Development of a Gamma-Ray Beam Profile Monitor for the High-Intensity Gamma-Ray Source Thomas Regier, Department of Physics and Engineering Physics University.

Slides:



Advertisements
Similar presentations
Digital Imaging with Charge- coupled devices (CCDs)
Advertisements

Area Detectors Like film can detect position Like scintillation detector can measure intensity With modern computers can assign hkl from unaligned crystal.
Advanced GAmma Tracking Array
Basic Principles of X-ray Source Detection Or Who Stole All Our Photons?.....
Entanglement and Bell’s Inequalities
Laser Anemometry P M V Subbarao Professor Mechanical Engineering Department Creation of A Picture of Complex Turbulent Flows…..
COMPUTER MODELING OF LASER SYSTEMS
Preliminary Performance Measurements for Streak Camera with Large-Format Direct-Coupled CCD Readout* 15th Topical Conference on High-Temperature Plasma.
Temperature Dependence of FPN in Logarithmic CMOS Image Sensors Dileepan Joseph¹ and Steve Collins² ¹University of Alberta, Canada ²University of Oxford,
Computed Tomography RAD309
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
GAMMA RAY SPECTROSCOPY
Beam Loss Analysis Tool for the CTF3 PETS Tank M. Velasco, T. Lefevre, R. Scheidegger, M. Wood, J. Hebden, G. Simpson Northwestern University, Evanston,
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
14.2 Data Capture Digital Imaging using CCDs. Capacitors  A capacitor is a device that stores charge.  Def’n of Capacitance - The ratio of the charge.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Fiber Optic Receiver A fiber optic receiver is an electro-optic device that accepts optical signals from an optical fiber and converts them into electrical.
Overview of Scientific Imaging using CCD Arrays Jaal Ghandhi Mechanical Engineering Univ. of Wisconsin-Madison.
Introduction to Machine Vision Systems
10/24/2005Zelimir Djurcic-PANIC05-Santa Fe Zelimir Djurcic Physics Department Columbia University Backgrounds in Backgrounds in neutrino appearance signal.
8/18/2015G.A. Fornaro Characterization of diffractive optical elements for improving the performance of an endoscopic TOF- PET detector head Student: G.
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
CLIC Collaboration Working Meeting: Work packages November 3, 2011 R&D on Detectors for CLIC Beam Monitoring at LBNL and UCSC/SCIPP Marco Battaglia.
Different sources of noise in EM-CCD cameras
Detecting Electrons: CCD vs Film Practical CryoEM Course July 26, 2005 Christopher Booth.
Live Cell Fluorescence Imaging Presented by: Nicholas Beavers – Media Cybernetics, Inc. Welcome to Sponsored by Starting Soon…
Photon detection Visible or near-visible wavelengths
Digital Photography A tool for Graphic Design Graphic Design: Digital Photography.
Abstract A time resolved radial profile neutron diagnostic is being designed for the National Spherical Torus Experiment (NSTX). The design goal is to.
DIGITAL RADIOGRAPHY DA 105.
Recent Progress in X-ray Emittance Diagnostics at SPring-8 S. Takano, M. Masaki, and H. Sumitomo * JASRI/SPring-8, Hyogo, Japan SES, Hyogo, Japan *
Scanning Electron Microscope (SEM)
Implementing a dual readout calorimeter in SLIC and testing Geant4 Physics Hans Wenzel Fermilab Friday, 2 nd October 2009 ALCPG 2009.
Measurement of Gas Bremsstrahlung at the Pohang Light Source Hyosang Lee Seoul National University, Q2C Pusan National University, HANUL HNP2011.
Compton/Linac based Polarized Positrons Source V. Yakimenko BNL IWLC2010, Geneva, October 18-22, 2010.
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
05/05/2004Cyrille Thomas DIAMOND Storage Ring Optical and X-ray Diagnostics.
Normalization of the NPDGamma Experimental Data F. Simmons, C. Crawford University of Kentucky, for the NPDGamma collaboration Background: NPDγ Experiment.
Objective Our goal is to create a radically inexpensive spectrometer for educational purposes using a Raspberry Pi. The prototype is housed in a black.
1 Energy loss correction for a crystal calorimeter He Miao Institute of High Energy Physics Beijing, P.R.China.
March 2004 Charles A. DiMarzio, Northeastern University ECEG287 Optical Detection Course Notes Part 15: Introduction to Array Detectors Profs.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Tests of spectrometer screens Introduction Layout Procedure Results Conclusions L. Deacon, B. Biskup, S. Mazzoni, M.Wing et. al. AWAKE collaboration meeting,
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 25 Digital Imaging.
Determining Radiation Intensity
Charge-Coupled Devices Astrophysics Lesson 5. Learning Objectives Describe and explain the structure and operation of the charge coupled device State.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
Beam Halo Monitoring using Optical Diagnostics Hao Zhang University of Maryland/University of Liverpool/Cockcroft Institute.
X-ray SNR in 3 steps. I ∆I. X-ray transmission SNR Review Let N = average number of transmitted x-rays N = N 0 exp [ - ∫  dz ] Emission and transmission.
CCD Image Processing: Issues & Solutions. CCDs: noise sources dark current –signal from unexposed CCD read noise –uncertainty in counting electrons in.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Taikan SUEHARA et al., LCWS2007 & DESY, 2007/06/01 R&D Status of ATF2 IP Beam Size Monitor (Shintake Monitor) Taikan SUEHARA, H.Yoda, M.Oroku,
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
AB/BI J. Koopman New WS design - Brain storm session 18/06/2007 1/16 New WS design - Brain storm session.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Digital Imaging Instead of Radiography.
Taikan SUEHARA, Joint Meeting of PRPPC in Honolulu, Hawaii, 2006/10/30 Laser Fringe Stabilization of 35nm IP Beam Size Monitor (Shintake monitor) for ATF2/ILC.
Digital Image -M.V.Ramachandranwww.youtube.com/postmanchandru
Semiconductor Detectors and Applications on X-ray imaging Natalie Diekmann Particle Physics 1 NIKHEF.
Working With Ratios & Proportions: Facilitating Scientific Thinking.
Laser wakefield accelerated electrons
A tool for Graphic Design
Summary of experience with Tevatron synchrotron light diagnostics
Impurity Transport Research at the HSX Stellarator
Basic Camera Function The camera converts an optical image into electrical signals that are reconverted by a television receiver into visible screen images.
כיצד נרכשת התמונה בסרט הרנטגני?
Photometric Analysis of Asteroids
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
A tool for Graphic Design
Photographic Image Formation I
Presentation transcript:

Development of a Gamma-Ray Beam Profile Monitor for the High-Intensity Gamma-Ray Source Thomas Regier, Department of Physics and Engineering Physics University of Saskatchewan

Beam Profile Monitor Component of Beam Diagnostic System Provides Gamma-Ray Position and Flux Information Assists users and operators in experiment and beam configuration

The High Intensity Gamma-Ray Source

270 MeV Linear Accelerator Electron Source Electron Storage Ring OK-5 Free Electron Laser RF Booster Experimental Area

Design Requirements Sub-millimeter resolution Easy to use Non-destructive Handle beam energies between 2 and 225 MeV Handle beam fluxes between 10 5 and gammas per second

Detecting Gamma-Rays

Design Concept  Gamma-Rays interact with the scintillator, generating flourescent illumination.  The illuminated scintillator is imaged onto a Charge Coupled Device by a lens system.  The CCD records the illumination pattern by converting the incident photons into electrons

System Model NCNC Relates the number of counts registered by the CCD camera to the power absorbed by the scintillator and the length of the exposure through the responsivity of the system. R SYS P absorbed t INT = int[ ]

CCD Noise

Design Light Tight Box CCD Camera Lens System Scintillator Inrun / Outrun Windows

CCD Camera  Starlight Express MX-5  Sony ICX055BL CCD Chip  Single Stage Thermoelectric Cooler (Room Temp – 30 o C)  External USB Controller  Capable of ‘binning’  Linux Based Data Acquisition  3 rd Party USB drivers  Custom camera control software

Optics -Had to balance… - Overall length - Number of lenses - Aperture - Magnification

Source Testing - Used 23 mCi 137 Cs source to test system response - Testing resulted in a series of improvements to apparatus

137 Cs Emission Spectrum

Data Analysis/Processing Original Image of 137 Cs Source Radiation Background Subtracted Image Image processed to remove bad pixels

Calibration -Performed to find the system responsivity, R SYS -Combines… - Source profile measurement data - Source flux measurement data - Geant simulation results -Provides a link between the image intensity and the gamma-ray flux Source Flux Measurement Geant Simulation Source Profile Data

-Determined by the number of counts in a particular region of the image, divided by the amount of energy deposited in the corresponding region on the scintillator R SYS = N C / (P absorbed t INT ) = 126 Counts per GeV Source Flux Measurement with NaI Detector and Geant Simulation Results

Predicted Exposure Times -Dictated by the signal to noise ratio -Calculated by examining an individual camera “bin” Portion of the signal generated by something other than the incident illumination Portion of the output signal generated due to exposure to illumination n full r sys P absorbed t INT n T = + i dark t INT + n floor

Predicted Exposure Times n T = r sys P absorbed t INT + i dark t INT + n floor n B = i dark t INT + n floor n S = n T – n D = r sys P absorbed t INT δn S 2 = δn T 2 + δn B 2 Background Subtraction is performed to find signal

Predicted Exposure Times -Select a fraction of error, ε, that gives εn S (t INT ) = δn S (t INT ) -Find a solution for t INT that satisfies this relationship

A Plot of the Time Required to Obtain a Fraction of Error, ε, for P absorbed Values of 20, 60 and 100 GeV/s ε

The Time Required to Achieve 5% Error Per Pixel Versus Beam Energy For Various Scintillator-Converter Configurations

Conclusions - The combination of a scintillator, lens system, and CCD camera can be used to measure the profile of a gamma- ray source - Submillimeter resolutions are achievable - The method is non-destructive - Predicted exposure times for a nominal beam flux are less than a minute

In-Beam Testing