Systematic error and double Gaussian fitting Toshi Gogami 3Apr2014.

Slides:



Advertisements
Similar presentations
Ozgur Ates Hampton University HUGS 2009-JLAB TREK Experiment “Tracking and Baseline Design”
Advertisements

Λ hypernuclea r spectroscop y at Jefferson Lab The 3 rd Korea-Japan on Nuclear and Hadron Physics at J-PARC, at Inha University in Korea 2014/3/20 – 2014/3/21.
HES-HKS & KaoS meeting Toshiyuki Gogami 18Dec2013.
14 Sept 2004 D.Dedovich Tau041 Measurement of Tau hadronic branching ratios in DELPHI experiment at LEP Dima Dedovich (Dubna) DELPHI Collaboration E.Phys.J.
Adding electronic noise and pedestals to the CALICE simulation LCWS 19 – 23 rd April Catherine Fry (working with D Bowerman) Imperial College London.
Measurement of charmonia at mid-rapidity at RHIC-PHENIX  c  J/   e + e -  in p+p collisions at √s=200GeV Susumu Oda CNS, University of Tokyo For.
Outline: 1) Experiment Setup 2) HES Geant4 Simulation 3) Missing Mass Spectra Calibration 4) Experiment status Zhihong Ye, March 16 th 2009 HU Group Meeting.
Alignment study 19/May/2010 (S. Haino). Summary on Alignment review Inner layers are expected to be kept “almost” aligned when AMS arrives at ISS Small.
 *(1520) CrossSection Zhiwen Zhao Physics 745. Λ BARYONS (S = − 1, I = 0) Λ 0 = u d s Λ(1520) D 03 I( J P ) = 0( 3/2 − ) Mass m = ± 1.0 MeV [a]
Zhihong Ye Hampton University Feb. 16 th 2010, APS Meeting, Washington DC Data Analysis Strategy to Obtain High Precision Missing Mass Spectra For E
Spectroscopic Investigation of P-shell Λ hypernuclei by the (e,e'K + ) Reaction - Analysis Update of the Jlab Experiment E Chunhua Chen Hampton.
Nov.29,2011/HU group meeting Spectroscopic Investigation of P-shell Λ hypernuclei by (e,e'K + ) - Analysis Updated Status - Chunhua Chen Hampton Universithy.
Pion test beam from KEK: momentum studies Data provided by Toho group: 2512 beam tracks D. Duchesneau April 27 th 2011 Track  x Track  y Base track positions.
Medium heavy Λ hyper nuclear spectroscopic experiment by the (e,e’K + ) reaction Graduate school of science, Tohoku University Toshiyuki Gogami for HES-HKS.
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
Lambda hypernuclear spectroscopy at JLab Hall-C Graduate School of Science, Tohoku University Toshiyuki Gogami for the HES-HKS collaboration 1.Introduction.
HKS Analysis Status Report HKS Analysis Status Report Liguang Tang (Hampton/JLAB) Hall C User Meeting, Jan. 15, 2011 HKS has data taken in 2005 (E01-011)
SuperNEMO Simulations Darren Price University of Manchester July, 2005.
25/07/2002G.Unal, ICHEP02 Amsterdam1 Final measurement of  ’/  by NA48 Direct CP violation in neutral kaon decays History of the  ’/  measurement by.
Analysis strategy of high multiplicity data Toshiyuki Gogami 24/Feb/2011.
Analysis memo (JLab E05-115) 30 May 2014 Graduate school of science, Tohoku University Toshiyuki Gogami.
Javier CastilloLHC Alignment Workshop - CERN - 05/09/ Alignment of the ALICE MUON Spectrometer Javier Castillo CEA/Saclay.
JLab hypernuclear collaboration meeting / JSPS Core to Core Seminar Study of elementary process in Hall-C p(γ*,eK + )Λ/Σ 0 9May2012 – 11May2012 Department.
Taikan Suehara, ECFA08, Warsaw, 2008/06/11 page 1 Tau-pair and SUSY analysis for ILD optimization in Jupiter/Marlin framework Taikan Suehara ICEPP, The.
S-2S meeting Toshiyuki Gogami 4Aug2014. Contents Missing mass resolution study J-PARC/KEK tour (7/29, 7/30) CAD drawing of water Cerenkov detector.
Energy Loss Toshiyuki Gogami 15Apr2013. Simulation Particles are generated at the center of target Randomly generation points are moved in the target.
HLAB MEETING ~ Status Report ~ Toshiyuki Gogami 14Jan2014.
E Analysis update Adjust of the Splitter-HKS Side Yuncheng Han May 09, 2012 Hampton University JLab hypernuclear collaboration meeting.
Hypernuclei Production Experiment E05115 at Jefferson Laboratory by the (e,e’K + ) Reaction Chunhua Chen March 31, 2012  Introduction  Experimental Setup.
HES-HKS & KaoS meeting Toshi Gogami. Contents Energy loss simulation by HES,HKS and POSI 1.POSI for beam energy loss – Harver foil is already implemented.
Some thoughts on the pointing measurement Nilanga Liyanage.
W Mass and Width at LEP2 Jeremy Nowell ALEPH / Imperial College London On behalf of the LEP collaborations.
Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.
HES-HKS analysis meeting Toshi Gogami 5Mar2014. Contents  Cross section & Λ binding energy 12 C(e,e’K + ) 12 Λ B 10 B(e,e’K + ) 10 Λ Be 7 Li(e,e’K +
HES-HKS and KaoS meeting 21Nov2013 Toshi Gogami. Contents Response function of hypernuclei.
JPS 2003 in Sendai Measurement of spectral function in the decay 1. Motivation ~ Muon Anomalous Magnetic Moment ~ 2. Event selection 3. mass.
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
Jan. 18, 2008 Hall C Meeting L. Yuan/Hampton U.. Outline HKS experimental goals HKS experimental setup Issues on spectrometer system calibration Calibration.
Various Rupak Mahapatra (for Angela, Joel, Mike & Jeff) Timing Cuts.
04/06/07I.Larin pi0 systematic error 1  0 error budget Completed items (review) Updated and new items (not reported yet) Items to be completed.
4/12/05 -Xiaojian Zhang, 1 UIUC paper review Introduction to Bc Event selection The blind analysis The final result The systematic error.
06/2006I.Larin PrimEx Collaboration meeting  0 analysis.
Absolute Polarization Measurement at RHIC in the Coulomb Nuclear Interference Region September 30, 2006 RHIC Spin Collaboration Meeting RIKEN, Wako, Japan.
HES-HKS & KaoS meeting 24/Feb/2014 Toshi Gogami. Contents 12 Λ B cross section Comparison with Motoba-san’s calculation Acceptance Linearity after matrix.
Energy Loss Graduate School of Science, Tohoku University Toshi Gogami 22/May/2013.
Paolo Massarotti Kaon meeting March 2007  ±  X    X  Time measurement use neutral vertex only in order to obtain a completely independent.
1 Kenematic Calibration of Hypernuclear Missing Mass by using Geant4 simulation Outline: 1, Data Generating 2, Kenematics Calibration a) E 0 &P Calibration.
HKS collaboration 2008/5/16 Wedding Party 2008/5/10.
HES-HKS & KaoS meeting. Contents Different distorted initial matrices Distorted matrix sample 6 (dist6) Distorted matrix sample 7 (dist7) Distorted matrix.
Study of the Differential Luminosity Spectrum Measurement using Bhabha Events in 350GeV WANG Sicheng 王 思丞 Supervisor: André Sailer.
DESY BT analysis - updates - S. Uozumi Dec-12 th 2011 ScECAL meeting.
Introduction of my work AYAKO HIEI (AYA) Hiroshima Univ 2008/5/30 me.
Biagio Di Micco  mass measurement Systematics on   mass measurement Biagio Di Micco.
Biagio Di Micco  mass measurement   mass measurement blessing of the final result Biagio Di Micco.
Statistical Significance & Its Systematic Uncertainties
Target Effect, Beam correction and T0 Adjustment
Muon momentum scale calibration with J/y peak
Search for Pentaquarks at
Search For Pentaquark Q+ At HERMES
Osaka University RCNP Toshinao Tsunemi
The First
p0 life time analysis: general method, updates and preliminary result
° status report analysis details: overview; “where we are”; plans: before finalizing result.. I.Larin 02/13/2009.
A New Measurement of |Vus| from KTeV
The Pentaquark Q+ Search
Problems with the Run4 Preliminary Phi->KK Analysis
Prospects for quarkonium studies at LHCb
NKS2 Meeting with Bydzovsky NKS2 Experiment / Analysis Status
Study of Top properties at LHC
° status report analysis details: overview; “where we are”; plans: before finalizing result.. I.Larin 02/13/2009.
Presentation transcript:

Systematic error and double Gaussian fitting Toshi Gogami 3Apr2014

Contents

Different distorted initial matrices Distorted matrix sample 6 (dist6) Distorted matrix sample 7 (dist7) Distorted matrix sample 8 (dist8)

Differential non-linearity (older sample) Missing mass [GeV/c 2 ]

Before and after the optimization (dist6)

Standard deviation due to matrices (dist6) σ = sqrt(σ mat +σ stat ) σ mat = sqrt(σ-σ stat )

Results for (dist8) (g.s. fitting mean )– M gen [keV] A σ mat [keV] B Lambda21.2 Sigma Λ He Λ Li Λ Be Λ B Λ Cr5.2

Results for (dist7) (g.s. fitting mean )– M gen [keV] A σ mat [keV] B Lambda6.8 Sigma Λ He Λ Li Λ Be Λ B Λ Cr27.6

Results for (dist6) (g.s. fitting mean )– M gen [keV] A σ mat [keV] B Lambda32.9 Sigma Λ He Λ Li Λ Be Λ B Λ Cr37.0

Summary 1 [Systematic errors] 5% of target thickness uncertainty  Λ, Σ 0 : < 50 keV  Hypernucleus : < 20 keV

Decomposition of 1 - and 2 - -B Λ [MeV] Counts Chunhua’s spectrum

Test conditions Common conditions for tests  N point = 100  Step = MeV  Mean1: – Step * i (i<N point )  Mean2: Step * i (i<N point ) Parameters Chunhua’s spectrum σ = (fixed) Han’s spectrum σ = (fixed) Toshi’s spectrum σ = (fixed)

|χ | distribution real data

|χ | distribution (Chunhua2009) Mean1 [MeV] Mean2 [MeV] σ = 231 keV (fixed) Mean1 [MeV] Mean2 [MeV] |χ |

|χ | distribution (Han2009) Mean1 [MeV] Mean2 [MeV] σ = 300 keV (fixed) Mean1 [MeV] Mean2 [MeV] |χ |

|χ | distribution (Toshi2009) Mean1 [MeV] Mean2 [MeV] σ = 220 keV (fixed) Mean1 [MeV] Mean2 [MeV] |χ |

SIMULATIO N

Test conditions (Simulation)  N point = 100  Step = MeV  Mean1: – Step * i (i<N point )  Mean2: Step * i (i<N point )

Generated dummy data -B Λ [MeV] [Counts/240 keV] SIMULATION

Fitting results (1) Mean1 [MeV] Mean2 [MeV] Mean1 [MeV] Mean2 [MeV] σ = 180 keV σ = 190 keV Assumed width for fitting SIMULATION

Fitting results (2) Mean1 [MeV] Mean2 [MeV] Mean1 [MeV] Mean2 [MeV] σ = 210 keV σ = 220 keV σ = 230 keV Assumed width for fitting SIMULATION

Fitting results (4) Mean1 [MeV] Mean2 [MeV] Mean1 [MeV] Mean2 [MeV] σ = 240 keV SIMULATION

Sample s Mean1 [MeV] Mean2 [MeV] [MeV]

Summary 2 [About 12 Λ B(1 -,2 - ) separation] What we can say from this study We could not reproduce paper values…. (E data could be reproduced though) (I would like to see Hampton’s side study) What we thought from this study In the case of simple Gaussian Difficult to find the answer with this method… In the real case (peaks are not simple Gaussian distributions) If this method works well after some analysis improvements, we need to confirm whether the method works or not for peaks which affected by energy straggling, production point displacement from matrix origin, detector resolutions, spectrometer acceptance, beam raster and so on.  Can be checked by blind analyses. Is there any good cut (selection) condition to find the answer ?  need further study.