CONGRATULATIONS ON YOUR NEW COCHRAN EMC-20H DIVE COMPUTER Cochran Undersea Technology a division of Cochran Consulting, Inc. Copyright All rights reserved, Protected under one or more Patents, Patents Pending, or Trademarks.
PLEASE SELECT THE PRESENTATION YOU WOULD LIKE TO VIEW FROM THE BUTTONS BELOW. AIR ONLY 1-MIX NITROX 2-MIX NITROX EXIT 1-MIX PO2 2-MIX PO2
THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE AIR ONLY COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.
SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1
SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1
SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1
SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1
THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.
UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE SURFACE INTERVAL SCREEN IS VISIBLE WHENEVER THE UNIT IS AWAKE AND ON THE SURFACE.
IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)
AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN THE ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = bars = )
IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT AUTOMATICALLY GOES TO SLEEP TO CONSERVES BATTERY POWER.
LET’S GO DIVING
AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.
IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.
DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.
Water Temperature Maximum Depth (so far this dive) Current Depth Bottom Time (so far this dive) NDC Time Remain (Time you can stay at current depth without Decompression) Ascent Rate (1 bar = fpm) Note NDC Legend DIVE MODE
A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED
SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.
COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE
WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THE DISPLAYED CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE
THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE
IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES & DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend
THE TEMPerature LEGEND AND VALUES ARE REPLACED BY CEILing LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression
IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES. Deco Ceiling NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)
****************************** PLEASE NOTE THAT DEC TIME AND CEIL DEPTH ARE DISPLAYED ONLY WHEN THE DIVER REQUIRES A DECOMPRESSION STOP. IF THE DIVER DOES NOT REQUIRE A DECOMPRESSION STOP, ONLY NDC TIME AND TEMP WILL BE DISPLAYED. IF THE DEC LEGEND AND VALUES ARE REPLACED WITH THE NDC LEGEND AND VALUES, THEN YOU HAVE FULFILLED YOUR DECOMPRESSION OBLIGATIONS. ******************************
THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST DIVE INTERVAL HAS PASSED.
DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)
SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT
THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.
TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.
NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE SIX PROGRAMMING MENUS.
WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS PdP, PREDIVE PREDICTION.
ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.
THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)
THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU. Conservatism set to 15%
THE FIFTH TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU. On Time set to 10 seconds
THE SIXTH TOUCH BRINGS THE LOG, LOGBOOK MENU.
ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.
EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.
NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…
THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET. AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. Predict DepthCalculated PO2 (Based on FO2 of 21%) Predict NDC Time (Time you can Stay at predict Depth Without Decompression)
PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME. PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.
THE INFORMATION SCREEN GIVES DATA REGARDING THE COMPUTER CONFIGURATION AND THE BATTERY VOLTAGE. Mode Blend Indicator (FO = Air only) Battery Voltage (3.0 Volts)
THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.
WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash
THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.
WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE SETTINGS ARE AS INTENDED.
IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..
THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM. Conservatism set to 15%
A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 & 3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.
THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE TACLITE TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.
THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE. On Time set to 10 seconds
THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number
TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001
IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.
OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE
PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A NORMAL DIVE
ALTERNATE LOGBOOK SCREEN FOR A NORMAL DIVE Battery Voltage (2.9 Volts)
PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A DECO DIVE
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) FOR A DECO DIVE
YOU HAVE JUST COMPLETED A PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.
A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT CLICK ON “PRODUCT MANUALS.”
VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR ENRICHED AIR NITROX APPLICATIONS. COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING” YOUR COMPUTER.
HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE! Click on the door to go back to the main selection screen or click on the stop sign to exit.
THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE SINGLE GAS COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.
SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1
SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1
SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1
SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1
THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.
AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = bars = )
UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. MAIN SCREEN ALTERNATE SCREEN
IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)
ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Nitrox O2% (Of Blend #1 Set Point)
IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.
LET’S GO DIVING
AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.
IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.
DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.
Water Temperature Current DepthCurrent PO2 Bottom Time (so far this dive) NDC Time Remain (Time you can stay At current depth without Decompression) Ascent Rate (4 bars = fpm) MAIN SCREEN VISIBLE DURING A DIVE Note NDC Legend
ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE Nitrox O2% (Of Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive)
A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED
SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.
COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE
WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE
THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE
IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend
THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression
Deco Ceiling IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 10 FEET FOR 20 MINUTES. NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)
ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION Nitrox O2% (Of current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive) Water Temperature
THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST-DIVE INTERVAL HAS PASSED.
DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)
SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT
THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.
TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.
NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE SEVEN PROGRAMMING MENUS.
WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.
ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.
THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)
THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU. Conservatism set to 15%
THE FIFTH TOUCH BRINGS UP THE EAn 1 MENU FOR SETTING BLEND#1 O2%. Blend #1 set to 21.0% O2
THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” SETTING MENU. On Time set to 10 seconds
THE SEVENTH TOUCH BRINGS THE LOG, LOGBOOK MENU.
ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.
EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.
NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…
AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. Predict DepthCalculated PO2 (Based on Blend #1 Set Point) Predict NDC Time (Time you can Stay at predict Depth Without Decompression) THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET.
PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF. PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME.
Mode Blend Indicator (F1 = 1 FO2) Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN. THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE.
THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.
WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash
THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.
WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE SETTINGS ARE AS INTENDED.
IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..
Conservatism set to 15% THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.
A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 & 3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, EAn 1 A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE O2% IN BLEND #1.
Blend #1 set to 32.0% FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN BLEND #1 FROM 21.0 TO 50.0%.
THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.
THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.
On Time set to 10 seconds THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.
THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number
TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001
IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.
OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES
PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A NORMAL DIVE
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Nitrox O2% (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE
PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A DECO DIVE
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Nitrox O2% (Blend #1 Set Point) FOR A DECO DIVE
YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.
A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT FIRST CLICK ON “PRODUCT MANUALS.”
COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING” YOUR COMPUTER. VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR MULTIPLE ENRICHED AIR NITROX APPLICATIONS.
HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE! Click on the door to go back to the main selection screen or click on the stop sign to exit.
THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE TWO GAS COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.
SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1
SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1
SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1
SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1
THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.
AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = bars = )
UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE PLACE OF THE UNIT. MAIN SCREEN ALTERNATE SCREEN
IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)
ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Nitrox O2% (Of Blend #1 Set Point)
IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.
LET’S GO DIVING
AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.
IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.
DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.
Water Temperature Current DepthCurrent PO2 Bottom Time (so far this dive) NDC Time Remain (Time you can stay At current depth without Decompression) Ascent Rate (4 bars = fpm) MAIN SCREEN VISIBLE DURING A DIVE Note NDC Legend
ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE Nitrox O2% (Of Current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive)
A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED
SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.
COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE
WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE
THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE
IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend
THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression
IN THIS EXAMPLE, THE DECO STOP IS REQUIRED AT 10 FEET FOR 20 MINUTES. Deco Ceiling NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)
ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION Nitrox O2% (Of current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive) Water Temperature
THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST DIVE INTERVAL HAS PASSED.
DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)
SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT
THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.
TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.
NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE TEN PROGRAMMING MENUS.
WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.
ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.
THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)
Conservatism set to 15% THE NEXT 1&2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.
THE FIFTH TOUCH BRINGS UP THE EAn 1, BLEND#1 O2% MENU. Blend #1 set to 21.0% O2
THE NEXT TOUCH BRINGS UP THE EAn 2, DECO BLEND O2% MENU. Deco Blend set to 21.0% O2
THE SEVENTH TOUCH BRINGS UP THE dEC b, DECO BLEND TIME BENCHMARK MENU. Deco Blend Time Benchmark set to 600 minutes SO WHAT IS A BENCHMARK ?
THE NEXT TOUCH BRINGS UP THE dEC d, DECO BLEND DEPTH BENCHMARK MENU. Deco Blend Depth Benchmark set to 0 feet SO WHAT IS A BENCHMARK ?
THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU. On Time set to 10 seconds
THE TENTH TOUCH BRINGS THE LOG LOGBOOK MENU.
ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.
TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS. EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES.
NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…
Predict Depth Calculated PO2 (Based on Blend #1 Set Point) Predict NDC Time (Time you can stay At predict depth without Decompression) AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET.
PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF. PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME.
THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE. Mode Blend Indicator (F2 = 2 FO2) BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN. Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in %
THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.
WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash
THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.
WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU. WHEN THIS HAPPENS, THE LAST VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS ALWAYS RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE MENUS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE LIMITS ARE AS INTENDED.
IF SO…FOLLOW THE SAME PROCEDURE TO ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..
THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF CONSERVATISM. Conservatism set to 15%
A SIMILAR SEQUENCE OF TOUCHING CONTACTS 1 & 2 WITH A WET FINGER AND 2&3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGIT OF ADDITIONAL CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, EAn 1. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE OXYGEN PERCENTAGE FOR BLEND #1.
Blend #1 set to 32.0% FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO CHANGE THE O2% IN BLEND #1 FROM 21.0 TO 50.0%
THE NEXT 1 & 2 COIN TOUCH WILL END Blend #1 O2% SETTING AND BRING UP THE EAn 2 MENU WHERE YOU SET THE O2% FOR THE DECO BLEND.
SET YOUR DECO BLEND O2 PERCENTAGE ANYWHERE FROM 21.0 TO 99.9% Deco Blend set to 80.0% ANOTHER 1 & 2 COIN TOUCH AND YOU WILL COME TO THE Dec b MENU WHERE YOU SET THE DECO BLEND TIME BENCHMARK.
WITH THE SAME SEQUENCE OF 1 & 2 WET FINGER TOUCHES AND 2 & 3 COIN TOUCHES, YOU SET THE DECO BLEND TIME BENCHMARK FROM 10 TO 999 MINUTES Deco Blend Time Benchmark set to 70 minutes SO WHAT IS A BENCHMARK ?
THE NEXT CONTACT 1 & 2 COIN BRIDGE WILL TAKE YOU TO THE dEC d MENU WHERE YOU WILL BE ABLE TO CHANGE THE DECO BLEND DEPTH BENCHMARK.
FOLLOW THE SAME PROGRAMMING PROCEDURE TO CHANGE THE DECO BLEND DEPTH BENCHMARK FROM 0 TO 99 FEET. Deco Blend Depth Benchmark set to 20 feet SO WHAT IS A BENCHMARK ?
THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.
THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.
On Time set to 10 seconds THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.
THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number
TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001
IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.
OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES
PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A NORMAL DIVE
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Nitrox O2% (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE
PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A DECO DIVE
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Nitrox O2% (Blend #1 Set Point) FOR A DECO DIVE
YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.
A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT FIRST CLICK ON “PRODUCT MANUALS.”
HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE! Click on the door to go back to the main selection screen or click on the stop sign to exit.
WHAT ARE BENCHMARKS? Click here to return to Touch Contact Programming Return BENCHMARKS ARE CONDITIONS THAT MUST BE SATISFIED BEFORE THE GAS SWITCH FROM BLEND #1 TO BLEND #2 WILL OCCUR. THE “Dec b” BENCHMARK IS THE BOTTOM TIME OF THE DIVE AFTER WHICH THE GAS SWITCHING WILL BE ENABLED. ONCE THE PROGRAMMED TIME HAS BEEN SATISFIED, THE GAS SWITCH WILL BE CONTROLLED BY DEPTH THE “Dec d” BENCHMARK IS THE DEPTH OF THE GAS SWITCH. ONCE THE DIVER ASCENDS ABOVE THE PROGRAMMED DEPTH, THE GAS SWITCH FROM BLEND #1 TO BLEND #2 WILL HAPPEN. IF BENCHMARK “Dec b” IS NOT SATISFIED THERE WILL NOT BE A GAS SWITCH.
THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE SINGLE PO2 COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.
SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1
SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1
SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1
SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1
THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.
AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = bars = )
UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. MAIN SCREEN ALTERNATE SCREEN
IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) PO2 in ATA (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE
IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.
LET’S GO DIVING
AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.
IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.
DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.
Water Temperature Current DepthCurrent FO2 Bottom Time (so far this dive) NDC Time Remain (Time you can stay At current depth without Decompression) Ascent Rate (1 bar = fpm) MAIN SCREEN VISIBLE DURING A DIVE Note NDC Legend
ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE PO2 in ATA (Of Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive)
A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED
SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.
COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE
WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE
THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE
IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend
THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression
Deco Ceiling IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES. NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)
ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION PO2 in ATA (Of current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive) Water Temperature
THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST-DIVE INTERVAL HAS PASSED.
DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)
SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT
THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.
TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.
NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE EIGHT PROGRAMMING MENUS.
WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR SELECTING EITHER THE FO2 OR PO2 OPERATING MODE. FO2 SCREEN PO2 SCREEN
THE SECOND MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION. TOUCH OR BRIDGE CONTACTS 1 AND 2 AGAIN WITH A COIN.
ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.
THE FORTH COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)
THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU. Conservatism set to 15%
THE SIXTH TOUCH BRINGS UP THE PO2 1 MENU FOR SETTING BLEND#1 PO2. Blend #1 set to 0.70 ATA
THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” SETTING MENU. On Time set to 10 seconds
THE EIGHTH TOUCH BRINGS THE LOG, LOGBOOK MENU.
ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.
EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.
NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…
AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. Predict DepthPO2 Set Point Predict NDC Time (Time you can Stay at predict Depth Without Decompression) THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET.
PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF. PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME.
Mode Blend Indicator (P1 = 1 PO2) Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN. THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE.
THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.
WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash
THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.
WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE SETTINGS ARE AS INTENDED.
IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..
Conservatism set to 15% THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.
A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 & 3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1 A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE PO2 IN BLEND #1.
Blend #1 set to 0.70 ATA FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE PO2 IN BLEND #1 FROM 0.50 TO 1.50 ATA.
THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.
THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.
On Time set to 10 seconds THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.
THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number
TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001
IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.
OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES
PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A NORMAL DIVE
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) PO2 in ATA (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE
PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A DECO DIVE
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % PO2 in ATA (Blend #1 Set Point) FOR A DECO DIVE
YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.
A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT FIRST CLICK ON “PRODUCT MANUALS.”
COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING” YOUR COMPUTER. VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR MULTIPLE ENRICHED AIR NITROX APPLICATIONS.
HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE! Click on the door to go back to the main selection screen or click on the stop sign to exit.
THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE TWO PO2 COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.
SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1
SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1
SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1
SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1
THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.
AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = bars = )
UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. MAIN SCREEN ALTERNATE SCREEN
IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)
ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % PO2 in ATA (Of Blend #1 Set Point)
IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.
LET’S GO DIVING
AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.
IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.
DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.
Water Temperature Current DepthCurrent FO2 Bottom Time (so far this dive) NDC Time Remain (Time you can stay At current depth without Decompression) Ascent Rate (1 bar = fpm) MAIN SCREEN VISIBLE DURING A DIVE Note NDC Legend
ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE PO2 in ATA (Of Current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive)
A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED
SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.
COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE
WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE
THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE
IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend
THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression
Deco Ceiling IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES. NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)
ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION PO2 in ATA (Of current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive) Water Temperature
THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST DIVE INTERVAL HAS PASSED.
DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)
SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT
THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.
TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.
NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE TEN PROGRAMMING MENUS.
WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR SELECTING EITHER THE FO2 OR PO2 OPERATING MODE. FO2 SCREEN PO2 SCREEN
TOUCH OR BRIDGE CONTACTS 1 AND 2 AGAIN WITH A COIN. THE SECOND MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.
ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.
THE FORTH COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)
Conservatism set to 15% THE NEXT 1&2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.
THE SIXTH TOUCH BRINGS UP THE PO2 1 MENU FOR SETTING BLEND#1 PO2. Blend #1 set to 0.70 ATA
THE NEXT TOUCH BRINGS UP THE PO2 2, DECO BLEND PO2 MENU. Deco Blend set to 1.30 ATA
THE EIGHTH TOUCH BRINGS UP THE dEC b, DECO BLEND TIME BENCHMARK MENU. Deco Blend Time Benchmark set to 600 minutes SO WHAT IS A BENCHMARK ?
THE NEXT TOUCH BRINGS UP THE dEC d, DECO BLEND DEPTH BENCHMARK MENU. Deco Blend Depth Benchmark set to 0 feet SO WHAT IS A BENCHMARK ?
THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU. On Time set to 10 seconds
THE TENTH TOUCH BRINGS THE LOG LOGBOOK MENU.
ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.
TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS. EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES.
NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…
AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. Predict DepthPO2 Set Point Predict NDC Time (Time you can Stay at predict Depth Without Decompression) THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET.
PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF. PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME.
THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE. Mode Blend Indicator (P2 = 2 PO2) BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN. Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in %
THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.
WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash
THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.
WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU. WHEN THIS HAPPENS, THE LAST VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS ALWAYS RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE MENUS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE LIMITS ARE AS INTENDED.
IF SO…FOLLOW THE SAME PROCEDURE TO ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..
THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF CONSERVATISM. Conservatism set to 15%
A SIMILAR SEQUENCE OF TOUCHING CONTACTS 1 & 2 WITH A WET FINGER AND 2&3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGIT OF ADDITIONAL CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE PO2 VALUE FOR BLEND #1.
Blend #1 set to 0.70 ATA FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO CHANGE THE PO2 IN BLEND #1 FROM 0.50 TO 1.50 ATA.
THE NEXT 1 & 2 COIN TOUCH WILL END Blend #1 PO2 SETTING AND BRING UP THE PO2 2 MENU WHERE YOU SET THE PO2 FOR THE DECO BLEND.
SET YOUR DECO BLEND PO2 IN ATA ANYWHERE FROM 0.50 TO Deco Blend set to 1.30 ATA ANOTHER 1 & 2 COIN TOUCH AND YOU WILL COME TO THE Dec b MENU WHERE YOU SET THE DECO BLEND TIME BENCHMARK.
WITH THE SAME SEQUENCE OF 1 & 2 WET FINGER TOUCHES AND 2 & 3 COIN TOUCHES, YOU SET THE DECO BLEND TIME BENCHMARK FROM 10 TO 999 MINUTES Deco Blend Time Benchmark set to 70 minutes SO WHAT IS A BENCHMARK ?
THE NEXT CONTACT 1 & 2 COIN BRIDGE WILL TAKE YOU TO THE dEC d MENU WHERE YOU WILL BE ABLE TO CHANGE THE DECO BLEND DEPTH BENCHMARK.
FOLLOW THE SAME PROGRAMMING PROCEDURE TO CHANGE THE DECO BLEND DEPTH BENCHMARK FROM 0 TO 99 FEET. Deco Blend Depth Benchmark set to 20 feet SO WHAT IS A BENCHMARK ?
THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.
THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.
On Time set to 10 seconds THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.
THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number
TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001
IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.
OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES
PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A NORMAL DIVE
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) PO2 in ATA (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE
PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive fpm) FOR A DECO DIVE
ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % PO2 in ATA (Blend #1 Set Point) FOR A DECO DIVE
YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.
A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT FIRST CLICK ON “PRODUCT MANUALS.”
HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE! Click on the door to go back to the main selection screen or click on the stop sign to exit.