Results Fig. 4a shows the raw, noise-free, simulation data for a sample with T 1 = 1 s and T 2 = 100 ms. A clear difference is seen between the cases where.

Slides:



Advertisements
Similar presentations
Artificial Intelligence 12. Two Layer ANNs
Advertisements

Pulse Timing parameters & Weighting
Assessment of tumoural ADC’s in rectal Tumours using Burst: New methodological Developments SJ Doran 1, ASK Dzik-Jurasz 2, J Wolber 2, C Domenig 1, MO.
Evaluation of Reconstruction Techniques
Grey Level Enhancement Contrast stretching Linear mapping Non-linear mapping Efficient implementation of mapping algorithms Design of classes to support.
The Impact of Channel Estimation Errors on Space-Time Block Codes Presentation for Virginia Tech Symposium on Wireless Personal Communications M. C. Valenti.
Parameters and Trade-offs
Principles of MRI: Image Formation
« هو اللطیف » By : Atefe Malek. khatabi Spring 90.
More MR Fingerprinting
Using Diffusion Weighted Magnetic Resonance Image (DWMRI) scans, it is possible to calculate an Apparent Diffusion Coefficient (ADC) for a Region of Interest.
Master thesis by H.C Achterberg
Lecture 2: Numerical Differentiation. Derivative as a gradient
Adaptive Rao-Blackwellized Particle Filter and It’s Evaluation for Tracking in Surveillance Xinyu Xu and Baoxin Li, Senior Member, IEEE.
Lecture 8: Fourier Series and Fourier Transform
Basics of Magnetic Resonance Imaging
FMRI: Biological Basis and Experiment Design Lecture 7: Gradients and k-space FFT examples –Sampling and aliasing Gradient Gradient echo K-space
Whiteboardmaths.com © 2007 All rights reserved
Introduction The effect of air-cavities within the human body, for example in the head and neck regions, present possible sources of error when calculating.
Radiofrequency Pulse Shapes and Functions
Principles of MRI Physics and Engineering
PULSE MODULATION.
A new method for diffusion imaging using Burst excitation C. Wheeler-Kingshott 1, D. Thomas 2, M. Lythgoe 2, S. Williams 2 and S. J. Doran 1 1 University.
Physics 114: Lecture 15 Probability Tests & Linear Fitting Dale E. Gary NJIT Physics Department.
Unsupervised learning
Jason P. Stockmann 1 and R. Todd Constable 1,2 Yale University, Department of Biomedical Engineering 1, Department of Diagnostic Radiology 2, New Haven,
Quantitative Phase Amplitude Microscopy of Three Dimensional Objects C.J. Bellair §,+, C.L. Curl #, B.E.Allman*, P.J.Harris #, A. Roberts §, L.M.D.Delbridge.
ISMRM2012 Review Jun 4, 2012 Jason Su. Outline Parametric Mapping – Kumar et al. A Bayesian Algorithm Using Spatial Priors for Multi-Exponential T2 Relaxometry.
DelayRatio: A Gravitational Wave Event Physical Likelihood Estimator Based on Detection Delays and SNR Ratios Amber L. Stuver LIGO Livingston ObservatoryCalifornia.
Wireless Communication Technologies 1 Outline Introduction OFDM Basics Performance sensitivity for imperfect circuit Timing and.
Physics 114: Exam 2 Review Lectures 11-16
In Burst experiments, the read gradient is much larger then the other imaging gradients, hence, only translation along this gradient direction will cause.
Introduction Magnetic resonance (MR) imaging is recognised as offering potential benefits in the delineation of target volumes for radiotherapy (RT). For.
G Practical MRI 1 Gradients.
Fig. 3 shows how a dose distribution that is initially relatively sharp becomes blurred with time, until after 16 hours, virtually no useful information.
A finite element approach for modeling Diffusion equation Subha Srinivasan 10/30/09.
Simple regression model: Y =  1 +  2 X + u 1 We have seen that the regression coefficients b 1 and b 2 are random variables. They provide point estimates.
Burst: Applications in Ultra-Rapid Imaging and Quantitative Diffusion Measurement Simon J Doran Department of Physics, University of Surrey S Dr. S. J.
Peng Lei Beijing University of Aeronautics and Astronautics IGARSS 2011, Vancouver, Canada July 26, 2011 Radar Micro-Doppler Analysis and Rotation Parameter.
Effect of Noise on Angle Modulation
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
Fiber Demixing with the Tensor Distribution Function avoids errors in Fractional Anisotropy maps Liang Zhan 1,Alex D. Leow 2,3, Neda Jahanshad 1, Arthur.
Flow-resolution Enhancement in Electrophoretic NMR Using De-noising and Linear Prediction Flow-resolution Enhancement in Electrophoretic NMR Using De-noising.
Víctor M. Castillo-Vallejo 1,2, Virendra Gupta 1, Julián Félix 2 1 Cinvestav-IPN, Unidad Mérida 2 Instituto de Física, Universidad de Guanajuato 2 Instituto.
Double RF system at IUCF Shaoheng Wang 06/15/04. Contents 1.Introduction of Double RF System 2.Phase modulation  Single cavity case  Double cavity case.
Digital Image Processing Lecture 16: Segmentation: Detection of Discontinuities Prof. Charlene Tsai.
PARALLEL FREQUENCY RADAR VIA COMPRESSIVE SENSING
Intravoxel Incoherent Motion Imaging in Locally Advanced Rectal Tumours Dr S J Doran Department of Physics University of Surrey S 1 Department of Physics,
Conclusions Simulated fMRI phantoms with real motion and realistic susceptibility artifacts have been generated and tested using SPM2. Image distortion.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
Digital Image Processing
S.Frasca on behalf of LSC-Virgo collaboration New York, June 23 rd, 2009.
Measuring Water Diffusion In Biological Systems Using Nuclear Magnetic Resonance Karl Helmer HST 583, 2006
Digital Image Processing Lecture 16: Segmentation: Detection of Discontinuities May 2, 2005 Prof. Charlene Tsai.
Magnetic Resonance Learning Objectives
1Ben ConstanceCTF3 working meeting – 09/01/2012 Known issues Inconsistency between BPMs and BPIs Response of BPIs is non-linear along the pulse Note –
Computer Graphics Lecture 30 Mathematics of Lighting and Shading - IV Taqdees A. Siddiqi
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
بسم الله الرحمن الرحيم Dr. Maged Ali Hegazy Assistant Professor Alazhar University.
Parameters which can be “optimized” Functional Contrast Image signal to noise Hemodynamic Specificity Image quality (warping, dropout) Speed Resolution.
Date of download: 7/5/2016 Copyright © 2016 SPIE. All rights reserved. A graph of the structure factor at volume fractions fv=0.001, 0.2, and 0.5 as a.
Date of download: 7/10/2016 Copyright © 2016 SPIE. All rights reserved. A graphical overview of the proposed compressed gated range sensing (CGRS) architecture.
Physics 114: Lecture 13 Probability Tests & Linear Fitting
FMRI data acquisition.
Radar Micro-Doppler Analysis and Rotation Parameter Estimation for Rigid Targets with Complicated Micro-Motions Peng Lei, Jun Wang, Jinping Sun Beijing.
Where Mt is the magnetization at time = t, the time after the 90o pulse, Mmax is the maximum magnetization at full recovery. At a time = one T1, the signal.
R.A.Melikian,YerPhI, , Zeuthen
Apparent Subdiffusion Inherent to Single Particle Tracking
Geology 491 Spectral Analysis
(4)ELECTRONIC SUPPORT SYSTEM
Presentation transcript:

Results Fig. 4a shows the raw, noise-free, simulation data for a sample with T 1 = 1 s and T 2 = 100 ms. A clear difference is seen between the cases where  = 0.1  (linear approximation) and 22  (max. value allowed in [7] for 9 pulses). All the points are higher, because some of the contributing magnetisation spends time along the longitudinal axis. Fig. 4b, simulated with Gaussian noise of 1% maximum signal, shows how, as  increases, the relative error in T 2 determination goes up dramatically (high values clipped at 50%). Figure 4: (a) Echo amplitudes for the 9-pulse Burst sequence with T 1 = 1 s and T 2 = 100 ms for  = 0.1 s (black crosses) and  = 22  (red asterisks); (b) error in T 2 fit for a range of pulse angles and T 2 values; (c) results for bi-exponential T 2. Figure 4c shows the results of simulating a sample with two T 2 decay components (T 2short = 0.05 s, T 2long = 0.3 s). The short component is well-estimated up to  ~ 10°, but the error increases very rapidly with pulse angle. ab c Feasibility of extracting quantitative measurements of T 2 and diffusion using sequences based on the Burst concept S Simon J Doran Department of Physics, University of Surrey, Guildford, GU2 7XH, UK Introduction Burst [1] was originally suggested as a single-shot, ultra-fast imaging sequence. However, the ability to acquire a large number of echoes after a single excitation period leads to the possibility of obtaining quantitative data, weighted primarily by diffusion and T 2. Figure 1a illustrates the basic concept of the Burst sequence. Hennig [1] hinted that it might be possible to use a variant of the sequence in order to measure diffusion coefficients and this work was taken forward by Doran and Décorps [2] demonstrating that a simultaneous measurement of D and T 2 was possible in a single-shot for bulk samples — see Figure 1b. Figure 1: (a) Pulse sequence diagram for Burst — this represents the basic concept; many variations exist. (b) Results from [2] showing how the Burst echoes decay according to a simple model with T 2 and diffusion and form the basis of a rapid, simultaneous measurement of these two quantities. RF G read DANTE train of N low flip-angle pulses Train of N echoes, read out in reverse order 180° pulse Note the decay of the Burst echoes due to T 2 and diffusion a Theory and computation A Burst excitation pulse train is simply a set of n pulses of flip angle , with periods of constant read-dephasing between them. The many echo pathways lead to echoes with amplitudes that are complicated functions of , T 1, T 2 and D. The effects can be calculated in a number of ways: via numerical simulation of the Bloch equation, via the partition method of Kaiser et al. [4], via Hennig’s phase graph algorithm and consequent transition matrix formalism [1,5], or by using the recently developed methodolgy due to Kiselev [6]. In this work, we chose to use direct simulation of the Bloch equations, which is feasible for a small number of RF pulses. The initial work presented here focuses on the quantitative analysis of T 2, but similar methods should be applicable to combinations of T 2 and D. The spin-echo Burst sequence of Fig. 3, with pulses phase- modulated according to [7] was simulated for hypothetical samples with zero diffusion coefficient and combinations of T 1 and T 2.  was varied between 0  and 30  and a standard T 2 decay model fitted to the data. In a second computational experiment, the sample had a bi-exponential decay.  180   Figure 3: The Burst sequence simulated for this work, presented as an extended phase graph [1,5]. Solid lines represent the dominant echo formation pathways for small pulse angles. References [1]J Hennig and M Hodapp, MAGMA 1, 39–48 (1993) [2]S Doran and M Décorps,, J. Magn. Reson. A, 117 (2), 311–316 (1995) [3]Wheeler-Kingshott et al., Magn. Reson. Med., 44 (5), 737–745 (2000) [4]Kaiser et al., J. Chem. Phys., 60 (8), 2966 –2979 (1974) [5]J Hennig et al., Magn. Reson. Med., 51 (1), 68–80 (2004) [6]V Kiselev, J. Magn. Reson. 164, 205–211 (2003) [7]L Zha and I Lowe, Magn. Reson. Med., 33(3), 377–395 (1995) b Problem with Burst — “scatter” A natural extension of the Burst method to the imaging context has previously been presented [3]. However, if one uses the low excitation flip angle, , as recommended in [2], then images have a very low SNR. One must increase  sig- nificantly to obtain useful images. However, this leads to a non- random scatter in the points on the decay curve. Figure 2a shows results from [3], acquired on a rat brain at 8T, using the combined T 2 and diffusion coefficient pulse sequence. In this case, 25  -pulses gave rise to 25 diffusion- weighted images of the same slice, all with different b-values. The original hope was that it would be possible to perform multi-exponential fitting to the data. The signal decay is obviously not a single exponential function, but multi-exponential analysis gives poor fits because of the data scatter. Figure 2: (a) Rat brain images at 8 T, with 25 different b-values — data from [3]. (b) Signal decay due to diffusion, as a function of echo number. We know that the scatter in the data is due to Spin Physics and not low SNR, because the results obtained from an ROI are no less “noisy” than for a single pixel. a b Note the scatter in the data — this is not a SNR problem, but a genuine physical effect.