Review of Series Compensation

Slides:



Advertisements
Similar presentations
Introductory Circuit Analysis Robert L. Boylestad
Advertisements

Modeling Electrical Systems With EMTP-RV
New Energy Horizons Opportunities and Challenges Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25,
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
Transmission Operator Protection System Misoperations 2014 ERCOT Transmission Protections System Misoperations Data – 138kV and 345kV Combined (Not including.
Mihai Albulet 윤석현. A class D amplifier is a switching-mode amplifier that uses two active device driven in a way that they are alternately switched ON.
Modeling of Reconnection of Decentralized Power Energy Sources Using EMTP ATP Ing. Dušan MEDVEĎ, PhD. Železná Ruda-Špičák, 25. May 2010 TECHNICAL UNIVERSITY.
Wind Turbine Session 4.
© ERLPhase Power Technologies Ltd. All Rights Reserved. Sub harmonic protection relay S-PRO Krish Narendra, P.hD. CTO ERL – Protection, Automation, Control.
GENERATOR PROTECTION.
Contingency Ranking by Time Domain Simulations ECE 422/522 Russell Patterson Micah Till Terry Jones.
Chapter 4 Synchronous Generators
Sub-Synchronous Interactions with Wind Turbines
Sub-Synchronous Problems and Prevention in ERCOT
Simulation and Analysis Methods for SSR/SSTI/SSCI
Technical Advisory Committee December 6, 2010 Summary of the CREZ Reactive Study Warren Lasher Manager, Long-Term Planning and Policy.
Presented by: Bikram Choudhury Regd. No. : Department of Electrical And Electronics Engineering FACTS Devices For Smart Grid 2 July 2015.
EE 369 POWER SYSTEM ANALYSIS
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
Problem Solving Part 2 Resonance.
High Voltage Power Electronics Technologies for Integrating Renewable Resources into the Grid RenewElec Workshop Carnegie Mellon University October 22,
Importance of advanced simulations of electrical system in wind turbines April 2010.
Fundamentals of Electric Circuits Chapter 11
Flexible AC Transmission Systems: Placement, Control, and Interaction
Series Compensation and SSR - Concepts
ERCOT John Adams September 14, 2012 Planning Guide concepts for dealing with Sub Synchronous Resonance in ERCOT & other issues.
Fundamentals of Electric Circuits Chapter 11
SSR Control of Power Systems
PQSynergy TM 2011 Harmonic Assessment of PEA North1, Chiangmai’s Customers in North Industrial Estate Chotepong Pongsriwat. M.Eng(EE) Chief of Power.
Houston Area Dynamic Reactive Project March 11,
Voltage Collapse M. H. Sadeghi Winter 2007 KNTU. Power System Stability IEEE: Power system stability is defined as the capability of a system to maintain.
PROJECT NO PUCT STAFF WORKSHOP 11/19/14 Julia Harvey Kristi Denney Kevin Mathis Jasmin Thevaril.
Conclusions Innovative application of induction and synchronous generators in autonomous small hydropower plant Prof. M.T.E. Kahn NeuroMorphoGenics/NMG.
Voltage grid support of DFIG wind turbines during grid faults
1 TRANSMISSION SYSTEM OVERVIEW NETWORK OPERATING COMMITTEE April 17, 2007 New Mexico Transmission System Overview.
September 25, 2012 Planning Working Group - PLWG Sub-Synchronous Resonance Protection & Mitigation John Adams Principal Engineer.
Copyright © SEL 2012 A Comparison of Different Signal Selection Options and Signal Processing Techniques for Subsynchronous Resonance Detection Yu Xia,
Synchronous Voltage Reversal control of TCSC – impact on SSR conditions Hailian Xie Lennart Ängquist EME/ETS, Royal Institute of Technology, Stockholm.
SSR Monitoring in EMS Bill Blevins Manager, Operations Planning.
Protection & Switchgear
Lecture 22 Unbalanced Faults and Power System Protection Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Announcements Read Chapters 10 and 11
UNIT-VII Static Series Compensators
Power Quality By Using FACTS. CONTENTS INTRODUCTION WHAT IS FACTS? FOR WHAT PURPOSE FACTS ARE USED? BASIC TYPES OF FACTS CONTROLLERS BENEFITS OF UTILISING.
Chapter 9 CAPACITOR.
Application of Torsional Stress Relays
Lone Star Transmission Presentation on SSR Blair Giffin Operations Engineer September 9, 2013.
 The common type of wind power generators are squirrel cage induction generator (SCIG),doubly fed induction generator (DFIG)  For more secure and.
CASE : ENHANCE INTER-REGION POWER TRANSFER IN EXTRA HIGH VOLTAGE
Announcements Design Project has firm due date of Dec 4
Effects of GIC Neutral Blocking Devices (NBDs) on Transmission Lines Protection Performance and Potential for Resonance.
A Project Review On POWER QUALITY IMPROVEMENT IN GRID USING STATECOM
FACTS BY SVC, FLEXIBLE AC TRANSMISSION
Overview of Flexible AC Transmission Systems
IG BASED WINDFARMS USING STATCOM
PSCAD models.
Analysis of the Amplitude and Frequencies of the Voltage Magnification Transients in Distribution Networks due to Capacitor Switching Mohamed Saied Electrical.
WELCOME TO ALL.
Wind turbine technology
Transmission Solutions
Transient Analysis of Shunt Reactor Switching on 500kV System
Passive Shunt Compensation
Series Capacitor Compensation
POWER SYSTEM ANALYSIS INTRODUCTION.
Electric braking Powerpoint presentation by:- Poonam sharma
Protective Relaying Conference
Considerations and Benefits of Using Five Zones for Distance Protection Ricardo Abboud, Jordan Bell, and Brian Smyth Schweitzer Engineering Laboratories,
Unit III OPERATION OF TCSC.
FACTS BY SVC, FLEXIBLE AC TRANSMISSION
Presentation transcript:

Review of Series Compensation Douglas Bowman, P.E. Research, Development, and Special Studies Date: May 20-21, 2014

Contents Series Compensation Series Compensation Types Subsynchronous Interactions (SSI) - Terms Fundamentals of SSI and Series Compensation Forms of SSI SSI and Series Compensation Tools for Assessment of SSI in Series Compensated Networks SSI Mitigation Measures SSI Protection Measures Protective Relay Considerations for Series Compensated Networks Protective Relay Solutions for Series Compensated Networks Project Planning for Implementation Design Studies Concluding Remarks

Benefits of Series Compensation Increases power transfer capability Improves transient performance Improves reactive power balance Improves Voltage Stability Improves power flow balance on adjacent lines Deferral of major transmission investments Preservation of existing rights of way Benefits of Series Compensation

Increases Power Transfer Capability Series Compensation Since transmission lines are mostly inductive, adding series capacitance decreases its total reactance Reducing XL increases PR Compensation Level K is defined as the percent of XLoffset by the series capacitor Example: For XL = 1 ohm, 30% compensation produces XL - XC = .7 ohm Increases Power Transfer Capability

Improves Transient Performance Following Disturbances Series Compensation If A1 > A2, the generator will return to stability Series compensation increases the system stability limits by reducing the system reactance between machines as this directly increases the synchronizing torque that can be interchanged between them Improves Transient Performance Following Disturbances

Series Compensation Reactive Power Balance For A 300 Mile 500kV Line Transmission Line Reactive Power Losses : Qlosses=I2Xline Series Capacitor Reactive Power Output: Qoutput=I2Xcapacitor As a transfer across the line increases, Qoutput partially offset Qlosses Improves Reactive Power Balance and Self-Regulation

Effect of Increasing Compensation Levels Improves Voltage Stability Series Compensation Increasing compensation levels K provides greater Qoutput capability Maximum power transfer capability of the line is increased Generator reactive power is made available for voltage control Effect of Increasing Compensation Levels Improves Voltage Stability

Series Compensation Types Continuous current rating according to the line Overvoltage protection Zinc Oxide Varistor (MOV) Conducts when voltage level across capacitor reaches protection level Fast Protective Device (FPD) For example, an air gap conducts when energy absorbed by MOV exceeds rated values. Bypass Breaker Damping Reactor Fixed Series Compensation (FSC)

Series Compensation Types Two Modules FSC as previously described Capacitor with thyristor controlled, air cooled reactor to modulate line impedance FACTS Device Offers Dynamic Power Flow Control Reactance can be modulated to effectively mitigate SSI Blocked Mode removes reactor from circuit By-Passed Mode removes capacitor from circuit Controlled Mode varies total reactance Thyristor Controlled Series Compensation(TCSC)

Subsynchronous Interactions (SSI) - Terms Subsynchronous Interaction – A general term describing the condition where two or more parts of the power system exchange energy at one or more frequencies below the fundamental frequency (60 hz). Subsynchronous Oscillation - An SSO is a condition where the electric network exchanges significant energy with a turbine generator at one or more of the natural frequencies of the combined system below the synchronous frequency of the system following a disturbance from equilibrium. SSI can lead to SSOs that must be damped before outage or damage to network equipment occurs Subsynchronous Resonance (SSR) – A type of SSI where the electric power system, most often a series compensated transmission line, exchanges energy with a turbogenerator at one or more natural frequencies below the fundamental 60hz frequency (three types of SSR)

Fundamentals of SSI and Series Compensation A power system’s natural electrical frequencies are a function of its inductance and capacitance. When new capacitance is added, new natural electrical frequencies result and the system natural frequency approaches the fundamental frequency fo A generator’s shaft may also have multiple natural frequencies of oscillation Four natural frequencies or torsional modes for the system shown

* Interaction with series compensation does not occur during SSTI Forms of SSI * * Interaction with series compensation does not occur during SSTI Subsynchronous Resonance (SSR) – The electric power system, most often a series compensated transmission line, exchanges energy with a turbogenerator at one or more natural frequencies below the fundamental 60hz frequency. Three types of SSR: Torsional Interaction (SSR-TI) – interaction between the mechanical system (turbogenerator) and a series compensated power system when small disturbances occur. This is the classic SSR condition. Induction Generator Effect (IGE) – This is self-excitation of a series compensated power system. This is independent of the generator shaft torsional modes. Purely electric resonance condition. Torque Amplification (TA) – amplification of turbogenerator shaft system stress by transient torques on generator rotors caused by severe disturbances in a series compensated power system. Subsynchronous Control Interactions (SSCI) – A condition where a power electronic device (HVDC, SVC, STATCOM, Wind turbine control, etc) interacts with the electric power system containing nearby series compensated transmission . Subsynchronous Torsional Interaction (SSTI) – A condition where there is a control interaction between power electronic device and the mechanical mass system of a turbogenerator. Does not interaction with series compensation.

SSI and Series Compensation SSR – TI (Torsional Interaction) When a small disturbance occurs, simultaneous excitation of all natural frequencies (modes) of oscillation occurs in both the electrical system and the generator If the electrical and mechanical natural frequencies are close to one another, sustained or growing rotor oscillations can occur resulting in possible torsional fatigue damage to the turbine generator shaft. This is classic SSR-TI. SSR – TA (Torsional Amplification) When a large disturbance occurs, the subsynchronous transient current frequency may be close to the generator natural torsional frequency Can lead to prolonged generator shaft oscillations with high amplitude causing increased stress and accelerated loss of life.

SSI and Series Compensation IGE (Induction Generator Effect) Purely electrical resonance effect Combined generator and electric power system results in a negative effective rotor resistance at a natural frequency below 60 hz If the negative rotor resistance is greater than the apparent stator plus network resistance, self –excited, subsynchronous current and electromagnetic torque can result SSCI – (Control Interaction) ERCOT 2009 Event Event between wind generators and series compensated transmission line 2 pu overvoltage damaged rotor side protection circuits Wind farm became radially connected through series capacitor 1.5 seconds before capacitor was bypassed Resonance between Capacitor and Wind Turbine Converter/Control Only Type 3 and Type 4 Turbines Can Be Affected See report for ERCOT’s SSI study process for new wind generation

Mohave SSR-TI Incident (1970) Mohave generator: 1,580 MW coal-fired in NV. Gradually growing vibration that eventually fractured a shaft section. First investigations incorrectly determined cause. After 2nd failure in 1971 cause was identified as Subsynchronous Resonance. An electrical resonance at 30.5 Hz excited a mechanical resonance at 30.1 Hz. Problem was solved by reducing compensation and installing a torsional relay. D. Baker, G. Boukarim, “Subsynchronous Resonance Studies and Mitigation Methods for Series Capacitor Applications,” IEEE 2005. D. Walker, D. Hodges, “Results of Subsynchronous Resonance Test At Mohave,” IEEE 1975.

Tools for Assessment of SSI in Series Compensated Networks Frequency Scan Screening Calculates apparent impedance from generator from 0 to 60 hz Can identify potential IGE, SSR-TI, SSR-TA, and SSCI problems Eigenvalue Analysis System model linearized, small pertubations examined Identifies torsional mode damping characteristics Used to study SSR-TI and SSCI problems Damping Torque Analysis EMT type software used for analysis Examines electrical torque response to small change in generator speed to determine damping characteristic Practical for evaluating SSR-TI Time Domain Analysis Most useful in studying SSR-TA problems

SSI Mitigation Measures (SSI Prevention) Network Based Preventative Measures to Reduce a Known Risk of SSI Operational Procedure Alter the network configuration or generation dispatch Bypass the Capacitor or reduce its compensation level Passive Filter Damping for series resonance network condition Shunt or Series Shunt and Series FACTS Active Shunt Filter Damping STATCOM or SVC FACTS Active Series Filter Damping Thyristor Controlled Series Compensation (TCSC) Unified Power Flow Controller (UPFC)

SSI Mitigation Measures (SSI Prevention) Generator Based Preventative Measures to Reduce a Known Risk of SSI Passive Filter Damping Active Filter Damping (FACTS devices such as TCR or STATCOM) Supplemental Excitation Control Damping Wind Turbine Control Damping Type 3 and 4 turbines use VSC as basis for control Newer controls since 2009 mitigate SSI

SSI Protection Measures (SSI Detected) Series Capacitor Bypass Newer relays developed for SSCI since 2009 Generator Relays Relay Signal Input Comments Torsional Motion (Stress) Relay Shaft Speed Developed and applied in the late 1970s. Speed is processed by band-pass filters to calculate conditions at particular sub-synchronous frequencies of interest. Torsional Stress Relays (TSR) have been applied at several generator units and are still available. Newer torsional motion relays are micro-processor based. Appears to be the most widely applied measure to protect genertors from the potential of SSI due to proximity of HVDC or series compensated lines. S. California Edison patent Terminal voltage Micro-processor relay that uses exclusive time domain analysis on wave parameters of successive half cycles. More research is recommended as to the application of this 1986 patent, performance information, and current status. ABB Research Ltd. patent Generator Terminal voltage Micro-processor based relay developed in the 2011 timeframe. ERLPhase Power Technologies Terminal voltage and currents Micro-processor based relay is used to perform frequency spectrum analysis on the inputs to compare sub-synchronous frequency components with fundamental component. Relay Application Innovation Armature current Micro-processor based relay. Developed in late 2009 and applied in 2010 by AEPSC at two locations as backup generator protection. Summary of Generator Based SSI Relays

Protective Relay Considerations for Series Compensated Networks Voltage and current inversion due to nearby fault Measured Impedance of Distance Protection when series compensation switched in and out Subsynchronous Transient Signal Impacts on apparent impedance Adjacent Line Impacts Unbalanced Line and Mutual Impedance Impacts Automatic Reclosing for Series Compensated Transmission Lines Series Capacitor Switching Three Phase Automatic Reclosing Single Phase Automatic Reclosing Spurious Bypass Operation

Protective Relay Solutions for Series Compensated Networks Advanced Relays for Series Compensation Application Memory Polarization Special Series Compensation Logic Sequence Component Impedance for Directional Discrimination Protection Schemes Line Current Differential Protection Directional Comparison Protection Permissive Overreach Scheme Underreaching Direct Trip and Direct Transfer Trip Scheme Protection Design and Performance Verification EMT simulation of various system conditions recommended for the chosen protection scheme See report for various case studies

Project Planning and Implementation Location of Series Compensation – affects effectiveness, voltage profile, protections settings, future configuration, operation and maintenance Mid-Line Installation Line Ends Installation Modularity of Series Compensation for staged development Design for Future Network Modifications Operations and Maintenance Considerations FSC - majority of equipment used is already likely found in the system TCSC – redundant power electronic modules allows replacement of faulty modules Operations and Reliability Remote control functionality

Design Studies Steady State and Short Circuit analysis Transient Stability Analysis Harmonics and Subsynchronous Frequency Scans to identify possible resonance issues Short-Term Transient Voltage and Switching Studies (EMTP type) to determine Maximum energy on varistors Maximum transient voltage and current on capacitors TRV on circuit breakers Required size of MOV and damping circuit components Small Signal Analysis to determine impact of series capacitor on current modes of oscillation

Concluding Remarks Series Compensation used worldwide since 1950s Series Compensation is a tried and true technology that continues to grow in popularity as an effective means of resolving a number of network issues The risk of SSI is relatively low; however, the consequences of an SSI event can be significant. The risk and consequences must factor into series compensation design including controls and protection. The SSI phenomenon is well understood and effective mitigations measures are available Series Compensation should be included in the planners’ toolbox and considered as an available option.