MINERvA Main INjector ExpeRiment for -A is the symbol for the neutrino. The beam that is sent to MINERvA is made out of neutrinos. In chemistry, an A stands.

Slides:



Advertisements
Similar presentations
HEP Experiments Detectors and their Technologies Sascha Marc Schmeling CERN.
Advertisements

COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results.
PIXE: Data Analysis What the data can (and cannot) tell us. Larry Lamm PIXE Seminar Winter 2008.
Introduction into LS theory and practice. Agenda  Energy deposition  Overview of the LSC process  Theory of operation  Quenching  Machine  Uses.
Detecting Giant Monopole Resonances Peter Nguyen Advisors: Dr. Youngblood, Dr. Lui Texas A&M University Energy Loss Identifying The Particles Discovered.
How to Build a Neutrino Oscillations Detector - Why MINOS is like it is! Alfons Weber March 2005.
An accelerator beam of muon neutrinos is manufactured at the Fermi Laboratory in Illinois, USA. The neutrino beam spectrum is sampled by two detectors:
3/1/05 Status of the SHBD for the NUMI OPERA exposure D. Autiero IPN Lyon  Reminder about the proposed setup for the SHBD  Status of the sub-detectors.
The MINOS Experiment Andy Blake Cambridge University.
The Design of MINER  A Howard Budd University of Rochester August, 2004.
An Introduction to CLEO Lora Hine – Education & Outreach Coordinator at the Lab for Elementary-Particle Physics Laura Fields – CLEO Graduate Student at.
Detecting Giant Monopole Resonances Peter Nguyen Advisors: Dr. Youngblood, Dr. Lui Texas A&M University.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
ZEUS Calorimeter (1) At HERA high energetic electrons (e) collide with high energetic protons (P). The ZEUS detector measures the properties of the particles.
Nuclear Power.
Have a Seat and Get out your homework that is on the overhead.
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
Lens ALens B Avg. Angular Resolution Best Angular Resolution (deg) Worst Angular Resolution (deg) Image Surface Area (mm 2 )
Jimmy McCarthy International Cosmic Ray Day 26 th September 2012 Detecting Cosmic Rays.
Physics Topics in MINER A David Boehnlein - Fermilab for the MINERvA Collaboration Overview of MINERvA The high intensity of the NuMI beamline at Fermilab.
CMS Masterclass. It’s the dawn of an exciting age of new discovery in particle physics! At CERN, the LHC and its experiments are underway. ATLAS and.
CMS Masterclass It’s a time of exciting new discoveries in particle physics! At CERN, the LHC and its experiments are underway. ATLAS and CMS, the.
Cosmic Rays: Ever Present and Useful Anthony Gillespie Denbigh High School Mentor: Dr. Douglas Higinbotham Cosmic Rays Using the Cosmic Rays Current Research.
1 Chemistry Chapter 3 Atomic Structure and the Nucleus World of Chemistry Zumdahl Last revision Fall 2008.
Status of the NO ν A Near Detector Prototype Timothy Kutnink Iowa State University For the NOvA Collaboration.
1 Chemistry Chapter 11 Electron Configuration and the Periodic Table World of Chemistry Zumdahl Last revision Fall 2008.
MINER A (FNAL E938) Gabriel Niculescu, JMU MINERA web site: Miner a Main Injector MINOS Near Detector NuMI Beam Where?  FERMILAB.
Walkway Detector Shaft Poster Detector components Event display Orientation.
Radioactivity!.
Muon Identification in the MINOS Calibration Detector Anna Holin 05 December 2005 University College London.
SEM Scanning Electron Microscope
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
Detector Monte-Carlo ● Goal: Develop software tools to: – Model detector performance – Study background issues – Calculate event rates – Determine feasibility.
W path data analysis International Masterclasses CERN, March 2012.
CEBAF The Continuous Electron Beam Accelerating Facility (CEBAF) at JLab in Newport News, Virginia, is used to study the properties of quark matter. CEBAF.
II. DETECTORS AND HOW THEY WORK
E. W. Grashorn and A. Habig, UMD, for the MINOS Collaboration The Detectors of The Main Injector Neutrino Oscillation Search (MINOS) Experiment The MINOS.
MINER A Main INjector ExpeRiment for v-A Active segmented scintillator detector: 5.87 tons Nuclear targets of C, Fe and Pb, Water, Helium.
What Are They Doing at Fermilab Lately? Don Lincoln Fermilab.
Particle Detectors January 18, 2011 Kevin Stenson.
Chapter V Radiation Detectors.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
MINER A at the Triple Point: Three Phases at once Deborah Harris AEM August 31, 2009.
CMS Masterclass It’s a time of exciting new discoveries in particle physics! At CERN, the LHC succesfully completed Run I at 8 TeV of collision.
Modern Physics Wave-Particle Duality Model of the atom Radioactivity / Four Forces of nature.
Light 1)Electrons (charged –1 each, with a mass of 1/1836 amu each) surround the nucleus of the atom in distinct energy levels. Electrons occupy the.
The NSCL is funded in part by the National Science Foundation and Michigan State University. Results: the neutron source was located 19.9 inches from the.
SHIP calorimeters at test beam I. KorolkoFebruary 2016.
Scanning Electron Microscope Eee-Jay Rodriguez. The Structure of the Microscope Inside Outside.
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
Nuclear Chemistry.
MoNA detector physics How to detect neutrons. Thomas Baumann NSCL.
MINERVA Z Mass Exercise
CMS Masterclass 2012.
CMS Masterclasses 2017 S’Cool LAB
PAN-2013: Radiation detectors
Gamma Rays Detection LNF – | INSPYRE school Danilo Domenici
Chris Smith California Institute of Technology EPS Conference 2003
Cosmic Ray Showers Cosmic ray activity Figure 3:
Scintillation Counter
CMS Masterclass 2013.
When this happens... We see this... 12/6/2018 Steve Wotton.
The Hall C Heavy Gas Cerenkov
Oct 10, 2018 Muhammad Qasim Abdul Wali Khan University, Department of Physics, Mardan, Pakistan by.
CMS Masterclass 2017.
Photomultiplier (PMT) Tubes
Do Now – Copy this into the next clean “right” page in your journal…start after last weeks notes on lab safety. ATOM- Smallest piece of an element Nucleus-
MINERvA Masterclass Start-up
MINERvA Masterclass Start-up
Presentation transcript:

MINERvA Main INjector ExpeRiment for -A is the symbol for the neutrino. The beam that is sent to MINERvA is made out of neutrinos. In chemistry, an A stands for the symbol representing the mass number of the atom (the number of protons and neutrons). This symbolizes the different types of atoms found in MINERvA. Make sure to pay attention and/or take good notes! There will be a short quiz at the end!

What is MINERvA? A neutrino scattering experiment Uses the NuMI beam at Fermi Lab Seeks to measure low energy neutrino interactions (interactions of protons, muons and pions in particular) MINERvA sits directly in front of the MINOS Near detector which studies high energy particles

How is MINERvA constructed? Here is one plane of MINERvA being prepared for installation. There are around 200 planes in MINERvA (it changes with every modification). The detector is in the shape of a hexagon. The center of the plane will also be filled with detection material. MINERvA is made of many planes of nuclear targets and scintillator material. The nuclear targets are dense materials which offer the particles a large nucleus to interact with. The scintillator material detects particles as they travel through the plane.

Specialized Areas of MINERvA Beam enters here There are three general areas to the MINERvA detector. The fully active target contains lots of scintillator material necessary to detect specific particles. The ECAL contains material for detecting particles such as electrons and photons. The HCAL is specialized to detect particles such as pions and protons. You can see that there are both ECAL and HCAL areas in both the sides and back of MINERvA.

The ECAL and HCAL Modules The ECAL is located in the outside border of each plane and also in the orange colored portion in the diagram. The HCAL modules are also located in the outer border of the plane and in the purple portion of the diagram. A typical HCAL Module A typical ECAL Module HCAL ECAL

The Fully Active Target – The Fiducial Zone This area is the “sweet spot” of the detector. It contains three different directional layers of triangular graphite material. This material is the scintillating material. It carries the energy released by the particles into the detector to tiny fibers inside the graphite which connect to photomultipliers which send the data to the computers. The computers can tell us even more about the particles. We label these layers the X, U and V views. Due to the three layers, we can “see” where the events happened in the detector. ALL THREE LAYERED TOGETHER

The Scintillator Strips These are small strips which are triangular shaped and are formed in long pieces. These strips take the energy from a particle interacting with the material in the detector and transform it into light. The wavelength shifting fiber runs through the length of the scintillator and collects the light. The light is then sent to the PMTs. This shows how the scintillator strips fit together in a panel. Because of their shape, each particle will leave energy in at least two strips. This helps the computers to identify more accurately where the event happened in the detector. Here is the “big picture”. You can see the scintillator and wavelength shifting fiber on left connected to the PMT box. The PMTs are photomultipliers which transform the light energy into electricity and strengthen the signal. This needs to take place since the amount of light emitted per event is very small.

The PMT’s Next, the computers analyze the signal and provide us with information about the event. This is a very simplified diagram of a photomultiplier (PMT). A photon enters the photomultiplier through the glass surface and hits the photo-cathode, which is placed on the inner surface of the glass. The photo-cathode hit by the photon emits an electron. Inside the photomultiplier there is a vacuum. The electron is attracted and accelerated to the first dynode, which is charged positively by a high voltage. As it hits it with great energy, the dynode emits several electrons, which are then attracted to a second dynode, which has even higher positive electric potential. This process repeats many times. At the last dynode we have a really huge number of electrons. This way the signal of a single electron was enormously amplified. Incoming photon 10 6 photons

The Data Analysis This is a sample of one piece of data that the computer provides us. Here you can see the three different views in the X, U and V directions. We will be using this data in our activities.

The Quiz!! Number your paper 1 – 8 giving each answer plenty of room – some questions have more than one answer. Yes, there are only 8 questions!! 1. What does the MINERvA detector measure? 2. What shape are each of the planes in MINERvA? 3. What is a scintillator strip? 4. What is the shape of a scintillator strip? 5. How many specialized areas are in MINERvA? 6. Name three types of material in MINERvA. 7. What is a wavelength shifting fiber? 8. What does a PMT do?