INGRESS PROTECTION.

Slides:



Advertisements
Similar presentations
Amphenol Outdoor Connectors
Advertisements

New UL Cable ties for electrical installations
Bronzelite Ingrade Luminaires
1 WUE-567 Industrial 5-port 10/100 TX IP-67 unmanaged switch.
Alien Technology Portal Solution – ALX-9000 Series
Copyright by Silca S.p.A Duo Plus Your first Silca Machine! Enter the world of high quality Locksmithing.
1 CNS/GSS/2008/M6 1 Module 6 Degree of Protection.
NEW “LIGHT WEIGHT” PORTABLE PRINTERS. STAR MICRONICS NEW “LIGHT WEIGHT” PORTABLE PRINTERS SM-S200 SM-T300 Compact- Pocket Size Rugged & Durable – Wearable.
April 7th 2011 Hadco Landscape New Product. Confidential April 7th 2011 Confidential April 7th Agenda 1.Simply Enhancing Life with Light – at Home.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
Photoelectric Beam Detector NRTS Series. 2 1. Outline Dual beam detector NRTS series is a part of Red Barrier series. * 30m 60m 90m (Outdoor) range *6.
Photoelectric Beam Detector NRTM Series. 2 1. Outline Dual beam detector NRTM series is a part of Red Barrier series. * 30m 60m 90m (Outdoor) range *Selectable.
NSF International Webinar Ballast Water Management System (BWMS) Evaluation for U.S. Coast Guard Certification.
Internal use only Hanover Story, March 1,
The Association of Electrical Equipment and Medical Imaging Manufacturers ENCLOSURE TYPES Environmental Conditions : and the Appropriate:
Advanced course of Electrical Drives – Course Project Lesson 1. About the Project My guide and your feedbacks:
1 Week 11 SYSTEM SAFETY Matakuliah: Mechatronics 2 Tahun: 2005 Versi: 1.0/0.
Powered Air-Purifying Respirator
290A Outdoor Housing. Main messaging Camera protection you can rely on, come rain, shine or grime! Take your surveillance outdoors with tailor-made outdoor.
 Salient characteristics / Approvals  Cast Aluminum Enclosures  Plastic Enclosures  Cast Aluminum Control Station as per customer requirement Control.
Research Affecting the Design and Use of Water-Based Fire Suppression Systems Russell P. Fleming, P.E. IFSA Technical Director.
Page 1 February US-Project: Module Portfolio GP DrivesNadja Reiner, SE&A Inc. - Confidential - s Basic understanding of ratings General information.
Kyland-USA / DYMEC INGRESS PROTECTION RATINGS EXPLAINED. Copyright © KUSA, LLC. All rights reserved.
Rocker Switches  Available in illuminated, Non-illuminated and Central illuminated version  Suitable for switching resistive and inductive load  Wide.
Lecture 8: Standards Adapted from a presentation by Dr. Thomas Jerse in Spring 2003 ELEC Summer 2004.
Copyright © 2011 Underwriters Laboratories Inc. ® All rights reserved HAZARD ANALYSIS: Hazard Based Safety Engineering & Fault Tree Analysis Tom Lanzisero,
Chapter One Electrical System Components 1. Electrical Components Electrical components can be divided into 7 categories based on function. 1Source 2Transmission.
LEAR Terminals & Connectors
Combined escape route and emergency fire luminaire Titania BEGHELLI - ELPLAST,a.s Beghelli-Elplast has developed new luminaire Titania, which.
Outdoor Installation 1: Physical Installation & Power over Ethernet (POE) Training materials for wireless trainers.
Environmental Monitoring for Hydro-Power Generating Group Name: WG#1 Source: Kerry-Lynn Gauci, Inmarsat, Meeting Date:
IEEE Standards Coordinating Committee on National Fire Protection Association Standards 2008 National Electrical Code CMP#14 SCC 18 Report on Comments.
Areas of Focus within The Weather and Climate Unit: What is weather?, Climate, Importance of the.
Monitor 52LH2WP SANYO Sales & Marketing Europe GmbH.
Výukový program: Mechanik - elektrotechnik Název programu: Základy elektrotechniky II.ročník, základní charakteristiky elektrických zařízení Vypracoval.
Foss Environments Module. Environmental Factors A relationship exists between a number of environmental factors and how well organisms grow. Environments.
Session 11 Grid Tied PV Systems – Part 1 Standards and Codes October 01, 2015.
Monitor CE52SR3 SANYO Sales & Marketing Europe GmbH.
LOCKSMITHASIA KEY CARD LOCKS CATALOGUE 143 /45-46 Moo.12 Thepprasit Rd, Soi.10 Nongprue, Banglamung Chonburi Tel: , Fax:
Kevin Gudmundsson Legal Metrology Advisor Trading Standards MBIE New Zealand Ben Aitken Trading Standards Officer Trading Standards MBIE New Zealand Test.
EC4019 PA Intrusion & Access Control Technology (IACT) Chapter 6- Environmental Protection Chapter 6- Environmental Protection 1/18/ Prepared by.
BENEFITS OF NANO TECH REFLECTOR  Use of NANO TECH Reflector could reduce the emission of CO  through a delamping programme.  Pay back period of about.
Temperature. Temperature is measured using a thermometer. In the United States, we measure temperature in degrees Fahrenheit.
International Protection Rating for any electrical or electronic device aka: the Ingress Protection Rating or the “IP Code” © D. J. McMahon 2014 rev
Fire Detector Placement
CONCEPT™ TYPE 4X STAINLESS STEEL SLOPED-TOP ENCLOSURE NOVEMBER 2012 EQUIPMENT PROTECTION SOLUTIONS.
Workshop on Safety Tests for Electrical Products Cairo, Egypt 3 – 4 December 2014 Performance tests for electrical lamps, LED lamps and electrical lanterns.
Why Proximity Sensors? A Proximity sensor (also called "Proximity switch" or simply "PROX") responds to the presence of an object close to the sensor.
Our panelists Speakers: Moderator:
Technical Specification
Our panelists Speakers: Moderator:
Our panelists Speakers: Moderator:
IEC Smart Cities SEG Investigating the value of setting up a Systems Committee to manage standards for Smart Cities Michael Mulquin.
Automated Retractable Roof Systems
Photovoltaic Systems Engineering Session 19
TEMPERATURE.
U.S. participation in IECEx Scheme
Key Features of S179 fusion splicer
Capabilities Presented by: (Sales Rep)
Mechanical Dimensions
Product information Levant / Homeglide Outdoor Nov. 2011
Photovoltaic Systems Engineering Session 12
February 2019.
New UL Cable ties for electrical installations
Broadband Global Area Network
Mechanical Dimensions
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

INGRESS PROTECTION

What is Ingress Protection? The International Electrotechnical Commission or IEC provides Ingress Protection (IP) ratings that are used to determine the degree of protection provided by an electrical enclosure. IP ratings define protection differently than an Underwriters Laboratories (UL) or Canadian UL (cUL) Wet Location Listing. © copyright 2006 Bronzelite Rev. 1

Why Ingress Protection? Since the IEC is an international standards organization, IP ratings have global application for lighting luminaire enclosures. Global acceptance of IP rated luminaires ensures straightforward communication of enclosure ratings, facilitating specification on a worldwide scale. © copyright 2006 Bronzelite Rev. 1

What are IP ratings? INGRESS PROTECTION IP ratings designate the degree of protection an enclosure provides against the ingress or intrusion of foreign objects. IP ratings consist of the letters “IP” followed by two numbers. © copyright 2006 Bronzelite Rev. 1

What do the numbers represent? INGRESS PROTECTION What do the numbers represent? IP6X The first number designates protection against solid objects. IPX8 The second number designates protection against water. © copyright 2006 Bronzelite Rev. 1

Professional testing INGRESS PROTECTION Bronzelite tests per the IEC standard, ensuring reliable and quantifiable IP ratings. For optimum results, we perform solid and water intrusion tests on our luminaires. © copyright 2006 Bronzelite Rev. 1

Solid intrusion ratings INGRESS PROTECTION Solid intrusion ratings IP Rating Solid Object Size IP1X > 50mm (1.97”) diameter IP2X > 12.5mm (0.49”) diameter IP3X > 2.5mm (0.098”) diameter IP4X > 1.0mm (0.039”) diameter IP5X dust-protected IP6X dust-tight © copyright 2006 Bronzelite Rev. 1

Solid intrusion testing INGRESS PROTECTION Solid intrusion testing Solid intrusion testing is performed first. The luminaires are energized using the hottest wattage configuration and are operated to steady-state under normal operating temperatures. They are de-energized and put in the dust chamber. After the prescribed time, they are inspected for dust intrusion. The dust-tight IP6X rating means no dust has penetrated into the luminaires. © copyright 2006 Bronzelite Rev. 1

Water intrusion ratings INGRESS PROTECTION Water intrusion ratings IP Rating Type of Water IPX1 vertical dripping IPX2 dripping (up to 15o tilt) IPX3 spraying (up to 60o angle) IPX4 splashing from any direction IPX5 jets from any direction IPX6 powerful jets from any direction IPX7 temporary immersion IPX8 continuous immersion © copyright 2006 Bronzelite Rev. 1

Water intrusion dual IP ratings INGRESS PROTECTION Water intrusion dual IP ratings Per the IEC standard, enclosures only rated IPX7 or IPX8 are restricted use and are unsuitable for exposure to jets of water. Dual ratings are more versatile. For example, IPX6/IPX8 designates an enclosure that protects against both powerful jets (such as from power washers or driving rain) AND against continuous immersion (such as when installations in low lying areas results in pooling of water on top of the luminare or submerged in fountain installations). © copyright 2006 Bronzelite Rev. 1

Water intrusion testing INGRESS PROTECTION Water intrusion testing Water intrusion testing is performed after solid intrusion testing. First, the luminaires are sprayed from all directions with a powerful water jet. © copyright 2006 Bronzelite Rev. 1

Water intrusion testing INGRESS PROTECTION Water intrusion testing Then they are immersed with 1m (3.28ft) of headwater over top of them. After the prescribed time, the luminaire is inspected for water intrusion. The dual IPX6/X8 rating means no water has penetrated into the luminaire. © copyright 2006 Bronzelite Rev. 1