NEEA DEI Study Data Analysis Plan October 28, 2005 RLW Analytics, Inc. Roger L. Wright, Chairman, and Principal Consultant.

Slides:



Advertisements
Similar presentations
Simplified VO M&V Protocols Approved May 4 th, Simplified VO M&V Protocol can be applied to distribution systems with Residential and Small Commercial.
Advertisements

DISPUTES & INVESTIGATIONS ECONOMICS FINANCIAL ADVISORY MANAGEMENT CONSULTING Early Lessons Learned from DOE-EPRI Framework Experience Melissa Chan MA DPU.
BG&E’s PeakRewards SM Demand Response Program Successful Approaches for Engaging Customers August 20, 2014.
Here we add more independent variables to the regression.
Authors: J.A. Hausman, M. Kinnucan, and D. McFadden Presented by: Jared Hayden.
DISPUTES & INVESTIGATIONS ECONOMICS FINANCIAL ADVISORY MANAGEMENT CONSULTING ©2014 Navigant Consulting, Inc. May 7, 2014 Navigant Reference: Impact.
ERCOT Analysis of 2005 Residential Annual Validation Using the Customer Survey Results ERCOT Load Profiling Presented to PWG - October 26, 2005.
DISTRIBUTION EFFICIENCY UPDATE 1. Distribution Efficiency – Quick Review Tier 1 study (19 circuits) completed in 2011 – Four circuits identified for pilot.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
Energy and Environmental Economics 1 Avoided Cost and E3 Calculator Workshops Energy and Environmental Economics, Inc. October 3, 2005.
1 Multiple Regression Interpretation. 2 Correlation, Causation Think about a light switch and the light that is on the electrical circuit. If you and.
What is Forecasting? A forecast is an estimate of what is likely to happen in the future. Forecasts are concerned with determining what the future will.
Multiple Regression [ Cross-Sectional Data ]
2005 LIEE Impact Evaluation Final Report January 23, 2007 Presentation to the Low Income Oversight Board West Hill Energy and Computing, Inc. with Ridge.
1 Econometric Load Forecasting Peak and Energy Forecast 06/14/2005 Econometric Load Forecasting Peak and Energy Forecast 06/14/2005.
2011 Long-Term Load Forecast Review ERCOT Calvin Opheim June 17, 2011.
On Comparing Classifiers: Pitfalls to Avoid and Recommended Approach Published by Steven L. Salzberg Presented by Prakash Tilwani MACS 598 April 25 th.
Relationships Among Variables
Distribution Measures: Voltage Reduction and Optimization Josh Rushton CVR/VO Subcommittee May 8, 2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
BPA Pre-Pilot, Monmouth  14 homes with installed DHP, single zone, single compressor.  11 Monmouth, 2 Moses Lake, 1 Tacoma  Savings.
Introduction to Linear Regression and Correlation Analysis
Slide Copyright © 2008 Pearson Education, Inc. Chapter 4 Descriptive Methods in Regression and Correlation.
Farmers Rural Electric Cooperative Corporation 2006 Load Forecast Prepared by: East Kentucky Power Cooperative, Inc. Forecasting and Market Analysis Department.
ERCOT 2003 UFE ANALYSIS By William Boswell & Carl Raish AEIC Load Research Conference July 13, 2005.
Capacity Impacts of Energy Efficiency What We Know and What We Don’t Know March 11, 2014.
Investment Analysis and Portfolio management Lecture: 24 Course Code: MBF702.
EDISON INTERNATIONAL® SM Internal Use Only Page 1 Circulating Block Heater Alfredo Gutierrez Cal TF Work Paper Presentation October 23, 2014.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
© 2007, Itron Inc. VELCO Long-Term Demand Forecast Kick-off Meeting June 7, 2010 Eric Fox.
Why Normal Matters AEIC Load Research Workshop Why Normal Matters By Tim Hennessy RLW Analytics, Inc. April 12, 2005.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Northwest Ductless Heat Pump Pilot Project Impact & Process Evaluation: Billing Analysis Ecotope, Inc. February.
Grayson Rural Electric Cooperative Corporation 2006 Load Forecast Prepared by: East Kentucky Power Cooperative, Inc. Forecasting and Market Analysis Department.
CHAPTER 1 LESSON 3 Math in Science.
Copyright © 2015 McGraw-Hill Education. All rights reserved. No reproduction or distribution without the prior written consent of McGraw-Hill Education.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
ERCOT Long-Term Demand and Energy Forecasting February 20, 2007 Bill Bojorquez.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits Regional Technical Forum August 12, 2014.
Math in Science.  Estimate  Accuracy  Precision  Significant Figures  Percent Error  Mean  Median  Mode  Range  Anomalous Data.
UFE 2003 Analysis June 1, UFE 2003 ANALYSIS Compiled by the Load Profiling Group ERCOT Energy Analysis & Aggregation June 1, 2005.
1 Distribution Efficiency Conservation Voltage Regulation (CVR) Jillianne Welker 4/21/2009.
Evaluation of the RTF Standard Protocol Fan and Cooling Savings from Commercial-Sector Heat Pump Units Rooftop Unit Working Group (RTUG) August 20, 2012.
April 15, 2003 UFE 2002 ANALYSIS. April 15, 2003 LOAD AND UFE – ERCOT PEAK 2002 This is a graphic depiction of load and UFE on the ERCOT Peak Day for.
Maintenance Workload Forecasting
Comparison of Pooled and Household-Level Usage Impact Analysis Jackie Berger Ferit Ucar IEPEC Conference – August 14, 2013.
2009 Impact Evaluation Concerns ESAP Workshop #1 October 17, 2011.
Chapter Seventeen. Figure 17.1 Relationship of Hypothesis Testing Related to Differences to the Previous Chapter and the Marketing Research Process Focus.
Distribution Efficiency Initiative: Calculator Review April 29, 2008 Regional Technical Forum.
2016 Long-Term Load Forecast
London - Loughborough Centre for doctoral research in energy demand Central House 14 Upper Woburn Place London, WC1H 0NN ANNUAL COLLOQUIUM.
T12 to HPT8 Change-outs Small/Rural request for development May 15, 2012.
STATISTICS AND OPTIMIZATION Dr. Asawer A. Alwasiti.
NASUCA Annual Meeting Austin, Texas November 10, 2015 Scott J. Rubin, Attorney + Consultant 333 Oak Lane + Bloomsburg, PA Office: (570)
Blue Grass Energy Cooperative Corporation 2006 Load Forecast Prepared by: East Kentucky Power Cooperative, Inc. Forecasting and Market Analysis Department.
Licking Valley Rural Electric Cooperative Corporation 2006 Load Forecast Prepared by : East Kentucky Power Cooperative, Inc. Forecasting and Market Analysis.
Utilities’ Update on Energy Savings Assistance Program Studies Ordered in D LIOB Meeting August 21, 2013 Sacramento, California.
Heat Pump Research Project Sponsored by the Heat Pump Working Group April 5, 2005.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
A Reliable but Simplified Method for Measuring the Savings from Advanced RTU Control Retrofits February 13, 2013 Presentation to: RTF Commercial Rooftop.
Variable Load on Power Stations
1 1 DISTRIBUTION EFFICIENCY INITIATIVE (DEI) Benefits on Both Sides of the Meter RTF MEETING February 5, 2008.
Metering and Measuring of Multi-Family Pool Pumps, Phase 1 March 10, 2016 Presented by Dan Mort & Sasha Baroiant ADM Associates, Inc.
Communicating Thermostats for Residential Time-of-Use Rates: They Do Make a Difference Presented at ACEEE Summer Study 2008.
Multi-Area Load Forecasting for System with Large Geographical Area S. Fan, K. Methaprayoon, W. J. Lee Industrial and Commercial Power Systems Technical.
2015 SDG&E PTR/SCTD Evaluation DRMEC Spring 2016 Load Impact Workshop George Jiang May 11 th, 2016 Customer Category Mean Active Participants Mean Reference.
A.Liudchik, V.Pakatashkin, S.Umreika, S.Barodka
12 Inferential Analysis.
12 Inferential Analysis.
Behavior Modification Report with Peak Reduction Component
Presentation transcript:

NEEA DEI Study Data Analysis Plan October 28, 2005 RLW Analytics, Inc. Roger L. Wright, Chairman, and Principal Consultant

Outline  Review our Clatskanie Substation Analysis  Highlight issues in future analysis of CVR substation pilots  Review HVR status  Discuss plans for analysis of HVR studies

Clatskanie Substation Analysis  We used the Clatskanie data to test our analysis methodology  We did not have information on the control status each day  Our first attempt was to regress kWh on voltage, Was not successful Problem traced to simultaneity of relationship between voltage and kW  Developed an algorithm to classify each day as a control or comparison day  This gave more plausible results – but the data are still preliminary

Initial Analysis Initial model: ln(kWh) = β 0 + β 1 ln(V ) where V = Voltage Equivalent to assuming a 1% drop in voltage yields a β 1 drop in kWh

The Observed Data

Initial Results We were hoping for positive betas!

Simultaneity of Voltage and kWh CVR effect: A drop in voltage is expected to yield a drop in kWh => + association. Load effect: An increase in kWh may cause the voltage to fall => - association A simple regression of kWh on voltage will reflect both effects and give an erroneous estimate of the CVR effect.

Remedy Let C = voltage control status, 0 = off or 1 = on Or C = quantitative level of control variable Record the control status day by day and hour by hour Study the effect of control status on both kWh and Voltage

Identifying the Control Status Control alternating off and on No clear control

Energy Print of Control Status The energy print of voltage revealed periods of good control, periods of poor control, and periods of missing data

Classification of Control Status  When the circuit was in control the step function was set to 118; otherwise 122  Used to validate the classification visually

Verification of Control Status Control Indicator Actual Voltage

Effect of Control on Voltage (mnv)

Effect of Control on kWh

β (Beta)= ΔkWh/ΔMNV For Phase A Feeder A - Divide the - 4% change in kWh by the - 3.2% change in MNV to obtain a Beta of 1.2 Across All Feeders and Phases - Divide the -.5% change in kWh by the - 3.1% change in MNV to obtain a Beta of.2

Estimated Beta by Feeder and Phase ErraticStable

Impact By Season  Summer  Smaller Loads  Negligible Cooling Loads  Loads are mostly Lights and Plugs  Winter  Heating load increases the overall load  Voltage control expected to have little or no effect on Electric Heating  Voltage Control, therefore should have  Modest Effect on Lights and Plugs  Smaller percentage effect in winter than summer

Figures 5 and 6  Summarize results for the Winter period  Overall Beta was only 0.1 Figures 7 and 8  Summarize results for the Summer period  Overall Beta was 0.3

Effect of Temperature  Fit a regression model of the form kWh = β 0 + β 1 C + β 2 T + ε kWh – Observed Energy Use of the feeder and phase in any hour of any Control period C – Indicator Variable that is equal to 1 if control was on in the hour, 0 otherwise T – Heating degrees If temperature < 65 0 then T = 65 0 – temperature T = 0 otherwise

Interpretation of the Coefficients β 0 = Least Squares Estimate of the expected kWh use in an hour with Control Off and with 0 Heating Degrees β 1 = Least Squares Estimate of the change in kWh use in an hour with Control On vs. Control Off β 2 = Least Squares Estimate of the change in kWh use in an hour per unit increase in heating degrees

Figures 9 and 10 Separate Winter and Summer regressions for each combination of feeder, and phase kWh_off = Estimated value of β 0 del_kWh = Estimated value of β 1 pct_kWh = del_kWh/kWh_off Finally, used change in voltage from Figures 5 and 7 to calculate the Beta as pct_kWh / pct_MNV

Winter results

Summer results

Figures 9 and 10  Support the hypothesis that voltage control has little or no effect on the heating component of the feeder load  Indicate that the average value of Beta is about 0.3 in both the winter and summer, once the heating load has been excluded  A 1% reduction in voltage appears to reduce the non-heating kWh load on the feeder by 0.3% on average across these feeders regardless of the season

Effect By Hour  Repeat this analysis for each hour of the day, from 1 to 24  For each combination of feeder, and phase, and each of the 24 hours, estimate a separate regression model of the form kWh = β 0 + β 1 C + β 2 T + ε  Combined Winter and Summer seasons into a single regression – as model captured effect of winter heating

Hourly results for Feeder A Phase A

Average hourly results

Figure 13  Provides graphs of average non-heating hourly load profile of all combinations of feeder and phase with and without voltage control  Voltage regulation has on average a very small effect  Effect is most consistent in the early morning hours when the load is smallest  During peak load effect is negligible

Lessons Learned from Clatskanie  The importance of clean voltage and kwh data and accurate information about the status of experimental control  Naive regression analysis can lead to biased findings  Beta seems to vary by end use and season  Careful regression analysis can ferret out effects (betas) by season or end use

Unresolved Question  How do the three phases of a feeder interact?  Is it best to analyze each phase separately or can they be combined?

HVR Studies - Objectives  Estimate the customer-side portion of the CVR effect  Help estimate how the CVR effect varies with end use  Help adapt the findings to various utiities and service areas

Targeted End Use Categories  Effects shown are from prior BPA end use study  We want to estimate the betas for these four end use categories

Approach  Install HVR devices in a stratified sample of homes to control the voltage (off or on) on a known schedule  Do an onsite audit of each sample home  Collect whole-house load data on hourly kWh and voltage  Analyze the resulting data much like substation data, but rolling in the end use information to estimate the end-use effects

Foundations for the HVR Analysis β = ∆ kWh / kWh Total House kWh = Sum of kWh by End Use, i.e. kWh = Σ kWh EU Similarly ∆ kWh = Σ ∆ kWh EU where ∆ kWh EU = β EU kWh EU So β = ∆ kWh / kWh = Σ β EU (kWh EU / kWh)

Approach 1. the overall β of the house 2. The end use energy share of the house kWh EU / kWh for each of the four end uses A) Analyze each home’s data to estimate B) Regress the overall β on the four end use energy shares to estimate the four end-use betas

Results will be developed by 1. Western region, all electric 2. Western region with gas service 3. Eastern region all electric 4. Eastern region with gas service Market segments: Measures of energy and demand: 1. Annual kWh 2. Seasonal kWh 3. Class peak kW

The Keys to Success  Reliable estimates of the whole-house betas for most of the sample homes.  Accurate estimates of the end use energy shares.  Substantial variation in the end use energy shares from home to home in the sample

Whole-house Betas  Our Clatskanie analysis indicates that we must have accurate information on HVR control status  Each house can be on a different control schedule, but we must know the schedule

End-use Energy Shares  We will integrate the information from the onsite audits and whole premise load data  Space heating, water heating, and AC have recognizable energy prints  Must rely on the audits for – Resistance space heating vs. heat pumps – Incandescent vs fluorescent lamps  Other plug loads will generally not be identifiable  Probably will have to settle for annual or seasonal end use shares but not hourly

Variation in End-use Shares from Home to Home  Expect variation due to availability of natural gas, vintage of home, climate zone and service area  Will need to combine all sample homes across utilities  Can hope to borrow strength using seasonal analysis

Concerns  Limited time and money for the analysis  Uncharted territory  CVR effects are relatively small and hard to detect  May depend on severity of weather during study period