix: integrated Timepix chips with a Micromegas mesh.
Development of a Front-end Pixel Chip for Readout of Micro-Pattern Gas Detectors. Vladimir Gromov, Ruud Kluit, Harry van der Graaf. NIKHEF, Amsterdam,
Detector R & D Harry van der Graaf NIKHEF Jamboree Dec 19, 2006.
Timepix in EUDet – CERN contribution Michael Campbell PH Department CERN Geneva, Switzerland Spokesman, Medipix2 Collaboration.
Durham, Sep 3, 2004P. Colas - Micromegas TPC1 Micromegas TPC Berkeley-Orsay-Saclay Progress Report Reminder: the Berkeley-Orsay- Saclay cosmic setupReminder:
On behalf of the LCTPC collaboration -Uwe Renz- University of Freiburg Albert-Ludwigs- University Freiburg Physics Department.
Vienna Conference on Instrumentation – February 27, D. Attié, A. Bellerive, K. Boudjemline, P. Colas, M. Dixit, A. Giganon,
Grid Pix Field Simulations and precision needed for a module Peter Kluit, Jan Timmermans Prepared 16 May 2016.
Gossip : Gaseous Pixels Els Koffeman (Nikhef/UvA) (Harry van der Graaf, Jan Timmermans, Jan Visschers, Maximilien Chefdeville, Vladimir Gromov, Ruud Kluit,
GOSSIP : a vertex detector combining a thin gas layer as signal generator with a CMOS readout pixel array NIKHEFAuke-Pieter Colijn Alessandro Fornaini.
TPC for 4-th concept S.Popescu IFIN-HH, Bucharest.
Experience from ZEUS Microvertex detector is running for more than five years without access! E.N Koffeman NIKHEF & University of Amsterdam.
TPC Paul Colas Technical meeting, Lyon.
R&D for a digital TPC The SiTPC project
TPC chamber for Medipix2/TimePix
Presentation transcript:

21 April 2004LCWS 2004 Paris1 Readout of a TPC using the Medipix2 CMOS pixel sensor (detection of single electrons on a direct pixel segmented anode) NIKHEF: Alessandro Fornaini Univ. Twente/Mesa+: Harry van der Graaf Jurriaan Schmitz Jan Timmermans CERN/Medipix Collaboration: Jan Visschers Erik Heijne Peter Kluit Saclay Paul Colas Thanks to: Wim Gotink (CEA/DAPNIA) Ioannis Giomataris Joop Rovenkamp Arnaud Giganon Max Chefdeville

21 April 2004LCWS 2004 Paris2 Goals Gas multiplication GEM or Micromegas foil(s) Charge collection with granularity matching primary ionisation cluster spread Needs sufficiently low diffusion gas dE/dx using cluster counting? (  M. Hauschild) Proof of principle based on existing Medipix2 readout chip

21 April 2004LCWS 2004 Paris3 Our GEM-equipped TPC We have constructed a small test TPC equipped with three GEM foils which can be read out by means of the MEDIPIX2 CMOS pixel sensor. MEDIPIX2 The GEM foils were obtained from the CERN/Sauli/GEM group; hole-to-hole distance (hexagonal geometry): 140 µm, hole diameter 85 µm, fiducial surface 100 mm x 100 mm, thickness 50 µm. The drift volume (vol. 100x100x100 mm 3 ) is surrounded by square wire loops, spaced 6.3 mm, put at decreasing potential. Three GEM foils are placed 7.4 mm behind the plane of the bottom wire loop; the distance between GEM foils is 1.6 mm. The anode plane, at ground potential, is 6.6 mm below the third GEM foil.

21 April 2004LCWS 2004 Paris4 Drift Space GEM foils MediPix CMOS pixel sensor Brass spacer block Printed circuit board Aluminium base plate Medipix2: 256 x 256 pixels 55 mm x 55 mm area 14 x 14 mm 2 each pixel: low-noise preamp, discriminator, two threshold DAC, 13-bit counter, communication logic Drift length: 100 mm Distance between GEMs: 1.6/2.6 mm Distance bottom GEM/MEDIPIX: 6.6 mm

21 April 2004LCWS 2004 Paris5 Top Drifter 5700 V Bottom Drifter 3473 V Top GEM V Bottom GEM V Top GEM V Bottom GEM V Top GEM V Bottom GEM V In the base plate of the chamber, a hole was cut out for the MEDIPIX2 chip: its pixel surface was flush with the (anode plane) base plate plane. The MEDIPIX2 chip contains 256 x 256 square pixels with pitch 55 µm x 55 µm giving a total fiducial sensitive area of mm x mm. Each pixel is equipped with a low-noise charge preamp, discriminator, two threshold DACs, a 13-bit counter and communication logic. Since a triggering system had not been implemented, we operated the MEDIPIX2 sensor by enabling the counters manually, and stop the counting after a pre-set time interval ( s). After that, the counts of each pixel are read out. Drift length: 100 mm Distance between GEMs: 1.6/2.6 mm Distance bottom GEM/MEDIPIX: 6.6 mm

21 April 2004LCWS 2004 Paris6 First events, recorded on March 29, Drift space irradiated with 55 Fe quanta Not immediately understood. Now we do: conversion source ~0.3 mm, defocussing GEM ~0.5 mm, diffusion in driftspace ~1.5 mm Ar/CH 4 90/10

21 April 2004LCWS 2004 Paris7 No source; exposed 0.01 sNo source; exposed 2 s No source; exposed 0.1 s 90 Sr source; exposed 0.01 s Fiducial field: 14 x 14 mm 2 Collected ionisation in 14 x 14 x 100 mm 3 during exposure time Feb 9, 2004 Ar/Isobutane 95/5

21 April 2004LCWS 2004 Paris8 MediPix2 pixel sensor Brass spacer block Printed circuit board Aluminum base plate Micromegas Cathode (drift) plane 55 Fe Baseplate Drift space: 15 mm With Paul Colas & Ioannis Giomataris: MediPix2 & Micromegas Very strong E-field above (CMOS) MediPix!

21 April 2004LCWS 2004 Paris9 MediPix modified by MESA+, Univ. of Twente, The Netherlands Pixel Pitch: 55 x 55 μm 2 Bump Bond pad: 25 μm octagonal 75 % surface: passivation SiN New Pixel Pad: 45 x 45 μm 2 Insulating surface was 75 % Reduced to 20 %

21 April 2004LCWS 2004 Paris10

21 April 2004LCWS 2004 Paris11

21 April 2004LCWS 2004 Paris12 We always knew, but never saw: the conversion of 55 Fe quanta in Ar gas No source, 1s 55 Fe, 1s 55 Fe, 10s Friday 13 (!) Feb 2004: signals from a 55 Fe source (220 e- per photon); 300  m x 500  m clouds as expected 14 mm The Medipix CMOS chip faces an electric field of 350 V/50 μm = 7 kV/mm !! Ar/Isobutane 95/5

21 April 2004LCWS 2004 Paris13 New trial: NIKHEF, March 30 – April 2 Essential: try to see single electrons from cosmic muons (MIPs) Pixel preamp threshold: 3000 e- Required gain: 5000 – New Medipix New Micromegas Gas: He/Isobutane 80/20 Ar/Isobutane 80/20 He/CF4 80/20 …… It Works!

21 April 2004LCWS 2004 Paris14 Eff = e -n/G n: threshold setting (#e-) G: Gas amplification Prob(n) = 1/G. e -n/G

21 April 2004LCWS 2004 Paris15 He/Isobutane 80/20 Modified MediPix 30 March 2004

21 April 2004LCWS 2004 Paris16 He/Isobutane 80/20 Modified MediPix 30 March 2004

21 April 2004LCWS 2004 Paris17 He/Isobutane 80/20 Modified MediPix 30 March 2004

21 April 2004LCWS 2004 Paris18 He/Isobutane 80/20 Non Modified MediPix Amaricium Source 1 April 2004

21 April 2004LCWS 2004 Paris19 He/Isobutane 80/20 Modified MediPix 30 March 2004

21 April 2004LCWS 2004 Paris20 He/Isobutane 80/20 Modified MediPix 30 March 2004