ILC-ECFA Workshop Valencia 06-10 November 2006 Four-fermion processes as a background in the ILC luminosity calorimeter for the FCAL Collaboration I. Božović-Jelisavčić,

Slides:



Advertisements
Similar presentations
Proposal for a new design of LumiCal R. Ingbir, P. Ruzicka, V. Vrba October 07 Malá Skála.
Advertisements

GUINEA-PIG: A tool for beam-beam effect study C. Rimbault, LAL Orsay Daresbury, April 2006.
P hysics background for luminosity calorimeter at ILC I. Božović-Jelisavčić 1, V. Borka 1, W. Lohmann 2, H. Nowak 2 1 INN VINČA, Belgrade 2 DESY, Hamburg.
Pair backgrounds for different crossing angles Machine-Detector Interface at the ILC SLAC 6th January 2005 Karsten Büßer.
1 Hadronic In-Situ Calibration of the ATLAS Detector N. Davidson The University of Melbourne.
I. Božović-Jelisavčić, LCWS10, Beijing, March LUMINOSITY MEASUREMENT AT ILC I. Bozovic-Jelisavcic (on behalf of the FCAL Collaboration)
Single boson production at LEP Guillaume Leibenguth On behalf of the LEP experiments Institut de physique nucléaire Université catholique de Louvain DIS’04,
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
Karsten Büßer Beam Induced Backgrounds at TESLA for Different Mask Geometries with and w/o a 2*10 mrad Crossing Angle HH-Zeuthen-LC-Meeting Zeuthen September.
Effect of the Shape of the Beampipe on the Luminosity Measurement September 2008 Iftach Sadeh Tel Aviv University DESY.
1 LumiCal Optimization and Design Takashi Maruyama SLAC SiD Workshop, Boulder, September 18, 2008.
Crossed Channel Compton Scattering Michael Düren and George Serbanut, II. Phys. Institut, - some remarks on cross sections and background processes  
Ronen Ingbir Collaboration High precision design Tel Aviv University HEP Experimental Group Krakow2006.
Ronen Ingbir Collaboration High precision design Tel Aviv University HEP Experimental Group Cambridge ILC software tools meeting.
Possibility for Double DVCS measurement in Hall A Alexandre Camsonne SBS Meeting June 4 th 2013.
ESFA/DESY LC Workshop 1 Klaus Mönig and Jadranka Sekaric Klaus Mönig and Jadranka Sekaric DESY - Zeuthen MEASUREMENT OF TGC IN e  COLLISIONS AT TESLA.
Precise Measurements of SM Higgs at the ILC Simulation and Analysis V.Saveliev, Obninsk State University, Russia /DESY, Hamburg ECFA Study Workshop, Valencia.
Jan MDI WS SLAC Electron Detection in the Very Forward Region V. Drugakov, W. Lohmann Motivation Talk given by Philip Detection of Electrons and.
Karsten Büßer Beam Induced Backgrounds at TESLA for Different Mask Geometries with and w/o a 2*10 mrad Crossing Angle LCWS 2004 Paris April 19 th 2004.
Analysis of Beamstrahlung Pairs ECFA Workshop Vienna, November 14-17, 2005 Christian Grah.
Instrumentation of the very forward region of the TESLA detector – summary of the Workshop on Forward Calorimetry and Luminosity Measurement, Zeuthen,
HERA-LHC, CERN Oct Preliminary study of Z+b in ATLAS /1 A preliminary study of Z+b production in ATLAS The D0 measurement of  (Z+b)/  (Z+jet)
Simulation of physics background for luminosity calorimeter M.Pandurović I. Božović-Jelisavčić “Vinča“ Institute of Nuclear Sciences, Belgrade, SCG.
2. December 2005Valencia Workshop Very Forward Region Instrumentation Wolfgang Lohmann, DESY Basic functions: - Hermeticity to small polar angles - Fast.
Ivan Smiljanić Vinča Institute of Nuclear Sciences, Belgrade, Serbia Energy resolution and scale requirements for luminosity measurement.
Trilinear Gauge Couplings at TESLA Photon Collider Ivanka Božović - Jelisavčić & Klaus Mönig DESY/Zeuthen.
14-18 November, PrahaECFA/DESY Linear Collider Workshop 1 TRILINEAR GAUGE COUPLINGS AT PHOTON COLLIDER - e  mode DESY - Zeuthen Klaus Mönig and Jadranka.
September, 19 FCAL Worlshop in Tel Aviv W. Lohmann, DESY Physics Requirements Input From Theory Lessons from LEP LumiCal Simulations BeamCal.
1Frank Simon ALCPG11, 20/3/2011 ILD and SiD detectors for 1 TeV ILC some recommendations following experience from the CLIC detector study
Measurement of the branching ratios for Standard Model Higgs decays into muon pairs and into Z boson pairs at 1.4 TeV CLIC Gordana Milutinovic-Dumbelovic,
Karsten Büßer Instrumentation of the Forward Region of the TESLA Detector International Europhysics Conference on High Energy Physics Aachen, July 19th.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
16 June, 2015 В.И. Тельнов 1 Two-photon experiments with detector MD1 at VEPP-4 Valery Telnov Budker INP and Novosibirsk St. Univ. PHOTON 2015, June 16,
Two photon physics with forward detectors Beata Krupa, Leszek Zawiejski Institute of Nuclear Physics Polish Academy of Sciences 22nd FCAL Collaboration.
Beata Krupa Institute of Nuclear Physics Polish Academy of Sciences The study of the photon structure functions at the ILC energy range LCWS –
Optimization of the Design of the Forward Calorimeters ECFA LC Workshop Montpellier, 15 November 2003 *FC Collaboration: Colorado, Cracow, DESY(Zeuthen),
A Luminosity Detector for the Future Linear Collider Ronen Ingbir Prague Workshop HEP Tel Aviv University.
HEP Tel Aviv University LumiCal (pads design) Simulation Ronen Ingbir FCAL Simulation meeting, Zeuthen Tel Aviv University HEP experimental Group Collaboration.
Pad design present understanding Tel Aviv University HEP Experimental Group Ronen Ingbir Collaboration High precision design Tel-Aviv Sep.05 1.
February, INP PAN FCAL Workshop in Cracow W. Lohmann, DESY The BCD (Baseline Configuration Document) The next calendar dates Where we are with FCAL.
2° ILD Workshop Cambridge 11-14/09/08 The sensitivity of the International Linear Collider to the     in the di-muon final state Nicola D’Ascenzo University.
1 Some results from LumiCal Monte Carlo Studies Michał Karbowiak, B. Pawlik, L. Zawiejski Michał Karbowiak (*), B. Pawlik, L. Zawiejski Institute of Nuclear.
1 Calorimeters of the Very Forward Region Iftach Sadeh Tel Aviv University DESY Collaboration High precision design March 5 th 2008.
Measurement of inclusive jet and dijet production in pp collisions at √s = 7 TeV using the ATLAS detector Seminar talk by Eduardo Garcia-Valdecasas Tenreiro.
Gordana Milutinovic-Dumbelovic Vinca Institute of Nuclear Sciences, Belgrade Ivanka Bozovic-Jelisavcic, Strahinja Lukic, Mila Pandurovic Branching ratio.
HEP Tel Aviv UniversityLumical - A Future Linear Collider detector Lumical R&D progress report Ronen Ingbir.
The Luminosity Calorimeter Iftach Sadeh Tel Aviv University Desy ( On behalf of the FCAL collaboration ) June 11 th 2008.
1 LumiCal Optimization Simulations Iftach Sadeh Tel Aviv University Collaboration High precision design May 6 th 2008.
On the possibility of stop mass determination in photon-photon and e + e - collisions at ILC A.Bartl (Univ. of Vienna) W.Majerotto HEPHY (Vienna) K.Moenig.
Beam-Beam interaction SIMulation: GUINEA-PIG C. Rimbault, LAL Orsay CARE 05, Geneva, November 2005.
Systematic limitations to luminosity determination in the LumiCal acceptance from beam-beam effects C. Rimbault, LAL Orsay LCWS06, Bangalore, 9-13 March.
Fast and Precise Luminosity Measurement at the ILC Ch.Grah LCWS 2006 Bangalore.
Correction methods for counting losses induced by the beam-beam effects in luminosity measurement at ILC Ivan Smiljanić, Strahinja Lukić, Ivanka Božović.
1 Jets in PHENIX Jiangyong Jia, Columbia Univerisity How to measure jet properties using two particle correlation method (In PHENIX)? Discuss formula for.
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
1/24 SiD FCAL Takashi Maruyama Tom Markiewicz SLAC TILC’09, Tskuba, Japan, April 2009 Contributors: SLAC M. BreidenbachFNALW. Cooper G. Haller K.
September 2007SLAC IR WS Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY Talks by M. Morse, W. Wierba, myself.
LumiCal background and systematics at CLIC energy I. Smiljanić, Vinča Institute of Nuclear Sciences.
1 LoI FCAL Takashi Maruyama SLAC SiD Workshop, SLAC, March 2-4, 2009 Contributors: SLAC M. BreidenbachFNALW. Cooper G. Haller K. Krempetz T. MarkiewiczBNLW.
HEP Tel Aviv University Lumical R&D progress report Ronen Ingbir ECFA - Durham2004 Lumical - A Future Linear Collider detector.
Octobre 2007LAL Orsay Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY.
FCAL Workshop Munich -17 October 2006FCAL Workshop Munchen -17 October 2006 Four-fermion processes as a background in the luminosity calorimeter M.Pandurović.
FCAL Krakow meeting, 6. May LumiCal concept including the tracker R. Ingbir, P.Růžička, V. Vrba.
Very Forward Instrumentation: BeamCal Ch. Grah FCAL Collaboration ILD Workshop, Zeuthen Tuesday 15/01/2008.
Potential and challenges of the physics measurements with very forward detectors at linear colliders Ivanka Bozovic Jelisavcic [on behalf of the FCAL Collaboration]
Initial proposal for the design of the luminosity calorimeter at a 3TeV CLIC Iftach Sadeh Tel Aviv University March 6th 2009
BDIR/MDI Summary ECFA Final Plenary
Forward Tagger Simulations
Summary of the FCAL Workshop Cracow, February 12-13
BDIR/MDI Summary ECFA Final Plenary
Presentation transcript:

ILC-ECFA Workshop Valencia November 2006 Four-fermion processes as a background in the ILC luminosity calorimeter for the FCAL Collaboration I. Božović-Jelisavčić, M.Pandurović “Vinča“ Institute of Nuclear Sciences, Belgrade, Serbia FCAL

Overview I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November Layout of the forward region as in the LDC has being assumed - To avoid  dependent systematic effects forward calorimeters are centred along the outgoing beam, in a concept of colliding beams with a crossing angle - All of the detectors in the Very Forward Region are to improve the hermeticity and jet energy resolution and they shield the central detectors from backscattered particles - Luminosity calorimeter is being designed for the precise determination of the total luminosity by measuring the number of Bhabha events produced in the detector acceptance region - Precision of order of is required at ILC for the calculation of the cross-sections and precise EW measurements - Four-fermion NC processes are considered to be the main source of physics background for luminosity measurement

Simulation and assumptions I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November 2006 We applied following assumptions on generation and reconstruction: SIGNAL |  |< Signal consists of 10 5 Bhabha events (~22 pb -1 ) generated with BHLUMI generator (integrated in BARBIE) with the cross-section of (4.58±0.02) nb in the angular region (1.43<|  |<5.27)deg. - Both s and t channels are included as well as vacuum polarization option and initial state radiation - This sample corresponds to the rate of 8·10 -3 tracks per BX in the luminosity calorimeter acceptance region - NC four-fermion processes (e + e -  e + e - ff ) are generated with WHIZARD1.40 multiparticle event generator with average rate of 3·10 -3 tracks per BX in the luminosity calorimeter. Fragmentation has been simulated using PYTHIA V Response of luminosity calorimeter is simulated using BARBIE V4.1 detector simulation package - Simulation is done for the calorimeter with inner radius of 8 cm and outer radius of 28 cm, consisting of 30 readout planes, each plane being subdivided into 64 concentric rings or 120 radial strips alternately (so called 'strip design').

I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November 2006 PROPERTIES OF BACKGROUND BACKGROUND - We have generated 10 6 e + e -  e + e - l + l - (l=e,  ) events with the cross-section of (1.54±0.03) nb and 10 5 e + e -  e + e - qq (q=u,d,s,c,b) events with the cross-section of (1.14±0.02) nb - Background processes are simulated at tree level - We assumed that invariant mass of outgoing pairs e + e -, ff is larger than 1GeV/c 2 - Momentum transferred in photon exchange is greater than 1 GeV/c - Simulation is done for head-on collisions at 500 GeV centre-of-mass energy Feymann diagrams contributing to NC four-fermion production, with the dominant multiperipheral processes.

E GeV e mu LUMICAL BEAMCAL E GeV  nb e+e-e+e-l+l-e+e-e+e-l+l- e + e -  e + e - qqbar sqrt(s) GeV - Outgoing e + e - pairs are emitted along the beam pipe carrying the most of energy while l + l - pairs or quark fragmentation products are mostly low energetic and distributed over a wider polar angle range - Due to steep polar angle distribution of produced particles, the most of energy is to be deposited in the beam calorimeter while low-energetic particles are deposited in the luminosity calorimeter -- Total cross-section for both e + e -  e + e - l + l - and -e + e -  e + e - qqbar processes is decreasing with sqrt (s) PROPERTIES OF BACKGROUND I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November 2006

Electrons from Bhabha scattering are: - Collinear (back-to-back) - Coplanar - High-energetic Isolation cuts of signal from background are derived from these properties: - Acollinearity cut |  |< 0.06 deg - Acoplanarity cut |  |< 5 deg - Relative energy cut (E F +E B )/2E beam > Energy balance cut |E F(R) -E B(L)  |<0.1 E min E min =min(E F(R) -E B(L) ) PROPERTIES OF SIGNAL I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November 2006

signal background leptonic bck. hadronic bck. Track rates and occupancy Following track rates have been found in the luminosity calorimeter: - Signal: 8·10 -3 tracks/BX - Leptonic background: 1·10 -3 tracks/BX - Hadronic background: 2·10 -3 tracks/BX what is in agreement with the independent study of two-photon production of electrons using Vermasseren event generator (L.Suszycki, FCAL Workshop, Tel Aviv, September(2005) In terms of occupancy, physics background would contribute to it approximately 10 times less than signal I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November 2006

All isolation cuts are applied assuming ideal reconstruction (no detector resolution effect) and 100% reconstruction efficiency. Previous studies have shown that Bhabha electrons can be detected with almost 100% efficiency even in the regions with high beamstrahlung background leptonic bck. hadronic bck. leptonic bck. hadronic bck.

I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November 2006 leptonic bck. hadronic bck. leptonic bck. hadronic bck.

I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November 2006 Rejection rate Efficiency Efficiency HadronicbacgroundLeptonicbackgroundBhabha % % 80.6 % B/S: 1.3· % % % % E bal <0.1 E min % % % |  | < 5 deg % % % |  |< 0.06 deg CUT If relative energy cut would be applied instead of the energy balance cut, approximately the same efficiency of signal would be maintained with somewhat worse B/S ratio: 2.6·10 -4

Hits in the luminosity calorimeter Projection of hits at the front plane of the luminosity calorimeter is illustrated for events that have at least a pair of tracks at opposite sides of lumical I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November 2006

Resolution requirements from physics background In order to maintain background to signal ratio to the required level of 10 -4, the minimal detector resolution needed in reconstruction of the polar angle  is over 1 mrad, that is very close to   cut-off value we apply as isolation cut. This is far below the detector resolution of order of mrad estimated for both designs from the detector performance study. We can conclude that, with the set of isolation cuts applied, signal to background ratio is practically insensitive to detector resolution effects. B.Pawlik, Krakow  L/L  2  /  min rad. detector resolution acollinearity cut

I. Božović-Jelisavčić I. Božović-Jelisavčić ILC-ECFA Workshop Valencia November 2006 Conclusion - Precision of luminosity determination of order of is required at ILC for the calculation of the cross-sections and precise EW measurements. Four-fermion NC processes are considered to be the main source of physics background for luminosity measurement. - Due to the characteristic topology of Bhabha events, it is possible to keep the background from four-fermion NC processes within the required of background to signal ratio, with the loss of efficiency of approximately 20 %. - This study has been done assuming ideal reconstruction (no detector resolution effect) and 100% reconstruction efficiency. However, it has been shown that detector resolution requirements from physics background are well below the detector resolution estimated from detector performance study. - Detector occupancy from the physics background is expected to be approximately 10 times less than the one from signal.