Gas Systems for Particle Detectors R.Guida on behalf of the PH-DT-DI/Gas Service Team PH-DT Seminar CERN September 4 th, 2014.

Slides:



Advertisements
Similar presentations
André Augustinus 15 March 2003 DCS Workshop Safety Interlocks.
Advertisements

Inert Gas Purification Systems Why do we need them??? Many of the materials used in research and development today are extremely air sensitive, and can.
André Augustinus 16 June 2003 DCS Workshop Safety.
RPC Purifiers’ studies /status/ IR, RG
© Copyright 2002 ABB. All rights reserved. - Microelectromechanical Systems for Process Analytics IFPAC 2003 Dr. Berthold Andres ABB Automation Products.
The RPC Closed loop Gas System. Schedule for completion - update Status Supplier: ok Mixer: ok Humidifier: ok Purifiers: installed, but not completely.
Xe leak status C. Garabatos. Leak story The maximum allowable leak rate corresponds to a loss of 10% of the total volume in one year – 0.3 l/h for the.
Hydraulics.
Plans for the Muon Gas and Cooling Systems LHCb infrastructure workshop February Burkhard Schmidt, with important input from Roberto Guida and Beatrice.
Daya Bay Muon Subsystem Review, 7/28-29/2007, IHEP, Beijing Daya Bay RPC Gas System: Design Report & Budget Estimate Changguo Lu, Kirk McDonald Princeton.
02/07/2014R. Guida CERN/PH-DT-DI1 RPC R&D Collaboration PH-DT Topics of Interest Studies of gas systems performance and development of dedicated gas modules.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
Thomas Jefferson National Accelerator Facility Page 1 Hall B Drift Chambers Review, March 2007 George Jacobs Jefferson Lab Hall B 12 GeV Upgrade Drift.
The cryogenic systems of the ATLAS and CMS detectors Johan Bremer on behalf of TE/CRG 06/06/2013AFF.
GIF++ gas systems 21/01/2014Ernesto, Roberto PH-DT-DI gas service1.
Summer Updates- Summer Student Report Emine Altuntas Stephen Fee Supervisors: Mar Capeans, Ivan Glushkov, Roberto Guida Gamma Irradiation Facility.
Optimization of the operation of Muon systems at LHC: a closed- loop gas system for RPCs and a CF 4 -recuperation unit for the CSC of CMS Conseil Européen.
04/02/ FH Plans for 2005 PH-DT1-GS. 04/02/ FH Physicists: Stefan Haider, Serguei Morozov (PJAS), Ferdi Hahn, Mar Capeans Technicians: Andrea.
Thomas Jefferson National Accelerator Facility Page 1 Hall B Drift Chambers Review, March 2007 George Jacobs Jefferson Lab Hall B 12 GeV Upgrade Drift.
Optimization of the Resistive Plate Chamber operation with a closed loop gas system at the Large Hadron Collider experiments M. Capeans, I. Glushkov, R.
Active gas system status. S.Konovalov, K.Zhukov. Active gas system operation. S.Konovalov "Active gas system..."TRT Overview  Good design.
TOF Gas System Project Overview. Content Prototype for Aging tests done for RPC’s TOF Gas System: parameters and module layouts. Special Technology: channel.
19/02/2014A. D'Auria CERN/PH-DT-DI Maintenance ID flushing system:  Maintenance 2 dryers  Installation 2 flow meters  Maintenance of several hygrometers.
The RPC Closed loop Gas System Slides from Bianco and Guida.
26 May 2010Hans Postema - CERN Status and plan for the development and construction of CO2 Cooling System for Pixel Upgrade 1.
Overview of DAQ at CERN experiments E.Radicioni, INFN MICE Daq and Controls Workshop.
ALICE-TRD gas system 1/4/2015R. Guida PH-DT-DI1. TRD gas system Few numbers:  Total number of modules/racks: 20 (max leak rate certified at construction.
Associated detection/extinction systems D. Swoboda.
Andrea Di Simone Andrea Di Simone – INFN Roma2 Andrea Di Simone CERN PH/ATC and INFN-CNAF On behalf of ATLAS RPC groups: Lecce, Napoli, Protvino, Roma2.
ALICE Pixel Operational Experience R. Santoro On behalf of the ITS collaboration in the ALICE experiment at LHC.
TK Dry Gas System Operation  System overview  Dry Gas Consumption  Interlocks and thresholds  Documentation  Operational model  Final comments.
Paolo Guglielmini - TS / CV LHCb Install Meeting - 20/04/2005 LHCb Install Meeting 20/04/05 TS / CV / Detector Cooling Installations.
GIF++ gas systems 11/07/2014Ernesto, Roberto PH-DT-DI gas service1.
ALICE TPC Gas Control System (toward the first fully implemented LHC gas system) S. Haider EP-TA1-GS.
Results from the CMS-RPC tests at CERN Gamma Irradiation Facility Roberto Guida CMS-RPC (Bari, Beijing, Napoli, Pavia, Sofia) Seoul, October 2005.
R. Boyd 1 February  Dr. M. Saleem  D. Jana  M. R. Meera Labbai  R. Boyd.
Johan Bremer, 22th-26th September 2008 Cryogenics Operations 2008, CERN, Geneva, Switzerland 1 CRYOGENICS OPERATIONS 2008 Organized by CERN Safety aspects.
CO2 cooling in CMS General overview 30 July 20101Hans Postema - CERN.
Detector Gas Systems Status Update Ferdi Hahn PH-TA1-GS Detector Steering Meeting November 2004.
CMS consolidation activities of detector cooling system Detector cooling project P. Tropea.
Atlas Gas Systems - CPC6 Upgrade and Re-Commissioning Infrastructure Meeting – 8th January 2014 Steve Pavis PH-DT-DI/Gas.
26/03/2014L-Ph. DE MENEZES & F. MERLET CERN/PH-DT-DI New recuperation system for n-Pentane:  Installation of the module in parallel of the first.
European Organization for Nuclear Research LHC Gas Control System Applications Generation to Deployment phases Strategy/Principles.
25/04/2014R. Guida, A. Wasem PH-DT-DI Gas1 Outline ALICE gas systems meeting Outline Introduction Review usage of ALICE gas M&O 2013 Review achievements.
25/03/2014P. Carrie, R. Guida, S. Pavis PH-DT-DI Gas1 Outline LHCb gas systems meeting Outline Introduction Review usage of LHCb gas M&O 2013 Review achievements.
HMPID maintenance activities during LS1 during LS1 Cosimo Pastore HMPID PLENARY MEETING March 22th, 2013.
Active gas system status & plans. S.Konovalov, K.Zhukov, K.Vorobev.
CMS-GEM gas system GEMs for CMS High Eta Muons - Workshop III, CERN April R.Guida PH-DT-DI.
David Mcfarlane1 CMS Gas Systems (Nitrogen, Argon & CO2)
Totem Gas Systems ( T1, T2 ) F. Hahn and S. Haider PH / DT1.
First discussion on MSS for Katrin March 26, 2013 M.Capeans CERN PH-DT.
GIF++ gas system Outline:  Beam and cosmic trigger  Gas distribution panels  Gas detection (present and final layout)  Conclusions 14/1/2015R. Guida,
S.Colafranceschi 20 June Stefano Colafranceschi LNF Frascati CERN Universita’ di Roma – La sapienza An overview on gas studies, purifier materials.
RPCs with Ar-CO2 mix G. Aielli; R.Cardarelli; A. Zerbini For the ATLAS ROMA2 group.
TRD Gas System Layouts Production Readiness Review 03 – Nov F. Hahn.
AT-ECR/C.FabreMay 31, 2007 Cryogenics for Liquid Argon Calorimeters Caroline Fabre on behalf of the ATLAS Liquid Argon Cryogenics Collaboration.
CV works in the non- LHC accelerator complex during 2008 and plans for 2009 ATOP days 2009.
Monitoring the Concentration of Fluoride and Other Impurities Across a Purification System Naomi Mburu University of Maryland, Baltimore County Supervisors:
Neutrino Platform Proximity Cryogenics 68th EHN1 Cryogenics Integration TE-CRG
Ed Connor, GC Product Specialist
protoDUNE – single-phase Instrumentation - Gas Analyzers
Totem Gas Systems ( T1 , T2 ) S. Haider PH / DT1.
Gas System Commissioning
CMS gas systems meeting
PORTABLE HIGH-SPEED GAS CHROMATOGRAPH
R. Guida PH-DT-DI Boston Students Program CERN, 16/1/2013
CRYOGENICS OPERATIONS 2008 Organized by CERN
Mathew C. Wright January 26, 2009
C.Octavio Domínguez, Humberto Maury Cuna
Presentation transcript:

Gas Systems for Particle Detectors R.Guida on behalf of the PH-DT-DI/Gas Service Team PH-DT Seminar CERN September 4 th, 2014

04/09/2014R. Guida CERN/PH-DT-DI2 Outlook  Introduction  Gases for particle detectors: working principle ▫Working principle ▫Gas mixtures  Gas systems: ▫Construction ▫Building blocks. Examples: mixer, purifiers, analysis, recuperation, …  Gas systems performances: ▫Reliability  Long Shutdown 1: ▫Maintenance, consolidation and upgrades  Gas emissions from particle detectors  Small systems for lab applications  Conclusions Outlook

04/09/2014R. Guida CERN/PH-DT-DI3 Ionizing particles are producing primary ionization (free electrons and ions) Few primary electrons can gain enough energy to produce further ionization n total : total number e - /Ion  E: total energy loss W i : /(total number e - /Ion) Ionization chambers Gases for particle detectors Primary ionization Total ionization Ionizing particle

04/09/2014R. Guida CERN/PH-DT-DI4 Ionization chambers Primary ions/electrons start drifting under the effect of the applied electric field Electrons can gain enough energy to produce secondary ionization and finally electron avalanche Primary electrons Primary ions Primary electron Secondary electron Gases for particle detectors

04/09/2014R. Guida CERN/PH-DT-DI5 The ionization process depends strongly on the gas type ▫Air is not a good medium  ▫Right mixture can be quite complex and difficult to find Typical gas mixture components:  Bulk gas: Argon – common, not toxic, …  quenching gas added for stability (photons absorption): CO 2, CH 4, iC 4 H 10, …  Others: CF 4, SF 6, … Process is affected even by presence of very low concentration of impurities Ionization chambers Gases for particle detectors

04/09/2014R. Guida CERN/PH-DT-DI6 Ionization chambers Gases for particle detectors  Several applications  Different geometries, gas mixtures, combination of effects, …

04/09/2014R. Guida CERN/PH-DT-DI7 Not only gas for ionization chambers  also gas as radiator RICH detector Cherenkov radiation Gases for particle detectors Example: LHCb experiment: LHCb: RICH2

04/09/2014R. Guida CERN/PH-DT-DI8 Cherenkov radiation Gases for particle detectors Particle identification Cherenkov rings Charged particle θCθC Radiator volume

04/09/2014R. Guida CERN/PH-DT-DI9 Right environmental conditioning: Inert gas flushing system ensuring dry environment allowing operation of pixel detector at temperature as low as -40 °C Inner detectors flushing Gases for particle detectors

04/09/2014R. Guida CERN/PH-DT-DI10 Beyond particle detection… Gases for particle detectors CLOUD experiment: tackling most challenging problems in atmospheric science

04/09/2014R. Guida CERN/PH-DT-DI11 LINAC4: The new linear accelerator will be the first stage of LHC injector complex. Beyond particle detection… Gases for particle detectors Pandora's box: the good side

04/09/2014R. Guida CERN/PH-DT-DI12 Gas systems for the LHC experiments  The basic function of the gas system is to mix the different gas components in the appropriate proportion and to distribute the mixture to the individual chambers.  30 gas systems (about 300 racks) delivering the required mixture to the particle detectors of all LHC experiments.  Gas mixture is the sensitive medium where the charge multiplication is producing the signal.  Correct and stable mixture composition are basic requirements for good and stable long term operation of all detectors. Gas Systems

04/09/2014R. Guida CERN/PH-DT-DI13 Gas systems for the LHC experiments Gas systems extend from the surface building to the service balcony on the experiment following a route few hundred meters long.  Primary gas supply point is located in surface building  Gas system distributed in three levels: ▫Surface (SG) ▫Gas Service room (USC) ▫experimental cavern (UXC) Gas systems Large detector volume (from m 3 to several 100 m 3 ) and use of expensive gas components:  The majority is operated in closed loop gas circulation with a recirculation fraction higher than %.

04/09/2014R. Guida CERN/PH-DT-DI14 The “CERN Gas Service Team”  The gas systems were built according to a common standard allowing minimization of manpower and costs for maintenance and operation. ▫Construction started early 2000 ▫Operational since  The CERN gas service team (PH-DT-DI, EN-ICE, EN-MEF) Patrick Carrie Mar Capeans Andrea D‘Auria Louis-Philippe De Menezes Roberto Guida Ferdinand Hahn Stefan Haider Beatrice Mandelli Frederic Merlet Steven Pavis Ernesto Regano Albin Wasem Several trainee, students Software controls developed in collaboration with EN-ICE Gas supply ensured by EN-MEF Jonathan Dumollard Abdelmajid Laassiri Benjamin Philippe Marichy Herve Martinati + support from CERN users Andrei Kiver Ace Ordanov Gas systems construction

04/09/2014R. Guida CERN/PH-DT-DI15 Gas system: design Gas systems (as detectors) are subject to severe requirements on material & gas for safe detector operation:  Mainly (if needed only) stainless steel pipe and components  Need to validate most of the gas system components  Documentation for QA and easy operation/maintenance follow up  Monitoring of gas system operation  Monitor of supply gases and mixture composition  Evaluation of operational cost  Flexible design to accommodate detector requirements/upgrades  Careful evaluation of ▫resources for operation ▫resources for maintenance activity ▫Stability required ▫Balance requirements vs safety (as much as possible) Gas systems construction

04/09/2014R. Guida CERN/PH-DT-DI16 Gas system construction  Gas systems are made of several modules (building blocks): mixer, pre-distribution, distribution, circulation pump, purifier, humidifier, membrane, liquefier, gas analysis, etc.  Functional modules are equal between different gas systems, but they can be configured to satisfy the specific needs of all particle detector. ▫Implementation: control rack and crates (flexible during installation phase and max modularity for large systems) Gas systems construction Control rack Control crate (PLC) Modules crates Profibus connection to control crate

04/09/2014R. Guida CERN/PH-DT-DI17 Example: Gas supply monitoring system Gas systems building blocks Where is it?

04/09/2014R. Guida CERN/PH-DT-DI18 Gas supply monitoring system  Monitoring for : ▫Gas quality (via analysis devices) before in service operation ▫Replaced battery availability ▫Gas flow for each gas supply  Operational Warnings and Alarms: ▫Battery failed to change over ▫Low pressure/weight in active supply ▫High flow demand ▫Flammable gas interlock active ▫I/O faults ▫H 2 O levels in analysed gas too high ▫O 2 levels in analysed gas too high ▫Backup gas supply not enabled ▫Dewar full but not in service  Implemented in collaboration with EN-MEF Gas systems building blocks

04/09/2014R. Guida CERN/PH-DT-DI19 Example: Mixer module Gas systems building blocks Where is it?

04/09/2014R. Guida CERN/PH-DT-DI20 Mixer module  Standard Mixer module can have up to 4 input lines (gas and liquid).  Primary task: provide the sub-detector with a suitable gas mixture during run.  Different needs for filling or purging (i.e. high flow or different mixture)  Mixture injection regulated according to detector need: ▫Correction for atmospheric pressure change (majority of detector are operated at constant relative pressure, i.e. the quantity of gas in the detector follow the atmospheric pressure changes  mixture need to be stored) ▫Mixture replacement in the detector ▫Recuperation efficiency or leak rate  Warning/Alarms available: ▫Gas supply pressures ▫Flow not stable/reliable ▫Flow regulation (Mixing ratio) Gas systems building blocks

04/09/2014R. Guida CERN/PH-DT-DI21 Example: Gas analysis module Gas systems building blocks Where is it? Many connections in SGX, but also in US or UX… basically everywhere

04/09/2014R. Guida CERN/PH-DT-DI22 Gas analysis module  Used to analyze the gas mixture  Two types: gas source selected by means of standard valves or special n-way valves. ▫Several sample chains may be organized in several physical location. ▫Each sample chain completely independent  The module operated in automatic mode: ▫sample the gas streams or the reference gases selected by experts. ▫experts are able to trigger sampling of selected sources. ▫length of the sampling lines taken in considerations to define flushing delays.  Alarm and data exchange with detector DCS  Used for safety (flammability level)  Gas chromatographs connected for more specific analysis Gas systems building blocks

04/09/2014R. Guida CERN/PH-DT-DI23 Gas analysis module  Fully automated O2 + H2O analysis module Gas systems building blocks O 2 in C 2 H 2 F 4 supply: usually below 50 ppm Sometime contamination up to thousand ppm.

04/09/2014R. Guida CERN/PH-DT-DI24 Gas analysis module  Gas chromatographs are used to monitor: ▫Stability of mixture composition ▫Presence of more complex impurities  CMS and LHCb equipped with GC connected to the selection manifold of the standard analysis rack.  Others GC are directly operated by users Gas systems building blocks SF6 in RPC system CO2 in DT system  Other monitoring system based on detector are under development

04/09/2014R. Guida CERN/PH-DT-DI25 Example: Purifier module Gas systems building blocks Where is it?

04/09/2014R. Guida CERN/PH-DT-DI26 Purifier module  One of the most complex modules  Used to remove O 2, H 2 O and more from mixture  Fully automated cycle  2 x 24 l columns filled with suited absorber: ▫Molecular sieves ▫Metallic catalysts ▫others Gas systems building blocks

04/09/2014R. Guida CERN/PH-DT-DI27 Purifier module  Many modules operational with many different gas mixtures and cleaning agents Gas systems building blocks

04/09/2014R. Guida CERN/PH-DT-DI28 Purifier module  Many development tricks: ▫Cleaning agents absorb not only impurities  mixture was destabilized at the beginning of each cycle ▫Gas used during regeneration remains trapped in the cleaning agents ▫Too much gas was absorbed right at the beginning of the cycle  pressure destabilized CO 2 absorbed at the beginning of the cycle Argon is released by molecular sieves: Gas systems building blocks  Operation sequence was completely reviewed and still under discussion: ▫Preparation for Run phases introduced ▫Optimization of regeneration sequence

04/09/2014R. Guida CERN/PH-DT-DI29 Example: Distribution module Gas systems building blocks Where is it?

04/09/2014R. Guida CERN/PH-DT-DI30 Example: distribution module Gas systems building blocks Mixture distribution modules equipped with: ▫Supply and return flow read-out system developed in the team ▫Flow regulation system At channel/chamber level

04/09/2014R. Guida CERN/PH-DT-DI31 Example: distribution module Gas systems building blocks View of control system for mixture distribution of one gas system Parameters monitored for each unit

04/09/2014R. Guida CERN/PH-DT-DI32 Example: Recuperation plants Gas systems building blocks Where is it? Gas recuperation plant

04/09/2014R. Guida CERN/PH-DT-DI33 Recuperation systems: CF 4  Recuperation systems: needed for empting and regulating impurity levels reducing as much as possible gas consumption  Example:  CMS-CSC CF 4 warm adsorption: ▫built and fully commissioned during ▫fully automated system running on a dedicated PLC. All the parameters can be monitored and controlled through a PVSS remotely accessible software interface. ▫the system consists of 5 physical racks ▫it was built following the standard used for the construction of the gas systems for the LHC experiments. ▫plant is paid back in about two years of operation. ▫operational since June 2011 Gas systems building blocks

04/09/2014R. Guida CERN/PH-DT-DI34 Recuperation systems: CF 4 Gas systems building blocks Input to the plant Phase 1: Bulk CF 4 separation from the mixture  membrane Phase 2: adsorption of remaining CO 2  Molecular Sieve 4Å Phase 3a: CF 4 adsorption  filling Mol. Sieve 13X from -1 to 0 bar Phase 3b: CF 4 recovery  extraction from Mol. Sieve 13X (0  -1 bar) open close CF 4 adsorption and extraction Technical challenge: first plant built for CF 4 warm adsorption It is a completely non-standard system

04/09/2014R. Guida CERN/PH-DT-DI35 Recuperation systems: Xe  Xe cold trapping (ALICE-TRD, ATLAS-TRT) Gas systems building blocks New control rack and interface for automated operation Old distillation column

04/09/2014R. Guida CERN/PH-DT-DI36 Recuperation systems: nC 5 H 12  nC 5 H 12 cold trapping (ATLAS-TGC) Gas systems building blocks Liquefier Storage tank

04/09/2014R. Guida CERN/PH-DT-DI37 Reliability over the past years  Results from analysis of the interventions performed during On average only 1.5 h/year/system of downtime (power-cuts and outside events excluded) Intervention are ▫Equally distributed between experiments ▫Decreasing with time 24/24h on-call service provided Intervention triggered by: Gas systems performances

04/09/2014R. Guida CERN/PH-DT-DI38 Reliability over the past years Sources of down-time, analysis: Issues with gas system modules account only for about 30 h / 150 h Known issues (partially related to detector weaknesses) Gas systems performances

04/09/2014R. Guida CERN/PH-DT-DI39 LS1 maintenance activities  Extensive maintenance program on going during LS1 including: ▫Standard maintenance (yearly maintenance), i.e. circulation pumps, safety valves, power supply, … ▫LS1 extraordinary maintenance, i.e. analysis devices, flow-cells calibration, MFCs calibration, …  Consolidation/upgrade program during LS1: ▫upgrade circulation pump modules (one pump redundancy) ▫Replace H 2 O analysers ▫Complete analysis modules for gas supply monitoring system ▫Modify system from open mode to recirculation Example: ▫About 150 MFCs need to be checked/calibrated ▫Maintenance started ▫Found important discrepancy especially in high flow MFCs (used during detector fill) Gas systems performances

04/09/2014R. Guida CERN/PH-DT-DI40 Gas emissions from particle detectors  Operational costs and Greenhouse Gas (GHG) emission  Total emission:  tCO 2 e  Main contribution C 2 H 2 F 4 (R134a), CF 4, SF 6 Gas emissions from particle detectors ATLAS and CMS RPC systems Upgrade activities Normal operation

04/09/2014R. Guida CERN/PH-DT-DI41 Gas consumption: cost and GHG emission 13 gas systems already equipped with gas recirculation:  nevertheless they represent 85% of total tCO 2 e emission  but emissions already reduced by more than 90%. ▫Remaining 10% due to: ∙Leaks in detector: 74 % (mainly ATLAS and CMS RPC systems) ∙Need of controlling N 2, H 2 O, O 2 levels and purifiers: 11% (mainly CMS-CSC) 12 gas systems without gas recirculation  15% of total tCO 2 e emission  some room for improvement (details in the following) 3 ID flushing systems  negligible contribution (< 1%) Gas emissions from particle detectors Recirculation efficiency tCO 2 e wrt recirculation efficiency

04/09/2014R. Guida CERN/PH-DT-DI42 GHG emission by detector: expectation after LS1 ATLAS ALICE CMSLHCb Very optimistic Very Optimistic (almost achieved) Easily achievable: on-going upgrade CF 4 recuperation Plant operational High [SF 6 ] Short term activity Not clear plan for future Possible overall reduction by 40%... However, strongly dependent on results from leak search campaign on RPC systems Gas consumption: cost and GHG emission Gas emissions from particle detectors

R. Guida CERN/PH-DT-DI43 Small recirculation system for R&D Two small systems developed:  Prototype used at GIF (2003)  New simplified version for lab R&D ( ) Conclusions 04/09/2014

R. Guida CERN/PH-DT-DI44 Conclusions  30 gas systems (about 300 racks) delivering the required mixture to the particle detectors of all LHC experiments.  Designed and built according to functional modules: ▫Simplified maintenance and operation activities for the team ▫Fully automated systems with remote control/monitoring ▫few examples (mixer, purifier, analysis, recuperation, …) were briefly discussed  Gas systems have demonstrated an impressive availability level: ▫On average 1.5 h downtime/year (excluded external causes, i.e. power-cuts, …)  LS1 maintenance and consolidation plan (trying to improve, prepare for new detector requirements, anticipate ageing of components)  Strategy for reducing gas emissions due to particle physics activities at CERN (reduce operational costs and greenhouse gases)  Small prototype systems developed for R&D applications in any lab Thanks for your attention Conclusions 04/09/2014