Feedback Control system

Slides:



Advertisements
Similar presentations
ERT 210 Process Control & dynamics
Advertisements

PID Controllers and PID tuning
Modern Control Systems (MCS)
Chapter 4: Basic Properties of Feedback
دکتر حسين بلندي- دکتر سید مجید اسما عیل زاده
CHAPTER V CONTROL SYSTEMS
LECTURE#10 PID CONTROLLER
The Proportional-Integral-Derivative Controller
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS
Chapter 7 System Compensation (Linear Control System Design)
Feedback Controllers Chapter 8
Chapter 10 – The Design of Feedback Control Systems
Chapter 10 – The Design of Feedback Control Systems PID Compensation Networks.
ECE 4951 Lecture 5: PID Control of Processes. PID Control A closed loop (feedback) control system, generally with Single Input-Single Output (SISO) A.
Controller Tuning: A Motivational Example
Transient and steady state response (cont.)
Process Control Instrumentation II
Prof. Wahied Gharieb Ali Abdelaal Faculty of Engineering Computer and Systems Engineering Department Master and Diploma Students CSE 502: Control Systems.
Feedback Controllers Chapter 8.
Design of Control Systems Cascade Root Locus Design This is the first lecture devoted to the control system design. In the previous lectures we laid the.
LECTURE#11 PID CONTROL AUTOMATION & ROBOTICS
Chapter 7 PID Control.
Controlling Systems Using IT (Level 3) Lecture – 1030 Thursday 23/04/2015 Boston College (Rochford Campus)
Proportional/Integral/Derivative Control
Lecture 5: PID Control.
Dynamic analysis of switching converters
Ch. 6 Single Variable Control
Cascade and Ratio Control
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
Chapter 3 mathematical Modeling of Dynamic Systems
Model Reference Adaptive Control (MRAC). MRAS The Model-Reference Adaptive system (MRAS) was originally proposed to solve a problem in which the performance.
PID Controller Design and
Control Systems and Adaptive Process. Design, and control methods and strategies 1.
Low Level Control. Control System Components The main components of a control system are The plant, or the process that is being controlled The controller,
Feedback Controllers Chapter 7.
1 Chapter 11 Compensator Design When the full state is not available for feedback, we utilize an observer. The observer design process is described and.
Control Theory Control System Objectives  Establish a final condition  Provide safe operation  Eliminate the human element  Assure economical operation.
Design Realization lecture 22
University of Virginia PID Controllers Jack Stankovic University of Virginia Spring 2015.
PID CONTROLLERS By Harshal Inamdar.
ERT 210/4 Process Control Hairul Nazirah bt Abdul Halim Office: CHAPTER 8 Feedback.
Chapter 8 Feedback Controllers 1. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control.
Control systems KON-C2004 Mechatronics Basics Tapio Lantela, Nov 5th, 2015.
Lecture 25: Implementation Complicating factors Control design without a model Implementation of control algorithms ME 431, Lecture 25.
Miss Hairul Nazirah bt Abdul Halim
Lec 11. Common Controllers Some commonly used controllers –Proportional Controller –Integration Controller –Derivative Controller Reading: 5-8. TexPoint.
Lecture 17: Introduction to Control (part III)
Chapter 6: Frequency Domain Anaysis
Digital Control CSE 421.
Features of PID Controllers
Chapter 4 A First Analysis of Feedback Feedback Control A Feedback Control seeks to bring the measured quantity to its desired value or set-point (also.
Feedback Controllers Chapter 8
Control Loops Tune a Fish. Control Loops Tuning of a control loop involves selecting loop parameters to ensure stable control under all operating conditions.
Lecture 9: PID Controller.
SKEE 3143 Control Systems Design Chapter 2 – PID Controllers Design
BIRLA VISHWAKARMA MAHAVIDHYALAYA ELECTRONICS & TELECOMUNICATION DEPARTMENT o – ANKUR BUSA o – KHUSHBOO DESAI UNDER THE GUIDENCE.
Vision Lab System VISION SYSTEM Chapter 9. Design via Root Locus Youngjoon Han
1 PID Feedback Controllers PID 反馈控制器 Dai Lian-kui Shen Guo-jiang Institute of Industrial Control, Zhejiang University.
Process Control. Feedback control y sp = set point (target value) y = measured value The process information (y) is fed back to the controller The objective.
EEN-E1040 Measurement and Control of Energy Systems Control I: Control, processes, PID controllers and PID tuning Nov 3rd 2016 If not marked otherwise,
Digital Control CSE 421.
Feedback Controllers Chapter 8
CHAPTER V CONTROL SYSTEMS
Chapter 7 The Root Locus Method The root-locus method is a powerful tool for designing and analyzing feedback control systems The Root Locus Concept The.
Process Control Engineering
Features of PID Controllers
Feedback Controllers Chapter 8
PID Controller Design and
The Design of Feedback Control Systems
Presentation transcript:

Feedback Control system

• Reduce the sensitivity of a system’s Advantages of Feedback in Control Compared to open-loop control, feedback can be used to: • Reduce the sensitivity of a system’s transfer function to parameter changes • Reduce steady-state error in response to disturbances, • Reduce steady-state error in tracking a reference response (& speed up the transient response) • Stabilize an unstable process

Disadvantages of Feedback in Control Compared to open-loop control, • Feedback requires a sensor that can be very expensive and may introduce additional noise • Feedback systems are often more difficult to design and operate than open-loop systems • Feedback changes the dynamic response (faster) but often makes the system less stable.

Controlled system Control system

Control Modes • There are a number of ways by which a control unit can be react to an error signal and supply an output for correcting elements: • 1- two step mode: the controller is an ON-OFF correcting signal • 2- The proportional Mode: the controller produce a control action proportional to the error. • 3: the derivative mode D: the controller produces a control action proportional to the rate at which the error is changing. When there is a sudden change in the error signal, the controller gives alarge correcting signal, when there is a gradual change only a small correcting signal is produces. Normally used in conjunction with proportional control

Control Modes • 4- The integral mode: the control action proportional to the integral of the error thus a constant error signal e=constant produces an increasing correcting signal • 5- Combination of Modes PD, PI, PID • A controller can achieve these modes by means of pneumatic circuit, analogue electronic circuits involving opamp or by the programming of a microprocessor or computer system

An example of two step mode of control is the bimetallic thermostat that might be used with a simple temperature control system. Two-step control

Two step mode • Consequences: • To avoid continuous switching ON and OFF on respond to slight change, two values are normally used, a dead band is used for the values between the ON and OFF values • Large dead band implies large temp. fluctuations • Small dead band increase switching frequency

Thyrester) Two step mode •The bimetallic element has permanent magnet for a switch contact, this has the effect of producing a dead band. Fast ON-OFF control can be used for motor control using controlled switching elements (MOSFET, Thyrester) Bolton, Mechatronics PowerPoints, 4th Edition, © Pearson Education Limited 2008

Proportional Mode • With the two step method of control, the controller output is either ON or OFF signal, regardless of the magnitude of error. • With proportional control mode, the size of the controller output is proportional to the size of the error. The bigger the error the bigger the output from the controller • Controller output u(t) = Kp e • Or in s domain U(s)=KpE(s)

Electronic Proportional Mode A summing opamp with an inverter can be used as proportional controller Proportional controller

Electronic Proportional Mode

Electronic Proportional Mode Proportional controller for temperature control

System response to proportional control

Derivative control mode As soon as the error signal begins to change, there can be quite a large controller output, thus rapid initial response to error signal occur In Figure the controller output is constant is constant because the rate of change is constant.

Derivative control mode • - They do not response to steady- state error signal, that is why always combined with P- controller • P responds to all error • D responds to rate of change • Derivative action can also be a problem if the measurement of the process variable gives a noisy signal, the rapid fluctuations of the noise resulting in outputs which will be seen by the controller as rapid changes in error and so give rise to significant outputs from the controller.

Derivative control mode The Figure shows the form of an electronic derivative controller circuit, it composed of two operational amplifier: integrator + Inverter Derivative controller

PD controller

PD controller due to the derivative followed by the gradual change due to proportional action. This form of control thus deal with fast process changes

Integral control

Figure shows the action of an integral controller when there is a constant error input to the controller When the controller output is constant, the error is zero; when controller output is varies at a constant rate, the error has a constant value. Integral control

The integrator is connected to the error signal at time t, while Integral control The integrator is connected to the error signal at time t, while the second integrator is connected to the error at t=0- i.e. (t-Ts) Electronic Integral controller

PI control

PI control

PID Controller

PID circuit

PID & Closed-loop Response Risetime Maximum overshoot Settling time Steady- stateerror P Decrease Increase Small change I Eliminate D • Note that these correlations may not be exactly accurate, because P, I and D gains are dependent of each other.

PID Response P PD PI PID

• Increasing the proportional feedback gain PID Conclusions • Increasing the proportional feedback gain reduces steady-state errors, but high gains almost always destabilize the system. • Integral control provides robust reduction in steady-state errors, but often makes the system less stable. • Derivative control usually increases damping and improves stability, but has almost no effect on the steady state error • These 3 kinds of control combined from the classical PID controller

Digital closed-loop control system A digital controller basically operates through the following cycle 1- samples the measured value 2- compares it with the set value and establishes the error 3- carries out calculation based on the error value and store values of previous inputs and outputs to obtain the output signal 4- sends the output signal to the DAC. 5- Waits until the next samples time before repeating the cycle.

Digital PID Controller

System with velocity feedback: (a) descriptive diagram of the system, (b) block diagram of the system

Self-tuning

Model-referenced control