2 December, 2015 New Conventional Fire Control Panel.

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

INTRUSION ALARM TECHNOLOGY
CL100D series DSP controlled Uninterruptible power supplies.
Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
ID to 8 Loop Intelligent Fire Alarm Panel
Integrated Technology!
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Discovery 1-4 Loop Analogue Addressable Control Panels
GS3055-I GSM Universal Wireless Alarm Communicator
1 Strictly confidential | Engineering| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.
Reliability Different worlds – same problem …one solution: Redundancy
 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
HARPER CHALICE GROUP LIMITED “PROTECTOR” PulseSecure ™ Fully monitored double pole High and Low voltage Perimeter security system”
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
VEGA CONTROL PANEL Technical
PYROCON12 De-Ice controller User Operation Presentation 2013.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Precept Conventional Control Panels
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Graphical Alarm Management System
ONYX Product Overview.
Alarmline Linear Heat Detection
Addressable Fire Alarms
1 Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights.
 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
RP-2000 Series Deluge & Agent Releasing Panels
WATER LEAK DETECTION SYSTEM
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
Jan’15 Kevin Thomas, Peter O’Connell, Peter Lewis, Steve Paskell, Martyn Walley Asbestos Issue Prevents Fire Safety Upgrade.
Fire Detection Presentation
An Introduction to the Windows-based PC Programming Tool Version 0.91
Linear Heat Detection.
GasGard® XL Monitor.
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
HP900 (ESP Protocol) Analogue Addressable Control Panels
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
KIDDE FIRE PROTECTION Vega Peer to Peer Networking.
Intelligent Detection Systems l integrity of system confirmed continuously l pre-alarm facility l high flexibility of system configuration l performance.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
CB200 Conventional Control Panels
3-Phase Submersible Motor Control
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Precept Marine Conventional Control Panels
CB200 e Cabinet Extinguishant Control Panels Designed for cabinet extinguishant systems 2 zone extinguishant co-incidence operation Selectable discharge.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
FireClass Addressable FC501 Part 2 - Panel Use. FC501 Engineering 3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
FLATPACK Rev.5 September 2002 Updated versions may be available.
Voice Evacuation an introduction. Please note: This presentation has been formatted to enable easy download and and is not recommended for large.
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
User Operation Presentation
Advisor Advanced Release FW120.
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
The FG series of explosive and toxic gas detectors and panels
Compliant Installation of Voice Alarm Systems
Technician Operation Presentation
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Presentation transcript:

2 December, 2015 New Conventional Fire Control Panel

2 Introduction History Objectives Features Benefits

3 History  System 8 ( ) Fixed format 2 and 4 zone Modular 8,16,24 to 64 Zone Extinguishing Release Module (ERM) version FOC approved - BS3116 part 4  Firebeta MKI ( ) Fixed Format 2 and 4 Zone Modular 8,12,16,20, to 120 Zones Designed to meet BS3116, BS5839 and UL864 ERM version

4 History Sirius ( present) Fixed format 2,4,8,16 and 32 Zone ERM version LPCB, HKFS approved to BS5839 part 4 Firebeta MKII ( present) Fixed format 2 and 4 Zone budget 2,4,8 and 12 zone Standard version Designed to comply with EN54 part 2 and 4 ECP variant

5 Objectives  New fully featured Conventional panel with approvals  Prepare for introduction of Construction Products Directive  Replace ageing Sirius products  Substitute for non approved Firebeta 2  Extend the range of ancillary product - PSU, Battery boxes etc  Introduce an RTC/Alarm counter variant for Export territories

6 Features  Range 2, 4 and 8 Zone Format  Fully Compliant with EN54 2 & 4 and BS 5839 part 1 (detector removal)  Integral zone device removal with short and open circuit monitoring - no AEOL.  Wide range of detectors supported, Apollo, Hochiki, Nittan, Gent and System Sensor

7 Features  2 x Alarm Circuits rated at 1 28Vdc  1 x Monitored Fire Output – Fire routing equipment  1 x VFCO Contact – Auxiliary Common fire output  1 x VFCO contact - Auxiliary Common fault output  Repeater Output - RS485 2 Core connection  Monitored Class Change Input  Auxiliary Supply Output - 28 volt rated 500mA fused

8 Features  2 x 16 LCD Display with intuitive on screen user prompts  2.5 amp Switch Mode PSU with intelligent battery monitoring  Earth fault monitoring disable facility  Buzzer disable facility  Pass code Access – EN  Access\Inhibit Key switch option

9 Option Card Features  Input \ Output Interface card 8 x Inputs – monitored for open & short circuit Class Change External Fault Input Silence Alarms Input Reset Input 4 x spare 8 x Outputs – VFCO relay contact Zone 1 to 4 Repeat Outputs – ERM trigger Manual Evacuate output Silence Alarms output (5 second pulse) Panel Reset output (5 second pulse) Alarm Repeat output (any fire condition)

10 Option Card Features  8 Way Sounder Output Card Outputs rated at 1 28 V d.c Individual switch 0 volt inputs activate circuits Common operation Zone by zone Pulse and timed options Remote PSU \ sounder booster unit option  8 Way VFCO Relay Output Card Relay contacts rated at 1 28 V d.c Operation - Zone of origin constant remaining zones silent

11 Option Card Features  8 Zone Repeater Panel Powered by main panel auxiliary output Option for external PSU Zone Repeat outputs – (open collector 0 volt outputs) Support for 7 Active and 7 Passive Maximum 500 metres 2 core + screen cable connection (Ext PSU) 4 core + screen cable connection (Aux O/P)

12 Features  One Man Walk Test  Zone Disable/Isolation  Alarm Management (T1 & T2)  Non-latching zone facility  Zone Co-incidence  Output Delays (T3 & T4)  Alarm Counter – 999 alarm conditions  RTC – Clock frozen at time of 1 st Zone Alarm Condition

13 Enclosure Features Polycarbonate Moulded Outer Door with metal back box  Space for 2 x 7Ah batteries  LCD Display 2 x 16 character  Zone legend text inserts  Logo insert  Dimensions - 350mm W x 280mm H x 100mm D

14 Enclosure

15 Enclosure

16 Enclosure

17 Enclosure

18 Enclosure

19 Product Range  2, 4 and 8 Zone variants  Input \ Output Interface card  8 Zone Repeater Panel  8 way Sounder card  8 way Auxiliary Relay card  Access inhibit key switch  Sounder Extension \ Booster Unit + PSU  2.5 amp PSU space for 2 x 7 AHr batteries  2.5 amp PSU space for 2 x 12 AHr batteries  Battery \ Interface Box housings

20 Typical Applications Developed for the professional installer Flexible in design, installation and operation Small cost conscious installations Applications include: Industrial units Schools Shop units Residential Premises Small Hotels

21 Benefits  Price/Performance  Accredited product - CPD  Simple to Install, Service & Maintain

22 The New Conventional Fire Control Panel