Sample tests for stain problem at KEK LCWA2009 at Albuquerque 01 Oct. 2009 T. Saeki 1.

Slides:



Advertisements
Similar presentations
New Optical Inspection Results at JLab An in-depth update since Chicago meeting ILC08 (Highlights reported in US Regional Talk by Mark Champion) Rong-Li.
Advertisements

E. KAKO (KEK) 2010' Sept. 10 KEK Global Design Effort 1 Operational Results from STF-VTS and Cryomodule Tests at KEK Eiji Kako (KEK, Japan)
T. Saeki (KEK) 15 May 2014 AWLC2014 at FNAL
Superconducting rf test facility STF Mechanical grinding development Ken Watanabe ( KEK ) ILWS08 in Chicago 17-Nov-08.
KEK cavity status, March 2011 H. Hayano, ALCPG11, WG3, Eugene.
Stain appeared after EP acid renewal Field emission at low gradient happened on MHI-06, MHI-07, in VT. Kyoto-camera found brown stain trace in beam pipes,
Status of Nb sample study TILC09 Main Linac S0 session 18 April 2009 T. Saeki on behalf of SRF surface analysis group at KEK.
Recent Surface Studies in KEK-STF
Series Tests of High Gradient Single- cell Superconducting Cavity for the Establishment of KEK Recipe T. Saeki (1), F. Furuta (1), K. Saito (1), M. Ge.
Cavity package T.Saeki BCD meeting 20 Dec Cavity shape BCD: TESLA shape Pros: small wakefield, HOM thoroughly investigated single-cell: 43 MV/m.
ILC PM Meeting S0 Webex Global Design Effort 1 S0/S1 Next Steps Lutz Lilje GDE.
Surface study at KEK 1) sponge cleaning 2) special single-cell cavity with de-toutchable Nb-samples T. Saeki on behalf of Jlab-FNAL-KEK S0 study collaboration.
CEA DSM Irfu May 28th A RD 05: SURFACE PREPARATION STUDIES FOR SUPERCONDUCTIVE CAVITIES F. Eozénou, T. Saeki - F. Eozenou / T. Saeki - A_RD_05.
ILC08 Chicago Global Design Effort 1 Discussion of Optical Inspection and Temperature mapping Results Several new inspection and mapping systems.
EP parameter comparison between JLab and KEK 28 Mar ILCW2010 at Beijing, GDE/Main Linac session T. Saeki.
Jim Kerby, Fermilab for Rongli Geng and the S0 Cavity Team 23 May 2010 Current Status of SCRF Cavity Development SCRF Cavity Technology and Industrialization.
Cavity status; recent KEK activities : Hayano (1) STF CM-1 cavities are; MHI-014: 3-rd VT:36MV/m (finished) MHI-015: 3-rd VT: > 18.4MV/m.
E. KAKO (KEK) 2009' Dec. 22 S1-G Webex meeting Global Design Effort 1 Final Results of KEK Cavities for S1-Global Eiji Kako (KEK, Japan)
STF EP, VT commissioning by FNAL AES001 H. Hayano, KEK
Superconducting rf test facility STF 1 Optical Inspection update at KEK Ken Watanabe ( KEK ) ILWS08 in Chicago 17-Nov-08.
Field emission issue and strategy to improve H. Hayano.
9-cell cavity coordination CM Ginsburg 8 Mar
Experimental Comparison at KEK of High Gradient Performance of Different Single Cell Superconducting Cavity Designs. F. Furuta, K. Saito, T. Saeki, H.
R.L. Geng, KEK September 9, 2010 Global Design Effort 1 Near Term ILC Gradient R&D R&D Specification and Standardization Gradient Gradient Yield/Scatter.
Parallel session summary ML/SCRF L. Lilje, H. Hayano, N. Ohuchi, S. Fukuda, C. Adolphsen (with help of Chris Nantista) TILC09,
Achievement of 41 MV/m Gradient by AES8 Rong-Li Geng Jefferson Lab ALCPG09, October 1, 2009.
Global Design Effort 1 S0 Status High-Gradient cavities Lutz Lilje DESY supplement by H. Hayano 04Sep2008 EC
TTC Meeting, Frascati, 5-7 December Summary of EP discussions at Oct SMTF meeting at FNAL T. Tajima (LANL), C. Boffo (FNAL)
Fermilab 2 Dec 2009CM Ginsburg Global Cavity Database Report C.M. Ginsburg (Fermilab) On behalf of the database group (as part of S0 effort):
ILC Cavity Gradient R&D Plan Proposal for Release 5 Rongli Geng for ILC Cavity Group 2jun2010 ILC SCRF WebEx Meeting 6/2/20101ILC SCRF WebEx Meeting.
CRAB for HL-LHC KEK activity 2010DEC Yoshiyuki MORITA.
Lab #5. Review for Practical #1 Colony morphology (pg. 19)
Superconducting rf test facility LCWS 2010 in Beijing, 28 Mar 2010, Ken Watanabe Replica-method and local grinding repair K. Watanabe (KEK) LCWS 2010 in.
(1)[12~13/Dec/2009] Optical inspection (2)[14/Dec] frequency & field flatness measurement (3)[10/Mar/2010] pre-EP (5μm) (4)[11/Mar] EP1 (100μm) (5)[11/Mar]
E. KAKO (KEK) 2009' Oct. 26 ILC KEK Global Design Effort 1 Cavity Preparation for S1-Global Eiji Kako (KEK, Japan)
HiGrade-Kickoff DESY Global Design Effort 1 ILC-HiGrade WP6 High-Gradient cavities Lutz Lilje DESY.
KEK-STF Vertical Test and Diagnostics Brief History & Future Plan Vertical Test Facility Cavity Diagnostic System Example of MHI#7 Cavity Summary of T-mapping.
Current study status of high gradient at KEK Fumio Furuta KEK SCRF meeting Fermilab. Apr
Cavity status; recent KEK activities MHI-06, MHI-7, MHI-8 were vertical tested on June, July.  EP acid (1000l) was re-newed on May 15. These cavity was.
Recent Results of Vertical Test for S1-Global Project at KEK-STF Y. Yamamoto, H. Hayano, E. Kako, S. Noguchi, H. Sakai, M. Satoh, T. Shishido, K. Umemori,
Explosive Events during V.T. in KEK ECFA (2013/5/30) 1.
Summary of Results and Development of Online Monitor for T-mapping/X-ray-mapping in KEK-STF Y. Yamamoto, H. Hayano, E. Kako, S. Noguchi, M. Satoh, T. Shishido,
Standard EP recipe at KEK T. Saeki KEK Hot topics session SRF – 29 July 2011, Chicago.
Quality control of EP in KEK-STF TTC meeting April 21 st 2010 FNAL Motoaki SAWABE.
Update on S0 Work in the Americas Region Camille Ginsburg (FNAL) 2 June 2009 Slides/Info from: Zack Conway (Cornell) Rongli Geng (JLab) Genfa Wu, Dmitri.
Plasma cleaning Laser re-melting technique at FANL M. Ge, G. Wu, J. Ruan, J. Ozelis, T. Nicol, D. Sergatskov, D. Hicks, L. Cooley Fermi National Accelerator.
Summary of STF-EP facility at KEK.
Cornell Updates Commissioning of T-map for ILC single cell starts.
Vertical Electro-Polishing activities at CEA Saclay
Motivation Vertical Electro-Polishing for high gradient cavity R&D.
ILC10 Beijing Global Design Effort
Electropolishing of Dressed ILC 9-cell Cavity
Condition of electron beam welding toward a high gradient application
Inspection of STF Baseline cavity #5 and #6
Vertical Electropolishing at Marui & KEK
Surface Analysis of the Quench Area Sample of Cavity Z111
S0 Status report from KEK
Effort Torwards Improving Large Scale Production for SC Cavities
A COMMON R&D ON THE HIGH GRADIENT Nb CAVITIES
R&D Activity for Field Emission and Vertical EP
Jiyuan Zhai ( IHEP ) TTC Meeting, JLAB, 6 Nov 2012
Y. Yamamoto, H. Hayano, E. Kako, S. Noguchi, M. Sato, T. Shishido, K
Quality control study with single-cell cavities
Vertical Test System and T-mapping/X-ray-mapping at KEK-STF
WG3: Main Linac SCRF(cavity,cryomodule)
Cornell Results 20 V 60 V Changing the Growth of Oxide (By Anodizing) Has Small Effects 20 V.
FOR SUPERCONDUCTIVE CAVITIES
TTC Meeting, 28 February - 2 March, 2011, Milan
Cavity Degradation Experience at S1-Global
Cavity & Cavity Integration; recent KEK activities
Presentation transcript:

Sample tests for stain problem at KEK LCWA2009 at Albuquerque 01 Oct T. Saeki 1

MHI#6 1-cell equator, t = 306 deg. Downstream : Outside weld area MHI#6 #9-BP, t = 241 deg. -1 MHI#6 #9-BP, t = 241 deg. -2 We replaced the EP acid of EP-tank at STF/KEK recently. After the replacement, cavity performances (MHI#6, MHI#7, MHI#8) become very bad (Eacc<20 MV/m) limited by heavy field emissions. We observed brown spots and traces inside the 9-cell cavities (MHI#6, MHI#7, MHI#8); Examples: (red indicates bad) MHI#06 : spot or traces on BP-#1, cell#1, cell#2, cell#3, cell#4, cell#8, cell#9, #9-BP MHI#07 : BP-#1, cell#1, cell#2, cell#3, cell#4, cell#5, cell#6, cell#7, cell#8, cell#9, cell#9-BP Kyoto-camera pictures using new LED illumination Introduction: Stain problem at STF/KEK For more details about the vertical test results of these cavities, see the presentation ”KEK cavity preparation for S1G” on 30th Sept. by E. Kako (KEK). 2

Scraping the bronw spot by scraper A brown spot was found inside the beam-pipe of old MHI#0 9-cell cavity after the EP. An old MHI#0 9-cell cavity was EP’ed. Scraped the brown spot by scraper. 3

Sample was set on Si wafer by silver paste. 0.5mm Sample preparation Si wafer Scraped Nb sample Reference silver paste 4

O FC Nb Si Nb O C Nb, O Nb-MHIcavity-contamination - as-received - F, S, Al, Ag < detection limit Nb11at% O48at% C27at% Si14at% (substrate) XPS analysis of scraped sample from old MHI 9-cell cavity Si wafer Only Nb, O, C were found on the scraped sample, assuming Si is from Si wafer. 5

Draining process of EP acid Drain EP acid for 15 min.Horizontal for 5 min. Drain EP acid for 10 min. Then UPW rinse starts. We are taking 30 min. to drain EP acid. This might be a reason for stain? 6

Labo-EP of samples at Nomura Labo-EP (20 um) with new EP acid ([Nb] = 0 ~ 0.4 g/L) at Nomura 11 Aug Exposing the samples to the air for 70 min. w/o Pure-Water (P.W.) rinse. No stain appeared. Light P.W. rinse for a few 10’s seconds. Stains appeared within a minute after exposing the samples to the air. 7

Exposing samples to the air after P.W. rinse Stains appeared within a minute after exposing the samples to the air. The stains appeared in the area where P.W. dried. (EP acid of [Nb] = 0.4 g/L) stains P.W. remaining 8

Modification of first U.P.W. rinse process Drain EP acid for 15 min.Horizontal for 5 min. Drain EP acid for 10 min. Then UPW rinse starts. First U.P.W. rinse duration after EP-acid-draining at STF/KEK was extended. The first U.P.W. rinse was extended with overflow for a longer time. Original sequence: [pouring U.P.W. for 7 min. + draining for 5 min. ] x 5 Modified sequence: [pouring U.P.W. for 60 min. + draining for 10 min.] + [pouring U.P.W. for 20 min. + draining for 7 min. ] x 3. MHI#9 (9-cell cavity) was processed with this modified sequence and reached Eacc = 27 MV/m at Q0 = 9x10^9 (quench), even with some field emission. More details about the results, see ”KEK cavity preparation for S1G” on 30th Sept. by E. Kako (KEK). 9

Still problem in the draining process of EP acid at STF/KEK PouringDraining Draining water conductivity vs time Cond. of U.P.W. Time to fill a 9-cell cavity ~ 3 min. Water dump Overflow Water from cathode Heavy acid is remaining at the bottom Slide by Ken WATANABE Still some stains are existing around the bottom cell (test cavity MHI#0).

Labo-EP of samples at Nomura Labo-EP (20 um) with EP acid ([Nb] = 4.4 ~ 4.8 g/L) at Nomura 8 Sept Exposing the samples to the air for 30 min. w/o Pure-Water (P.W.) rinse. No stain appeared. Light P.W. rinse for a few 10’s seconds. No stains appeared after exposing the samples to the air. 10

Exposing samples to the air after P.W. rinse No stain appeared after exposing the samples to the air. ( EP acid of [Nb] = 4.8 g/L at the end) No stains P.W. remaining 11

Summary of sample tests [Nb] of EP acid (at the end of EP) Duration of exposure to the air. Stains? Duration of light P.W. rinse Duration of exposure to the air. Stains? 0.4 g/L 70 min. No stainA few 10’s sec. Stains appeared within a min. 4.8 g/L 30 min. No stainA few 10’s sec. 6 min. No stains 8.6 g/L 30 min. No stainA few 10’s sec. 4 min. No stains 12 KEK EP-facility has a big EP-tank of 1000L. When we replace the EP acid with new one, we will keep using new EP acid with some 9-cell cavities for a while. Should we change the amount of EP-acid in the tank? Or should we develop a new U.P.W. rinse method, like introducing N2 during first U.P.W. rinse duration? Considerations

Comparison of EP process among laboratories DESY: The final EP is done with the EP acid of [Nb] ~ 10g/L. JLab: New EP acid is used for the final (20 um) EP 2 times, bulk (>100um) EP, and then dumped. So new EP acid is used for the final EP is similar to KEK. But the rinse process is different from KEK. DI water from bottom BP Overflow Dump water Repeat this sequence a few times DESY and JLab have no stain problem.

Summary After we replaced the EP acid tank with new one, we encountered stain problem with MHI#6, #7, and #8. Sample scraped from test cavity was analyzed with XPS. Only Nb and O components were found. Stains were created only on the sample labo-EP’ed with new EP acid, and just after being rinsed and exposed to the air. Rinse sequence was modified at STF/KEK and Eacc of MHI#9 reached 27 MV/m. But still some stains were found in the test cavity around the bottom cell. Rinse sequence need more modification. DESY uses aged EP acid for final EP. JLab uses new EP acid for final EP but different rinse sequence. Both laboratories have no stain problem.