Albuquerque, NM Black band lives here! Team MembersRole Matt TurnerArchitectural & Foundations Engineer Matt MooreStructural Engineer Stu BurgessFluid.

Slides:



Advertisements
Similar presentations
Chp12- Footings.
Advertisements

Riverview Heights Darren K. Howard Structural Option Architectural Engineering Spring Thesis 2005 Advisor: Dr. Ali Memari.
Parts of typical slab formwork
Lecture 9 - Flexure June 20, 2003 CVEN 444.
EDT Foundation Plan Design1 Weekend Cabin Retreat Project Foundations Sacramento City College EDT 300.
Thermal Efficiency of Buildings Motaz H. Othman Mohammad S. Humaidi Supervised by: Dr. Salameh Abdul Fattah.
Apr 16 Discussions Hydraulic equilibrium Pressure and depth.
Architectural Drawing
Chp.12 Cont. – Examples to design Footings
Wall Form Design Example (Continued)
Preliminary Design Review
Foundation Systems.
CTC 422 Design of Steel Structures
BEARING OR CRUSHING Bearing Stresses (Compression Perpendicular to the Grain) Allowable stresses for compression perpendicular to the grain are available.
Preliminary Design Review Group Number Boise Idaho Tyler Banta Time Buckner Matthew Glynn Kelsey McConnaghy Justin Quackenbush.
Basic Hydraulics Irrigation.
PDR PRESENTATION Montgomery, AL. John MathewsArchitectural/Structural Derek SearsFoundation Michelle BaileyFluid Systems Clem PinBuilding Thermal Systems.
Slab Form Design.
It’s more than adding and subtracting..  Before bidding, the site should be examined for the following:  Distance from the office  Site conditions.
SPRINGVILLE CITY WATER TANK AND WELL PROJECT WILLIAM GARNER, JEREMY FOWLER, AUSTIN JASPER The city of Springville has been experiencing a period of rapid.
Commercial Foundations
Metals. Introduction u Metal is used in various places in the construction process including: –rebar = reinforcing steel in round shapes –flashing = thin.
Albuquerque, NM Black band lives here! Team MembersRole Matt TurnerArchitectural & Foundations Engineer Matt MooreStructural Engineer Stu BurgessFluid.
Thermal Building Design Wall Design and Heat Transfer Analysis.
HVAC523 Circulator Pumps.
FEASIBILITY OF COMPONENTS CLARA ECHAVARRIA & JONATHON LOCKE.
1 CTC 450 Review Water Quality Water Quality. 2 CTC 450 Water Distribution Systems Water Distribution Systems.
Umm Al-Qura University Department of Civil & Structural Engineering 1 Design of reinforced concrete II Design of one-way solid slabs Lecture (1)
Unit 2 Terms & Definitions.  Legal requirements designed to protect the public by providing guidelines for structural, electrical, plumbing, and mechanical.
Los Angeles, California
Calculations On completion of this unit the Learner should be able to demonstrate an understanding of: The formula used to calculate: Areas Volumes Ratios.
Preliminary Design Review Solar Thermal Water Heating System Team #5 San Diego, California Team #5 San Diego, California Ashley Tyler Tyler Borden Michael.
Balloon Frame North-American invention, 1833
Roof Terms Span –Distance across the building. Roof Terms Run –1/2 the distance across the building (1/2 span distance)
1 Building Types. 2 Building Use and Size Buildings are available in many types and sizes. Large, specialized buildings should be planned and built by.
Albuquerque, NM Black band lives here! Team MembersRole Matt TurnerArchitectural & Foundations Engineer Matt MooreStructural Engineer Stu BurgessFluid.
Heating Systems.
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Preliminary Design Presentation Group 5 Arlington, VA Kyle Desrosiers, Foundations Engineer Mohamed Mandeel, Structural Engineer Matthew Switzer, Fluid.
FORMS, SCAFFOLDING and STAGING
Two story home powered by solar energy Location: Tulsa, Oklahoma Team members: Andrew Blair, Karen Smith, Phil Eaton, Scott Melchionno, Tim Williams Preliminary.
Sustainable Roof Systems THE PLANETEERS In collaboration with LionForce Systems Dr. Diana Glawe Professor Kimberly Drennan.
1 Energy Efficient Housing. 2 Why construct energy efficient structures? Bottom Line !!! Money It may save up to 60% of the cost to heat/cool the structure.
Lecture 15 - Timber Wall Framing Example
Residential Construction
Building a Greenhouse ©2001 AgriTeach.com (103001ms) Greenhouse Materials Source: Fact Sheet University of Maryland Co-op Extension Service, David.
Competency: Design and Draw Foundation Plans
Ray Casper - Foundations Engineer John Scanlon - Structural Engineer Jimmy Mounnarat - Fluid System Engineer Igor Babushkin - Solar Thermal Engineer Preliminary.
Preliminary Design Review Tony Burnette Trevor Fitch Sheryl Gillow Sigitas Rimkus Simon Stam.
Spread Footing Design for Columns
House Construction.
AR362 - Structural Systems In Architecture IV Lecture : Foundations
PIPING DRAWINGS C H A P T E R T W E N T Y- O N E.
}السلام عليكم ورحمة الله وبركاته{
An-Najah National University Faculty Of Engineering
Plumbing system fundamental and design course
An-Najah National University
APPLICATIONS OF TECHNOLOGY
Objective 6.02 part 2: Recognize components of construction
WATER DEMAND (Chapter 24)
Chamber of Commerce & Industry
Studying Geothermal Heat Pump in Palestine
6.02 Recognize components of construction
Graduation Project – 2 Mini-Mall
MASS DENSITY AND VOLUME
DESIGN OF TRUSS ROOF Chapter 7
Components of Construction
Competency: Design and Draw Foundation Plans
Competency: Design and Draw Foundation Plans
© OnCourse Learning.
Presentation transcript:

Albuquerque, NM Black band lives here! Team MembersRole Matt TurnerArchitectural & Foundations Engineer Matt MooreStructural Engineer Stu BurgessFluid Systems Engineer Andy BirkelBuilding Thermal Systems Engineer Doug HeminkSolar Thermal Systems Engineer

Agenda Black band lives here! 1.Architectural 2.Foundations 3.Structural 4.Hydronic System 5.Building Thermal 6.Solar Thermal

Architectural First Floor Black band lives here!

Architectural Second Floor Black band lives here!

Architectural Basement? Initial research showed that few houses in New Mexico are built with basements, due to poor soil conditions Further research into the soil conditions, using has shown that almost half of the soil in the Albuquerque area would not be a limiting factor as far as basements are concerned Thus, further consideration shall have to be taken as far as the basement situation is concerned Additionally, both floors need windows added to them Black band lives here!

Foundation Compression due to House According to the International Residential Code, the live load varies from about 20 to about 60 pounds per square foot ≈ 40psf First Floor: 40 psf Second Floor: 30 psf Roof: psf ≈ 40psf All units then converted to metric, for consistency Produced the following table: Black band lives here!

Foundation Compression due to House Black band lives here! For concrete : 3,500 psi = kg/m 2 For cinder blocks : 2,200 psi = kg/ m 2

Foundation Force Caused by Soil Frost line Depth = 9’’ =.2286 m Minimum Footing Depth = 6’’ Below Frost line = 15’’ =.381 m If a basement is feasible, depth = 8’ = 2.44 m Had difficulty finding a specific soil density, instead just found a large range of densities Created the following table, displaying the force caused by the soil, as a function of soil depth and soil density Black band lives here!

Foundation Force caused by Soil Black band lives here!

Foundation Bending stress Caused By Soil Columns in yellow: minimum depth and “basement” depth From here moments and bending stresses caused by these forces can be determined Based on prior knowledge, it is already known that rebar will be necessary For now.2302 m is used as a thickness Black band lives here!

Foundation Bending Stress Caused By Soil Black band lives here!

Foundation What's Next From here I need to determine if any of these will give the desired factor of safety Assuming they won't, I'll need to determine amount of rebar required –Can also determine if the thickness can simply be increased A cost comparison should also take place Check to see if any pros/cons from one type significantly outweigh others Black band lives here!

Structural Engineer Support roof materials Support FPC system Factor of Safety = 4 to 6 Overhang Black band lives here! Roof Truss Design

Structural Engineer Possible Truss Designs Black band lives here! Fink TrussHowe Truss Double FanModified Queen

Structural Engineer Material Selection Black band lives here! Ponderosa Pine, Douglas FirSteel Relatively inexpensive Could require repair due to rotting Expensive Less maintenance required

Structural Engineer Fink Truss Analysis Black band lives here! R1R1 R2R2 Force from FPCs Span of m

Structural Engineer Fink Truss Analysis Black band lives here! For 5 FPCs : ~ 4500 N R1 = 3042 N R2 = 304 N 2” x 4” members2’’ x 6” membersPonderosa Pine σ c = 0.9 MPaσ c = 0.6 MPa FOS = 5.6FOS = 8.5

Hydronic System Analysis System Schematic Transports fluid between FPCs and Storage Tank Appropriate pump, valves and piping are to be chosen given an array of FPCs

Hydronic System Analysis Calculations With 5 FPCs Max head = ft Pipe Diameter= 1.5” Flow Rate = 20gpm With 10 FPCs Max head = ft Pipe Diameter= 2.0” Flow Rate = 40gpm

Hydronic System Analysis Pump Selection Cost with 5 FPCs $ Cost with 10 FPCs $ Both cases require similar head 10 FPCs requires a greater flow rate

Hydronic System Analysis Valve Selection Gate and Ball valves Minimal pressure drop Good for on/off applications Globe Valve Creates some pressure drop Good for regulating flow

Hydronic System Analysis Piping materials CPVC Cheap Self-insulated Lightweight Easy to work with Can become brittle and discolored when exposed to UV rays PVC Shares many of the upsides of CPVC Not suitable for hot water usage Copper Proven durability Fire resistant Requires skilled labor to install/repair Galvanized Steel High durability Expensive Very difficult to repair

Hydronic System Analysis Piping Costs Copper 1.5” Diameter $94.76 per 10 ft 2.0” Diameter $ per 10 ft CPVC 1.5” Diameter $42.45 per 10 ft 2.0” Diameter $58.76 per 10 ft

Building Thermal Systems Andy Birkel

Wall Construction Drywall Stud Insulation Plywood Stucco

Insulation Polyurethane Foam K value –0.023 W/mK Density –28 kg/m 3 Price –Roughly $7.43 per cubic ft Fiber Glass Batt K value –0.046 to Density –16 to 40 kg/m 3 Price –Average $7.37 per cubic ft

Wall Construction Drywall Length0.0095m K Value0.1600W/mK R Value0.0595m 2 K/W Stud Length0.0889m Width0.0381m O.C m K Value0.1000W/mK R Value0.8890m 2 K/W Poly Insulation Length0.0889m Width0.3683m K Value0.0240W/mK R Value3.7041m 2 K/W Plywood R Value0.1200m 2 K/W Stucco Length0.0222m K Value0.8100W/mK R Value0.0274m 2 K/W

Ceiling Construction Drywall Length0.0095m K Value0.1600W/mK R value0.0595m 2 K/W Stud Length0.2286m Width0.0381m O.C m K Value0.1000W/mK R value2.2860m 2 K/W Poly Insulation Length0.2286m Width0.5715m O.C m K Value0.0240W/mK R value9.525m 2 K/W

R Percentages Wall Materials Rvalue Between StudsAt Studs Drywall Stud Poly Insulation Plywood Stucco Total R Percentage of Wall Ceiling Materials Rvalue Between StudsAt Studs Drywall Stud Poly Insulation Plywood Total R Percentage of Wall

Total Values Total Wall R value Km 2 /W hrft 2 F/BTU Total Wall U W/m 2 K Total Wall UA W/K Total Ceiling R value Km 2 /W hrft 2 F/BTU Total Ceiling U W/m 2 K Total Ceiling UA W/K Total U Total UA Q °F°C In Out