SF6 Gas Density Monitoring

Slides:



Advertisements
Similar presentations
Seminar on Circuit Breaker
Advertisements

MDT JOB PLANNING AND INTERPRETATION
Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.
ENT 164/4 SENSORS & MEASUREMENT
1 Class I Leak Detection Systems - Highest level of monitoring and prevention of double walled tanks and pipes, according EU Standard EN Class.
1 Expansion Tanks. 2 3 Expansion Tanks WHY USE THEM TYPES LOCATION SIZING.
according EU Standard EN
Control and regulation of boiler operation Heat Engines & Boilers.
WHAT IS A CIRCUIT BREAKER
Detect and identify Radiometric Level Measurement in Coke Chambers.
Selection of measuring instruments
Scenario for the gas system 1.High cost gas (5 €/l of Xe) 2.High hydrostatic pressure over 7 m height 3.Light and large detectors, no big under- or.
ACADs (08-006) Covered Keywords Calibrate, direct, inferred, transmitter calibration, gravity correction, density correction, hydrostatic head detector,
Miniature Circuit Breakers (MCB) Multi 9
Temperature Controls Andrew Blackwell For a copy of this presentation please me at This presentation mainly.
SPD Cooling workshop: PLC item details. ups upgrade: 10-12' after trigger 24V - what to do in 10 minutes Present situation: In case of “normal power”
ISAT 303-Lab3-1  Measurement of Condition: Lab #3 (2005):  List of parameters of condition: –Linear distance, angular displacement, vibration, displacement,
Some results of vacuum stand investigation.. 1. Restoration of turbopump inlet valve V1 tightness The inlet turbopump valve of the first pump station.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 8 System Tests.
Nanotechnology Metal Oxide Semiconductor (NTMOS) H2S Gas Sensor
Vadodara institute of engineering,kotambi NAME:NAFISKHANPATHAN(13ELEE181) BARIYA VIPUL(13ELEE182) PATEL AMIT(13ELEE180) BRANCH:EE-2 PPT OF EEE.
Circuit breakers The main purpose of a circuit breaker is to: Switch load currents Make onto a fault Break normal and fault currents Carry fault current.
Transformer Taking the ratio of the two equations
Critical Care Ventilation Technology Perspective Fran Hegarty.
Chemical Engineering 3P04 Process Control Tutorial # 6 Learning goals 1.Learn basic principles of equipment in a control loop 2.Build understanding of.
Hydrodynamic Lubrication Analysis of a Foil Journal Bearing: Pressure and Lift Build-up Jun Shi UTRC.
Final Presentation By Matthew Lewis 17 th March 2006 “To Determine the Accuracy that GOES True Numbers can Reproduce the Full X-ray Spectrum of the Sun”
1 HVACR317 – Core for Refrigeration Operating Controls 1 Thermostats Operating Controls 1 Thermostats.
CENTRIFUGAL PUMP Module 3.2 Vertical Pump Construction
Some notes about liquid Hydrogen target 1.How it operates 2.Modification Target length, empty mode 4.Status.
Welcome to Electric Dept. Rajkot Division. How MCB works.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Graphing Gas Behavior.
Experimental and numerical studies on the bonfire test of high- pressure hydrogen storage vessels Prof. Jinyang Zheng Institute of Process Equipment, Zhejiang.
Claudio Bortolin 03/09/2012. SPD (RP analyses required) 1) Pump 17b replacement and leak test 2)Pressure test on the old inlet lines (technicians coming.
Precipitation Type: __________________ Amount: ________________ Name_________________ Date__________ Temperature High: __________________ Low: ________________.
Rich Dewar Product Line Manager Itron. 2 THE DATTUS III METER / ’s1950’s1930’s1900’s DATTUS III.
Ideal Gases Physics – Molecular Kinetic Theory , &
BA6 Cooling Towers Test Day Process Control Functionality and Performance Tests TCR – PCR Monitoring.
Sensors for Clear Object Detection
Leak tests G. Apeldoorn, P. Vankov , NIKHEF.
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
Johan Bremer, 22th-26th September 2008 Cryogenics Operations 2008, CERN, Geneva, Switzerland 1 CRYOGENICS OPERATIONS 2008 Organized by CERN Safety aspects.
The Measurement of Temperature
Ionization sensors (detectors) In an ionization sensor, the radiation passing through a medium (gas or solid) creates electron-proton pairs Their density.
MICROCONTROLLER DETECTION SYSTEM Joshua Bosiljevac EKU.
Lab Activities: Chamber Baking & Mixing Station Flushing Claudio Curtis Dan PPS meeting 22 June, 2011.
13.1 A Model to Explain Gas Behavior
GASES. Gases  The physical state of gases is defined by several physical properties  Volume  Temperature  Amount (commonly expressed as number of.
HIGH VOLTAGE UNION Vacuum Circuit Breaker 110 kV VRS-110 Series ВЫСОКОВОЛЬТНЫЙ СОЮЗ
VACUUM CIRCUIT BREAKER. WHAT IS A CIRCUIT BREAKER A circuit breaker is an equipment that breaks a circuit either manually or automatically under all conditions.
Section 4: Behavior of Gases. Properties of Gases Gases expands to fill their containers They spread out easily and mix with one another They have low.
Parameter's Approach to Relative Humidity Control August 25, 2011 by Clay Hile.
Tutorial 1 Description of a Weather Station using SensorML Alexandre Robin
Problem Research Hypothesis (proposed solution) Design Experiment Variable and control Record Observations Analyze data Conclusion.
A WEIGHT EXCHANGE SYSTEM FOR AN ABSOLUTE PRESSURE BALANCE Authors: H. Kajastie, J. Manninen, M. Rantanen, K. Riski and S. Semenoja, Centre for Metrology.
Purgers and Non-condensables “What are they and why should I care?” Refrigerating Specialties Division Parker Hannifin Corporation July 2004.
Fermilab’s TRAC Summer Experience Joshua Louis Naperville District 203.
Metal Nanoparticle Hydrogen Sensor
Thin Film Technology - Student Talk Sophie Chauvin 02/02/16 Leak Detection method for Vacuum Systems 1.
Development of The SF6 Circuit Breakers
Sensors and Detectors - 1
Anesthesia Equipment Session 3
GOVERNMENT ENGINEERING COLLEGE, BHARUCH.
ELECTRICAL POWER-II Electrical engineering sixth semester
Prepared by Dr. Mohamed Ahmed Awad
November technical stop activities:
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Presentation transcript:

SF6 Gas Density Monitoring Very low temperature and liquefaction situation with Trafag 87X6 SF6 gas density monitor 05.02.07/ nip

The Reference Gas Principle (Theory) SF6 filled switchgear SF6 filled reference chamber separating membrane DM The temperatures of the gas in the switchgear and the gas in the reference chamber of 87x6 density monitor are „the same“ (depends on the mounting situation) Conclusion: „fully temperature compensation over the whole temperature range“ 05.02.07/ nip

The Density Monitor with Reference Chamber (Picture shows the “older” 87x0 density monitor generation) Tappet moves when SF6 leaks from tank and triggers alarm switch ...inside the monitor Reference chamber filled with gas SF6 gas inlet (connection to tank) 05.02.07/ nip

Behavior of bimetalic-compensated Systems Contact 1, falling (bimetal comp, non-Trafag) True isochor Tolerance band of Trafag DM for calibration Contact 2, falling (bimetal comp, non-Trafag) True isochor Tolerance band of Trafag DM for calibration The accuracy of the alarm levels 05.02.07/ nip

Density Monitor at temperature below -55C Due to the mechanical system the density monitor will still operate below -55°C May be the specifications like accuracy and so on are out of the from Trafag specified values on the datasheets The tolerances of the mechanical system may be are to high for a proper function 05.02.07/ nip

Liquefaction? The reference chamber of 87x6 density monitor is filled at previous alarm density level (1. stage) In regular operation the density at switch breaker is higher (somewhere between filling pressure and previous alarm level) as previous alarm level in reference chamber of 87x6 density monitor Therefore, the liquefaction in switch breaker starts at higher temperature (that means earlier) as in the reference chamber of 87x6 gas density monitor Benefits: Small local liquefaction in the switch breaker will not be detected by the 87x6 density monitor Serious liquefaction which can create a critical situation for the switch breaker get detected by the 87x6 density monitor 05.02.07/ nip