(Analog) Data Acquisition D. Gordon E. Robertson, PhD, FCSB.

Slides:



Advertisements
Similar presentations
Analog Representations of Sound Magnified phonograph grooves, viewed from above: When viewed from the side, channel 1 goes up and down, and channel 2 goes.
Advertisements

Analog-to-Digital Converter (ADC) And
Lock-in amplifiers Signals and noise Frequency dependence of noise Low frequency ~ 1 / f –example: temperature (0.1 Hz), pressure.
ECE 265 – LECTURE 14 Analog Signal Acquisition The A/D converters 5/14/ ECE265.
4-Integrating Peripherals in Embedded Systems (cont.)
Data Acquisition Risanuri Hidayat.
Data Acquisition Concepts Data Translation, Inc. Basics of Data Acquisition.
Presented by- Md. Bashir Uddin Roll: Dept. of BME KUET, Khulna-9203.
Analog Sensing 101 WITH P Agenda  Analog Signal Characteristics  Common Problems with A/D Conversion  Clipping  Small Signals  Aliasing  Analog.
Instrumentation - Introduction 10/9/2013Ohio University - Dr. Cyders1 Engineering measurements are usually taken by some form of transducer. A transducer.
Analog Data Processing with BioProc3 Part Two EMG Analysis Techniques.
Interfacing Analog and Digital Circuits
Data Acquisition Systems ACES Presentation Brad Ellison March 11, 2003.
CSE466 Autumn ‘00- 1 System Functional Requirements  Children’s toy…comes with PC software. Child plays notes on the screen and the device makes corresponding.
Objectives: Sampling of analog signal. Act as analyzer and terminal for pc. Project supervised by: Michael Gandelsman Project performed by: Roman Paleria,
Data Acquisition. Data Acquisition System Analog Signal Signal Conditioner ADC Digital Processing Communication.
 Principles of Digital Audio. Analog Audio  3 Characteristics of analog audio signals: 1. Continuous signal – single repetitive waveform 2. Infinite.
Electromyography: Recording D. Gordon E. Robertson, Ph.D. Biomechanics Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
Digital to Analogue Conversion Natural signals tend to be analogue Need to convert to digital.
11 Lecture Slides ME 3222 Kinematics and Control Lab Lab 2 AD DA and Sampling Theory By Dr. Debao Zhou.
Tone Control (Filters).
Presented by Emil Melamed
Computer Based Data Acquisition Basics. Outline Basics of data acquisition Analog to Digital Conversion –Quantization –Aliasing.
Ni.com Data Analysis: Time and Frequency Domain. ni.com Typical Data Acquisition System.
DSP Techniques for Software Radio DSP Front End Processing Dr. Jamil Ahmad.
Data Converters ELEC 330 Digital Systems Engineering Dr. Ron Hayne
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
Simple Data Type Representation and conversion of numbers
Granular Systems in Microgravity Michael L. Wilson The University of Tulsa Supported by Research Corporation.
POWER SUPPLIES. The Power Supply A station’s power supply (sometimes known as a power supply unit or PSU) is a device or system that supplies electrical.
1 4-Integrating Peripherals in Embedded Systems (cont.)
Computer Some basic concepts. Binary number Why binary? Look at a decimal number: 3511 Look at a binary number: 1011 counting decimal binary
Computing Systems Basic arithmetic for computers.
Data Acquisition Systems
ISAT 300 Computer-Based Instrumentation (part 2) Sampling and A/D Converters 11/14/01.
SCAD 508 Strain Measurement System Click Here To Download Complete Information On SCAD Products EXCITATION VOLTAGESelectable from 0.5VDC to 10 VDC in steps.
Signals and Systems Prof. Brian L. Evans Dept. of Electrical and Computer Engineering The University of Texas at Austin EE 382C-9 Embedded Software Systems.
Number Representation
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
V. Rouillard  Introduction to measurement and statistical analysis DIGITAL SAMPLING - DIGITISATION Digital sampling is mainly used in data acquisition.
˜ SuperHeterodyne Rx ECE 4710: Lecture #18 fc + fLO fc – fLO -fc + fLO
Engineering H192 - Computer Programming Gateway Engineering Education Coalition Lab 1P. 1Winter Quarter Data Acquisition System Fundamentals Lab 1.
Audio Systems. Introduction Audio systems are designed to give an output frequency within the audible range for a human being (20 Hz to 20KHz). Below.
1 Information Representation in Computer Lecture Nine.
16722 Mo: data acquisition150+1 data acquisition.
COMPANDING - is the process of compressing and then expanding
Fundamentals of Audio Production. Chapter 3 1 Fundamentals of Audio Production Chapter Three: Digital Audio.
Audio sampling as an example of analogue to digital Mr S McIntosh.
Software Design and Development Storing Data Computing Science.
Real time DSP Professors: Eng. Diego Barral Eng. Mariano Llamedo Soria Julian Bruno.
Basics of Bypass Capacitor, Its Functions and Applications.
MECH 373 Instrumentation and Measurements
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
Number Systems and Binary Arithmetic
Data Acquisition System
Preamplifier and mixers, Power Amplifiers, and Speakers
Data Acquisition Systems
Lock-in amplifiers
Planning Experiments & Measurements
Introduction to data converters
Introduction to data converters
Data Representation Keywords Sound
Digital Acquisition of Analog Signals – A Practical Guide
Signals and Systems Networks and Communication Department Chapter (1)
Lesson 12: Analog Signal Conditioning
Storing Negative Integers
EEG Probe Project Grant G. Connell.
IT11004: Data Representation and Organization
USB Project (22nd August)
Presentation transcript:

(Analog) Data Acquisition D. Gordon E. Robertson, PhD, FCSB

Issues What type of signal? (AC or DC) How many signals (channels) will be needed? Characteristics of signal (range, frequency) How does the A/D converter record the data? Is signal conditioning necessary? (amplification, filtering) How will the data be saved for use by other software?

What Kind of Signal? Use AC-coupling to remove biases from AC signals such as EMGs, EEGs or ECGs. Use DC-coupling for all other signals Piezoelectric signals, such as from accelerometers or force transducers, may require recording of bias levels for zeroing EMGs are AC Forces are DC

How Many Channels? A/D converters sample multiple signals one channel at a time. Typically 4, 8, 16, 32 or 64 channels are possible Note, the more channels that are sampled the lower the maximum sampling rate A/D converters have maximum rates (e.g., 100 kHz) that must be divided among the number of sampled channels Most systems sample all channels at the same rate. Some allow different rates for each channel. –1 Kistler force platform: 8 channels –1 AMTI force platform: 6 channels –1 3D head accelerometers: 9 channels –1 joint elgon: 1–3 channels NI 32-channel cDAQ A/D Biometrics 2-channel electrogoniometer AMTI force platform

Characteristics of Signal Voltage range: –0 to +5 V, 0 to +10 V –+/–1.5 V, +/–5 V, +/–10 V What is the signal’s frequency spectrum? –forces: DC to 10 Hz –audio: 20 Hz to 20 kHz –EMG: 20 to 500 Hz

What Signal Conditioning is Done? Amplification or attenuation to fit dynamic range of A/D converter –1000x for EMGs –force transducers 1/100, 1/10, 1/1 Analog filtering –band-pass filtering of EMGs Bortec 8-channel EMG, gains from 1x to 15000x Honeywell bridge amp

How does the A/D converter Record the Data? number of data bits: –8 bits gives 0 to 255 –12 bits gives 0 to 4095 –16 bits gives 0 to –24 bits gives 0 to over 1 million are the data stored in ones or twos complement or without sign bit bit formats: Intel, DEC, Sun software must be able to convert the integer data to floating point in volts or other measurement unit

Relationship between Integer and Real Data resolution = voltage range/bits for 12 bit, +/–10 V; resolution = 20/4096 = V/bit 8 bit 12 bit 16 bit+/–12 bit input V actual N 0 N –5000 N +10 V 0 V –10 V 2 16 – –

How Will the Data be Saved? integer format is the most compact and fastest integer format must be converted to floating point by other software (e.g., BioProc2/3, MATLAB, commercial software) real format (machine language) requires less processing but more memory ASCII requires greatest amount of memory but is easiest to read by other software (Excel, QuattroPro, SPSS) and may reduce accuracy due to rounding public format:.C3D,.WAV,.EDF,.WK1 spreadsheet:.WK1,.XLS,.QPW