Engineering Division 1 M321/M331 Mirror Switchyard Design Review Tom Miller 11-29-2006.

Slides:



Advertisements
Similar presentations
An Axtrusion Based Lathe
Advertisements

Definition I. Beams 1. Definition
Power Screw and Springs
New Non-Contact, Laser-Based Gauge for Measuring Length and Speed of Gypsum Board Stuart Manser Beta LaserMike.
Mechanical Engineering Design Review BL ARPES Endstation Derek Yegian, Jonathan Denlinger, Keith Franck 4/18/2008.
1 Grating Mount Requirements Weight:< 75 Lbs including grating (43.1 Lbs) Size:Fit within structural envelope. 1.5” for cell behind grating. Alignment:Adjust.
Transmission Machine Components
MECHANICAL DESIGNS. What is mechanical design? All the mechanical hardware used in the machine is called mechanical design. Precision machines are essential.
Multipole Girders - Alignment & Stability (Multipole Girder Alignment technology & R&D) S. Sharma ASD: J. Skaritka, D. Hseuh, V. Ravindranath, G. Miglionico,
Wed 15 Jul 2009 ATF2 weekly meeting Oxford MONALISA 1 MONALISA at ATF2 First installation report 15 July 09.
Time to Derive Kinematics Model of the Robotic Arm
Progress on the MICE 201 MHz Cavity Design Steve Virostek Lawrence Berkeley National Lab RF Working Group Fermilab August 22, 2007  automatic.
NGAO Alignment Plan See KAON 719 P. Wizinowich. 2 Introduction KAON 719 is intended to define & describe the alignments that will need to be performed.
Tagger and Vacuum Chamber Design. Outline. Design considerations. Stresses and deformations. Mechanical assembly.
Robert Ruland Installation Alignment -Magnetic Measurements – Fiducialization April 7-8, 2005 FAC Meeting 1 Installation Alignment,
Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center LCLS Undulator Physics.
LIGO-G D 1 MEPI electroMagnetic External Pre-Isolator Backup alternative to the Hydraulic actuator approach Goal: maximum commonality with HEPI.
Tom McCarville Oct 30, 2007 HOMS/SOM Design Status 30 Oct 2007 This work performed under the auspices of the U.S. Department of Energy.
U U 1 Excitation of Structural Resonance Due to a Bearing Failure Robert A. Leishear David B. Stefanko Jerald D. Newton IMECE 2007 ASME, International.
Yury Gavrikov 25/03/  I met with two very nice g…oniometers 3 Because we decided to adapt their for a new experiment.
A Preliminary Design of the Rotator for the DES Simulator Stand February 28, 2008 Edward Chi Fermilab/PPD/MD.
H. MAINAUD DURAND on behalf of the CLIC active pre-alignement team with 3D views and data from Hubert Gerwig, Richard Rosing and Juha Kemppinen Pre-alignment.
PEEM III Endstation Design Review
Integration and Alignment of Optical Subsystem Roy W. Esplin Dave McLain.
DELTA Quadrant Tuning Y. Levashov, E. Reese. 2 Tolerances for prototype quadrant tuning Magnet center deviations from a nominal center line < ± 50  m.
DESIGN OF A TESTING MACHINE FOR MICRO-DEVICES Follow up to Clément Gabry’s master thesis on Structural Resistance of Silicon Membranes 1 12/10/2014CERN.
Laser Notcher Status Dave Johnson PIP Meeting April 29, 2014.
MUON_EDR-06 (Alignment) Enrique Calvo Alamillo February 28-March 1, 2002 Link Mechanics: Status.
Alignment and Beam Stability
GSA basic concepts GSA Essentials.
MCAO Adaptive Optics Module Mechanical Design Eric James.
Engineering: NAHUAL Ireland Acquisition Camera, Focal Plane Mechanisms and Layout Tully Peacocke, National University of Ireland Maynooth Carlos del Burgo,
MARS 2 Design Review-Optomechanical Review 07 Nov 2002 GLW1 MARS 2 Mechanical Design Review.
RFCC Module Design Update  automatic tuners  cavity suspension  cavity installation Steve Virostek Lawrence Berkeley National Lab MICE Collaboration.
ATLAS Pixel Detector Discussion of Tolerances November 12, 1998 Pixel Mechanics D. Bintinger, LBNL E. Anderssen, LBNL/CERN.
MERLIN BEAMLINE RIXS refocusing mirror system D. Yegian
IFE Plant Structural Concepts Including Shielding and Optical Stability Requirements Thomas Kozub, Charles Gentile, Irving Zatz - PPPL.
Optical surface measurements for very large flat mirrors Jim Burge, Peng Su, and Chunyu Zhao College of Optical Sciences University of Arizona Julius Yellowhair.
Uncertainty issues in Micro/Nano Manipulation by Parallel Manipulator
Design of a Lightweight Mounted Tip/Tilt Mirror
SUSPENSIONS Pisa S.Braccini C.Bradaschia R.Cavalieri G.Cella V.Dattilo A.Di Virgilio F.Fidecaro F.Frasconi A.Gennai G.Gennaro A.Giazotto L.Holloway F.Paoletti.
Permanent Magnet Quadrupoles for the CLIC Drive Beam Jim Clarke, Norbert Collomb, Neil Marks, James Richmond, and Ben Shepherd STFC Daresbury Laboratory,
BEPCII Prealignment Installation Survey and Alignment Accelerator Center of IHEP Xiaolong Wang
Instrumentation and Measurements Class 3 Instrument Performance Characteristics.
MERLIN RIXS Endstation Design Review
N A S A G O D D A R D S P A C E F L I G H T C E N T E R I n t e g r a t e d D e s i g n C a p a b i l i t y / I n s t r u m e n t S y n t h e s i s & A.
Engineering Division 1 HHMI 8.2.X Endstation Modification Review Allan DeMello 12/13/2006.
LATHE VIBRATIONS ANALYSIS ON SURFACE ROUHHNESS OF MACHINED DETAILS LATHE VIBRATIONS ANALYSIS ON SURFACE ROUHHNESS OF MACHINED DETAILS * Gennady Aryassov,
The MesoMill™ An Off-The-Shelf Small Milling Machine By Roger Cortesi MIT Precision Engineering Research Group.
Flexure Mounts For High Resolution Optical Elements
Magnetic Field Stability Measurements Joe DiMarco 23Oct07.
Repeatability and control in nanoimprint lithography Sarah Felix 4/14/08 EE C235 - Nanoscale Fabrication.
Moller SC Magnet Status. Installed Magnet is installed and cooled down EPICS controls tested and working Magnet has been ramped several times in its current.
SPS movable table Joanna Swieszek, Kurt Artoos (EN-MME) 14/04/2016.
CERN –GSI/CEA MM preparation meeting, Magnetic Measurements WP.
FP420 Hybrid Mechanical Design Ray Thompson / Manchester Manchester Xmas O7 Ray Thompson Julian Freestone, Andy Elvin.
Review of Alignment Tolerances for LCLS-II SC Linac Arun Saini, N. Solyak Fermilab 27 th April 2016, LCLS-II Accelerator Physics Meeting.
Two-beam module layout
Tutorial On Fiducialization Of Accelerator Magnets And Undulators
CMM Coordinate-Measuring Machine
Correlated Misalignments Studies for LCLS-II SC Linac
CLIC magnets precise positioning
For Discussion Possible Beam Dynamics Issues in ILC downstream of Damping Ring LCWS2015 K. Kubo.
Stages for the SSW translation system for PACMAN
Concepts and Requirements for GIMM Structures
Pierre-Alexandre Thonet
By Arsalan Jamialahmadi
WP-73 TDR ART Review Report: Hard X-Ray Monochromator
MicroE Systems Mercury II™ Family of Encoders
Beam Finder Wire (BFW) Status
Presentation transcript:

Engineering Division 1 M321/M331 Mirror Switchyard Design Review Tom Miller

Engineering Division 2 Basic layout of M321/M331 mirror switchyard

Engineering Division 3 x yz M321 M331 Figure 4: Coordinate system of mirror switchyard Alignment / stability tolerance and mechanical steps for M321 and M331 Dimension Alignment toleranceMechanical stepStability tolerance X 100  m38  m19  m Y1mmN/A0.5mm Z 300  m N/A 150  m xx 1o1o N/A0.5 o yy 1mrad 30  rad15  rad zz 24  rad N/A 12  rad x yz M321 M331 Figure 4: Coordinate system of mirror switchyard Alignment, resolution and stability requirements (Roll) (Pitch) (Yaw)

Engineering Division 4 Basic Optic Design Single optic for M321 and M331 with diagnostic pass – through. Mounting details are omitted One optic versus two Single optic advantages: No mechanisms for alignment between M321 & M331 Lighter and more rigid optic and mounting for better stability Smaller required translation due to compact design Faster setup and commissioning due to fixed angle between M321 & M331 Single optic disadvantages: Up-front cost of the optic. This can be offset by reduced mechanism and setup costs if optics are not routinely damaged Manufacturing tolerances on the relationship between the two optical surfaces must be good for quick replacement of the optic.

Engineering Division 5 Maximum Required Motions Translations(x): (Single optic) RIXS Rotated: 12.01mm outbound ARPES Rotated: 17.97mm inbound Total: 29.98mm (nominal) Pitch (Theta y ): (Single or dual optics, RIXS & ARPES) High Res grating: +/-259 microradians High Flux grating: +/-168 microradians Roll (Theta z ): (Single or dual optics, RIXS & ARPES) +/- 5 milliradians RIXS rotatedARPES rotated

Engineering Division 6 Mechanism Fundamentals Initial concept: Mount the optic(s) rigidly in the chamber and translate the chamber with a single slide and pitch and roll with struts to steer the beam. Advantage: Familiar approach Easy installation survey. The optic(s) can be accurately fiducialized in a lab and those numbers used for installation alignment. Disadvantages: Input and output bellows are required. Large and variable off-axis forces act on the translation slide and rotation mechanisms If pumping is added to the chamber, the pump must move with the chamber or be bellows isolated. This will result in a large mass offset from the slide or more non- constant bellows forces. Both solutions result in poorly placed variable forces. Pitch and roll motions intrinsically couple to all other motions. Parasitic motions from variable off-axis forces may make high resolution encoder readings meaningless

Engineering Division 7 Mechanism Fundamentals New concept: Mount the chamber rigidly and move the optic(s) Advantages: Bellows forces are small and self-cancelling Pitch corrections are nominally independent of roll Translations are nominally independent of pitch and roll Any force required for translation is small and almost directly in line with the linear bearings in the stages. All sources of backlash in the mechanism are spring loaded in the axis of freeplay. Pitch and roll are flexure-based motions and therefore very repeatable Large pumps can be mounted beneath the tank with no effects on motion. Small off-axis forces will make encoder readings more meaningful The moving masses are small and the mechanisms optimized for stiffness. The vibrational modes of the mechanism are thus above 200Hz. All mechanism parts are stainless steel or cast iron. This should yield good thermal stability.

Engineering Division 8 Mechanism Fundamentals New concept: Mount the chamber rigidly and move the optic(s) Disadvantages: Unfamiliar design Roll couples to pitch and translation. 1 milliradian of roll induces 200 microradians of pitch for ARPES, 100 microradians of pitch for RIXS and 0.13 microns of translation. Intrinsic roll errors should be very small, and thus the roll corrections should also be small, so pitch coupling should not be a problem. Translation coupling will be insignificant. Pitch couples to translation. 250 microradians of pitch results in 9 microns of translation at the nominal reflection point. The large pitch changes required for grating selection also have an associated ~1.5mm translation, so this number is acceptable. Installation surveys of the optic will be relatively imprecise. The orientation of the optic to outside fiducials must be determined after the optic is mounted in the tank. The in-vacuum fiducials are close together and difficult to survey in the tank.

Engineering Division 9 Mechanism Overview

Engineering Division 10 Translation Mechanism

Engineering Division 11 Chamber pass-through

Engineering Division 12 Roll Mechanism

Engineering Division 13 Pitch Mechanism

Engineering Division 14 Mirror details

Engineering Division 15 Center Section

Engineering Division 16 Pitch Hinge Details

Engineering Division 17 Micro-e Encoder Scale

Engineering Division 18 Center Section Mounting

Engineering Division 19 Pitch Mechanism First mode

Engineering Division 20 Spring stress at 1mRad pitch

Engineering Division 21 Demagnification spring deflection with 1mRad pitch

Engineering Division 22 Roll Mechanism first mode

Engineering Division 23 Cost estimate Fab and purchases: $78,000 Assembly (200hrs) : $20,000 Total: $100k