Integrated sensor handled by robot for dose rate measurement Karim BOUDERGUI, Anne Marie FRELIN, Vladimir KONDRASOVS, Stephane NORMAND CEA, LIST, Sensors.

Slides:



Advertisements
Similar presentations
Wireless battery charging. Why? Patent No Currently lots of electronics devices such as Laptops, mobile phones are a necessity Cables or.
Advertisements

Portable Instruments & Area Monitors
THS3000 Product Introduction Market Dynamics  Customers require more flexible solutions  Many test solutions are driven by both measurement needs.
Training for Radiation Pagers Training for Radiation Pagers Berkeley Nucleonics Corporation 2955 Kerner Blvd. San Rafael, CA
Types of Exposure Devices
ODS3F –Observation and Detection Systems For Forest Fire Monitoring
Detecting and Measuring Ionizing Radiation -2
1 Introduction USG – 573 RMDS - Radioactive Material Detector System.
There are two kinds of radiation monitors used for medical purposes: survey monitors personal monitors.
1978: A potential disaster Uncontrolled re-enter of the nuclear powered satellite Cosmos 954 with 30 kg of 235 U Nuclear fuel scattered on an area of
Nuclear Radiation Basics. Copyright © 2011International Medcom Contents What is Radiation? What is Radiation? Instruments that Measure Nuclear.
Exhaust Emissions Analyzer Introduction In a day when global CO 2 levels are one of the greatest concerns of society, surprisingly few advances have been.
13 Oct 2005 ICALEPCS RAMSES: The LHC RAdiation Monitoring System for the Environment and Safety G. Segura CERN on behalf of the RAMSES team.
Deon Blaauw Modular Robot Design University of Stellenbosch Department of Electric and Electronic Engineering.
Rohrback Cosasco Systems, Inc.
ISolar Portable Folding Solar Kit 45W. Packing Box Size : 40 x 26 x 10 cm (15.8 x 10.2 x 3.9 in) Weight : 3.5 Kg (7.72lb)
Solar Portable Folding Solar Kit 24W. ▼ Home use Application of Solar ▼ Subway ▲ Camping ▲ Emergency and rescue use ▲ Cafe ▼ Recreation Vehicle (RV) ▼
4/2003 Rev 2 II.3.1 – slide 1 of 30 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 1Ionization Chambers.
Management of emergencies in industrial radiography
IN-PIPE ISPECTION ROBOT Students: DEL BUFALO GIOVANNI NOTARO GIANLUCA ROVARDI ALESSANDRO Professor: VIKRAM KAPILA Mechatronics Final Project Design.
Smart Materials in System Sensing and Control Dr. M. Sunar Mechanical Engineering Department King Fahd University of Petroleum & Minerals.
Fiber-Optic Dosimeter. Orbital Therapy’s HRD-6 High Resolution Fiber Optic Dosimeter is the first in a new class of radiation dosimeters with unprecedented.
MECE 1101 Introduction to Mechanical Engineering
Dosimetry Sanja Dolanski Babić March, Ultrasound interaction with tissue.
REPLUS BATTERY REGEN Technical sales support: electrical products Lode Baert.
20 F POWER MEASUREMENT FOR GENERATION IV SODIUM FAST REACTORS R. Coulon, S. Normand, M. Michel, L. Barbot, T. Domenech, K. Boudergui, J-M Bourbotte, V.
RADIATION DOSIMETER MKS-01СА1М Technical proposal.
Detailed Design Review P UAV Telemetry Chris BarrettProject Manager Gregg GolembeskiInterface Manager Alvaro PrietoRadio Concepts Cameron BosnicSoftware.
New CZT Handled spectrometer Karim BOUDERGUI, Vladimir KONDRASOVS CEA, LIST, Sensors & Electronic Architectures Laboratory, Gif-sur-Yvette CEDEX,
Use it, Interconnect it, AutoMate IT™ ( Based on the FlexiMax 9000 Technology)
TEAM INITECH DARPA Grand Challenge. TEAM INITECH Context Currently an OSU team is involved in creating an autonomous off road vehicle to be used in the.
Problem Statement Automotive and heavy equipment applications use sensors on machines to report temperatures, pressures, speeds, etc. to a central embedded.
Team Ocho Cinco Raymond Chen Zhuo Jing Brian Pentz Kjell Peterson Steven Pham.
MWPC sandwich panels C.Forti INFN-LNF / LHCb-MUON EDR CERN 16 th April sandwich panels typologies of cathodes the mould the production procedure.
GAS CAMERA Mobile imaging system to detect methane plumes from distances between 0 m and at least 100 m Dr. Arnd Schmücker, Peter Schwengler TGLS, Pipelines.
The Sentry Personal Alarming Dosimeter and Rate Meter.
MX-10: Pixel Particle Detector V.Viswanathan, S.Martinek, M.Honig, P.Hubner Dr.Vijayaragavan VISWANATHAN 27/10/2013 IEEE-NSS: New Detector.
A.L.F. Enterprise n Electrical Parameters Measurement Component (EPMC) n Boris Fradkin ©A.L.F.Enterprise Boris Fradkin.
1 Miniradmeter: a miniature detector for gamma rays (and neutrons?) G.Alimonti, P.Finocchiaro A miniature detector for gamma rays (and neutrons?) G.Alimonti,
: TiM551 – Ranging Laser Scanner Incredibly good at detection - absolutely accurate at measuring Aaron Rothmeyer.
Electronic Dosimeter Canberra Mini-Radiac
Compton imaging with the PorGamRays Detector D S Judson Imaging 2010, Stockholm, 8 th -11 th June 2010.
CEA DSM Irfu SIS LDISC 18/04/2012 Paul Lotrus 1 Control Command Overview GBAR Collaboration Meeting Paul Lotrus CEA/DSM/Irfu/SIS.
Contents: 1. Introduction 2. Gyroscope specifications 3. Drift rate compensation 4. Orientation error correction 5. Results 6. Gyroscope and odometers.
T rack W arning S ystems. 300,4M€ 289,1M€ 303,7M€ ACTIA GROUP KEY FIGURES PFT-Ind GB.pptx  Created in 1986  2700 staff over the world  Automotive.
SERIOUS 3D GAME FOR EDUCATION AND TRAINING IN RADIATION PROTECTION Rovinj – 2014 Alain PIN (CEA/INSTN/UECO) – France.
Company Presentation 2016 A short introduction to I&C Services BV.
AGROFARM WEATHER MONITOR USING LabVIEW. INTRODUCTION Innovation in agriculture field Implementing instrumentation tech. in agricultural field The quantity.
Environmental Incidents Management Training Programme AN AWARENESS PRESENTATION BY – DAI BOYLE & KEITH MEREDITH (MID & WEST WALES & SOUTH WALES) ASSISTANT.
1 PASSIVE DOSIMETER BENCHMARKING. 2 CONTEXT French regulations originally required film to be used as a passive dosimeter. The decision dated 23 rd March.
Under The Guidance Of Ms. SWETHA.G.N ( Dept of Mechanical Engg) RAMESH MARATHI 1GV09ME407 BY.
Extra-light gamma-ray imager for safeguards and homeland security
GammaTRACER Key features
Solar gamma-ray and neutron registration capabilities of the GRIS instrument onboard the International Space Station Yu. A. Trofimov, Yu. D. Kotov, V.
An-Najah National University New Campus, Nablus, Palestine
NWU IT-ES/NWU IT-ELD Monitoring systems
Wall-E Prototype I The design project Wall-E Prototype I is an intelligent automated trash collecting robot with obstacle detection capability. The robot.
AUBERT Bernard*, GUILABERT Nadine°, LAMON Annick* and RICARD Marcel*
Copyright SwissFlow B.V.
Gas Detectors for Neutron Dosimetry and Monitoring
Towards a Unified Environmental Monitoring,
Financial support is needed
Unit 3 – Fundamentals of Electronics Examination Specifications
The EDR Gamma Scanner José M. Pérez* , O. Vela, E. de Burgos CIEMAT
Unit 3 – Fundamentals of Electronics Examination Specifications
New concepts and instruments for 14C measurements in i-graphite
Independent solar power PIR motion sensor
Pressure Level Sensor OTT PLS
Multi Stage Engineering
There are two kinds of radiation monitors used for medical purposes: survey monitors personal monitors.
Presentation transcript:

Integrated sensor handled by robot for dose rate measurement Karim BOUDERGUI, Anne Marie FRELIN, Vladimir KONDRASOVS, Stephane NORMAND CEA, LIST, Sensors & Electronic Architectures Laboratory, Gif-sur-Yvette CEDEX, FRANCE INTRODUCTION MEASUREMENTS SRIP ROBOT DESCRIPTION CONCLUSION SPECIFICATIONS This radiometer has shown good results during the different tests: a good linearity (discrepancies below 10 % for dose rate measurements), angular response about 5% and good real-time performances. With its compact and robust metal case it represents a good tool to be embedded inside drones (aerial or terrestrial). This new warning radiometer will soon be marketed by the French company SDS New Nuclear and Radiological threats and growing industrial risks have induced new needs as the use of robotic systems. The SRIP research project (Systèmes Robotisés d’Intervention pour sapeurs Pompiers), in the frame of the French ANR program agency, aims to develop a land robotic system with increased detection capabilities adapted to the needs of rescue teams. This development was run by a consortium of complementary partners: ECA Company for robotic, CEA and INERIS bringing their knowledge in detection technologies and ENSOSP and SDIS 13 providing their intervention and rescue skills. The system includes a modular robot base integrating a large choice of sensors (chemical, radioactive…) and more particularly a new radiometer achieving a highly reliable dose measurement even in drastic environment conditions (vibration for instance), specially designed by CEA to fit at the best requirements for security applications. Technical specifications  Radio or wire control  Motion: 2 tracks + 2 front flippers  Obstacle clearance: up to 30cm  Slope and stairs: up to 45°  Payload capability: up to 20kg  Temperature : -15°C to +55°C  Chemical resistance (acids, bases, ammoniac, chlorine….)  Explosive atmosphere management  Fast robot set-up (<2 min) and easy to use command & control unit Figure 1. Geiger Müller dosimeter developed at the CEA to equip the prototype Figure 6 : Geiger Müller dosimeter developed at the CEA to equip the prototype Nuclear  Display units: µSv/h, µSv or µrem, µrem/h depending on meter connected; H*(10) ambient gamma dose equivalent rate.  Emitter: Gamma.  Detector: Energy Compensated Geiger Mueller.  Sensitivity: 2.4 c/s for μSv/h (137Cs).  Measurement range:0.1 μSv/h to 40 mSv/h (10 μrem/h to 4 rem/h).  Energy range:Gamma 36 keV to 1.5 MeV.  Background:Ambient <0.1 μGy/h (10 μR/h), 0.16 c/s.Ergonomic  Display:Provided by host instrument or PC.  Alarm setpoint:Saved in probe memory. It can be charged with a PC. Electrical  Power:Supplied by PC (USB) or Battery  Battery life:up to 10 hours of battery autonomy Mechanical  Housing :Aluminum.  Dimensions :90 x 32 mm (3.5 in. x 1.26 in.) (L x D).  Weight:88 g (0.19 lb), without cable. Environmental  Temperature:-10 °C to +40 °C (14 to +104 °F).  Cleaning:Housing easy to decontaminate.  Water resistance:Waterproof 1 m deep underwater connected(IP67). Figure 3 : Angular measurement of dosimeter response The angular response is very uniform with a standard deviation of ca. 5 %. Figure 5 : Real time counting rate and filtered dose rate measured with a 60 Co irradiator at 18 μSv/h. Time response radiometer is less than 10s for dose rates below 100 µSv/h and less than 2s for other dose rates Figure 4 : Normalized counting rate with regard to the orientation Figure 2. GAM Portable Gamma-Ray Detector prototype