Natura Water Machine B and D Series 3 – Dispense tower plumbing kit Kit number 038414-001 Kit includes components used for both Natura B and Natura D series.

Slides:



Advertisements
Similar presentations
Instructional Presentation
Advertisements

Selling Inoculants Module One – How are your Cows?
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Assembly Manual Mike Fortney 04/09/2004 CricketSat Receiver.
Stable Rise – Fixed Bracket / Stationary Top Installation and Set Up Guide Jaymil Ergo & Office Solutions 150 Dow Street, Tower 4, Manchester, NH
3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
Troubleshooting Guide. Table of Contents 2 Shower Filter 3 Leak Between Top Housing & Filter4 Leak Between Swivel Collar & Housing5 Leak at Top of Swivel.
Frame Assembly Produced by Ed Latimer, Team 476 Ken York, Team 476 Ron Markum, Team
Optical Manufacturing Solutions 1 Probe Assembly.
Installation. Indoor Unit Installation Typical Installation.
Click on this image to open the full PDF document.
Lucas Air Mass Meter Stripdown sequence and technical information.
1 STEPMILL 7000 PT ASSEMBLY INSTRUCTIONS PART NUMBER
Digital StarLab Set-Up, Operation, Maintenance, and Teacher Manual for the Digital StarLab are in the links below or on the training tab in the BlackBoard.
( 1 ) PROCEDURE FOR FLAT HEAT PRESS OPERATION PROCEDURE FOR MULTI FUNCTION HEAT PRESS MACHINE.
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
Strut Jack Operation The TeleCrib® Strut Jack is a removable 8,000 lb jack which fits over the strut body and gives the rescuer a controlled means for.
Engineer Training Inkjet Head Cleaning TJ8300 / TJ8500 Inkjet Head Cleaning.
Stable Rise –Pull and Swivel Top Installation and Set Up Guide Jaymil Ergo & Office Solutions 150 Dow Street, Tower 4, Manchester, NH
TrueSTEAM™ Humidification Systems Module 4: Advanced Installation.
HVACR312 - Refrigeration Metering Devices.
Pneumatic Arm Assembly Instructions
How to Construct a Robot Part 7: Wiring and Controller Installation Copyright © Texas Education Agency, All rights reserved. 1.
Using Surfcam to Produce a Numeric Control (NC) Program An Introduction to the CAD/CAM Process Instructions for 3 Axis Programming Using the D&M CNC Milling.
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
Assembly Manual Mike Fortney 04/02/2006 CricketSat Receiver.
3- Pipsqueak Piston and Cylinder. Work holding in the Lathe Collets have definite advantages over chucks in gripping work pieces in the lathe. They apply.
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Installation. Indoor Unit Installation Typical Installation.
Residential Wiring Facts
TP4-ENERSOL-TD/PV double function
Showing Demonstrations on the TV How to connect the camera to our TV set.
We Design It Replacing Hard Drives Tutorial Seven Easy Steps By: James Landon Carie Jackson Odetta Rodriguez Michelle R. Person Miceala Vega.
Title: Corvette C5 Column Lock Bypass Originator: John Neese Date: 30 Jan 2005 Revision: Sheet: 1 of 6 Column Lock Bypass.
Outcome 3 (part 2) Heat emitters and their components Unit 208: Central heating systems.
Installation. Indoor Unit Installation Typical Installation.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 8 System Tests.
1 FREE CLIMBER 4400 ASSEMBLY INSTRUCTIONS PART NUMBER
SUPPORT FUNCTION 1-1. SBS installation will be done same time by product specialist Loading & Unloading will be taken care for safe handling of.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Install Instructions August 1, 2008 Standard Knock-out plates need to be removed from the machine.
Fabrication of Fishtank Reservoir ENGR 121 living with the lab.
C - Series Installation Installation of C-Series signs is quick, easy and can be accomplished by anyone with just a little mechanical aptitude. Before.
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
XR621 Drive Hose Update Kit. Removal Turn off Battery dis Drain hydraulic tank Remove both rubber lines under chassis and discard. Remove and discard.
Electrical Circuits Elementary School Vanderbilt Student Volunteers for Science Training Presentation Fall 2012.
IOPtiMate™ OT-135P2 Technical Training – Part I System Description, Installation & Operation IOP (07)
Horizon Icemaker for Vision Satellite-fill Installation Installation Best Practices To navigate through the presentation, press the → and ← keys on your.
Plumbing Valves.
EBS-1 # COOLANT FLUID EXCHANGE QUICK REFERENCE ATTENTION: Using the Coolant Fluid Exchange requires the FILL and VAC Valves on the SERVICE.
GENERAL CAUTION TOOLS REQUIRED ASSEMBLY AND INSTALLATION
Brooks Expert Support Tool (BEST) Software
CAUTION GENERAL TOOLS REQUIRED ASSEMBLY AND INSTALLATION
Vanderbilt Student Volunteers for Science Training Presentation
ASSEMBLY/INSTALLATION INSTRUCTIONS ASSEMBLY AND INSTALLATION
MDX-R3 INSTALLATION PROCESS NON-ADJUSTABLE CONCRETE POOLS
MACH 112: Cutting Tools & Measurement
The ultimate chain lubrication system. LC – Low Cost Lubrication Kits
C Air Compressor Up-fit and Plumbing Guide For LDI B3
CAUTION GENERAL TOOLS REQUIRED ASSEMBLY AND INSTALLATION
SP Oil / Water Separator Installation Guide
Using Surfcam to Produce a Numeric Control (NC) Program
Vanderbilt Student Volunteers for Science Training Presentation
Vanderbilt Student Volunteers for Science Training Presentation
Reader Swap out Guide.
Replacing TrueAir Thermostat with Ecobee SI
Presentation transcript:

Natura Water Machine B and D Series 3 – Dispense tower plumbing kit Kit number Kit includes components used for both Natura B and Natura D series 3 machines to install the 2 or 3 tap dispensing tower. Below is a description of the components included in this kit. These instructions will reference the components as noted below. Read these instructions entirely before starting work. Supporting video can be found on the Natura web site for machine shutdown and startup (CO2 Purge). Caution – do not work on machine until all water, power and CO2 has been turned off and/or disconnected. Components included in kit: Snap Bushing Union Connector Reducing Union Flow Compensator 3 x 3.5’ Tubing 1P/N Step 1 Up-pack your Natura water machine; follow the installation instructions included with the machine. Note: these instructions may discuss connecting dispensing taps to your machine. If dispensing taps and tap shanks are included with your machine, please remove the tap shanks from the machine and set aside all taps and shanks as they will not be needed for this installation. Remove and set aside

2 P/N Step 2 Using the snap bushings included in our kit, snap them into the open tap shank holes located on the upper front of the machine. With the top removed, locate the 3 loose water supply tubes within the machine. These tubes will be color coded for easy identification: Green – CO2 water, Blue – Cold still water, White – Room temp still water Step 3 Using the reducing union fittings supplied in the kit, connect each water supply line to the 3 lengths of 3.5’ tubing, supplied in kit. Feed each line through the prospective bushing, be sure to mark each end of the new tube with the water type – you will need to know this when making the connection to the dispensing towers. Note: depending on the location and distance from the dispensing tower, it may be necessary to insulate the tubing that make the connection from the machine to the dispensing tower. Your installation kit is supplied with an adjustable Flow Compensator. Place this in a convenient location of the CO2 water supply line by cutting the line and connecting the flow compensator. Note the correct inlet and outlet ends of the compensator, and connect accordingly (see page 4 photo for reference). The flow compensator will be used to adjust the flow rate of the CO2 water outlet, to be detailed later in these instructions.

P/N Step 4 Locate and mount the dispensing tower. Using the union connectors in your kit, connect the supply line from the water machine to the supply leads on the dispensing tower. The recommended order from left to right is: CO2 Water – Cold Still Water – Room Temp Still Water Note: see page 5 for fitting connection instructions Step 5 Finish installation setup for the Natura Water machine, starting at Section 6.4 in instruction manual, supplied with machine. After all water connections have been inspected and all water supply lines have been secured and bundled, verify that water is flowing freely from each dispensing tap at the tower.

P/N Step 6 Adjust the water flow from the carbonation dispensing tap by adjusting the compensator adjustment screw so that the flow rate is close to 1 liter/14 seconds (turn clockwise to reduce flow). This is the setting for optimum carbonation level of the Natura water machine. Outlet Inlet Flow adjustment Screw (plastic) Compensator