DinBox M36 Remote monitoring, alarming & control device Professional embedded SMS application 07/05/2010 Jean-Philippe Aerts.

Slides:



Advertisements
Similar presentations
General System Configuration
Advertisements

Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
Helping you provide a higher standard of care With a nurse call system from TotalConnect you can select any number and combination of resident notification.
OfficeTrack Fuel and other Static Sensors Control.
G-Eye Extending your monitoring & control capabilities
Energy and Water Data Capturing and Monitoring Data and What It Can Do for You! Southface Lunch and Learn, June 18 th, 2013 Scott Kale – VP Sales, WaterSignal.
ONE STOP THE TOTAL SERVICE SOLUTION FOR REMOTE DEVICE MANAGMENT.
NetSure™ RDB Series.
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
IQ ™ Overspeed protection.. and more.
BPS12 Battery Power Supply. December 2003 Page 2 Better Than Standard UPS systems Longer battery life –unique charging scheme DC power output –instead.
PICNIC Demo Module 2 IP-based utility outlets 陳育瑋、方煒 台大生機系.
Increase Productivity A monitored employee is a productive employee Operational Efficiency Streamline processes between the office and the field Improve.
2N OMIKRON Multichannel Analog Gateway. Main features  Pass thru technology  Scalable solution for max. 8 analog dial-thru lines  Number of GSM channels.
PLC Based Residential Alarm System John Hiddema University of Idaho - ECE Spring 2012.
The Comfort System Product Presentation The Intelligent Home System.
NITRO Intelligent Audio Analysis System. GS-AID/GS-ADD Audio Analysis System: Audio analysis matrix system is totally new designed security management.
A solution to ATM Energy and Security Management
Application 1. To make a PC to communicate with SMS text messages over a serial GSM/GPRS-modem with mobile/cellular phones (2-way). Application 2. To interface.
Monitoring System Monitors Basics Monitor Types Alarms Actions RRD Charts Reports.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
Lithium Ion and VRLA Battery Safety Monitoring for Storage and Charging Jordan Allen University of Idaho ECE Department ECE Power Lab 1.
Made in United States of America EMIT SIM emit.descoindustries.com Rev:
Overview of the 1.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
Log in username password GO create a new account remember this account.
12-/24-Port Gigabit IEEE 802.3at High Power Injector Hub HPOE-1200G HPOE-2400G.
1. Presenters: Constantine Grantcharov Ryan Burbidge 2.
The Headphones1 Trainer Training The Headphones. 2 There are three sets of headphones There are three transmitters Transmitters also act as battery chargers.
Expert Training Presentation September 2013 Rev 3 Instant Queue Manager Enterprise Click to Chat.
Introduction Save-bees’ Anti Theft Device helps professional beekeepers to locate their hives in cases of theft or unexpected relocations. It can inform.
Central Monitoring Station Marketing Dept. July 2005.
Save-bees’ solution : Consists of standalone devices that are placed in the beehives and offer accurate measurement information for The weight of the.
TVI FEATURE  16ch TVI DVR : recording, playback(16ch)  All channel support : automatic detection input for TVI 1080p/720p/960h/
How to Use the 3-Way Helper Tool Help Instructions and Screen Shots 1 GOeXfuze Help Instructions and Pictures. Copyright 2014 eXfuze LLC. VCN v1-GOEXF3WAY-USA.enu.
1 TRADITIONAL CONFIGURATION (external GSM modem) Requirements: RS232 serial communication port available on the device (built-in or added by installing.
Home Guard Security System. Introduction & Basic Ideas Home Guard Security System.
INFN-GRID Testbed Monitoring System Roberto Barbera Paolo Lo Re Giuseppe Sava Gennaro Tortone.
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
Controls EN-ICE LAV Environment Monitor Jonás Arroyo CERN EN/ICE-SCD 6 th April 2011.
Monitoring and reporting made easy… Monitoring, History and reporting Multi-Vendor connectivity Web based configuration and reporting Rule based alarm.
1 DMG900 + EXP1015 (GSM-GPRS) DMG900 + EXP1015 Sending SMS: to modify REM variables status and required plant information Receiving SMS: plant status,
DataMaster 3000 Data Acquisition and Control Software.
SECURITY. ANYWHERE, ANYTIME.. Mobeye team The company Mobeye is specialized in high quality GSM/GPRS alarm and telemetry technology. Mobeye products are.
PEPEROSSO – June 2013 – 1 ALARM SYSTEMS MANUFACTURER Effective protection of unguarded sites.
Typical M²M applications InduBox GPRS sample applications.
VEHICLE TRACKING SYSTEM VTS 1200 WIRELESS INTEGRATED PVT. LTD. VEHICLE TRACKING SYSTEM VTS 1200 WIRELESS INTEGRATED PVT. LTD.
1 ARC reporting ARCCerny Verze INTERNET ARC events reporting Control panel 3. PSTN Telephone network - CID 1. GSM network – GPRS IP CID.
HDL-MGSM.431. Description MGSM.431 is an automation module based on GSM monitoring and controlling. Being at a great distance you can operate a target.
LBS Division INDOOR POSITIONING SYSTEM Indoors Independent infrastructure that communicates via wireless connection standards: RFID Technology: Continuous.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
Update of SAM Implementation ALICE TF Meeting 18/10/07.
The Future is Now The IP Solution for Life Safety, Area of Refuge & Emergency Communications.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
For an appointment contact us on:  
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. Insert Photo Here Bulletin 193/592 E1 Plus EtherNet/IP® Side Mount Module External Presentation.
DinBox DB65 Remote monitoring, alarming & control device Professional embedded SMS application.
SAM architecture EGEE 07 Service Availability Monitor for the LHC experiments Simone Campana, Alessandro Di Girolamo, Nicolò Magini, Patricia Mendez Lorenzo,
Fire Alarm Verification CAN/ULC-S561-03
We do not have land line and would like the alarm panel to work on GSM
SMT Historical Usage Reporting Functionality Backfill Requests Interim Solution Instructions Version 6 Dated March 17, 2014.
Networking Management
Networking Management
The advantages of going wireless
Introduction; iMCB a safety monitoring and energy management system, with smart disconnect features. It has a short circuit protection, leakage protection,
void method2() { Console.WriteLine(“Method 2 was called”);
Input-Output-Process Demo
Presentation transcript:

DinBox M36 Remote monitoring, alarming & control device Professional embedded SMS application 07/05/2010 Jean-Philippe Aerts

Dinbox M36: Start-up notification SMS SMS DB65 Start-up notification (23) Vac MAINS DinBox M36 DINrail SMS-Box

Dinbox M36: Inputs (Closing Contact) Push INPUT1 CLOSED SMS SMS DinBox M36 DINrail SMS-Box

Dinbox M36: Inputs (Opening Contact) Pull INPUT1 OPENED SMS SMS DinBox M36 DINrail SMS-Box

Dinbox M36: Inputs (Power Driven Input) + - 9Vdc INPUT1 CLOSED SMS SMS DinBox M36 DINrail SMS-Box

Dinbox M36: Inputs with time driven validity Push INPUT1 CLOSED Valid from SMS SMS DinBox M36 DINrail SMS-Box

Dinbox M36: Inputs (Alarm Confirmation) ALARM1 SMS SMS Confirm ALARM1 DinBox M36 DINrail SMS-Box

Dinbox M36: Input (Status reports) SMS SMS Input1 High Input2 Low Input3 Low Input4 High DinBox M36 DINrail SMS-Box

Dinbox M36: Inputs (Usage report) Send SMS when Input is 1000 min active SMS SMS DinBox M36 DINrail SMS-Box

Dinbox M36: Outputs (Closing & Opening Contact) SMS SMS Close Output 1 DinBox M36 DINrail SMS-Box

Dinbox M36: Outputs (Closing & Opening Contact for specific duration) SMS SMS Close Output 1 5s s = seconds m = minutes h = hours d = days DinBox M36 DINrail SMS-Box

Dinbox M36: Outputs with time driven validity SMS SMS Close Output 1 Output only valid between – h DinBox M36 DINrail SMS-Box

Dinbox M36: Outputs (Closing & Opening Contact with SMS notification) SMS SMS M36 OUTPUT 1 Closed confirmation SMS DinBox M36 DINrail SMS-Box

Dinbox M36: Outputs (Status report) SMS SMS M36 OUTPUT 1 High OUTPUT 2 Low DinBox M36 DINrail SMS-Box

Dinbox M36: Outputs (Usage report) SMS SMS M36 OUTPUT min. Send SMS when output is closed for 1000 min DinBox M36 DINrail SMS-Box

Dinbox M36: Keep Alive SMS SMS M36 Loc. Brussels Installation Every week SMS I’m still alive DinBox M36 DINrail SMS-Box

Dinbox M36: Battery Alarm when Power Fails SMS SMS M36 Main power fails Battery level 80 % BATT Level Vac MAINS DinBox M36 DINrail SMS-Box

Dinbox M36: Movement Detection SMS SMS M36 Alarm Illigal movement detected. BATT DinBox M36 DINrail SMS-Box