Vibration Stability Studies of a Superconducting XFEL/ILC Accelerating Module at Room Temperature and at 4.5K R. Amirikas, A. Bertolini, W. Bialowons.

Slides:



Advertisements
Similar presentations
Takanori Sekiguchi Italy-Japan Workshop (19 April, 2013) Inverted Pendulum Control for KAGRA Seismic Attenuation System 1 D2, Institute for Cosmic Ray.
Advertisements

April 27th, 2006 Paola Puppo – INFN Roma ILIAS Cryogenic payloads and cooling systems (towards a third generation interferometer) part II: the Vibration.
ILC Tech Meeting, March 29 th 2007 Cold quadrupole vibration measurements on Module 6 during the 10 th /11th thermal cycles at CMTB Ramila Amirikas, Alessandro.
Multipole Girders - Alignment & Stability (Multipole Girder Alignment technology & R&D) S. Sharma ASD: J. Skaritka, D. Hseuh, V. Ravindranath, G. Miglionico,
Experience Report with the Alignment Diagnostic System Georg Gassner September 17 th 2010.
Laser to RF synchronisation A.Winter, Aachen University and DESY Miniworkshop on XFEL Short Bunch Measurement and Timing.
Stability of Mechanical Systems S. Sharma and V. Ravindranath.
RF Unit Test Facility at NML & CM1 Test Plan Bob Kephart Fermilab IWLC-10 October 20, 2010.
Luminosity Stability and Stabilisation Hardware D. Schulte for the CLIC team Special thanks to J. Pfingstner and J. Snuverink 1CLIC-ACE, February 2nd,
CERN VIBRATION SENSOR PROPOSAL The research leading to these results has received funding from the European Commission under the FP7 Research Infrastructures.
Question 27: Outline the key steps for industrialization of machine components and the likely remaining vulnerabilities in achieving them. Achieving industrialization.
Effects of the cryogenics operational conditions on the mechanical stability of the FLASH linac modules Ramila Amirikas, Alessandro Bertolini, Jürgen Eschke,
1 LAViSta Laboratories in Annecy working on Vibration and Stabilisation Catherine ADLOFF Andrea JEREMIE Jacques LOTTIN Benoît BOLZON Yannis KARYOTAKIS.
1 ATF2 project: Investigation on the honeycomb table vibrations Benoit BOLZON 33rd ATF2 meeting, 24th January 2007 Laboratories in Annecy working on Vibration.
ATF2 week meeting: Impact of cooling water on the final doublets vibrations Benoît BOLZON Laboratories in Annecy working on Vibration Stabilization 15/10/08.
Vibration measurements on the final doublets and the Shintake Monitor Benoît BOLZON7th ATF2 project meeting, 16/12/08.
Burst noise investigation for cryogenic GW detector Hiroshima U. NAOJ Daisuke TATSUMI 3rd Symposium ‐ New Development in Astrophysics through.
Marco Anghileri Dipartimento di Ingegneria Aerospaziale Politecnico di Milano Italy Robust: “Road Upgrade of Standards” GRD Second year meeting.
Techniques to approach the requirements of CLIC stability K. Artoos, O. Capatina (speaker), M. Guinchard, C. Hauviller, F. Lackner, H. Schmickler, D. Schulte.
Global Design Effort - CFS for Asian Single Tunnel Configuration Design Progress Masanobu Miyahara KEK.
Review of Ground Motion Measurement Program of DESY in Various Sites R. Amirikas, A. Bertolini, W. Bialowons LHC tunnel, CERN HERA tunnel, DESY Ground.
Quad-to-quad correlated motion in FLASH Ramila Amirikas, Alessandro Bertolini DESY Hamburg XFEL beam dynamics meeting, February 25 st 2008.
Gek 16/6/041 ITRP Comments on Question 19 GEK 9/06/04 19) For the X-band (warm) technology, detail the status of the tests of the full rf delivery system.
Accelerators for ADS March 2014 CERN Approach for a reliable cryogenic system T. Junquera (ACS) *Work supported by the EU, FP7 MAX contract number.
Recent BTH West Vibration Study for LCLS-II James L. Turner and Alev Ibrahimov February 07, 2012.
Present status of TTF-cryomodules short overview Bernd Petersen DESY MKS March, 7, 2005 Main design features of TESLA-cryomodules Design changes for XFEL-cryomodule.
An Approach to Stabilizing Large Telescopes for Stellar Interferometry It shakes like a…. [G. Vasisht, 31 March 2006] N. Di Lieto J. Sahlmann, G. Vasisht,
Vibration Measurement on the Shintake Monitor and Final Doublet Takashi Yamanaka (Univ. of Tokyo) Benoît Bolzon (LAPP) ATF2 weekly meeting 26 November,
Lutz Lilje DESY -MPY- Module Issues XFEL Linac Review R. Lange/L. Lilje Ongoing Tests Module Designs Future tests.
July 5, 2007 C. HAUVILLER CLIC stabilization Beam line and final focus.
Marc Ross Nick Walker Akira Yamamoto ‘Overhead and Margin’ – an attempt to set standard terminology 10 Sept 2010 Overhead and Margin 1.
Update of a ground motion generator to study the stabilisation usefulness of ATF2 final focus quadrupoles 1 Benoît BOLZON B. Bolzon, A. Jeremie (LAPP)
Beijing ILC Workshop Global Design Effort 1 High-Gradient Module Test Lutz Lilje.
CARE / ELAN / EUROTeV Feedback Loop on a large scale quadrupole prototype Laurent Brunetti* Jacques Lottin**
Oct 17 Fall Report 1 Ground Motion and Vibration for LET Simulation, “Point of Contact” Paul Lebrun CD/FNAL And…
B. Caron, G. Balik, L. Brunetti LAViSta Team LAPP-IN2P3-CNRS, Université de Savoie, Annecy, France & SYMME-POLYTECH Annecy-Chambéry, Université de Savoie,
Type IV Cryomodule (T4CM) Vibration Analysis Update January 23, 2007 Mike McGee 3 rd T4CM Meeting at INFN-Milan.
The control of the Virgo Superattenuator: present and future Giovanni Losurdo - INFN Firenze/Urbino on behalf of the Virgo Collaboration.
1 ATF2 Project Meeting December 2006 Ground Stabilisation with the CERN STACIS 2000 Stable Active Control Isolation System LAViSta Laboratories in.
Main beam Quad Stabilisation: Status of the stabilisation test program at CERN CLIC-stabilization day S. Janssens Contribution to slides by:
Ground Motion spectra status A.Jeremie on behalf of the DESY EUROTeV group which ceased to exist mid-2008 : R.Amirikas, A.Bertolini and W.Bialowons (et.
CLIC Stabilisation Day’08 18 th March 2008 Thomas Zickler AT/MCS/MNC/tz 1 CLIC Quadrupoles Th. Zickler CERN.
Superconducting final doublet Support A.Jeremie. SC magnet steps Motivation: have an active stabilisation as planned in ILC and CLIC => need to evaluate.
Vibrations studies for the nominal optics and the ultra-low beta optics Benoît BOLZON 1 B. Bolzon, A. Jeremie (LAPP) P. Bambade, Y. Renier (LAL) A. Seryi.
Ground motion studies at ATF2 June 11, 2014 Orbit jitter source identification via ground motion studies at ATF2 (Results of the June run) Marcin Patecki,
CERN, 27-Mar EuCARD NCLinac Task /3/2009.
Detail plan of S1-Global H. Hayano (KEK),
FP7: EuCARD after a year of preparation… A.Jeremie.
QD0 stabilisation in CLIC CDR A.Jeremie with LAViSta team.
Vibration measurements with and without Monalisa 15/07/09 Benoît BOLZON (LAPP) David Urner (Oxford) Paul Coe (Oxford) 1 Benoît BOLZON.
CERN –GSI/CEA MM preparation meeting, Magnetic Measurements WP.
Accuracy of the orbit measurement by KEKB BPM system for the study of ILC damping ring H. Fukuma (KEK) Requirement for the accuracy of BPM data.
Summary of Presentation 1. Tolerances i. Vertical tolerances on BPMs (rf-BPM: ± 0.2μm, user BPMs: ±0.1μm, and X-BPMs: ± 0.1μm) ii. Tolerances on magnets’
ILC : Type IV Cryomodule Design Meeting Main cryogenic issues, L. Tavian, AT-ACR C ryostat issues, V.Parma, AT-CRI CERN, January 2006.
EuroTeV WP7 activities at DESY Group Members: R. Amirikas, A. Bertolini, W. Bialowons, H. Ehrlichmann Total Man Power: 1.5 reaching 2 (maximum)
Experiments on thermal cycling
H. Hayano(KEK), B. Petersen(DESY), T. Peterson(FNAL),
Vibration measurements at KAGRA site
BNL-SLAC-Annecy TeleConference
WP5 Elliptical cavities
Alignment methods developed for the validation of the thermal and mechanical behavior of the Two Beam Test Modules for the CLIC project Hélène MAINAUD.
Bellows Vibrations in the 3.9 GHz Cryomodule
EuroTeV WP7 activities in DESY
Topics on Vibration Issues
Laboratories in Annecy working on Vibration Stabilization
Status of Vibration Measurement Work at BNL
Dead zone analysis of ECAL barrel modules under static and dynamic loads for ILD Thomas PIERRE-EMILE, Marc ANDUZE– LLR.
Vibration measurements at KAGRA site
Status of the TESLA Magnet Package and Vibrations at TTF
Microphonics and Energy Jitter
Presentation transcript:

Vibration Stability Studies of a Superconducting XFEL/ILC Accelerating Module at Room Temperature and at 4.5K R. Amirikas, A. Bertolini, W. Bialowons

Methodology Systematic approach: from room temperature to 2K measurements in order to facilitate comparison between ´warm´ vs. ´cold´ on the same cryomodule. Repeated measurements on more than one cryomodule (eg. Superstruktur, Module 6 etc.) to gain a better understanding of a cryomodule stability as a whole. Repeated measurements on each cryomodule and in more than one site (eg. Hall III, #70, FLASH) to check for reproducibility of data. Study the influence of the cryomodule support (tunnel ceiling or floor). Study the behavior of a string of cryomodules in FLASH.

Room Temperature Measurements, Module 6 in Hall III (2006) Vessel Top He GRP Quadrupole Girder Vessel Top vs. He GRP He GRP vs. Quadrupole Vessel Top vs. Quadrupole Reference measurement on the girder/floor Floor Sensor positions (in vertical + Horizontal transverse directions): Z

Room Temperature Measurements, Module 6 in #70 (2007) Typical DESY site spectrum at low frequencies. Technical noise f > 20 Hz; strongest peak from the insulation vacuum pump at 48 Hz. Module vertical resonance at 26 Hz; quad vs. top transfer function almost flat below 40 Hz. Displacement PSDs, vertical, vessel top & ground on 5 March 2007, and their corresponding transfer function. Displacement PSDs, vertical, vessel top & quadrupole on 5 March 2007, and their corresponding transfer function.

Room Temperature Measurements, Module 6 in #70 (2007) Displacement rms 1 Hz: Ground: 76 nm Vessel Top: 90 nm Quadrupole: 103 nm Displacement PSDs, left (vertical, quad & ground) and the corresponding integrated rms, at f > 1 Hz, on 5 March 2007 (shown together with the vessel top, right).

Room Temperature Measurements, Module 6 in #70 (2007) Displacement rms 1 Hz: Ground: 104 nm Vessel top: 370 nm Quadrupole: 448 nm Displacement PSD (horizontal transverse) and the integrated rms at f > 1 Hz of vessel top vs. quadrupole on 12 February 2007.

In the low frequency band, the quadrupole motion tracks the ground vibration level. Slight amplitude differences are related mainly to the mechanical transfer function of the module on its support system. Room Temperature Measurements, Module 6 in #70 (2007) rms analysis of quad and vessel top vibrations vs. time, 5 March 2007 (morning).

Throughout our measurement program, stability within the module (quad vs. He GRP, quad vs. vessel top) is consistently observed within a 20% window, maximum. The support system used for a machine such as XFEL/ILC may play a crucial role in the stability and hence, the quality of its beam/s. A careful design of such girders/support systems should be implemented such that the overall system does not contain resonances below 10 Hz, at least. Our measurements within a cryomodule (quad vs. He GRP and quad vs. vessel top) are reproducible at room temperature conditions. We aim to produce a database of cryomodule vibration measurements and to make it available via our homepage. Our results at room temperature are being used for mechanical design of the ILC cryomodule type IV at Fermilab. A EuroTeV report and a subsequent PAC’07 paper are being prepared (R. Amirikas). Summary

Quadrupole Vibration Measurements at 4.5K Test geophone behavior at 4K inside a fully operating cryomodule. On-board seismic sensor with adequate noise level down to below 1 Hz. Behavior unknown, never been tested by the manufacturer in these extreme conditions; the company recommends use of the device down to -40°C; only one cryogenic application cited in the literature. The very robust and mature (~30 years) design was encouraging and the test has been successful. Chance to give a first quantitative (from 1 Hz) evaluation of the impact of cryogenic plant and high gradient RF on the quadrupole vibration level, not possible so far because of the lack of sensitivity of piezo accelerometers below ~10 Hz.

Quadrupole Vibration Measurements at 4.5K Cold/warm Geophone 20 m cable preamp Inverse filter Test amplifier 24 bit Güralp digitizer 200 S/s Inverse filtering provides equalization of the geophone response down to 0.35 Hz Laptop for Data logging, Spectral analysis (FFT, PSD, Coherence, RMS,Transfer function,etc.) Two new seismic sensors (geophones) were installed aboard the Module 6 quadrupole for the 10/11 th thermal cycles, from February 21 st to March the 8 th. In-situ calibration of the geophones during cool- down was tested.

Quadrupole Vibration Measurements at 4.5K, Cold Steady State-No RF Peak frequency ~ 32Hz in this case. The integrated Hz values are 78 nm (ground), 206 nm (vessel top), 260 nm (quad). This peak is also visible in the ground spectrum and is believed to be originating from the cryogenic operation conditions (preliminary conclusion).

Quadrupole Vibration Measurements at 4.5K, High Power RF Operation Large vibrations due to the build up of a strong peak ~30Hz. The frequency of the peak changes from 30.1Hz up to 32Hz. The amplitude can vary from 200 nm up to > 1 µm. Not a mechanical resonance of the cryomodule; not visible at all in the quad vs. top transfer function. The large step at ~30 Hz, is most probably due to the cryogenic operation conditions in #70 (preliminary conclusion) and needs further investigation.

Preliminary Conclusions & Future Plans A classic 4.5 Hz industrial geophone can operate at 4K without any loss of sensitivity. In-situ high accuracy calibration procedure has been demonstrated. Geophones are a new tool for low frequency vibration investigations at cryogenic temperatures. Low frequency (1-100 Hz) quadrupole vertical stability is not affected by high gradient RF operation (preliminary conclusion). Quadrupole vertical stability is not affected by the refrigeration system at frequencies up to 30 Hz (preliminary conclusion). Results are not conclusive at higher frequencies at this stage. Comparison with operation in the FLASH linac may be insightful. 2K vs. 4.5K? A EuroTeV report and a subsequent PAC’07 paper are currently under preparation (A. Bertolini)

Special Thanks to: The MKS crew Kubczigk (ZBAU) M. Kubczigk (ZBAU) Financial support from EuroTeV: Work supported by the Commission of the European Communities under the 6th Framework Program ‘Structuring the European Research Area’, contract number RIDS