Experience on Vibration Isolation System R. Sugahara KEK and Mika Masuzawa (1), Hiroshi Yamaoka (1), Yasuo Higashi (1) Yuichi Morita (2) and Satoru Yamashita.

Slides:



Advertisements
Similar presentations
Passive isolation: Pre-isolation for FF quads A. Gaddi, H. Gerwig, A. Hervé, N. Siegrist, F. Ramos.
Advertisements

Vibration issues for SuperKEKB M. Masuzawa, R. Sugahara and H. Yamaoka (KEK) Vibration issues for SuperKEKB (IWAA2010)
ILC Cryomodule Earthquake response simulation H. Hayano, H. Nakai, Y. Yamamoto LCWS13 AWG7-SCRF.
Development of a mover having one nanometer precision and 4mm moving range Y. Morita, S. Yamashita ICEPP, University of Tokyo Y. Higashi, M. Masuzawa,
Experience Report with the Alignment Diagnostic System Georg Gassner September 17 th 2010.
Nov ’01, page 1 Current Work on Hydraulics for LIGO 1 and Advanced LIGO Rich Abbott, Graham Allen, Daniel DeBra, Joe Giaime, Giles Hammond, Marcel Hammond,
StaFF: Motion Stabilization with Nano-Meter Precision Proposed experiment conducted within framework of StaFF (Stabilization of Final Focus for ILC). Funded.
Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center LCLS Undulator Physics.
H. MAINAUD DURAND on behalf of the CLIC active pre-alignement team with 3D views and data from Hubert Gerwig, Richard Rosing and Juha Kemppinen Pre-alignment.
19 Nov 08,ILC08Cherrill Spencer Rotating Coil System Description 1 Short description of the SLAC rotating coil system used to measure the CIEMAT-made prototype.
Introduction to seismic sensors (subject 3.2) Peter Novotny PACMAN meeting, CERN, 7 October 2014.
1 ATF2 project: Investigation on the honeycomb table vibrations Benoit BOLZON 33rd ATF2 meeting, 24th January 2007 Laboratories in Annecy working on Vibration.
Mechanical Vibrations
Vibration measurements on the final doublets and the Shintake Monitor Benoît BOLZON7th ATF2 project meeting, 16/12/08.
Yuji Otake, Akito Araya and Kazuo Hidano
Techniques to approach the requirements of CLIC stability K. Artoos, O. Capatina (speaker), M. Guinchard, C. Hauviller, F. Lackner, H. Schmickler, D. Schulte.
ALIGNMENT DESIGN AND STATUS OF TAIWAN PHOTON SOURCE WEI-YANG LAI October,
LCC Linear Collider Collaboratio ILC - CFS 12 November 2013 LCWS13 Tokyo University 1 Site-specific CF design from TDR LCWS13, 12 November 2013 Atsushi.
Review of Ground Motion Measurement Program of DESY in Various Sites R. Amirikas, A. Bertolini, W. Bialowons LHC tunnel, CERN HERA tunnel, DESY Ground.
Quad-to-quad correlated motion in FLASH Ramila Amirikas, Alessandro Bertolini DESY Hamburg XFEL beam dynamics meeting, February 25 st 2008.
David Urner, Oxford University, RHUL – June StaFF Stabilization of Final Focus Motion Stabilization with Nano-Meter Precision David Urner Paul Coe.
Supports and Movers for ATF2 Magnets R. Sugahara KEK France and Japan Collaboration Meeting Feb , 2006.
CERN, BE-ABP (Accelerators and Beam Physics group) Jürgen Pfingstner Orbit feedback design for the CLIC ML and BDS Orbit feedback design for the CLIC ML.
CLIC MDI stabilization update A.Jeremie G.Balik, B.Bolzon, L.Brunetti, G.Deleglise A.Badel, B.Caron, R.Lebreton, J.Lottin Together with colleagues from.
STABILIZATION ACHIEVEMENTS AND PLANS FOR TDR PHASE CLIC MAIN BEAM QUADRUPOLE MECHANICAL STABILIZATION K. Artoos, C. Collette, P. Fernandez Carmona, M.
CLIC MDI Working Group Vibration attenuation via passive pre- isolation of the FF quads A. Gaddi, H. Gerwig, A. Hervé, N. Siegrist, F. Ramos.
November 17, st XFEL / ILC Meeting 1 ILC GLOBAL Design Effort The Current ILC Twin Tunnel Design Wilhelm Bialowons and Nicholas Walker · MPY.
1 H. Yamaoka R. Sugahara M. Masuzawa IR stability at SuperKEKB June 14, ‘10 H. Yamaoka.
Performance Test of Laser Trackers of FARO Ryuhei Sugahara, Mika Masuzawa and Yasunobu Ohsawa KEK, High Energy Accelerator Research Organization Oho, Tsukuba,
July 5, 2007 C. HAUVILLER CLIC stabilization Beam line and final focus.
The beam-based alignment and feedback systems, essential operations of the future colliders, use high resolution Beam Position Monitors (BPM). In the framework.
NLC - The Next Linear Collider Project SLAC tunnel motion and analysis Andrei Seryi SLAC Originally given at The 22nd Advanced ICFA Beam Dynamics Workshop.
J T Volk Fermilab April 2008 Ground Motion Studies at Fermi National Accelerator Laboratory James T Volk Applications Physicist II Vladimir Shiltsev, Shavkat.
1 SiD Push-pull Plans Marco Oriunno, SLAC International Workshop on Linear Colliders 2010 Geneva, October 2010 M.Oriunno, IWLC10 – Geneva, Oct.2010.
Production and Installation Policy of IP-BPM ATF2 Project Meeting, 2006/12/18 Y. Honda, Y. Inoue, T. Hino, T. Nakamura.
Hard or Soft ? C. Collette, K. Artoos, S. Janssens, P. Fernandez-Carmona, A. Kuzmin, M. Guinchard, A. Slaathaug, C. Hauviller The research leading to these.
ATF2 Magnets etc. 1. Magnets 2. Power supplies 3. Magnetic field measurement 4. Movers and supports R. Sugahara May 30, 2005.
NLC - The Next Linear Collider Project Mike Woods May 1999 Vibrations and the NLC IR Welcome to the NanoWorld !
How high frequency we care if we need the stabilization of 1nm level?
1 ATF2 Project Meeting December 2006 Ground Stabilisation with the CERN STACIS 2000 Stable Active Control Isolation System LAViSta Laboratories in.
Main beam Quad Stabilisation: Status of the stabilisation test program at CERN CLIC-stabilization day S. Janssens Contribution to slides by:
1/13 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 9, 2006) Mount.
Passive isolation: Pre-isolation for FF quads A. Gaddi, H. Gerwig, A. Hervé, N. Siegrist, F. Ramos.
Superconducting final doublet Support A.Jeremie. SC magnet steps Motivation: have an active stabilisation as planned in ILC and CLIC => need to evaluate.
FD Movers and Alignment Methods Superconducting Magnet Division, BNL IRENG07 Workshop: September 19, 2007.
Taikan SUEHARA et al., LCWS2007 & DESY, 2007/06/01 R&D Status of ATF2 IP Beam Size Monitor (Shintake Monitor) Taikan SUEHARA, H.Yoda, M.Oroku,
1 KEK Hiroshi Yamaoka Vibration analysis of the ILD QD0-support system Oct, 2 nd '09 KEK H. Yamaoka - Results of Vibration analysis - Coherency measurement.
ATF2: final doublet support Andrea JEREMIE B.Bolzon, N.Geffroy, G.Gaillard, J.P.Baud, F.Peltier With constant interaction with colleagues from KEK, SLAC.
NLC - The Next Linear Collider Project Keeping Nanometer Beams Colliding Vibration Stabilization of the Final Doublet Tom Himel SLAC NLC MAC review October.
Chigasaki Research Institute J-Power / Electric Power Development Co.,Ltd. Ground Motion Measurement in Accelerator Test Facility at KEK ・ KEK ・ ICEPP.
Test plan for CLIC MB linac quad LAPP option A.Jeremie.
QD0 stabilisation in CLIC CDR A.Jeremie with LAViSta team.
SUPERKEKB MAIN RING TUNNEL MOTION M. Masuzawa, T. Adachi, H. Iinuma, T. Kawamoto and Y. Ohsawa, KEK Tsukuba, Japan
1 Investigation of vibration properties of the KEKB tunnel after the Great East Japan Earthquake Contents Situations after the earthquake Geological survey.
Accuracy of the orbit measurement by KEKB BPM system for the study of ILC damping ring H. Fukuma (KEK) Requirement for the accuracy of BPM data.
HLS Installation at KEKB Main Ring after the Great East Japan Earthquake Takashi Kawamoto, Mika Masuzawa, Ryuhei Sugahara High Energy Accelerator Research.
Alignment and stability session
Vibration issues at Linear Colliders:
Re-entrant BPM R&D for ILC Main Linac
CLIC magnets precise positioning
EuroTeV WP7 activities in DESY
Laboratories in Annecy working on Vibration Stabilization
A Study of blasting vibration influence to ILC project using high sensitivity seismograph networks (Hi-net) in granite site Ichiro Sekine A), Ryou Wakatake.
Status of the TESLA Magnet Package and Vibrations at TTF
Background With new accelerators delivering beams always smaller and more energetic, requirements for very precise beam alignment become more and more.
The Superattenuator upgrades and the SAFE Project
IP configuration session
Floor Movement Measurement at ATF Ring
Fixed Support Design & Testing
Seismometer Development for the 1TeV Linear Collider
Presentation transcript:

Experience on Vibration Isolation System R. Sugahara KEK and Mika Masuzawa (1), Hiroshi Yamaoka (1), Yasuo Higashi (1) Yuichi Morita (2) and Satoru Yamashita (2), (1) High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki (2) International Center for Elementary Particle Physics (ICEPP), Tokyo University ILC S&A Group Meeting at DESY 29 May, 2007

1. Introduction (ground motion at ILC site) 2. Vibration isolation table commercially available 3. Vibration isolation table developed at KEK 4. Summary

Beam size at ILC-IP (nominal value) is 6 nm in vertical direction and 640 nm in horizontal direction --> Stability of final quadrupole magnets should be 1nm or higher in vertical direction Amplitude of ground motion is bigger than 1nm in low frequency region --> What is the frequency region we should care? 1. Introduction

(1) KEK site..... soft ground - Diluvium in Kanto plane (alternative layers of sand, gravels and clay) - Measured on the ground surface and in the KEKB accelerator tunnel (10m deep underground) - There is a main public road about 1km far from the measurement place. (2) SPring-8 (8 GeV synchrotron light source lab.)..... constructed on hard bedrock - Kamigori metagabbro rock area - Measured on the bedrock near to the accelerator ring 1-1. Ground motion in various grounds (See Paper [1] in detail)

(3) Mitsuse road tunnel in Sefri area..... granite rock area - Penetrating Sefuri mountain chain (granite rock) - Located in border between Fukuoka and Saga prefectures - Measured at a point about 10m far from near edge of the road on the concrete floor in a shelter area, which is located about 800m inner from the entrance of the tunnel. (4) Esashi area..... granite rock area - Measured in Mizusawa Earth Tide Observatory About 150m long horizontal tunnel constructed in Abara mountain (granite rock) - Measuremed on a granite base plate fixed on the bedrock.

Fig.1 PSD (Power Spectrum Density) measured in 5 areas. Fig.2 Integrated PSD measured in 5 areas. (a)(b) (c)(d) 2. Ground Motion in Various Grounds Daytime Night-time

( From TESLA TDR ) PSD Integrated PSD HERA, KEK SLAC CERN, ILC site candidates in Japan Main Linac BDS area Site GM C is OK C/3 or 3*B Mechanical noise < 30nm < 10nm

- An active vibration isolation system was made at KEK in order to have some experience on vibration isolation technique. One of essential techniques to future linear colliders. - Principle of control is almost the same to those commercially sold 1200x1200 mm 2 and 497mm high Weight is 1300 kg. It can bear 500kg. 2. Vibration isolation table-I (See Paper [2] in detail)

- A pair of horizontal and vertical actuators are installed to each of four pillars as shown by violet arrows. Two actuators for X-movement, two for Y and four for Z. - Those actuators can control not only parallel movements but also rotations around X, Y and Z axis. - Those actuators are pneumatic control valve type with 0.3 MPa air.

Six acceleration sensors to table (shown by red arrows) One for X, two for Y and three for Z Six displacement sensors to measure relative displacement between table and base (shown by black arrows) One for X, two for Y and three for Z Three acceleration sensors to base Each for X, Y and Z Acceleration sensors have resolution 0.1 mGal and frequency range Hz Displacement sensors have resolution 5  m. Sensors:

Vibration of floor and table (a) Floor (b) Without air spring (c) With air spring (passive mode) (d) Active mode X Y Z X Y Z X Y Z X Y Z

(a) Without air spring (b) With air spring (passive mode) (c) Active mode X Y Z X Y Z X Y Z PSD ratio of vibration of table to that of floor

As the feedback is based on the signal from seismometers, slow speed displacement cannot be eliminated. The system itself sometimes causes drift. This system is very sensitive to sound noise. --> How about the feedback system based on the signal from displacement sensors having speed about 10 Hz and the resolution 1nm? Problems

CAM Mover Stage PIEZO Mover Stage 3. Vibration isolation table-II (See Paper [3] in detail) X Y V Beam direction

Specification Mass350 kg MaterialSUS303 Load limit700 kg Two stage mover to achieve wide moving range and extra-high precision CAM mover stage -3 CAM shafts with motors -Moving direction3 directions (X, V and  y) -Moving range4.5mm -Precision0.1  m Piezo mover stage -6 piezoelectric transducers 3 for vertical and 3 for horizontal direction --> Able to adjust X, Y, V,  x,  y and  v -Moving range0.4  m -Resolution1 nm

Connecting arm 3 motors Shafts with offsets motor X V Top table moves in X, V and  y directions Rotation axis Center of the CAM shaft Cam mover

stoppers Cam mover stage lower the natural frequency to 45Hz Stoppers were installed to make it more rigid Problem!

Natural frequency with/without of stoppers Vertical directionX direction Vertical direction Red: on the table Blue: on the floor With stoppers Without stoppers 30, 50, 60Hz 65Hz 50, 60Hz over 100Hz Cam mover stage became more rigid!

3 piezos for vertical motion and 3 piezos for horizontal motion Table moves in X, Y, V,  x,  y and  v directions Cross sectional view at W-W spring structure Piezoelectric mover Enlarged view W W

12nm Resolution 1 or 2nm can be expected Time (sec) Movement of table (  m) Response speed of piezoelectric transducer is 56 nm/msec Piezo resolution and response speed

Summary Stabilization of 1nm level is required for final quadrupole magnets at ILC-IP Amplitude of GM exceeds 1nm in the frequency region less than about 10Hz at the ILC candidate sites except for DESY site Vibration isolation table (VIT) was fabricated and its performance was tested In this test following problems were found: (1) VIT cannot do anythig for low frequency movement, because VIT utilizes seismometers in its feedback or feed forward system. (2) VIT itself drifts sometimes (3) VIT is sensitive to sound. System has to be covered with acoustic material. Instead of VIT, high speed and high resolution mover was developed to damp GM in the frequency region lower than 10Hz Resolution of 1nm level and speed of 1kHz can be expected. More study is going on.

[1] "Ground Motion Measurement and Vibration Suppression at KEK", Ryuhei Sugahara et al. KEK-PREPRINT , Nov pp; Contributed to the Workshop on Ambient Ground Motion and Civil Engineering for Low Electron Storage Ring, NSRRC, Hsinchu, Taiwan, July 21-22, [2] "PERFORMANCE OF AN ACTIVE VIBRATION ISOLATION SYSTEM", R. Sugahara, M. Masuzawa, H. Yamaoka, 8th International Workshop on Accelerator Alignment, CERN, Geneva, Switzerland, October 4-7, 2004; KEK-PREPRINT , Nov pp. [3] "Development of a mover having one nanometer precision and 4mm moving range" Y. Morita, S. Yamashita (Tokyo U., ICEPP), Y. Higashi, M. Masuzawa, R. Sugahara, H. Yamaoka (KEK, Tsukuba), KEK-PREPRINT , Nov 2006, 11pp; Proceedings of 9th International Workshop on Accelerator Alignment (IWAA 06), California, U.S.A Sep 2006, pp TH003. References

>>

Instruments VSE355G2 of Tokyo Sokushin Co., Ltd. Velocity sensor Used in KEK and SPring-8 areas f-range Hz Output 2.5V/kine STS-2 of Streckeisen Velocity sensor Used in Sefuri and Esashi areas f-range Hz Output 15V/kine * kine = cm/sec

(a) Time series plot for floor (b) Time series plot for table in passive mode with G# sounds (f=415.3Hz) (c) PSD for vibration of table X Y Z X Y Z X Y Z

Sampling rate is 2.54kHz For 10 seconds Standard deviation is 2.4nm A capacitive sensor is used to examine the property of the piezoelectric transducers Capacitive sensor Noise of the capacitive sensor