Data Analysis and Presentation Chapter 5- Calibration Methods and Quality Assurance EXCEL – How To Do 1- least squares and linear calibration curve/function.

Slides:



Advertisements
Similar presentations
Calibration Techniques
Advertisements

Primary Standards Is a highly purified compound that serves as a reference material in all volumetric and titrimetric methods. It must be: –1) Highly pure,
Instrumental Analysis
CHEM 213 Instrumental Analysis Lab Lecture – Copper by AA & Least Squares Analysis.
Chapter 7 Statistical Data Treatment and Evaluation
CHEMISTRY ANALYTICAL CHEMISTRY Fall
Stoichiometry Chapter 5. Stoichiometry Quantitative relationships between reactants and products The balanced chemical equation gives us the relationships.
Result validation. Exercise 1 You’ve done an analysis to the best of your ability using the correct procedure. Is your answer correct? possibly, hopefully.
Calibration Methods Introduction
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Chapter 1 Introduction Analytical Chemistry deals with methods for determining the chemical composition of samples. Qualitative Analysis (identification)
ANALYTICAL CHEMISTRY ERT 207
AOSC 634 Air Sampling and Analysis Lecture 1 Measurement Theory Performance Characteristics of instruments Nomenclature and static response Copyright Brock.
Summary 1 l The Analytical Problem l Data Handling.
Basic Questions Regarding All Analytical & Instrumental Methods (p 17-18) What accuracy and precision are required? How much sample do I have available,
Chapters 3 Uncertainty January 30, 2007 Lec_3.
Lecture 3 Calibration and Standards. The points (1,2) and (6,5) do not fall exactly on the solid line, but they are too close to the line to show their.
Homework Chapter 0 - 0, 1, 2, 4 Chapter 1 – 15, 16, 19, 20, 29, 31, 34.
Data Handling l Classification of Errors v Systematic v Random.
We are not going to do Ch 29.2: Method Validation Seminar today CHE 315 – Lecture 9 9/19/05.
Analytical Chemistry Definition: the science of extraction, identification, and quantitation of an unknown sample. Example Applications: Human Genome Project.
03 - CONCENTRATION - DILUTIONS CHEMISTRY 30 – UNIT 2 – SOLUBILITY – CH. 16 IN TEXT.
Chem. 31 – 2/18 Lecture. Announcements Turn in AP1.2 Quiz today Exam 1 coming up (1 week from next Monday) Today’s Lecture –Chapter 4 Material Calibration.
CALIBRATION METHODS.
Chem. 31 – 2/2 Lecture. Announcements Due Wednesday –Turn in corrected diagnostic quiz –HW Set 1.1 – just additional problem Quiz on Wednesday (covering.
Calibration & Curve Fitting
Determination of Iron in Water
Data Analysis and Presentation
Analyzing Data Chapter 2.
Determination of Iron in Water
Physics 114: Lecture 15 Probability Tests & Linear Fitting Dale E. Gary NJIT Physics Department.
Errors and Uncertainties © Christopher Talbot and Cesar Reyes 2008
Quality assurance of sampling and analytical instruments
Lesson Starter Look at the specifications for electronic balances. How do the instruments vary in precision? Discuss using a beaker to measure volume versus.
Chem. 31 – 9/23 Lecture Guest Lecture Dr. Roy Dixon.
Bias and Errors. Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness.
Quality Control Lecture 5
Objectives Distinguish between accuracy and precision. Determine the number of significant figures in measurements. Perform mathematical operations involving.
Spectrophotometry: An Analytical Tool
Data Analysis and Presentation Chapter 5- Calibration Methods and Quality Assurance EXCEL – How To Do 1- least squares and linear calibration curve/function.
Analytical Chemistry Definition: the science of extraction, identification, and quantitation of an unknown sample. Example Applications: Human Genome Project.
Quality Assurance How do you know your results are correct? How confident are you?
Chapter 8: Sampling, Standardization & Calibration
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
CALIBRATION METHODS. For many analytical techniques, we need to evaluate the response of the unknown sample against the responses of a set of standards.
CHEMISTRY ANALYTICAL CHEMISTRY Fall Lecture 6.
Preview Lesson Starter Objectives Accuracy and Precision Significant Figures Scientific Notation Using Sample Problems Direct Proportions Inverse Proportions.
Analytical Chemistry Definition: the science of extraction, identification, and quantitation of an unknown sample. Example Applications: Human Genome Project.
7 장 적정 Stirring bar One method in volumetric analysis is titration In titration: - substance to be analysed is known as the analyte - the solution added.
IH&S 725 Dr. Myers, C.I.H. Quality assurance of sampling and analytical instruments Lecture Notes.
Interferences. Matrix interference the matrix is the major component of the sample can affect the measured analyte response Response = constant x concentration.
Chapter 1: Introduction Analytical Chemistry Analytical Chemistry Qualitative analysis Qualitative analysis Quantitative analysis Quantitative analysis.
Quality Control Internal QC External QC. -Monitors a test's method precision and analytical bias. -Preparation of quality control samples and their interpretation.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Chapter 1: The Nature of Analytical Chemistry
Instrumental Analysis
Chem. 31 – 6/13 Lecture. Announcements I Pipet and Buret Calibration Lab Report Due Quiz and Homework Returned in Lab Exam 1 on Thursday –Will cover material.
Chapter 5 Quality Assurance and
Solution Concentration.  Lesson Objectives  Describe the concept of concentration as it applies to solutions, and explain how concentration can be increased.
Instrumental Analysis Ion selective electrodes
Art PowerPoints Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS.
The standard deviation (SD) quantifies variability
Internal Standard method (experiment lab-4)
Chem. 31 – 9/25 Lecture.
iCAP OES Analysis of Trace Elements in Hair
Analysis of Iron Experiments 3, 19 & 20.
Absorption Spectroscopy
Chapter 2 Table of Contents Section 1 Scientific Method
Chapter 5 Quality Assurance and Calibration Methods
Presentation transcript:

Data Analysis and Presentation Chapter 5- Calibration Methods and Quality Assurance EXCEL – How To Do 1- least squares and linear calibration curve/function (chapter 4) 2- standard addition (chapter 5) 3-internal standard (addition) (chapter 5)

External standard 1- least squares and linear calibration curve/function (chapter 4)

CHAPTER 05: Opener B

CHAPTER 05: Table 5.1

Calibration function Q: How the selected instrument responds to the change in quantity (concentration, M ppm ) of the measured analyte? A: Measure the instrument responses (peak hights, peak areas etc.) from known but different concentrations of the analyte (say 0, 5,10, ppm standards). Then construct the response diagram figure (response vs. concentration) with the response or calibration function through the points.

Calibration Data: Answer 2 GO TO EXCELL or your calculator

MFYI: Method of Least Squares/Linear regression The method of least squares assumes that the errors in the y values are substantially greater than the errors in the x values. A second assumption is that the uncertainties in all of the y values are similar. Derivation of the Least Squares Method (Equation for a straight line)y = mx + b Vvertical deviation = di i = yi–y = yi–(mxi+b) SSome of the deviations are positive and some are negative. To minimize the magnitude of the deviations irrespective of their signs, we square the deviations to create positive numbers.

If one assumes that the calibration curve is linear – there are physical reasons for that. There is a linear function that can best represent the response of the instrument. If points are out of line: error There are methods based on the propagation of error that can help us calculate the best fit: linear regression of the straight-line calibration curves OLD SLIDE: Caffeine again: first step calibration

CALIBRATION: Instrument used to measure signals must be calibrated, must have the calibration relation. Example (linear): y = m [x ]+ b (general algebraic form for linear equation) Often given in other similar forms: S measured (total signal) =k n A (concentration) + S reag ( signal from reagents, from blank) Calibration is the determination of that relation: it is used for the determination of analyte by using standards and blanks to determine a relationship (function) between concentrations and assay responses. Validation implies that other labs have approved the analytical method of analysis and produced similar results. Standards are materials containing accurately known concentrations of the desired analyte. Standardization is the process of determining relationship between the measured signal and the amount of analyte (fittting for k in linear relations). Blanks are solutions containing all added reagents except the sample analyte.(method, reagent and field blanks) Controls can be an alternate sample, in which the contents are well known. Primary and Secondary reagents

Calibration Data: Answer 2 GO TO EXCELL or your calculator

CHAPTER 04: Unnumbered Table 4.3

CHAPTER 04: Unnumbered Table 4.4

CHAPTER 04: Figure 4.12

CHAPTER 04: Figure 4.14

IMPORTANT : BLANK !! Before you start measuring standards, you need to see the signal from a sample without analyze. BLANK: everything but analyte

CHAPTER 04: Table 4.7

EXAMPLE: CORRECTION FOR nonzero BLANK Your blank is (for zero concentration of analyte) Your signals are as follows Signal Corrected signal for blank (!) concentration —

2- standard addition (chapter 5)

Is such external standardization the only way to calibrate and acquire the accurate and precise values? No, there are also other methods that include addition of analyte or some other material into the sample (aliquot)

Possible problems with external standardization

Spike Sometimes (often) the response to analyte is affected by something else in the sample, which we call MATRIX. SPIKE is a known quantity of analyte added directly to the sample to verify if the response to analyte is the same as that expected from pure sample observed in the calibration curve.

2. Standard addition SStandard addition: Known quantities of analyte are added to the unknown, and the increased signal lets us deduce how much analyte was in the original unknown. Typically we use the method of standard addition when unknown sample matrix is sufficiently complex. The blank and standards are not representative of the unknown sample and lead to analysis error. This method requires a linear response to analyte. For a single spike, one trial [X] i / [X] f + [S] f = I x / I s+x [X] i = unknown initial concentration of analyte I x = signal from first solution [S] f = concentration of standard in second solution [X] f = diluted concentration of analyte I s+x = signal from second solution

CHAPTER 05: Equation 5.7

EExample 2 A blood serum sample containing sodium ion gives a signal of 4.27 mV on a light intensity meter in an atomic emission experiment. The Na + concentration in the serum is then increased by M by a standard addition, without significantly diluting the sample. This "spiked" serum sample gives a signal of 7.98 mV in atomic emission. Find the original concentration of Na + in the serum. [X] i = unknown initial concentration of Na + I x = 4.27 mV [S] f = M [X] f = diluted concentration of analyte = [X] i I s+x = 7.98 mV [X] i = M

FYI: (2) Sample  direct addition ab S sample = S spike a b

(1)Sample  separate aliquots (portions) a b S sample = S spike a b FYI: Accurate description S sample = signal sample C S = concentration spiked C A = concentration analyte

WWe use standard addition methods when our sample has matrix effects which are hard to duplicate in a blank. Let's again find the amount of Pb +2 in a blood sample. A 5.00 mL blood sample containing lead yielded a signal of units. Afterwards, the sample was spiked with 5.00  L of 1560 ppb Pb +2 standard. (note: a small addition) This spiked solution gave a reading of units. Find the concentration of Pb +2. [X] i / [X] f + [S] f = I x / I s+x or [C] i / [C] f + [Cs] f = S x / S s+x Be careful with volume! Example 3. C A =1.33ppb

3. Internal Standard In addition to the analyte you measure add another similar compound (not analyte ) that has similar response ( sensitivity ) as the analyte.

Internal Standard is sometimes added to an unknown sample. The reason may be to verify the signal response in situations where instrument response varies slightly from run to run. For example, an analysis is preformed on different days or different instruments or under different operating conditions. Typically, the internal standard resembles the analyte. Let's say we are separating isomers of octane and determining their concentration on a gas chromatograph (GC). To verify how much is present we might add a known amount of cyclohexane as an internal standard

Internal Standard An internal standard is a known amount of a compound, different from the analyte, that is added to the unknown sample. A Standard mixture of analyte and standard is prepared before hand. Internal standards are desirable whenever losses of sample are likely to occur during handling or analysis. They are also used to calibrate the instrument when same analysis is done on different days. Use the following relation:

Internal Standard SA(signal due to analyte) =k A CA SIS(signal due to int. stand) =k IS CIS

CHAPTER 05: Equation 5.11

Example Example on internal standard: Note we are not diluting the sample significantly! A lab uses Cu +2 as a internal standard for a Pb +2 analysis in blood. Known solution standards for Pb +2 (1.75 ppm) and Cu +2 (2.25 ppm) give readings such that the signal ratio of Pb to Cu is A blood sample was spiked with the Cu standard (2.25 ppm). We assume that the blood sample volume does not change significantly. The ratio of the readings for Pb to Cu in the unknown spiked solution is Based on the response for the known amount of Cu +2 added to a blood sample determine, the amount of Pb +2 present. S A (signal due to analyte) = k A C A S IS (signal due to int. stand) = k IS C IS CACA C IS = K K=3.05 C A =1.33ppb Pb 2+ CA=CA= C IS SASA S IS K First measurement Second measurement